SDR ASOA201217119Coffeemaker · smokeDIVERTED, CREW REPORTED SMOKE IN CABIN, STRONGEST IN GALLEY AREA. CONTRACT MX INSPECTED GALLEY AREA AND FOUND COFFEMAKERS TO BE THE CAUSE OF THE SMOKE. R & R THE INBD COFFEEMAKER ASSY WITH OPS CHECKED SUCCESSFUL.SDR SWIA201232356Coffeemaker · faultyNR 2 COFFEEMAKER HAS ELECTRICAL BURNING SMELL. (FLT 5429) REPLACED NR 2 COFFEEMAKER IAW AMM.SDR AALA20121214001Oven · inoperativeLHR - CREW REPORTED OVEN 4B HAS BURNING PLASTIC SMELL AND OVERHEATS WHILE IN USE. FLIGHT LANDED LHR WITHOUT INCIDENT. DEFERRED OVEN 4B INOPERATIVE PER NEF. REPLACED OVEN 4B AT JFK ON 12/17/2012. SYSTEM GROUND CHECK NORMAL OPERATION.SDR UALA2012121407236Oven · contaminatedBURNED PLASTIC SMELL IS EMANATING FROM FORWARD GALLEY OVENS. REMOVED BURNT PLASTIC MATERIAL FROM OVEN, RAN OVEN 12 MINS, OPS CHECK NORMAL.SDR CALA2013121393678Chiller · faultyCHILLER C31 POPS CB WITH MEL 2520NB. PULLED & COLLARED CB. CHILLER IS MID GALLEY FWD SECTION. REPLACED MID GALLEY CHILLER POS C31 IAW AMM, OPERATIONS CHECKED NORMAL.SDR UALA2012121407220Oven · failedUPPER DECK OVEN NR 2 DOES NOT HEAT, AND IT ALSO MAKES GROWLING NOISE. REPLACED OVEN IAW AMM 25- 32-97. OPS CHECKED OK.SDR SWAA2012121010372Coffeemaker · faultySMOKE & FUMES IN GALLEY. REMOVED AND REPLACED COFFEEMAKER PER M/M.SDR UALA2012120406945Actuator · faultyCART LIFT INOP, BOTH LIFT MOTORS OVERHEAT AT SAME TIME, BURNT OIL SMELL COMING FROM COMPARTMENT. REPLACED BOTH MOTORS AND ACTUATOR IAW AMM 25-38-02. OPS CHECK NORMAL.SDR SIMA20121129001Coffeemaker · faultyON FLIGHT 3661 EN ROUTE TO LAX FA REPORTED AN ODD ODOR IN THE CABIN. CAPT NOTICED THE ODOR. INSTRUCTED FA TO ADVISE HIM IF THE ODOR CHANGED OR INTENSIFIED. FA CALLED BACK AND ADVISE THAT THE ODOR WAS STRONGER AROUND ROW 10. FA QUESTIONED SOME PAX AND CHECKSDR SWAA2012112901042Coffeemaker · faultyDEPARTURE F/A CREW REPORTED BOTH AFT COFFEEMAKERS SHUTDOWN WITH ACCOMPANYING "ELECTRICAL" ODOR. REMOVED & RESEATED BOTH COFFEEMAKERS PER AMM.SDR CALA2012112600822Oven · defectiveSMOKE AND BURNING ODOR COMING FROM OVEN IN FRONT GALLEY COMPLIED WITH AMM TASK 05-51-58-910-801C1 FOR FWD GALLEY COMPONENTS WITH OVEN 204 AT FAULT. ALL OTHER COMPONENTS OPS NORMAL. REPLACED OVEN. OP`S CHECKED GOOD.SDR USAA2012112100001Coffeemaker · faultySTRONG ELECTRICAL SMELL NEAR VIDEO SYSTEM. MAINTENANCE TROUBLESHOOT CABIN AIR QUALITY. RAN BOTH ENGINES AND APU NO ODOR NOTED. INSPECTED GALLEYS AND LAVS AND CABIN AREA. REPLACED MID GALLEY COFFEEMAKER DUE TO BURNING ODOR. NO OTHER ODORS NOTED. REPLACED SDR DALA12014079257Coffeemaker · contaminatedFLIGHT CREW REPORTED A BURNING ODOR FROM COFFEEMAKERS BY THE L1 DOOR. COFFEEMAKERS TURNED OFF. ODOR DISSIPATED. MX FOUND PLASTIC CUP RESIDUE ON LOWER COFFEE DISPENSER HOT PLATE. CLEANED DEBRIS AND ALL RESIDUE. OPS CHECKS GOOD. ALL NORMAL.SDR UALA2012111406548Chiller · noisyM11 FIRST CLASS CHILLER NOISY. VIBRATES ENTIRE GALLEY AND LAV AREA. REPLACED C11 CHILLER PER AMM.SDR UALA2012111406556Structure · damagedG1 AND G4 GALLEYS HAVE HEAT DAMAGE BEHIND WORK LIGHTS. GALLEYS WERE REFURBISHED AT HMV2 VISIT PER JD-CE-40-25-30-02-JD1.SDR DALA1254110129Chiller · inoperativeFUMES IN AFT GALLEY REPORTED BY FLIGHT CREW. LEFT AFT CHILLER INOPERATIVE, AFT LT CHILLER CONTROL CIRCUIT BREAKER COLLARD.SDR ASOA20121102099Coffeemaker · odorF/A REPORTED ELECTRIC BURNING ODOR WITH VISIBLE SMOKE IN GALLEY ON CLIMBOUT. F/A PULLED COFFEEMAKER BREAKERS AND ODOR AND SMOKE CLEARED. MX INSPECTED BOTH COFFEEMAKERS FOR BURN MARKS. NONE FOUND. CLEANED BOTH HOT PLATES OF COFFEE STAINS AND LIQUID. BREWEDSDR ASAA2012110293234Coffeemaker · smokeF/A REPORTS THAT THE FWD GALLEY NR 2 COFFEEMAKER BEGAN SPARKING AND SMOKING. CIRCUIT BREAKER FOR COFFEEMAKER 2 TRIPPED. COFFEEMAKER WAS TURNED OFF. NO FURTHER PROBLEMS. CIRCUIT BREAKER LEFT OPEN. R & R FWD GALLEY NR 2 COFFEEMAKER. DETERMINED CIRCUIT BREAKSDR SWAA2012110509025Coffeemaker · faultyPRIOR TO 10,000FT, F/A CALLED & SAID SMELLED STRONG ODOR WHICH SEEMED TO BE SOMETHING BURNING. AFTERWARD, WE BOTH SMELLED A STRONG ODOR IN THE COCKPIT. TURNED GALLEY POWER OFF AND SMELL DISSIPATED. NO SMOKE NOTED AND SMELL SEEMED TO BE ELECTRICAL. REMOVED SDR DALA12012089205Coffeemaker · odorEXPERIENCED FUMES IN CABIN. FLIGHT CREW SMELLED A PLASTIC ODOR WITH NO ASSOCIATED SMOKE AFTER TAKEOFF IN THE FORWARD GALLEY. GALLEY POWER WAS TURNED OFF AND THE ODOR DISSIPATED. MX FOUND THE FORWARD GALLEY COFFEEMAKER AT FAULT. R & R SAME.SDR CALA2012103100687Oven · odorB ZONE GALLEY OVEN POSITION 405 WHEN COOKING MEALS, OVEN EMITS BURNING ODOR. OPINON IS THAT ODOR IS ELECTRICAL. TESTED OVEN COULD NOT DUPLICATE PROBLEM. REPLACED OVEN IAW DMC-B787-A-25-32-00-10A-720A-A & TESTED IAW DMC-B787-A-25-32-00-11A-320A-A . OPS NORMSDR UALA2012102206035Coffeemaker · sparksCREW REPORTED WHEN FLT ATTENDANT MOVED LEVER ON COFFEEMAKER M51 IN RT AFT GALLEY TO REMOVE BREW TRAY, COFFEEMAKER SPARKED AND LIGHT SMOKE NOTICED. FLIGHT ATTENDANT PULLED C/B FOR M51 AT RIGHT AFT GALLEY POWER CONTROL PANEL. NO FURTHER SMOKE OR SPARKS NOTICEDSDR AALA20121022003Oven · inoperativeLHR - CREW REPORTED OVEN 9C OVERHEATED AND SMELLED OF ELECTRICAL ODOR. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED OVEN 9C AT DFW ON 10/24/2012. SYSTEM GROUND CHECK NORMAL OPERATION.SDR UALA2012101905986Oven · contaminated19HJK REPORT OF STRONG ELECTRICAL OR PLASTIC BURNING SMELL. PER CREW REPORT, UNABLE TO PINPOINT CAUSE OF ODOR VARIOUS COMPLAINTS WERE BODY ODOR, TOBACCO, PLASTIC SMELL. ALSO NOTICED BY POSITION DOOR 1L. CREW INDICATES NO SMOKE OR FIRE HAZARD. REQUEST SFOMMSDR AALA20121014005Oven · dirtyLHR - FLIGHT ATTENDANT REPORTED NUMBER ONE OVEN HAS BURNING SMELL AND SMOKES WHEN USED. FLIGHT LANDED LHR WITHOUT INCIDENT. FOUND BURNT FOOD IN FAN AREA OF NUMBER ONE OVEN. DEFERRED OVEN INOPERATIVE. REPLACED NUMBER ONE OVEN AT ORD ON 10/14/2012. SYSTEM GSDR AALA20121014008Oven · overheatedPHX - INFLIGHT MCO-LAX. CREW REPORTED FIRST CLASS OVEN OVERHEATED. FLIGHT ATTENDANT PULLED CIRCUIT BREAKER AND WALL STAYED HOT. EMERGENCY DECLARED FLIGHT DIVERTED PHX LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REMOVED FORWARD GALLEY OVEN AND SDR UIEA2012101400474Oven · inoperativeOVEN AT GALLEY G-02 STOP WORKING, FOUND EVIDENCE OF SMOKE AND CIRCUIT BREAKER POPPED. CIRCUIT BREAKER PULLED AND COLLARED.SDR UALA2012101505875Rail · looseCREW REPORTS SUBSTANTIAL WATER LEAK MID CABIN GALLEY POSSIBLE COFFEEMAKERS. CHECK GALLEY WATER LINE FOR LEAKS REF AMM. FOUND COFFEEMAKER RAIL ASSY LOOSE THAT HOLDS COFFEEMAKER IN PLACE LOOSE. REPLACED RAIL ASSY AND TIGHTENED. SECURED AND BREWED 2 POTS OF CSDR UALA2012101505877Drain · cloggedAFT GALLEY CARPET SOAKED. SOURCE UNKNOWN. INSPECTED FOR LEAKS AROUND NR 3 GALLEY, FOUND THE DRAIN FOR THE G3 CHILLER CLOGGED AND LEAKING IN COMPARTMENTS 301, 302, 303, THE CENTER AISLE, AND AFT RIGHT ROW OF SEATS. CLEANED CARPETS WITH WET-VAC AND MOPPED UP SDR UALA2012101105783Chiller · inoperativeFWD GALLEY CHILLER NR C11 INOPERATIVE. CHILLER HAS NO COOL AIR. REPLACED GALLEY CHILLER, OPS CHECKED GOOD.SDR CA121010002Oven · failed(CAN) THE FLIGHT DIVERTED DUE SMOKE IN THE FWD GALLEY, F/A USED FIRE EXTINGUISHER AS SMOKE WAS GETTING HEAVIER. THE FLIGHT CREW DID DECLARE A PANPAN FOR PRIORITY. THE SMOKE DISSIPATED PRIOR TO ARRIVAL. THE ACFT LANDED ABOVE THE MAXIMUM STRUCTURAL LANDING WEIGSDR ANCF2012100900132Oven · malfunctionedDURING TAXI BURNING SMELL WAS DETECTED ON AFT GALLEY (4 LEFT). IAW AMM TASK 25-35-00 WAS PERFORMED CHECK IN AFT GALLEY AND FOUND C/B OVEN NR 3 TRIPPED, OVEN NR 3 IS DEFERRED TO DMI /NEF NR 1158 AS PER MEL NEF II-5 CAT D.SDR UALA2012100805669Retainer · faultyFIRST CLASS GALLEY, QUARTER TURN FOR 116 HAS FALLEN OFF. THE SCREW IS SHEARED OFF IN NUT PLATE. NEED TO ORDER RETAINER (PCN 023-0131). REPLACED BLOCK AND LATCH ASSY.SDR CA121002001Controller · failed(CAN) PAN PAN DECLARED WITH ATC. IN DESCENT, F/A REPORTED ELECTRICAL ODOR IN FORWARD LT GALLEY OVEN. THE FLIGHT CREW CONFIRMED THE SMELL AND THE OVENS WERE POWERED OFF. VISIBLE SMOKE WAS SEEN NEAR THE OVENS DURING FINAL APPROACH. CFR AND MAINTENANCE INSPECTEDSDR USAA2012100300002Oven · defectiveFLIGHT 796, PHL - TLV - FLIGHT ATTENDANT REPORTED AFT GALLEY OVEN NR 2 POS 6-12 WAS EMITTING HIGH HEAT FROM FRONT SIDES AND TOP OF OVEN. LONG AFTER ELECTRICAL POWER WAS REMOVED AND CONTINUED TO INCREASE. FLIGHT ATTENDANT EXPENDED 1 FIRE EXTINGUISHER INSIDE OSDR DALA1249643756Oven · sparksDURING FLIGHT, THE FORWARD GALLEY OVEN BEGAN EMITTING SPARKS AND SMOKE. ACFT DIVERTED. MX FOUND OVEN MOTOR DAMAGED. PULLED AND SECURED OVEN CIRCUIT BREAKER. OVEN REPLACED AND ACFT RETURNED TO SERVICE.SDR DALA12009000911Coffeemaker · inoperativeTHE F/A REPORTED A BURNING WIRE ODOR IN THE GALLEY. THE QRH WAS COMPLIED WITH AND THE GALLEY POWER WAS SECURED. THE SMELL STOPPED ONCE THE POWER WAS TURNED OFF. NO VISIBLE SMOKE OR FLAME WAS EVER SEEN. MX FOUND THE LOWER COFFEEMAKER IN THE FWD GALLEY INOPERSDR CA120927006Socket · burned(CAN) BURNING ODOR IN FRONT FOUR ROWS. NO SMOKE, NO LIGHTS OUT, NO BURNED COFFEE. F/A SEEMS TO THINK ITS A PLASTIC ODOR. FOUND NR 2 COFFEE URN SOCKET BADLY BURNED, FORWARD GALLEY. REPLACED NR 2 COFFEE URN OUTLET. CHECKED SERVICEABLE, PN AC16371.SDR DALA1249491814Oven · smokeOVEN IN FWD GALLEY IS SMOKING. REPAIR ACCOMPLISHED.SDR UALA2012092405414Oven · smokeSMOKE FROM OVEN IN FWD GALLEY. 2 EXTINGUISHERS USED FIRE EXTINGUISHED. SMOKE DISSIPATED. REPLACED FWD GALLEY OVEN.SDR DALA12008250966Coffeemaker · sparksTHE PILOT REPORTS ONE COFFEE MAKER WAS EMITTING SPARKS AND CAUSED SMOKE IN THE GALLEY. THE COFFEEMAKER WAS REPLACED.SDR SWAA2012092107859Coffeemaker · faultyFORWARD COFFEE POT HAD DISTINCT ELECTRICAL ODOR. TURNED OFF POT AND ODOR DISPERSED. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR USAA2012091800001Oven · faultyFLIGHT ATTENDANT REPORTED BURNING SMELL COMING FROM OVEN 2 POSITION 4-3. IT WAS A PLASTIC SMELL AND CONFIRMED IT WAS NOT COMING FROM INSIDE THE OVEN BUT MAYBE BEHIND IT. ALL C/B'S WERE PULLED AND THE ODOR STOPPED. MAINTENANCE REMOVED AND REPLACED OVEN NR 2 SDR UALA2012091805253Switch · malfunctionedMID GALLEY HAS NO POWER TO HALF OF GALLEY. FOUND ENTIRE MID GLY POWER OFF WITH GUARDED POWER SWITCH IN NORMAL POSITION, MAT SHOWED MSG 25-31 003. AFTER CYCLING GLY SWITCH PER FIM 25-31-803 GLY PWR NORMAL. PER FIM 25-31-803 THERE WAS AN INTERMITTENT FAULT, GSDR USAA2012091000051Oven · odorFORWARD FLIGHT ATTENDANTS REPORTED MODERATE ELECTRICAL SMELL IN FORWARD GALLEY. DIVERTED BACK TO CLT AFTER REPORTS OF BREATHING ISSUES. FOUND OVEN IN FORWARD GALLEY CAUSING ODOR. REMOVED AND REPLACED THE OVEN.SDR USAA2012090700007Oven · defectiveFORWARD FLIGHT ATTENDANT REPORTED A MODERATE ELECTRICAL SMELL IN THE FORWARD GALLEY SHORTLY AFTER TAKEOFF. FLIGHT DECK CREW NOTICED A SLIGHT SMELL AFTER TAKEOFF THAT QUICKLY DISSIPATED. ALL THREE F/A'S REPORTED BREATHING DIFFICULTIES SO THE FLIGHT RETURNED TSDR UALA2012090605020Chiller · faultyCREW REPORT: AFT CHILLER IN FWD GALLEY FAULTED. INSPECTED CHILLER AND ADJACENT ARE AS ALSO E&E COMPARTMENT, NO EVIDENCE OF ELECTRICAL ODOR. INOP'D THE CHILLER, PULLED AND COLLARED CHILLER C.B'S PER MEL 2520L. WHEN REPLACING CHILLER, ROUTE THE UNSERVICABLE CSDR R61A201209040453Coffeemaker · dirtyCREW REPORTED THE AFT COFFEE POT HAD A BURNING SMELL. MAINTENANCE CLEANED AFT COFFEEMAKER PER EMB AMM 25-37-03. OPS CHECKED GOOD.SDR CALA2012082100526Chiller · inoperativeF/A CALLED SAID HEAVY HOT ELECTRIC SMELL IN REAR OF CABIN PERFORMED SMOKE/ODOR INSP IAW AMM 05-51-58-800-801C3. FOUND MID GALLEY SFT CHILLER OVERHEATING & AMP; NOT SHUTTING OFF, PLACED CHILLER ON PLACARD. CHILLER DEACTIVATED. REMOVED & AMP; REPLACED CHILLER NRSDR UALA2012082204684Oven · faultyCREW REPORTS BURNING SMELL FROM OVEN. LEFT OVEN FAN INOP. REPLACED FORWARD LEFT OVEN. OP TEST OKAY.
Back to JASC 2530