Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA110106005Coffeemaker · meltedBOTH COFFEE MAKERS, BASE WAS MELTED FROM THE HEATING ELEMENTS. BASES REPLACED.SDR UALA2010122804750Cart · failedPIG TAIL P42, INOP, HAS ELECTICAL ODOR, AND HOT TO THE TOUCH. COMPLIED WITH MEL PROC, D. CYC: TEST PASS IAW NEW GALLEY CART TESTER, SUSPECT CART WAS BAD.SDR AALA20101227DEN01Coffeemaker · shortedDEN - INFLIGHT SFO-ORD. CREW REPORTED ELECTRICAL ODOR IN CABIN. EMERGENCY DECLARED FLIGHT DIVERTED DEN LANDED WITHOUT INCIDENT. FOUND NUMBER 4 COFFEEMAKER HAD SHORTED, CREATING AN ELECTRICAL ODOR IN THE AFT GALLEY AREA. REPLACED NUMBER 4 COFFEEMAKER. SYSTSDR DALA1053429014Coffeemaker · odorAT TOP OF DESCENT, F/A SMELLED A BURNING RUBBER ODOR NEAR BACK OF THE ACFT. NO SMOKE ACCOMPANIED SMELL. CREW TURNED GALLEY POWER OFF. ODOR DISAPPEARED. MX PERFORMED OPS 5088. NO SMELL NOTED. FOUND COFFEE RESIDUE ON AFT COFFEE MAKER. CLEANED COFFEE MAKER HSDR AALA20101225JFK01Coffeemaker · smokeJFK - FLIGHT ATTENDANT REPORTED SMOKE COMING FROM FIRST CLASS GALLEY COFFEEMAKER. FLIGHT ATTENDANT USED HALON FIRE EXTINGUISHER. FLIGHT RETURNED JFK LANDED WITHOUT INCIDENT. AFTER ARRIVAL REMOVED BOTH FIRST CLASS GALLEY COFFEEMAKERS AND INSPECTED THE AREA. SDR DALA1052696302Oven · smokeDURING FLIGHT, OVEN EMITTED SMOKE AND FUMES. OVEN WAS SHUTOFF AND SMOKE DISSIPATED. CIRCUIT BREAKER WAS PULLED AND FLIGHT CONTINUED. MX FOUND MELTED PASTIC CONTAINERS IN THE OVEN AND REPLACED THE OVEN, CONTROLLER, RELAYS AND TERMINAL LUGS. OPS CHECK WAS GOSDR UALA2010122104668Actuator · overheatedGALLEY CART LIFT UPPER DECK HAS BURNING ODOR AND RT AREA WARM. UPPER ACTUATOR HOT TO THE TOUCH AND HAS BEEN DISCONNECTED.SDR USAA2010122093208Coffeemaker · odorELECTRICAL ODOR FROM COCKPIT ENTRY AREA. FOUND FWD GALLEY COFFEE MAKER CAUSING ODOR. R & R FWD GALLEY COFFEE MAKER. OPS CHECK WAS GOOD.SDR AALA20101218MIA01Drain Line · disconnectedMIA - CREW REPORTED DURING CLIMB RIGHT GENERATOR TRIPPED AND STRONG ELECTRICAL SMELL THROUGHOUT THE CABIN. EMERGENCY DECLARED FLIGHT RETURNED MIA LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND DRAIN HOSE FROM FIRST CLASS GALLEY DISCONNECTED CSDR DXTA2010121904365Microwave Oven · odorON DESCENT THE F/A WAS USING THE MICRO-WAVE WHEN SHE SMELLED SMOKE AND SAW SMOKE COMING FROM BEHIND THE MICRO-WAVE. WHEN PULLING OUT THE TRASH BIN THERE WAS ALSO A DEFINITE ODOR OF SMOKE. VERIFIED SOURCE OF SMOKE IN CABIN, ORIGINATED FROM WIRING INSIDE MICROWSDR DALA1051266316Oven · smokeDURING FLIGHT, SMOKE WAS REPORTED IN THE NR2 GALLEY AREA. UTILITY BUSES WERE SWITCHED OFF, FUEL WAS DUMPED AND THE ACFT RETURNED TO DEPARTURE. MX FOUND OVENS 2-45 & 2-46 WITH MELTED PLASTIC AND REPLACED BOTH OVENS, CONTROLLERS AND SEVERAL RELAYS. OPS CHECK WSDR CALA2010121000609Oven · malfunctionedOVEN BELOW 103 F/C GALLEY INOP. OVEN BECAME VERY HOT AND STARTED TO OMIT A BURNING ODOR THEN STOPPED WORKING CD TRIPPED FOR OVEN 103. OVEN PLACED ON PLACARD. REMOVED REPLACED OVEN AT 103 F/C GALLEY OPS CHECKED GOOD. ROTABLE PARTS CHANGE WAS INDICATED - TT SDR CALA2010120300604Oven · smokeON TAXI OUT F/A REPORTED ALARM (SMOKE) IN AFT LAV, A/C LEFT ACTIVATED AFTER F/A OPENED REAR GALLEY OVEN. F/A REPORTED SMOKE INITIALLY CAME FROM OVEN BUT DISSIPATED. LAV ALARM CONTINUED TO SOUND AT GATE. INSPECTION FOUND NO SMOKE. MX CALLED PER F/A BRIEFINGSDR DALA1032915507Coffeemaker · contaminatedEN ROUTE FLIGHT ATTENDANT REPORTED FUME/SMOKE IN AFT GALLEY. SMELLED LIKE PLASTIC. CREW SECURED POWER TO AFT GALLEY. FLIGHT ATTENDANT FOUND PLASTIC GLOVES NEAR COFFEE MAKER. FLIGHT ATTENDANT REMOVED GLOVES. OPS CHECK NORMAL. GALLEY POWER OPS NORMAL. (20SDR USAA2010111992622Oven · overheatedFLT 596 - PHX - SMOKE/ODOR - FORWARD GALLEY NR 1 OVEN SMELLS AS IF IT'S OVERHEATING. PER MAINTENANCE, OVEN PRODUCED CONSIDERABLE SMOKE. REMOVED AND REPLACED NR 1 OVEN.SDR UALA2010111504228Coffeemaker · failedC-B M41 POPPED. FLT ATTENDANT REPORTS SMOKE SPARK THEN C-B POP. CREW REPORTED THAT CB SMOKED, SPARKED THEN POPPED-NOT THE COFFEMAKER. PER INBD FLT ATTN THERE WAS A POP WHEN CB M41 TRIPPED. SHE DID NOT SEE SPARK OR ODOR SMOKE. MECH TRIED TO RESET CB M41, GOT PSDR UALA2010111504230Oven · smokeWARMING OVEN NR W13 SMOKES AND SMELLS. REPLACED WARMING OVEN R13. OPS NORMAL.SDR UALA2010111504203Oven · contaminatedFWD GALLEY OVEN INOP. CREW REPORTED SMOKE COMING FROM THE FWD OVEN. CB'S WERE PULLED AND THE SMOKE DISSIPATED. PER FLT ATTENDANT SMOKE CAME FROM INSIDE THE OVEN. CB'S WERE PULLED AND THE SMOKE DISSIPATED. PER FLT ATTENDANT SMOKE CAME FROM INSIDE THE OVEN. SDR CALA2010111500537Oven · overheatedAFT GALLEY OVEN AT STA 413 OVERHEATS SCORCHING FOOD SMOKE FROM THE SCORCHED FOOD SET OFF "LAV SMOKE" ALARMS RESULTING IN AN EICAS MSG "LAV SMOKE". AFT GALLEY OVEN DEPOSITS IN BOTTOM OF OVEN CLEANED OUT. C/B PULLED AND COLLARED. ITEM DEFERRED PER MEL.SDR DALA1031270197Unknown · odorAN ELECTRICAL SMELL IN THE MID GALLEY WHEN UTILITY BUSES WERE TURNED ON, MAINTENANCE FOUND SMELL COMING FROM MID GALLEY COFFEEMAKERS. DEACTIVATED MID GALLEY COFFEEMAKERS 1 AND 2 PER NEF 253.08. MAINTENANCE CLEANED OVERFLOW SENSOR AT COFFEEMAKERS 1 AND 2. SSDR DALA1032663312Oven · malfunctionedOVEN NR 2 IN GALLEY NR 1 HAD SMOKE AND SPARKS COMING OUT, CIRCUIT BREAKER WAS PULLED AND LANDING WAS UNEVENTFUL. OVEN REPLACED AND CHECKED OK. (2010-00859)SDR UALA2010110504117Cart · odorCART 404 HAS BURNING ODOR. UNPLUGGED. NO EVIDENCE OF BURNING MARK. . CB PULLED AND COLLARED PER MEL. FOUND CABLE AND CONTROLLER OPS CHECKED OKAY, REPLACED THE FOOD CART.SDR SWIA201025159Hot Water Pot · smokeAFT HOT JUG PRODUCING SMOKE. (FLT 6181) REPLACED HOT LIQUID CONTAINER.SDR XV6A2010110400013Water Heater · odorAFTER DEPARTURE FROM F/A REPORTED BURNING ODOR FROM AFT GALLEY.SDR UALA2010110104042Coffeemaker · odorBURNED PLASTIC ODOR EMANATING FROM COFFEE POTS IN REAR GALLEY. M41 OR M42. DEACTIVATED BOTH AFT GALLEY COFFEEMAKERS (PRECAUTIONARY). REPLACED BOTH COFFEEMAKERS M-41 & M-42. RESET C-B'S & CHECKED AFT GALLEY CONDITION. ALL CHECKS GOOD.SDR CALA2010102600500Oven · odorSTRONG BURNING RUBBER SMELL ROWS 22 THRU 28 STARTED TAXI AND SMELL BECAME STRONGER PERFORMED A VISUAL INSPECTION TO ALL AFT OVEN AT 424 AND FOUND AFT CENTER OVEN WITH A VERY STRONG ODOR AND DEBRIS. REMOVED AND INSTALLED NEW OVEN IN REF AMM 25-34-00, ALSO COMPSDR ZZDA2010528Plate · malfunctionedDURING FLT, FLT ATTENDANT TURNED ON HOT PLATE ON TOP LEFT MACHINE AND GOT SPARK AND SMOKE FROM BOTTOM MACHINE. CIRCUIT BREAKERS WERE NEVER PULLED BY MX IN MDW THIS ALLOWING F/A'S TO TURN ON COFFEE POTS IN THE FIRST PLACE. COMPLIED WITH REST OF MEL PROCEDURESSDR UALA2010102103890Oven · smokeWARMING OVEN - SMOKING. DIRTY. CLEANED OVEN R32. OK FOR SERVICE.SDR UALA2010101803845Oven · faultyOVEN R31 STARTED TO OVERHEAT DURING THE PREPARATION OF THE MEAL SERVICE, EMITTED AN ELECTRICAL ODOR FLIGHT ATTENDANT SHUT OVEN DOWN IMMEDIATELY AND PULLED THE CIRCUIT BREAKER FOR THAT OVEN. REMOVED OVEN. CHK'D EVIDENCE OF ODOR FOUND NONE. DEACTIVATED OVEN PER SDR UALA2010101803837Coffeemaker · sparksCOFFEE MAKER - SMOKING OR SPARKING M31. CLEANED ELECTRICAL CONNECTOR AND REPLACED COFFEE MAKER M31. OPERATION CHECKED OKAY. NO EVIDENCE OF BURN BEHIND COFFEE MAKERS.SDR DALA1027790626Coffeemaker · malfunctionedAT CRUISE, CREW NOTED AN ACRID SMELL IN THE FWD GALLEY AREA. FOLLOWED CHECKLIST AND SHUT OFF BOTH UTILITY BUSES AND RECIRCULATION FAN. MAINTENANCE DETERMINED THE FWD COFFEEMAKER TO BE THE SOURCE AND REPLACED SAME. NO FURTHER SMELLS. (2010-D1250) (DL7571028SDR SIMA201029104Cart · odorON FLIGHT 3222 DURING THE DESCENT THE FLIGHT ATTENDANT REPORTED FUMES OF A GASOLINE NATURE COMING FROM THE GALLEY CART IN THE FORWARD GALLEY. THE CAPTAIN DECLARED AN EMERGENCY. NO OTHER ODORS OR FUMES WERE NOTED. FIRE, CRASH AND RESCUE WAS CALLED FOR THE LASDR UALA2010101503826Oven · inoperativeOVEN R52 IN AFT GALLEY INOP. ODOR OF ELECTRIC SMOKE. INBOUND CREW REPORTED, ODOR BUT NO SMOKE. FOUND CIRCUIT BREAKER NOT TRIPPED. CLEANED SAUCE. OVEN R25 CHECKED WITH RUNNING FOR 20MIN, OPS NORMAL, NO ODOR.SDR AALA20101018TUL16Oven · malfunctionedMIA - FLIGHT ATTENDANT REPORTED HEAVY SMOKE COMING FROM THE NUMBER 1 OVEN. FLIGHT ATTENDANT PULLED THE OVEN"S CIRCUIT BREAKER AND HALON EXTINGUISHER WAS DISCHARGED INTO OVEN AND SMOKE DISSIPATED. FLIGHT LANDED MIA WITHOUT INCIDENT. REPLACED NUMBER ONE OVEN.SDR DALA1025741802Oven · fireTHIRTY MINUTES AFTER DEPARTURE, F/A REPORTED THE ODOR OF SMOKE IN THE AFT GALLEY. CREW STATED THAT AFT GALLEY NR 4 OVEN EMITTED ODOR AND FLAMES. AFTER THEY PULLED C/B THE SMOKE AND FLAME EXTINGUISHED. SOURCE WAS CONFIRMED. FLT CONTINUED REMOVED OVENS 3 AND 4 ISDR USAA20101005BA054Oven · malfunctionedEN ROUTE, AT FL400, CREW REPORTED AN ELECTRICAL, SCORCH, BARNYARD LIKE ODOR ENTERED THE COCKPIT & CABIN. FLIGHT ATTENDANT IN CENTER CABIN REPORTED BURNING EYES. CREW SWITCHED PACK TO HIGH FLOW AND SMELL RECEDED. FLIGHT CONTINUED AND LANDED WITHOUT FURTHER ISDR QXEA2010100600579Coffeemaker · odorTWO COFFEEMAKERS IN REAR ARE NOT HEATING, F/A SAY THEY SMELL LIKE ASBESTOS. REPLACED BOTH COFFEEMAKERS, ONE HAD LOW COFFEE. BOTH OP'S CK GOOD NO OTHER DEFECTS NOTED. RETURNED TO SERVICE.SDR DALA1024821506Coffeemaker · burnedCOFFEEMAKER ON RT SIDE 407 EMITS SMOKE AND ELECTRICAL ODOR. CIRCUIT BREAKER PULLED FWD TO NEF, IMX REPLACED R2 COFFEEMAKER. SYS OPS IS NORMAL.SDR SWAA105683Coffeemaker · faultyREAR COFFEEMAKERS HAD BEEN SMOKING AND FLAMES. FLIGHT ATTENDANTS SHUT THEM DOWN. REMOVED AND REPLACED AFT COFFEEMAKERS PER MM.SDR CA100920006Oven · smokeSMOKE REPORTED FROM GALLEY OVEN AFTER DEPARTURE. OVEN TURNED OFF. SMOKE DISSIPATED CLEANED AFT GALLEY OVEN. RAN FOR 10 MINUTES NO SMOKE DETECTED. OPS OK.SDR AALA20100917TUL15Oven · dirtyLHR - INFLIGHT CDG-MIA. CREW REPORTED STRONG ELECTRICAL SMELL IN COCKPIT AND FORWARD CABIN. FLIGHT DIVERTED LHR LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. INSPECTED ALL ELECTRICAL SYSTEMS COULD NOT DUPLICATE ODOR. FOUND FOOD RESIDUE IN FORWARD SDR UALA2010091603443Oven · dirtyBUSINESS GALLEY OVEN R32 NEEDS CLEANING FROM HALON FIRE EXT. REPLACED R32 OVEN AND CLEANED GALLEY AREA. NO EVIDENCE OF FIRE OUTSIDE OF OVEN R32 AND FOUND BURNED PAPER INSIDE OF OVEN R32. AFTER REPLACEMENT OF OVEN R32, OVEN R32 WORKS OK.SDR UALA2010091403421Oven · contaminatedCREW REPORTS BURNING ODOR IN CABIN. ACCOMPLISHED INSP OF MID GALLEY AREA. FOUND MELTED PLASTIC IN WARMING OVEN W41. CLEANED OVEN, OPS CHECK NORMAL.SDR UALA2010091303409Chiller · leakingAFTER TAKEOFF, THE ACFT BANKED AND THE PASSENGERS IN SEATS 23 A-B-C, 24 A-B-C AND 25 A-B-C WERE SHOWERED WITH FLUID FROM THE CEILING AND VENT AREAS. IF UNABLE TO TRACE WATER LEAK PLEASE DEFER THE UPPER DECK CHILLERS REFERENCE MEL 2520ACV. CHECKED WATER FILTERSDR UALA2010090203242Chiller · leakingWATER LEAK IN ECONOMY PLUS, MOSTLY ON LT SIDE BUT SOME ON RT. TURNED OFF C2 CHILLER ON RT SIDE. LEAK SUBSIDED. THIS IS CHRONIC. ENSURE BLOCKAGE DOES NOT EXIST AND WATER FLOWS FREELY DOWN TO DRAIN MAST. WATER LEAKS AROUND ROWS 20 THRU 25 ABC AND 21 THRU 25SDR DALA1020616304Controller · failedIN FLIGHT, NR1 UPPER DECK OVEN SMELLED OF SMOKE AND CIRCUIT BREAKER POPPED. CREW SECURED OVEN. MX REPLACED THE U/D NR1 OVEN CONTROLLER. OPS CHECK WAS GOOD.SDR UALA2010082703165Chiller · inoperativeCHILLER C01 UPPER DECK GALLEY INOPERATIVE. CYCLED CHILLER C-B, OPS CHECKED NORMAL.SDR C2XA10RI106Coffeemaker · defectiveFLIGHT 2699 - FLIGHT CREW REPORTED LT COFFEEMAKER SMOKING. EWR MX REMOVED AND REPLACED LT COFFEEMAKER AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR UALA2010082403120Oven · contaminatedSMOKE FROM OVEN. NOT INSERT. REMOVED INSERT FROM OVEN. FOUND MULTIPLE FOOD SPILLS ON INSERT WHICH WAS BURNED AND THE CAUSE OF THE SMOKE. OPS CHECKED OVEN WITH NO INSERT FOR 50 MIN. NO SMOKE EMITTING FROM OVEN. OVEN OPS CHECK OK. REMOVED INSERT FOR CLEANING OVESDR N93A08242010Oven · smokeOVEN SMOKES WHEN BEING OPERATED. MX PERFORMED OPS CHECK OF OVEN AND FOUND NO DISCREPANCIES. SUSPECT FOOD HAD BEEN SPILLED INSIDE OVEN.
Back to JASC 2530