Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR UALA2013041102450Oven · inoperativeCENTER OVEN IN AFT GALLEY IS INOPERATIVE, WILL NOT POWER UP. REPLACED OVEN IAW AMM, OPS CHECKED OKAY.SDR UALA2013041002411Oven · unknownAFT GALLEY ISSUE, FLIGHT DIVERTED. OVEN INOPERATIVE, WILL NOT POWER UP. SUSPECT OVERHEATED. REACTIVATED SUPPLEMENTAL HEATING SYSTEM REF MM 21-45-00, OPS CHECKED GOODSDR QXEA2013040700765Switch · failedELECTRICAL BURNING ODOR AT THE AFT GALLEY HOT JUG AREA. C/W MCN 62172-01. NOTICED RT OVERHEAD LIGHT SWITCH WAS NOT ILLUMINATING BUT LIGHT WAS OPERATING NORMALLY. REMOVED SWITCH AND REPLACED WITH NEW. OPS CHECKED GOOD IAW AMM 25-34-00-710-801. NO BURN ODOSDR USAA2013040800018Chiller · defectiveTWO FLIGHT ATTENDANTS REPORTED FEELING LIGHT HEADED DUE TO POSSIBLE FUMES - SCORCHED FABRIC SMELL. ACCOMPLISHED AIR QUALITY TROUBLESHOOTING AND FOUND AFT GALLEY AIR CHILLER TO BE DEFECTIVE. REMOVED AND REPLACED AFT GALLEY AIR CHILLER IAW MM 25-34-51-401.SDR UALA2013040802321Oven · faultyOVEN 407 HEAT IS ON WITH CIRCUIT BREAKER PULLED AND SWITCH OFF AFT GALLEY. REPLACED OVEN ASSY.SDR UALA2013040502285Oven · malfunctionedOVEN 110 SMOKES. REMOVED AND REPLACED OVEN AT POS. 110, FUNCTION TESTED ALL OKAY.SDR CALA2013040500201Coffeemaker · sparksCOFFEE POT FORWARD GALLEY SPARKED. SMOKED & STRONG ELETRICAL ODOR. R & R IAW AMM 25-34-00.SDR SWAA2013040414489Coffeemaker · faultyBURNING SMELL FROM AFT GALLEY COFFEEMAKER. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR 2013FA0000207Line · disconnectedCOFFEEMAKER FAILED AND LEAKING WATER. ON FURTHER INVESTIGATION, NOTICED THAT ONE OF THE WATER LINES HAD COME OFF AND AN ELECTRICAL CONNECTOR WAS MELTED AND CHARED.SDR DXTA2013040105347Heating Element · failedWHEN OVENTURNED, HEATING ELEMENT PRODUCED SMOKE AND A SMALL FLAME. VISUALLY INSPECTED BOTTOM HEATING ELEMENTS, NO GREASE NOTED ON ELEMENT. TURNED OVEN ON AND NOTED EXCESSIVE SMOKE FROM BOTTOM OF OVEN IN GALLEY. REPLACED OVEN, OPS CHECK GOOD IAW CMP 253012.SDR UALA2013032802020Mount Bracket · crackedFOUND CHILLER NR 11 AT FIRST CLASS MOUNTING BRACKET IS CRACKED AT FWD RIGHT SIDE. REMOVED FOR REPAIR. INSTALLED BRACKET AND CHILLER, OP CHECKED OKAY.SDR DALA13013489226Coffeemaker · dirtyEXPERIENCED SLIGHT HAZE AND ODOR IN R1 GALLEY APPROXIMATELY 40 MINUTES INTO FLIGHT. COFFEE POTS TURNED OFF AND CIRCUIT BREAKERS PULLED WITH NO EFFECT. COCKPIT GALLEY POWER WAS TURNED OFF AND HAZE/ODOR DISSIPATED. MX FOUND BURNED DEBRIS ON BOTTOM OF COFFEE SDR UALA2013032501861Chiller · inoperativeGALLEY CHILLER INOPERATIVE. REMOVED AND REPLACED GALLEY CHILLER. OPS CHECKED NORMAL.SDR YENA20130324065Coffeemaker · malfunctionedFLT 545 EWR-PBI, CREW REPORTED COFFEEMAKER NR 2 PRODUCED SOME SMOKE WHILE BREWING. COFFEEMAKER WAS TURNED OFF. REMOVED AND REPLACED FWD GALLEY NR 2 COFFEEMAKER IAW AMM 25-35-00. OPS AND LEAK CHECK GOOD.SDR CALA2013032500172Circuit Breaker · trippedWHEN FWD GALLEY NR 204 WAS SELECTED TO ON, BOTH OVEN RT AND OVEN LT CIRCUIT BREAKERS TRIPPED.SDR ASAA2013032294248Oven · odorF/A REPORT THAT THEY DETECTED AN ODOR, POSSIBLY ELECTRICAL COMING FROM THE MIDDLE OVEN IN THE AFT GALLEY. TURNED OVEN OFF AND ODOR STOPPED. TURNED OVEN ON BUT IT WOULD NOT COME ON. SEVERAL MINUTES LATER OVEN CAME ON. ODOR RETURNED. TURNED OVEN OFF, AND OSDR SWAA2013032013857Coffeemaker · malfunctionedDIVERSION -- LOUD BANG IN AF GALLEY WITH WHITE SMOKE. REMOVED AND REPLACED COFFEEMAKERS PER MM.SDR ASAA2013031794212Oven · odorF/A REPORT ELECTRICAL ODOR IN CABIN AT ROWS 18, 19, & 20 DEF. ALL CABIN LIGHTS TURNED OFF & ODOR PERSISTED BUT NOT INCREASING IN INTENSITY. NO STOWED ELECTRONIC DEVICES OVERHEATING, NO OVERHEATING PSUS. ACFT GROUNDED. ACFT GROUNDED. OPENED CEILING PANELSDR SWAA2013031913775Coffeemaker · faultyAIR TURNBACK - ON CLIMBOUT, BURNING WIRE SMELL FROM FWD GALLEY AREA. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR AALA20130308010Oven · malfunctionedSTL - INFLIGHT DFW-CMH. CREW REPORTED SMOKE IN CABIN COMING FROM FORWARD GALLEY OVEN. EMERGENCY DECLARED FLIGHT DIVERTED STL LANDED WITHOUT INCIDENT. DEFERRED FORWARD GALLEY OVEN PER NEF. FLIGHT CONTINUED TO DESTINATION. SYSTEM GROUND CHECK NORMAL OPERATISDR UALA2013030601340Line · looseWATER PUMP IN AFT GALLEY MAKING LOUD NOISE. REMOVED COFFEEMAKER. SECURED LOOSE LINE. DRAINED SOME WATER AND AIR. OP CHECK OK FOR SERVICE.SDR UALA2013030401262Oven · smokeBURNING ELECTRICAL ODOR EMANATING FROM GALLEY OVEN. REMOVED LINER, COULD NOT FIND CAUSE OF ODOR. REPLACED OVEN. OPS CHECKED GOOD.SDR UALA2013030101228Vent Line · leakingAFT GALLEY HAS WATER ON FLOOR AGAIN. REMOVED AFT COFFEEMAKERS. VENT LINE HAS CONSTANT DRIP WITH WATER SUPPLY ON. BLED SYSTEM, NO HELP. AFT GALLEY WATER SUPPLY SHUT OFF AND INSTALLED COFFEEMAKERS. MOPPED UP WATER RESIDUE AS NEEDED. COMPLIED WITH MEL, PLASDR DALA1305570664Coffeemaker · odorELECTRICAL ODOR COMING FROM AFT GALLEY. PERFORMED ACFT SMOKE AND FUME QUESTIONARE. ELECTRICAL ODOR FROM AFT COFFEEMAKER NR 1. REMOVED COFFEEMAKER, ODOR DISSAPATED. INSPECTED COFFEEMAKER COMPARTMENT AND CONTROL PANEL COMPARTMENT NO DISCREPANCY NOTED. RESDR R61A201302220259Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLEY HALVES CORRODED. MAINTENANCE REMOVED AND REPLACED AFT GALLEY TRIM IAW EMB 170 AMM 25-00-23 AND 20-10-01. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201302220258Bracket · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLEY HALVES HAVE CORROSION. MAINTENANCE REMOVED AND REPLACED THE AFT GALLEY SPLIT JOINT BRACKET IAW EMB 170 AMM 25-00-23 AND 20-10-01. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR R61A201302220257Trim Panel · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE AFT GALLEY HALF TRIM PANELS CORRODED. MAINTENANCE REMOVED AND REPLACED THE AFT GALLEY TRIM IAW EMB 170 AMM 25-00-23 AND 20-10-01. THE AIRCRAFT IS OUT OF SERVICE IN HR\EAVY CHECK.SDR AALA20130214012Oven · overheatedIAD - INFLIGHT DCA-DFW. CREW REPORTED FIRST CLASS GALLEY OVEN OVERHEATED CAUSING SMOKE IN CABIN. EMERGENCY DECLARED FLIGHT DIVERTED IAD LANDED WITHOUT INCIDENT. PLACARD FIRST CLASS GALLEY OVEN PER MEL. FLIGHT CONTINUED TO DESTINATION. REPLACED FORWARD GASDR USAA2013021300002Oven · malfunctionedCREW REPORTS NR 1 OVEN UNUSABLE. SMOKE DURING WARM-UP. MISSING INSERT. MAINTENANCE REMOVED AND REPLACED NR 1 OVEN.SDR DALA1303410127Coffeemaker · damagedDOOR 2L COFFEEMAKER DAMAGED AND INOPERATIVE. COFFEEMAKER SPARKING FROM SIDES. COFFEEMAKER REMOVED IAW ERA 511387-14. BOLT SHEARED OFF. C/BS COLLARED AND WIRES SECURED.SDR USAA2013020600026Oven · sparksFLT 710, EN ROUTE. AFT GALLEY OVEN AT BS 201 HAD SPARKS AT CONNECTOR. OVEN WAS TURNED OFF. GALLEY CART REPLACEDSDR USAA2013020600027Service Cart · malfunctionedPHL - FLT 751 EN ROUTE BRU TO PHL. AFT GALLEY OVEN AT STATION A-301 SMOKES WHEN ON. TURNED OVEN OFF-SMOKE STOPPED. CONDUCTED A GVI OF ACCESSABLE SECTIONS OF POWER CABLE TO OVEN. REMOVED AND REPLACED THE GALLEY OVEN CART.SDR USAA2013020600025Controller · faultyPHL - FLT 751 EN ROUTE BRU TO PHL. AFT GALLEY OVEN AT STATION A-301 SMOKES WHEN ON. TURNED OVEN OFF-SMOKE STOPPED. CONDUCTED A A GVI OF ACCESSABLE SECTIONS OF POWER CABLE TO OVEN. REMOVED AND REPLACED THE OVEN CONTROLLER.SDR UALA2013020100590Stop · detachedCONTAINER REAR STOP BLOCK DETACHED LOCATION 402, LEFT SIDE OF BUS GALLEY. RESECURED STOP BLOCK.SDR USAA2013020100013Coffeemaker · defectiveCOFFEEMAKER MADE AN ARCING SOUND WITH A BURNT ELECTRICAL SMELL. SMELL DISSIPATED AFTER TURNING OFF COFFEEMAKER. MAINTENANCE REMOVED AND REPLACED BOTH FORWARD GALLEY COFFEEMAKERS.SDR R61A201301290139Bracket · corrodedWHILE AIRCRAFT WAS IN HEAVY CHECK MAINTENANCE FOUND THE FORWARD HALF OF AFT GALLEY UNION CORRODED. MAINTENANCE REMOVED AND REPLACED THE SPLIT JOINT BRACKET IAW EMB 170 SRM 51-40-00. THE AIRCRAFT IS OUT OF SERVICE IN HEAVY CHECK.SDR SCNA20130208050Retainer · crackedG2 GALLEY CURTAIN ASSY UPPER RETAINER IS CRACKED. LOCATED OUTSIDE R1 DOOR. REPLACED RETAINER & INSTALLED ON FORWARD GALLEY HEADER (G1 GALLEY CURTAIN ASSY).SDR ASMF201303006Connector · out of positionCAPTAIN REPORTED THAT DURING CLIMB AN ELECTRICAL CABLE BURNED ODOR WITH NO EVIDENCE OF SMOKE, DISAPPEARING DURING CLIMB. MX PERSONNEL PERFORMED FIM 21-00, TASK 806 PROCEDURE AND SMOKE OR FUMES IN CABIN CONDITIONAL INSPECTION IAW MM 05-51-56, DETECTING A FORWASDR USAA2013011800008Chiller · faultyFLIGHT ATTENDANT REPORTED FORWARD GALLEY CHILLER NOT COOLING AND HAS METALLIC ODOR. REMOVED AND REPLACED CHILLER.SDR CHQA20130112011Coffeemaker · odorCREW REPORTED AN INTERMITTENT BURNING RUBBER SMELL IN THE FORWARD GALLEY DURING FLIGHT. MAINTENANCE ISOLATED THE SMELL TO THE COFFEE BREWERS AND DEFERRED THE ITEM. ON 01/13/2013 THE COFFEE BREWERS OPERATIONALLY CHECKED GOOD, CLEARING THE DEFERRAL.SDR USAA2013011000001Oven · dirtyFLIGHT ATTENDANTS REPORTED A CABIN ODOR ORIGINATING FROM FORWARD GALLEY THAT CAUSED EYE IRRITATION. FLIGHT CREW COULD DETECT FAINT ODOR THAT QUICKLY DISSIPATED. MAINTENANCE FOUND BURNT PLASTIC IN FORWARD GALLEY OVEN. REMOVED AND REPLACED OVEN.SDR SWAA2013010411116Coffeemaker · failedWIRE BURNING SMELL FROM COMPARTMENT NEXT TO COFFEEMAKER. REPAIRED COFFEEMAKER PER MM.SDR USAA2013010200008Oven · dirtyFIRE IN AFT GALLEY OVEN, NEED TO HAVE GREASE CLEANED OUT. MAINTENANCE - ALL THREE OVENS FIRMLY CLEANED.SDR DALA12017259230Oven · odorON APPROAXCH, F/A REPORTED SMOKE ODOR COMING FROM FORWARD GALLEY CENTER CEILING AREA. LIGHTS WERE OFF AT THE TIME. CREW SHUTOFF GALLEY POWER AND F/A REPORTED ODOR DISSIPATED A FEW MINUTES LATER. MX RAN GALLEY, LIGHTS, COFFEEMAKERS AND OVEN. ODOR OF HOT FOODSDR UIEA2012122300559Oven · smokeEICAS MESSAGE ELEC UTIL BUSS RT WITH SMOKE REPORTED IN UPPER DECK GALLEY BY F/A. RETURNED TO GATE. FOUND OVEN SMOKING AT POSITION UG19. OVEN CIRCUIT BREAKER FOUND TRIPPED.SDR UALA2012122407397Structure · exposedGALLEY 303 HAS BARE METAL EXPOSED. REMOVED THE SHARP EDGE AND COULD NOT BREAK THE MFG PART NUMBER TO PCN. INSTALLED SPEED TAPE. MFG PART NUMBER J1240A08GO1. REINSTALLED THE MISSING RIVET THEN RESEALED THE AREA. NO METAL EXPOSED AT THIS TIME. ALL WORK WASSDR USAA2012122400001Oven · overheatedSINGLE OVEN 7-12 AIRCRAFT LEFT AFT GALLEY OVER HEATED ON MEDIUM IN 15 MINUTES, VERY SMOKEY, VERY HOT. MAINTENANCE REPLACED OVEN, OPERATIONAL CHECK IS GOOD.SDR SIMA20121220004Coffeemaker · shortedON FLIGHT 4326 THE CREW REPORTED ON TAXI OUT THEY NOTICED AN ELECTRICAL BURNING SMELL AND THE FLIGHT ATTENDANT ADVISED SHE SAW A MIST COMING FROM THE BULKHEAD IN FRONT OF ROW 3. THE CREW PERFORMED THE CABIN/COCKPIT FIRE/FUMES CHECKLIST AND TOLD THE GROUND THESDR CALA2012121900865Coffeemaker · odorF/A IN AFT GALLEY STATED THEY SMELLED STRONG BURNING ODOR AFTER PUSH ENG START. DESCRIBED ODOR AS A SMOKEY WOODY. ACCOMPLISHED CONDITIONAL INSPECTION TASK 05-51-58-910-801C1. FOUND BLACKENED CLUMPS OF COFFEE GRINDS AND PAPER UNDER AFT GALLEY COFFEEMAKER HEARSDR ASOA20121217157Coffeemaker · smokeAFTER TAKEOFF THE CREW RPEORTED SMOKE IN THE CABIN. THE ACFT RETURNED TO LIT WHERE IT LANDED WITHOUT INCIDENT. UPON INSPECTION THE SOURCE OF THE SMOKE WAS FOUND TO BE THE COFFEEMAKER WHICH WERE DEFERRED UNDER AN NEF AND THE ACFT WAS RETURNED TO SERVICE.
Back to JASC 2530