JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YENA20120816581Coffeemaker · failedFLT 171 JFK-SMF, FLIGHT CREW REPORTED ELECTRICAL SMELL IN AFT COFFEE POT AREA. REMOVED POWER AND PULLED 3 CB'S AND SMELL DISSIPATED. ACCOMPLISHED TSM 24-00-00-810-823-A, FOUND COFFEEMAKER INOP. REMOVED AND REPLACED NR 1 AFT COFFEEMAKER IAW A320MM 25-35-15. Aug 16, 2012 · N649JB · Airbus A320232SDR A6WA20120927771Slide · defectiveGALLEY ICE DRAWER HAS FALLEN OFF TRACK AND IS BLOCKING THE SERVICE DOOR. REPLACED GALLEY ICE DRAWER AND BOTH SLIDES IAW AMM, OP CHECK GOOD R/P/MEL.Aug 14, 2012 · N442AW · Cndair CL6002B19SDR YENA20120808573Coffeemaker · faultyFLT 69 SYR-JFK, CREW DECLARED EMERGENCY DUE TO SMOKE IN FWD GALLEY AND FWD LAV. THE LAV WAS HAZY. NO VISIBLE SMOKE IN GALLEY. F/A SAID SEVERAL TIMES NO NEW SMOKE WAS VISIBLY COMING OUT. PERFORMED FIM TASK 21-20-00-810-801-A. NO DEFECTS NOTED. ALL SYSTEM Aug 8, 2012 · N193JB · Emb ERJ190100IGWSDR CALA2012080800499Oven · contaminatedON TAXI OUT, F/A COMPLAINED OF MIST IN AFT CABIN, ODOR OF SULFER, AND THROAT IRRITATION. ACCOMPLISHED FIM TASK 05-51-26-0800-801C. FOUND ODOR EMINATING FROM AFT OVENS. REMOVED FOOD SCRAPS FROM SAME. NO ODOR NOTED ON ENGINE RUN. O/B CREW SUPPLIED WITH FORAug 8, 2012 · N33264 · Boeing 737824SDR UALA2012081304398Oven · smokeSMOKE FROM FWD GALLEY OVEN. POWER TURNED OFF ALONG WITH UTILITY BUSSES AND CIRCUIT BREAKERS FOR OVEN. SMOKE HAS STOPPED BUT ODOR LINGERED.Aug 7, 2012 · N518UA · Boeing 757222SDR CALA2012080600497Chiller · inoperativeSTRONG ELECTRICAL ODOR AT AFT GALLEY. GALLEY POWER SWITCH TURNED OFF AND CIRCUIT BREAKERS PULLED. ODOR DISSAPATED, FOUND AFT GALLEY CHILLER B CIRCUIT BREAKER TRIPPED. R & R CHILLER IAW MM 25-3 3-03. OPS CHECKED GOOD.Aug 6, 2012 · N77019 · Boeing 777224SDR UALA2012080604170Oven · smokeFLIGHT ATTENDANTS REPORT SMOKE FROM BUSINESS CLASS GALLEYS. SUPPLEMENTAL DATA UPDATE, PERFORMED GENERAL VISUAL INSPECTION OF BUSINESS GALLEY AS PER AMM 25-31-02. NOTHING FOUND. CABIN CREW SAW WHITE SMOKE COMING FROM INSIDE THE OVENS R31 E R32, THROUGH OVENAug 4, 2012 · N225UA · Boeing 777222SDR UALA2012080304151Fan · odorSMOKE IN FWD GALLEY OVEN, FLIGHT DIVERTED. FOUND OVEN NR 107 UPPER FAN WITH BURNT ELECTRICAL SMELL. REMOVED OVEN AND CHECKED PINS FOR ANY DAMAGE, FOUND NONE. CHECKED GALLEY CIRCUIT BREAKERS IN COCKPIT AND IN E/E COMPARTMENT, NONE WERE TRIPPED. OPERATED REMAug 3, 2012 · N518UA · Boeing 757222SDR SWAA2012080706574Coffeemaker · faultySTRONG BURNING ELECTRICAL SMELL IN AFT GALLEY AREA. ONCE GALLEY POWER WAS REMOVED SMELL DID NOT RETURN. REMOVED AND REPLACED AFT NR 1 COFFEEMAKER PER M/M.Aug 1, 2012 · N486WN · Boeing 7377H4SDR UALA2012080804273Chiller · vibrationCHILLER AFT GALLEY VIBRATS AND IS NOISY. REPLACED FAILED CHILLER PER AMM.Jul 27, 2012 · N654UA · Boeing 767322SDR UALA2012080804272Chiller · failedGALLEY CHILLER INOPERATIVE AT C62. CIRCUIT BREAKER TRIPPED. REPLACED FAILED CHILLER PER AMM.Jul 27, 2012 · N654UA · Boeing 767322SDR 29GA32721072712Coffeemaker · odorFLIGHT: 4039 TPA/EYW PILOT REPORTED PLEASE INSPECT AIRCRAFT FOR A BURNT SMELL. RETURNED TO TPA LANDED WITHOUT INCIDENT. INSPECT AIRCRAFT FOUND BURNT SMELL COMING FROM NR 2 HOT JUG. AIRCRAFT RELEASED IAW NEF G1.Jul 27, 2012 · N327AG · Saab 340BSDR YENA20120721561Coffeemaker · faultyFLT 362 PBI-LGA, A/C RETURNED TO PBI. DURING CLIMBOUT F/A ADVISED SMOKE COMING FROM VENT ABOVE AFT COFFEEMAKER POTS. REMOVED AND REPLACED AFT NR 2 COFFEEMAKER REF AMM 25-35-15. OPS CHECK OK. RE-ACTIVATED GALLEY SUPPLY SYSTEM REF AMM 24-56-00. PERFORMED OPJul 21, 2012 · N625JB · Airbus A320232SDR USAA2012071700013Chiller · overheatedFLIGHT ATTENDANT REPORTED A BURNING SMELL AND HAZE IN AFT GALLEY. CIRCUIT BREAKERS FOR AFT GALLEY WERE PULLED AND AIRCRAFT DIVERTED TO PHX. MAINTENANCE FOUND AFT GALLEY CHILLER OVERHEATED DUE TO CLOGGED DUCT. REMOVED AND REPLACED CHILLER UNIT.Jul 16, 2012 · N192UW · Airbus A321211SDR UALA2012071603840Chiller · noisyFLIGHT ATTENDANT AND PAX REPORTED NOISE COMING FROM OUTSIDE OF R1 DOOR TO SEAT 2B ON DESCENT. ODD NOISE WAS INTERMITTENT. MOST OF THE TIME CHILLER SOUNDED FINE THEN STARTED TO SOUND LIKE A HELICOPTER. REPLACED CHILLER, OP CHECKED GOOD.Jul 15, 2012 · N589UA · Boeing 757222SDR SWIA201231264Coffeemaker · defectiveSMOKE SMELL COMING FROM CUP COMPARTMENT. (FLT 6203) REPLACED COFFEEMAKER.Jul 13, 2012 · N948SW · Cndair CL6002B19SDR UALA2012071203748Chiller · leakingCREW REPORTS EXCESS CONDENSATION COMING FROM CHILLER C51. WATER CLEANED UP FROM CHILLER C51. CLEARED WATER PAN. NO MORE LEAK. CHILLER OPERATION NORMAL. NO POTABLE WATER LEAKS. ALL AREA DRY.Jul 12, 2012 · N116UA · Boeing 747422SDR SWAA2012070605560Coffeemaker · faultyDECLARED EMERGENCY --- FUMES ON AFT GALLEY DUE TO FAULTY COFFEEMAKER. REMOVED AND REPLACED COFFEEMAKER PER MM.Jul 5, 2012 · N483WN · Boeing 7377H4SDR CA120704007Coffeemaker · odor(CAN) AT TOP OF CLIMB IN-CHARGE REPORTED AN ACRID SMELL IN THE AFT GALLEY. ELECTRICAL POWER TO THE GALLEY WAS SHUTOFF AS WERE THE RECIRCULATING FANS. THE ODOR DISSIPATED AND THE FLT CONTINUED. AS THE IN-FLIGHT CREW WAS PREPARING THE CABIN FOR DESCENT THEY TUJul 2, 2012 · Boeing 76738ESDR QXEA2012063000592Coffeemaker · contaminatedAFT F/A REPORTS AN ODOR IN AFT CABIN. INSPECTED AFT CABIN. CONFIRMED ODOR, BOTH MAPCO`S ON. FOUND RUBBER BAND ON TOP OF MAPCO HANDLE. REMOVED RT MAPCO. COULD NOT DETECT ODOR. R & R RIGHT MAPCO. OPS CHECKED GOOD. COMPLIED WITH AIR CONTAMINATION CHECKLIST.Jun 30, 2012 · N447QX · Bombdr DHC8402SDR R61A201206130307Coffeemaker · failedDURING CRUISE TO DCA CREW REPORTED SMOKE SMELL IN CABIN. CREW DECLARED EMERGENCY AND DIVERTED TO CMH. AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE TROUBLESHOT PER EMB AMM AND FOUND COFFEEMAKER TO BE AT FAULT. MAINTENANCE REMOVED AND REPLACED COFFEEMAKER PJun 13, 2012 · N820MD · Emb ERJ170100SUSDR YENA20120613528Coffeemaker · defectiveFLT 401 BOS-MSY, FWD GALLEY COFEEMAKER LIGHT ELECTRICAL SMELL. TURNED OFF C/M AND SMELL DISSIPATED. REMOVED AND REPLACED OUTBOARD COFFEEMAKER IAW AMM 25-35-01. OPS CHECK GOOD.Jun 13, 2012 · N283JB · Emb ERJ190100IGWSDR USAA2012060500016Duct · misroutedON TAXI OUT, FLIGHT ATTENDANT REPORTED AFT GALLEY CARTS ALL HOT TO THE TOUCH AND AN ELECTRICAL SMELL. AIRCRAFT RETURNED TO THE GATE. MAINTENANCE FOUND CHILLER EXHAUST DUCT IMPROPERLY ROUTED - RE-ROUTED DUCT.Jun 1, 2012 · N541UW · Airbus A321231SDR USAA2012060400018Chiller · defectiveFLIGHT ATTENDANT REPORTED BURNING SMELL IN AFT GALLEY WHICH DISSIPATED AFTER CHILLER WAS TURNED OFF. MAINTENANCE REMOVED AND REPLACED AFT CHILLER IAW AIRBUS MAINTENANCE MANUAL 25-31-51.Jun 1, 2012 · N185UW · Airbus A321211SDR CA120607006Heater · burned(CAN) HAVE JUST ATTENDED THE SUBJECT ACFT AFTER THE CREW REPORTED A BURNING ODOR FROM THE GALLEY AREA. UPON INVESTIGATION A SMALL HOLE HAD BEEN BURNED IN THE CARPET ADJACENT TO THE SINK AREA. THE CARPET HAS BEEN REMOVED AND THE CAUSE OF THE ISSUE HAS BEEN IDEMay 31, 2012 · Cndair CL604SDR UALA2012052702974Coffeemaker · faultyATTENDANT REPORTS ELECTRICAL ODOR AFT GALLEY. SUPPLEMENTAL DATA UPDATE, NOTED QUICK FLASH, SMOKE, ODOR, DISSIPATED QUICKLY. FLIGHT CREW PULLED CIRCUIT BREAKERS AFT GALLEY FOR INDIVIDUAL COMPONENTS. UNABLE TO DETERMINE SOURCE. REPLACED BOTH COFFEEMAKERS, OPMay 26, 2012 · N443UA · Airbus A320232SDR DALA1234151610Oven · odorAFTER TAKEOFF, BURNING ODOR VICINITY FWD OVENS, NR 2 OVEN FAULT LIGHT ILLUMINATED OVEN STOPPED WORKING ODOR DIMINISHED PULLED NR 2 OVEN CIRCUIT BREAKER AND CONTINUED FLIGHT. OPENMay 26, 2012 · N1610D · Boeing 767332SDR USAA2012052500008Coffeemaker · defectiveFLIGHT ATTENDANT REPORTED AFT GALLEY COFFEEMAKER WAS SMOKING. PULLED CIRCUIT BREAKER AND SMOKE STOPPED. COFFEEMAKER WAS PLACED ON MEL. REMOVED AND REPLACED COFFEE MAKER.May 24, 2012 · N660AW · Airbus A320232SDR SWAA2012052904349Coffeemaker · malfunctionedON DESCENT FLT ATTENDANT REPORTED BURNING SMELL "LIKE BURNING POPCORN" AFTER SELECTING GALLEY POWER OFF- SMELL WENT AWAY-FORWARD GALLEY. REMOVED AND REPLACED COFFEEMAKER PER MM.May 24, 2012 · N274WN · Boeing 7377H4SDR P5CA2012052300026Oven · dislodgedTHE UPPER DECK GALLEY OVEN FELL OUT DURING LANDING THEN THERE WAS A BURNING ODOR FOR SEVERAL MINUTES DURING TAXI IN. REMOVED OVEN UNIT AND CHECKED AREA. FOUND ELECTRIC RECEPTACLE DIRTY. CLEANED CONNECTOR PER SWPM 20-10-04. OVEN INSTALLED AND OPS WAS NORMALMay 23, 2012 · N453PA · Boeing 74746NFSDR SIMA20120521007Coffeemaker · odorDURING MAINTENANCE INSPECTION, FOUND THE LEFT SIDE HOT JUG EMITTING A STRONG ODOR. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE LEFT HOT JUG AS REQUIRED. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WAS RETURNED TO SERVICE.May 21, 2012 · N648AE · Emb EMB145LRSDR UALA2012051802843Oven · overheatedLEFT FWD GALLEY OVEN WAS OVERHEATING-SMOKEY, TURNED OFF. REPLACED FWD GALLEY R11 OVEN.May 17, 2012 · N820UA · Airbus A319131SDR UALA2012051602771Chiller · odorHEAVY ELECTRICAL ODOR IN 1ST CLASS. REMOVED ALL GALLEY POWER. REPLACED OVERHEAD GALLEY CHILLER PER MM. OPS OK. NO ODOR OBSERVED.May 14, 2012 · N214UA · Boeing 777222SDR SWIA201230720Coffeemaker · faultyLEFT COFFEEMAKER SMELLS OF BURNT PLASTIC/RUBBER WHILE OPERATING. (FLT 5514) REPLACED LEFT COFFEEMAKER.May 13, 2012 · N982SW · Cndair CL6002B19SDR SWIA201230721Coffeemaker · faultyBURNING RUBBER SMELL WHEN USING THE RIGHT COFFEEMAKER. (FLT 5443) REPLACED RIGHT COFFEEMAKER.May 11, 2012 · N982SW · Cndair CL6002B19SDR SWAA2012050803792Coffeemaker · inoperativeAFT FLIGHT ATTENDED NOTED ELECTRICAL ODOR SHORTLY BEFORE LANDING. NR 1 AFT COFFEEMAKER APPEARED INOPERATIVE. PULLED NR 1 AFT COFFEEMAKER CIRCUIT BREAKER, ODOR WENT AWAY. REMOVED & REPLACED NR 1 AFT COFFEEMAKER PER MM.May 4, 2012 · N441WN · Boeing 7377H4SDR AALA20120430002Oven · dirtyLHR - CREW REPORTED FORWARD GALLEY OVEN 1 SMOKING. FLIGHT LANDED LHR WITHOUT INCIDENT. FOUND BURNT FOOD INSIDE OVEN CAUSING SMELL AND SMOKE. CLEANED OVEN. SYSTEM GROUND CHECK NORMAL OPERATION.Apr 30, 2012 · N766AN · Boeing 777223SDR DALA1227531704Chiller · failed1 HR AFTER TAKEOFF FLIGHT ATTENDANT REPORTED FWD GALLEY CHILLER CIRCUIT BREAKER POPPED. GALLEY POWER LIGHT WAS FLICKERING AND OVENS WERE NOT WORKING. MX HAD US PULL CIRCUIT BREAKER U33 AND TURN OFF ALL GALLEY POWER SWITCHES FOR OVENS, COFFEEMAKERS AND BUN WAApr 29, 2012 · N174DZ · Boeing 767332SDR AALA20120429002Coffeemaker · malfunctionedCREW REPORTED SMELL OF BURNING FROM COFFEE MAKER 7. CREW DEACTIVATED COFFEE MAKER BY PULLING CIRCUIT BREAKER. ODOR CLEARED. INSPECTED AREA BEHIND COFFEE MAKER. NO EVIDENCE OF BURNING OR ARCING. DEFERRED COFFEE MAKER 7 PER NEF 25-32A AUTH 4-1312NEF-C.Apr 29, 2012 · N381AN · Boeing 767323SDR SIMA20120428001Coffeemaker · not seatedON FLIGHT 4236 THE FLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR. WHEN SHE TURNED THE HOT JUG OFF THE ODOR WENT AWAY. THE AIRCRAFT WAS REMOVED FROM SERVICE. FOUND HOT JUG NOT FULLY SEATED INTO O/B POSITION. REMOVED AND REPLACED THE HOT JUG AS REQUIRED. NO Apr 28, 2012 · N932AE · Emb EMB145LRSDR UALA2012042602501Chiller · sparksGALLEY CHILLER HAS ELECTRICAL SPARKING AT GALLEY G4A. REPLACED GALLEY AIR CHILLER PER MM 25-33-98. OPS CHECKED FOR 10 MINS, NORMAL.Apr 24, 2012 · N589UA · Boeing 757222SDR UALA2012042402459Chiller · sparksGALLEY CHILLER HAS ELECTRICAL SPARKING AT GALLEY G4A. CHECKED ALL WIRING IN AND AROUND CHILLER, REMOVED CART CONTROLLERS AND CHECKED WIRING FOR ALL ARE GOOD. ALL WIRING FOR GALLEY CARTS INTACT. NO ODORS OR BURNED WIRING. REPLACED GALLEY AIR CHILLER PER MM.Apr 24, 2012 · N589UA · Boeing 757222SDR DALA1226280688Freezer · malfunctionedFLIGHT ATTENDANT REPORTED FUMES FROM FIRST CLASS GALLEY AND FOLLOWED PRECAUTIONARY PROCEDURES. FUMES DID NOT DISSIPATE. SMOKE APPEARED AROUND GALLEY FREEZER ON SHORT FINAL SO FLIGHT ATTENDANT DISCHARGED PORTABLE HALON BOTTLE IN THE AREA AS AN ADDITIONAL PRECApr 24, 2012 · N688DL · Boeing 757232SDR USAA2012042300005Coffeemaker · malfunctionedCLT - FLT 801 EN ROUTE GIG TO CLT. F/A REPORTED: ELECTICAL SMELL & SMOKE AT COFFEE 01. C/B WAS PULLED AND SMOKE AND SMELL WENT AWAY. REMOVED & REPLACED FWD COFFEEMAKER.Apr 20, 2012 · N249AU · Boeing 767201SDR SIMA20120420003Coffeemaker · defectiveON FLIGHT 3291 THE FLIGHT ATTENDANT REPORTED BURNING ODOR COMING FROM COFFEE JUG AREA. THE ODOR WENT AWAY WHEN HE TURNED OFF COFFEE JUG. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED THE COFFEE JUG IAW EMB MM 25-30-00. THE OPERATIONAL CHECK WApr 20, 2012 · N730KW · Emb EMB135LRSDR QXEA2012041900338Coffeemaker · overheatedDURING DESCENT, BOTH F/A'S REPORT AN ODOR OF "BURNING RUBBER". REPLACED MAPCOS, INSPECTED RECEPTACLES AND WIRING, NO DEFECTS NOTED. CLEANED RECEPTACLES. PERFORMED GVI OF RECIRC FAN, NO DEFECTS OR ODORS PRESENT. INSPECTED BAG COMPARTMENT LIGHTS, NO DEFECTS Apr 19, 2012 · N437QX · Bombdr DHC8402SDR USAA2012041800003Oven · odorBRU - OVEN 206 (ENVOY), LEFT SIDE SMELLS ELECTRICAL AND TOXIC ACCORDING TO F/A'S. REMOVED AND REPLACED OVEN 206 (ENVOY). OPS CHECK OK.Apr 16, 2012 · N203UW · Boeing 75723NSDR AALA20120416009Oven · odiferousDFW - CREW REPORTED STRONG ELECTRICAL SMOKE SMELL IN COCKPIT. EMERGENCY DECLARED FLIGHT RETURNED DFW LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED FORWARD OVENS THAT WERE EMITTING ODOR. SYSTEM GROUND CHECK NORMAL OPERATION.Apr 16, 2012 · N471AA · Doug DC982SDR AALA20120415004Oven · inoperativeTPA - FLIGHT ATTENDANTS REPORTED AN ELECTRICAL SMELL THROUGHOUT THE CABIN. EMERGENCY DECLARED FLIGHT RETURNED TPA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND FIRST CLASS OVEN SMOKING. REPLACED FIRST CLASS GALLEY OVEN. REPLACED BOTH PACKApr 15, 2012 · N591AA · Doug DC983SDR SWAA2012041603137Coffeemaker · defectiveF/A REPORTS BURNING SMELL AFT CABIN. TURNED GALLEY POWER OFF, ODOR WENT AWAY. FOUND NR 1, COFFEEMAKER HOT PLATE WIRES MELTED. REMOVED AND REPLACED NR 1 COFFEEMAKER PER MM.Apr 15, 2012 · N399WN · Boeing 7373H4
Back to JASC 2530