Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR R61A201307300707Faucet · corrodedDURING HEAVY CHECK, AFT GALLEY WATER FAUCET CORRODED. MX R & R AFT WATER FAUCET IAW CMM 25-34-97.SDR CALA2013073090098Coffeemaker · sparksM71 COFFEEMAKER SPARKING. CAPTAIN HAD CIRCUIT BREAKER PULLED. REPLACED COFFEMAKER.SDR CALA2013073090096Chiller · noisyNOISY CHILLERS IN FWD GALLEY ASSOCIATED WITH ELECTRICAL ODOR. CHILLER CIRCUIT BREAKER HAS BEEN COLLARED 025648. AIR INLET FILTER, OPS CHECKED NORMAL.SDR CA130726003Coffeemaker · odor(CAN) IN CRUISE, F/A NOTICED THE PRESENCE OF AN ELECTRICAL ODOR AND SMOKE ORIGINATING FROM THE LEFT COFFEEMAKER. THE CIRCUIT BREAKER WAS PULLED AND THE ODOR/SMOKE DISSIPATED. UNIT HAS BEEN REMOVED AND WILL BE SUBJECTED TO FURTHER INVESTIGATION.SDR YENA20130722157Coffeemaker · odorCREW REPORTED BURN ODOR IN THE GALLEY. FAULT ISOLATION PERFORMED IAW FIM 21-20-00-810-801-A, PAGE 205, BLOCK 1 AND FIM 25-30-00-810-801-A, FOUND THE FORWARD LT COFFEEMAKER AT FAULT. OPENSDR SWAA2013072218379Coffeemaker · leakingAIR TURNBACK DURING INITIAL CLIMB OUT, ACRID SMELL NOTED IN COCKPIT, FLIGHT ATTENDANT’S REPORTED MILD SMOKE & ELECTRIC ARCING VICINITY OF COFFEE-MAKER CIRCUIT BREAKERS. FOUND NR 2 COFFEE MAKER RACK LEAKING CAUSING WIRING HARNESS BELOW FOR NR 3 COFFEE MAKER TOSDR CALA2013072300510Oven · odorPILOT REPORTED, OVEN 305 ELECTRICAL ODOR AFTER USAGE. INSPECTED OVEN 305 CONNECTOR AND WIRING FOR EVIDENCE OF BURNING. NONE FOUND, IAW AMM 08-51-58-910-801C1. REMOVED OVEN 305 AS A PRECAUTION, OPS CHECKED NORMAL.SDR UALA2013072305167Oven · contaminatedPLASTIC BURNING ODOR. FOUND MELTED PLASTIC FROM A PLASTIC TRAY, REMOVED TRAY AND PLASTIC TRACE.SDR UALA2013071905080Oven · odorAFTER ENGINE SHUTDOWN, F/A`S SMELLED A PLASTIC BURNING ODOR WITH NO SMOKE. CLEANED WARMING OVEN, CHECKED OPERATION. OK, NO ODOR FOUND.SDR DALA13034585531Oven · dirtySMOKING BURNING PLASTIC ODOR. MX INSPECTED CONFIRMED TWO MEAL CARRIER CONTAINERS CONTAINED BURNED PLASTIC RESIDUE-CARRIERS REMOVED FROM ACFT AND RENDERED UNSERVICEABLE. FURTHER INSPECT OF OVENS NOTED NO CONTAMINATION-HEATED OVENS WITH NO DEFECTS.SDR USAA2013070300003Service Cart · faultyEN-ROUTE, THE GALLEY FOOD HEATING UNIT IN THE AFT GALLEY MELTED THE PLASTIC FOOD TRAYS AND EMITTED AN ODOR. THEY WERE NEW FOOD TRAYS. MX EXCHANGED ALL HEATING UNITS AND VISUALLY CHECKED ALL CORDS. NO DAMAGE FOUND.SDR SWAA2013070517950Coffeemaker · faultyAFT COFFEE MAKER TURNED OFF & CIRCUIT BREAKERS PULLED WHEN SMELL OF BURNING RUBBER WAS NOTED. FOUND AFT GALLEY COFFEE MAKER NR 1 TO BE SOURCE OF ELECTRICAL SMELL. COMPLIED WITH SP2 IAW MOC & SPIB.SDR UALA2013070104565Cover · unsecurePAX & CREW TRIPPING ON SEAM OF RUBBER FLOORING-CARPET BY MID GALLEY. SURFACE NOT SMOOTH. REMOVED STRIPPING AT FWD AND AFT ENDS OF MID GALLEY FLOOR MAT AND INSTALLED DOUBLE BACK TAPE AND CLEAR MYLAR OVER IAW ECRA 2533-01004 AND TRM 25-33-01-004.SDR DALA13033109209Oven · smokeFLIGHT CREW COMPLAINED OF ODOR AND SMOKE COMING FROM GALLEY OVEN. R & R FORWARD GALLEY OVEN. OPS CHECKS GOOD.SDR UALA2013062804537Relay · faultyF/A REPORTED AFT CIRCUIT BREAKER PANEL MAKES CLICKING NOISE AND CHILLERS CYCLING ON AND OFF. CHILLER M31 CYCLING ON & OFF. VERIFIED AWM 25-33-01, SHEET 1 & FOUND TR 9010ML3 FAULTY. REPLACED TR 9010ML3, NO HELP. STILL CLICKING ON AND OFF. INSTALLED NEW CHSDR DALA13033249232Oven · inoperativeFORWARD GALLEY OVEN, SMALL AMOUNT OF SMOKE OMITTED VERY HOT. OVEN OFF. INSPECTED FORWARD GALLEY OVEN AND CIRCUIT BREAKER PANEL. NO TROUBLE FOUND. PULLED FOWARD GALLEY OVEN CIRCUIT BREAKER AND ISOLATED OVEN. OVEN IS NOW COOL WITH NO POWER TO IT FWD TO NEFSDR AALA20130624003Oven · dirtySMOKE IN FIRST CLASS GALLEY. EMERGENCY DECLARED FLIGHT RETURNED TO CCS LANDED WITHOUT INCIDENT. FOUND FIRST CLASS GALLEY AREA OVEN WITH DEBRIS INSIDE OF GALLEY GRILLS. PLACARDED BOTH FIRST CLASS GALLEY OVEN IAW NEF 25-33A AUTH 6-967NEF-C. REPLACED FIRST CLSDR USAA2013062500001Oven · overheatedOVEN 1 IN AFT GALLEY HAD AN OVERHEAT & BURNING SMELL. MX R & R NR 1 OVEN IN AFT GALLEY. OPS CHECK IS GOOD.SDR USAA2013062400011Unknown · smokeF/A SMELLED AN ELECTRICAL ODOR AND SAW SMOKE IN FORWARD GALLEY. DURING TROUBLESHOOTING, CIRCUIT BREAKER "GALLEY CONTROLLER" S-28 TRIPPED. REPLACED FWD GALLEY CHILLER IAW AMM 25-34-51-401. VENDOR COULD NOT CONFIRM FAILURE. CHILLER CAME BACK NO FAULT FOUND.SDR USAA2013062400024Unknown · arcedDURING THE BOARDING PROCESS, F/A AND AGENT BOTH SAW AND HEARD ELECTRICAL POP AND FLASH COMING FROM THE COFFEEMAKER AREA IN FORWARD GALLEY. NO CIRCUIT BREAKERS WERE POPPED. MX RAN FORWARD GALLEY OVEN AND BREWED COFFEE. NO DEFECTS NOTED. NO CIRCUIT BREAKERS TRSDR USAA2013062400003Oven · odorEN-ROUTE, FIRST CLASS OVENS HAVE STRONG OVEN CHEMICAL SMELL. R & R FWD GALLEY OVENS.SDR DALA13031455650Oven · damagedOVENS DAMAGED AND INOPERATIVE. CIRCUIT BREAKER PULLED AFTER A SMALL AMOUNT OF SMOKE CAME OUT. CLEANED OVEN. RAN ON HIGH FOR 15 MINUTES. NO SMOKE NOTICED. OK FOR SERVICE.SDR CA130621005Coffeemaker · inoperative(CAN) SHORTLY AFTER DEPARTURE THE CREW NOTICED HAZY SMOKE AND AN ELECTRICAL SMELL FROM THE LT COFFEEMAKER. THE CB`S FOR BOTH COFFEEMAKERS WERE PULLED AND THE SMOKE AND ODOR CLEARED. MAINTENANCE INVESTIGATION FOUND THAT THE LT COFFEEMAKER WOULD NOT BREW ON THESDR DALA13031389262Oven · smokeFORWARD GALLEY OVEN BEGAN TO SMOKE. CREW PULLED CIRCUIT BREAKER (F203) IN GALLEY AND IT STOPPED. PLACARD INSTALLED. MX OPERATED OVEN ON HIGH FOR OVER 20 MINUTES. COULD NOT DUPLICATE. OPS CHECKS NORMAL. OK FOR SERVICE.SDR UALA2013061904235Oven · smokeSMOKE IN CABIN. REPLACED OVEN ASSY. REPLACED RECIRCULATION FILTERS IAW AMM.SDR USAA2013061700027Chiller · faultyCREW REPORTED A MODERATE ELECTRICAL BURNING ODOR IN AFT GALLEY. MX R & R THE AFT CHILLER. OPS CHECK GOOD IAW AMM 25-34-51, PB 401.SDR ASAA2013061095063Oven · dirtyFUMES AND SMOKE CAME OUT OF OVEN IN AFT GALLEY, QUICKLY DISSIPATED WHEN TURNED OFF. MAY HAVE BEEN SOMETHING SPILLED ON RACK IN OVEN. ACFT GROUNDED. CLEANED AFT GALLEY OVEN NR 2 LEFT SIDE AND OPERATED IAW AMM TASK 25-32-0. NO SMOKE OR FUMES NOTED. OPERATES ATSDR USAA2013053000001Oven · malfunctionedF/A AND PASSENGERS SAY DARK SMOKE CAME FROM VENTS IN ROW 5 AND 6 AND MOVED THROUGH CABIN TO AFT GALLEY NO SMELL OR INDICATION OF SMOKE WERE DETECTED ON THE FLIGHT DECK. INSPECTED AND FOUND FORWARD GALLEY OVENS TO BE THE SOURCE OF SMOKE. PLACED GALLEY OVENS ON SDR ANCF2013042900159Oven · malfunctionedDURING CLIMB, OVEN NR 1 STARTED PRODUCING SMOKE, PROCEDURE WAS MADE AND C/B WAS PULLED, SMOKE STOPPED AFTER THIS IAW AMM 25-35-19-000-803. THE OVEN NR 1 WAS REMOVED AND INSP AND AMM 25-35-00-PB 001 WAS INSTALLED AND CLEANED, TEST OPS OK.SDR YENA20130523109Coffeemaker · overheatedFLT 1004 JFK-BOS, CREW REPORTED HOT ELECTRICAL SMELL IN FWD GALLEY. FOUND NR 1 COFFEEMAKER OVERHEATING REMOVED AND REPLACED BOTH COFFEEMAKERS IAW MM 25-30-00. NO DEFECTS NOTED AT THIS TIME.SDR UALA2013052203557Oven · contaminatedOVEN R31 SMOKING FROM LOWER SIDE, PLASTIC LOOKS BURNED. CLEANED DEBRIS. REPLACED R31 OVEN. OPS CHECKED NORMAL IAW AMM.SDR USAA2013052100001Coffeemaker · odorELECTRIC BURNING ODOR BY MID GALLEY EXPRESSO MAKER LT. MX R & R MID GALLEY ESPRESSO MAKER NR 2. OPS CHECKED OK.SDR USAA2013052100003Coffeemaker · smokeMID GALLEY RT ESPRESSO MAKER SMOKING. MX R & R MID GALLEY RT ESPRESSO MAKER.SDR UALA2013052103497Joint · looseAFT GALLEY RUBBER FLOOR JOINT LOOSE. RE-SEALED AFT GALLEY FLOOR JOINT.SDR UALA2013050803233Coffeemaker · leakingCOFFEE MAKER LEAKING. DR-1R FWD-CABIN FWD GALLE. CREW COMMENTS: COFFEEMAKER SPEWS WHEN DISPENSES (1ST CLASS GALLEY). REMOVED AND REPLACED FWD GALLEY COFFEEMAKER PER AMM 25-32-96, MAKER OPERATIONAL AND LEAK CHECKS GOOD.SDR CA130507006Coffeemaker · overheated(CAN) FLIGHT CREW REPORTED THAT JUST PRIOR TO REACHING THE GATE THAT THE F/A THOUGHT SHE COULD SMELL SMOKE COMING FROM THE REAR-LEFT COFFEEMAKER. SHE TURNED OFF THE COFFEEMAKER AND THE ODOR WENT AWAY. THE SUSPECT COFFEEMAKER WAS REPLACED IAW CMM 25-31-101 ANSDR USAA2013050600014Coffeemaker · malfunctionedCREW REPORTED A SMELL IN FORWARD GALLEY - SMELLS CHEMICAL OR ELECTRICAL IN NATURE. MAINTENANCE INSPECTED FORWARD GALLEY AND FORWARD BAG BIN - HAD CLEANER DISINFECT TRASH BIN AREA. PERFORMED T/S PER CARD 26L00021001. REMOVED AND REPLACED FORWARD GALLEY COFFESDR USAA2013042900010Spring · failedAFT GALLEY TRASH FLAP NOT CLOSING. REPLACED SPRINGS ON AFT GALLEY TRASH FLAP.SDR UALA2013043003022Coffeemaker · odorSTRONG BURNING ODOR COMING FROM FWD GALLEY COFFEEMAKER. REMOVED COFFEEMAKER & ODOR DISAPPEARED. INSTALL NEW COFFEEMAKER. WORKED NORMAL, NO ODOR.SDR SIMA20130426005Coffeemaker · faultyON FLIGHT 2788 THE CREW REPORTED A BURNING SMELL IN GALLEY. A PRONG ON THE BACK OF COFFEE JUG APPEARED BLACKENED. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE COFFEE JUG. THE OPERATIONAL CHECK WAS GOOD, NO SMELL NOTED AFTER REPLACED PER SDR USAA2013042500006Chiller · failedPRIOR TO BOARDING, SMOKE WARNING IN LAVATORY. CABIN FILLED WITH SMOKE. SHUTDOWN ACFT AND EVACUATED. NO FIRE NOTED IN LAVATORY. FORWARD GALLEY AIR CHILLER FAILED. REMOVED AND REPLACED FORWARD GALLEY AIR CHILLER UNIT IAW MM 25-34-51-400.SDR HNAA2013042400234Socket · burnedF/A SELECTED GALLEY LIGHT ON, WHICH WAS FOLLOWED BY SMOKE IN GALLEY AREA. INSPECTED GALLEY LIGHT ASSY. NO DEFECTS, BUT FOUND HOT JUG LID NOT SECURED PROPERLY AND HOT JUG SOCKET BURNED. R & R HOT JUG AND SOCKET ASSY. OPS CHECKED GOOD. ALSO PERFORMED HIDDENSDR UALA2013042302805Oven · overheatedAFT GALLEY OVEN OVERHEATED. REPLACED R53 OVEN PER MM 25-32-02 AND W51, W52 WARMING OVENS. INSPECTED OVERHEAD DUCTS AND ORIFICES. FOUND SECURE AND CLEAN. RAN PACKS AND CHECKED SUPPLEMENTAL HEATING. ALL NORMAL.SDR UALA2013041902702Oven · dirtyFIRST CLASS OVEN LOC-012 SMOKES - GREASE INSIDE. CLEANED OVEN INSIDE. OPN CHECK OK. NOT ANY SMOKE NOTED WITH OPN CHECK.SDR R61A201304150422Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLEY HALVE TRIM CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFT GALLEY HALVE TRIM IAW EMB 170 AMM 25-00-23. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201304150421Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLEY HALVE TRIM CORRODED. MAINTENANCE REMOVED AND REPLACED THE TRIM IAW EMB 170 AMM 25-00-23. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201304150420Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLET HALVES TRIM CORRODED. MAINTENANCE REMOVED AND REPLACED TRIM IAW EMB 170 AMM 25-00-23. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR ASOA20130415036Coffeemaker · odorF/A REPORTED THE LT COFFEEMAKER PRODUCED A BURN SMELL. MX REMOVED PLASTIC DEBRIS FROM COFFEEMAKER HOT PLATE AS NECESSARY. PERFORMED OPS CHECK SUCCESSFUL. NO FURTHER EVIDENCE OF BURN SMELL. ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR YENA20130414071Coffeemaker · faultyFLT 52 MCO-JFK, F/A IN BACK GALLEY SMELLED WHAT THEY THINK IS AN ELECTRICAL SMELL INTERMITTENTLY. PERFORMED INSPECTION OF AFT GALLEY AFTER CREW REPORT SMELL IN AREA OF COFFEEMAKERS FOUND SMELL COMING FROM C/M NR 2 (508). BURNING SMELL COMING FROM REAR ELECT SDR ANCF2013041200155Oven · smokeNR 2 OVEN IN REAR GALLEY HAS A BURNING SMOKE. NR 2 OVEN REAR GALLEY WAS REMOVED AND REPLACED IAW AMM 25-35-19-PB 401.
Back to JASC 2530