JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR AALA20100822JFK01Oven · dirtyJFK INFLIGHT BOS-MIA - FLIGHT ATTENDANTS REPORTED SMOKE COMING FROM INSIDE FIRST CLASS GALLEY OVEN. EMERGENCY DECLARED FLIGHT DIVERTED JFK LANDED WITHOUT INCIDENT. FOUND FOOD BURNED ON HEATING ELEMENT OF OVEN CAUSING SMOKE. REPLACED OVEN. SYSTEM GROUND CHEAug 22, 2010 · N656AA · Boeing 757223SDR UALA2010082303096Oven · fireR12 FWD GALLEY OVEN IGNITED A PIECE OF PAPER CAUSING SMALL FIRE & SMOKE. HALON EXTINGUISHER USED. REMOVED AND REPLACED FORWARD GALLEY OVEN R12. OPS TEST OKAY.Aug 22, 2010 · N801UA · Airbus A319131SDR YENA20100821113Coffeemaker · failedFLT 1423 PDX-LGB, A/C EN ROUTE TO LGB EXPERIENCED ELECTRICAL/METALLIC SMELL IN FWD GALLEY. THE FLIGHT CREW PULLED THE COFFEEMAKER C/B AT NR 1 POSITION AND SMELL DISSIPATED. FOUND C/B POPPED AT THE BACK OF COFFEEMAKER. REPLACED COFFEEMAKER 105. PERFORMED TAAug 21, 2010 · N534JB · Airbus A320232SDR UALA2010082303104Relay · faultyFOUND GALLEY 4B BREAKER POPPED IN COCKPIT PRIOR TO ENG RUNS. RESET BREAKER AND IT WAS POPPED AGAIN AFTER RUNS COMPLETED. REPLACED CB C743 AND RELAY K10136. NO HELP. CB POPPING AFTER 10 SECONDS. SUSPECT M227 AFT GALLEY ELCU. REPLACED LT AFT GALLEY PWR ELEAug 20, 2010 · N596UA · Boeing 757222SDR SWIA201024754Hot Water Pot · faultyELECTRICAL SMELL FROM HOT WATER JUGS IN GALLEY. (FLT 4553) REMOVED AND REPLACED HOT JUGS.Aug 17, 2010 · N284YV · Emb EMB120ERSDR AALA20100814TUL02Oven · malfunctionedANC - CREW REPORTED SMOKE ODOR IN CABIN COMING FROM FORWARD GALLEY OVEN. EMERGENCY DECLARED RETURNED ANC LANDED WITHOUT INCIDENT. REPLACED FIRST CLASS GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.Aug 13, 2010 · N604AA · Boeing 757223SDR DALA1019386314Oven · overheatedDURING FLIGHT, OVEN 2-46 OVERHEATED RESULTING IN A BURNING PLASTIC SMELL. CIRCUIT BREAKER WAS PULLED. MX REPLACED THE OVEN, OVEN CONTROLLER, RELAY AND PLUG. OPS CHECK WAS GOOD.Aug 13, 2010 · N674US · Boeing 747451SDR USAA2010081291658Oven · defectiveFLT 9 - ORD - BURNING SMELL - NR 2 OVEN HAS AN ELECTRICAL BURNING SMELL. MAINTENANCE REMOVED AND REPLACED THE NR 2 OVEN PER AIRBUS MAINTENANCE MANUAL 25-35-19.Aug 11, 2010 · N622AW · Airbus A320231SDR N93A08082010Microwave Oven · smokeF/A WAS HEATING PLATES IN THE MICROWAVE OVEN AND SMOKE AND ELECTRICAL SMELL WAS EMITTING FROM THE OVEN. DISCONTINUED USE AND PULLED CIRCUIT BREAKER AND COLLARED. SUSPECT CAUSE WAS METAL ON PLATES.Aug 8, 2010 · N426QS · Gulstm GIVSDR YENA20100806108Coffeemaker · malfunctionedFLT 359 JFK-BUR, WHEN COFFEE POT 508 TURNED ON, ELECTRICAL SMELL NOTED. TURNED OFF SAME POT AND ELECTRICAL SMELL WENT AWAY. REPLACED C/M POSITION 508. RAN FOR 1/2 HRS NO ODORS NOTED.Aug 6, 2010 · Airbus A320232SDR USAA2010080691608Oven · dirtyFLT 310 - LAX-CLT - BURNING SMELL - NR 2 OVEN FORWARD GALLEY MADE A LOUD NOISE & VIBRATION WHEN TURNED ON ACCOMPANIED BY STRONG CHEMICAL/PLASTIC SMELL. FLIGHT ATTENDANT TURNED OFF OVEN, NOISE AND VIBRATION AND SMELL STOPPED. REMOVED FOD FROM OVEN. OPERATIONAug 5, 2010 · N602AW · Airbus A320232SDR USAA2010080691609Chiller · seizedFLT 1634- MCO-PHL - BURNING SMELL - AFT CHILLER MAKING NOISE. ALSO ELECTRICAL SMELL, PULLED CIRCUIT BREAKER. REMOVED AND REPLACED AFT AIR CHILLER AS PER AMM 25-34-51-000/400 -002. OPERATIONAL CHECK GOOD.Aug 5, 2010 · N174US · Airbus A321211SDR UALA2010080502835Chiller · leakingFWD GALLEY WATER LEAK ON ELEC BAY SHORTED TR-2. REPLACED CHILLER AND DRAIN LINE AND TR-2, OP CKD ON DOCK WU G8516H S9476L AND S9477L.Aug 4, 2010 · N806UA · Airbus A319131SDR SWIA201024671Coffeemaker · faultySMOKE IN GALLEY FROM HOT JUGS. (FLT 6275) INSPECTED BOTH GALLEY CONNECTORS AND INSTALLED SERVICEABLE HOT JUGS. OPERATIONAL CHECKS NORMAL.Jul 30, 2010 · N578SW · Emb EMB120ERSDR CALA2010080300359Oven · dirtyLAV SMOKE EICAS COMES ON FOR AFT LAVS WHEN HOT OVENS ARE OPENED. FOUND OVENS AT POSITIONS 411 AND 413 FILTHY AND UNCLEANABLE. OP'ED OVENS TO HOT AND OVENS SMOKE THE DIRT. REMOVED AND REPLACED OVENS AT 411 AND 413. OPS GOOD. ROTABLE PARTS CHANGE WAS INDICAJul 30, 2010 · N13110 · Boeing 757224SDR AALA20100724ORD02Oven · dirtyORD - CREW REPORTED SMOKE IN CABIN. EMERGENCY DECLARED, RETURNED ORD LANDED WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND BURNT SUBSTANCE ON BOTTOM OF FIRST CLASS OVEN. CLEANED OVEN. RAN BOTH ENGINES AND AUXILIARY POWER UNIT AND NO SMELL OR FUMESJul 23, 2010 · N495AA · Doug DC982SDR CALA2010072700347Oven · malfunctionedSTRONG SMELL OF ELECTRICAL SMOKE IN AFT GALLEY - OVENS POTS POWERED BUT NOT ON. SMELL DISSIPATED SHORTLY AFTER ALL WERE TURNED OFF. PULLED ALL GALLEY BREAKERS, CONTINUED SAN AFTER TALKING TO DISPATCH AND MX CONTROL EN ROUTE INSPECTED GALLEY AREA PER AMM 05-5Jul 23, 2010 · N18223 · Boeing 737824SDR N93A07232010Oven · odorABOUT 30 MINUTES INTO FLIGHT, THE F/A TURNED THE OVEN ON TO WARM SOME BREAD. WITHIN A FEW MINUTES SHE NOTICED THE AREA HAD AN ELECTRICAL BURNING ODOR AND AN ODOR OTHER THAN BURNED FOOD. SHE ALSO STATED SHE NOTICED SMOKE INSIDE THE OVEN DOOR WINDOW. THE OVEN Jul 23, 2010 · N436QS · Gulstm GIVSDR C77A292168Coffeemaker · failedDURING CRUISE, DECLARED AN EMERGENCY AND DIVERTED DUE TO A REPORT OF SMOKE IN THE AFT CABIN AREA. WHILE STILL IN FLIGHT, THE F/A DETERMINED THE SMOKE WAS COMING FROM THE AFT INBD COFFEEMAKER AND TURNED THE COFFEEMAKER TO OFF. THE SMOKE DISSIPATED. THE ACFT LAJul 20, 2010 · N610CZ · Emb ERJ170200LRSDR DXTA2010072004164Coffeemaker · odor15 MIN INTO FLIGHT CREW NOTICED BURNING ODOR COMING FROM COFFEE & WATER POTS. TURNED POWER OFF TO POTS & ODOR CEASED. OPERATED BOTH TANKS FOR 30 MINUTES WITH NO ODOR NOTED. REMOVED REFRESHMENT CENTER PANELS & INSPECTED WIRING & CONNECTIONS BEHIND BAR, NO DEFJul 19, 2010 · N317QS · Cessna 680CESDR USAA2010071991458Oven · dirtyFLT 2530 - LAS - BURNING SMELL - FLIGHT ATTENDANT REPORTED THAT BOTH OVENS IN THE FORWARD GALLEY SMOKE AND CREATE A STRONG BURNING SMELL WHEN USED. MAINTENANCE CLEANED DEBRIS FROM BEHIND FANS. FUNCTIONAL CHECK WAS GOOD.Jul 16, 2010 · N647AW · Airbus A320232SDR DALA1016226811Fire · detectedA CARDBOARD FOOD BOX IN AFT OVEN NR 5 IGNITED BRIEFLY AND WAS QUICKLY EXTINGUISHED. DOOR 4R FIRE EXTINGUISHER WAS USED OR SEAL BROKEN. MAINTENANCE INSPECTED OVEN AND NO PROBLEMS WERE FOUND. THE MISSING PIN FOR FIRE EXTINGUISHER WAS REPLACED AND SECURED PER Jul 10, 2010 · N705TW · Boeing 757231SDR CALA2010070800331Oven · dirtyOVEN NR 1 STA 204, F/A REPORTED SMELL/SMOKE FR OVEN. OVEN WAS SHUT-OFF AND C/B PULLED. F/O USED RESTROOM AND EXAMINED OVEN AND REPORTED THAT IT WAS A FOOD SMELL. AFTER OVEN WAS TURNED OFF AND SMOKE/SMELL DISSIPATED FOR REMAINDER OF FLT. THIS OCCURRED AFTERJul 8, 2010 · N26226 · Boeing 737824SDR C77A288395Coffeemaker · failedDURING CRUISE, DECLARED AN EMERGENCY & DIVERTED DUE TO A REPORT OF SMOKE IN THE AFT CABIN AREA. IN FLT, AFT F/A REALIZED THAT THEY HAD INADVERTENTLY TURNED ON THE AFT INBD COFFEEMAKER, WHICH WAS CURRENTLY ON MEL. F/A ADMITTED THAT THEY KNEW COFFEEMAKER WAS ONJul 7, 2010 · N612CZ · Emb ERJ170200LRSDR DALA1014890752Oven · odorDURING FLIGHT ACRID/BURNING ODOR IN AFT GALLEY WHEN OVENS TURNED OFF, FELT HOT AIR FROM OVENS. TURNED GALLEY POWER OFF PULLED OVEN CB IN LAST 15 MINUTES ODOR AND HEAT HAS GONE AWAY. (DL75E101666)Jun 25, 2010 · N752AT · Boeing 757212SDR CALA2010062500302Oven · overheatedFWD GALLEY OVEN NR 204 GOT VERY HOT WITH SMOKE, TURNED OFF GALLEY POWER AND PULLED CB'S. OVEN REMAINED HOT (SMOKE SUBSIDED). INSPECTED GALLEY FOR OVERHEAT DAMAGE. BOTH FORWARD GALLEY OVENS VERIFIED C/B'S PULLED AND COLLARED. OVENS DEACTIVATED. OVEN P/N 2 Jun 25, 2010 · N76288 · Boeing 737824SDR DALA1014590629Coffeemaker · smokeDURING FLIGHT, AFT GALLEY FWD COFFEEMAKER WAS SMOKING. CIRCUIT BREAKER PULLED AND ELECTRIC PLUG DISCONNECTED. MX REPLACED THE COFFEE MAKER AND OPS CHECK WAS GOOD.Jun 20, 2010 · N629DL · Boeing 757232SDR AALA20100616LHR02Coffeemaker · defectiveLHR - CREW REPORTED COFFEEMAKER MADE POPPING SOUND. HAD SPARKS AND AN ELECTRICAL SMELL. CIRCUIT BREAKER PULLED. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLACED COFFEEMAKER. SYSTEM GROUND CHECK NORMAL OPERATION.Jun 16, 2010 · N186AN · Boeing 757223SDR UALA2010061402092Strainer · cloggedBURNING SMELL IN AFT GALLEY. FOUND GALLEY DRAIN STRAINER CLOGGED. REPLACED STRAINER, CLEANED AIR FILTER AND OVENS. OPS CK OK, NO SMELL ON GROUND.Jun 13, 2010 · N825UA · Airbus A319131SDR NOCA04210Oven · malfunctionedFROM CABIN LOG OVEN NR 1 IN THE FWD GALLEY IS INOP AND SPARKING. IN SEA OPENED CI 25-56 PER MEL 25-20-1 NEF 25-30-H. THE OVEN C/B WAS PULLED AND COLLARED AND OVEN IS NOT TO BE USED. REMOVED AND REPLACED NR 1 MID GALLEY OVEN OPS CHECKS NORMAL.Jun 12, 2010 · N768NA · Boeing 76736NSDR DALA1012890867Oven · odorRTB FOR BURNING SMELL IN AFT CABIN T/S FOUND SMELL FROM CTR OVEN. PULL COLLAR C/B. FWD TO NEF PROGRAM 253.30. PLACARD INSTALLED. (DL777101468)Jun 11, 2010 · N867DA · Boeing 777232SDR UALA2010061102045Oven · dirtyON TAXI OUT REAR GALLEY HAD BURNING SMELL. FOUND OVEN DIRTY, NEEDS CLEANING. SMELLS WHEN WARM. AIR SERV TASKED WITH CLEANING OVEN. OVEN HAS BEEN CLEANED.Jun 11, 2010 · N647UA · Boeing 767322SDR DALA1015090752Oven · odorDURING FLIGHT, ELECTRICAL ODOR EMITTED FROM THE LEFT AFT OVEN. CIRCUIT BREAKER WAS PULLED. MAINTENANCE RESET THE OVEN CIRCUIT BREAKER AND AN OPERATIONAL CHECK OF THE OVEN WAS GOOD.Jun 10, 2010 · N752AT · Boeing 757212SDR YENA20100608078Coffeemaker · malfunctionedFLT 867 JFK - KIN INFLIGHT CREW SMELLED SOMETHING BURNING IN FWD GALLEY BETWEEN APPROX 10000-3000 FT. SMELL WENT AWAY ON IT'S OWN. ONE FLIGHT ATTENDANT REPORTED IT SMELLED ELECTRICAL. PERFORMED TSM 24-00-00-810-823. NO FAULTS OR DEFECTS FOUND. INSPECTED LJun 8, 2010 · N703JB · Airbus A320232SDR DALA1013210909Coffeemaker · odorDURING PHASE OF FLIGHT F/A'S NOTICED BURNED ODOR BY AFT GALLEY. CREW TURNED PACKS OFF AND ON TO DISSIPATE ODOR. ACTION DIDN'T MAKE DIFFERENCE IN ODOR ONCE ON GROUND MX INSPECTED AFT GALLEY AND AFT LAVATORIES NO TROUBLE FOUND. ON CONTROL NR C06050773, OPN 5088,Jun 5, 2010 · N909DE · Doug MD88SDR AALA20100604LHR01Chiller · faultyLHR - DURING CLIMBOUT 1ST CLASS GALLEY CHILLER BEGAN MAKING A LOUD NOISE WITH VIBRATION FOLLOWED BY A STRONG ELECTRICAL BURNING SMELL. AFTER ALL GALLEY POWER TO CHILLER WAS REMOVED SOUND STOPPED AND SMELL DISSIPATED. FLIGHT LANDED LHR WITHOUT INCIDENT. REPLJun 4, 2010 · N796AN · Boeing 777223SDR DALA1012125635Oven · odorDURING FLIGHT, CREW FOUND FWD GALLEY OVENS EMITTED AN ELECTRICAL FIRE ODOR. CREW PULLED THE OVEN CIRCUIT BREAKERS AND THE ODOR SUBSIDED. MX FOUND THE TRIPLE OVEN WITH A BURNED ODOR AND REPLACED SAME. OPS CHECK WAS GOOD.Jun 2, 2010 · N535US · Boeing 757251SDR AALA20100530SJU01Oven · fireSJU - FLIGHT ATTENDANT REPORTED THAT FIRST CLASS OVEN NUMBER 1 CAUGHT ON FIRE. CIRCUIT BREAKER TO OVEN WAS PULLED AND EXTINGUISHER WAS USED TO PUT OUT FIRE. FLIGHT LANDED SJU WITHOUT INCIDENT. REPLACED OVEN AND EXTINGUISHER. SYSTEM GROUND CHECK NORMAL OPERMay 30, 2010 · N673AN · Boeing 757223SDR USAA20100602BB034Coffeemaker · faultyLIH - ODOR OF BURNING RUBBER IN AFT SECTION OF PLANE. TURNED OFF UTILITY BUSSES AND ODOR DISSIPATED. NO SIGN OF SMOKE. REPLACED AFT NUMBER SEVEN COFFEEMAKER.May 30, 2010 · N902AW · Boeing 7572S7SDR ASAA1057870Coffeemaker · malfunctionedAT 1.5 HRS INTO FLIGHT AFT F/A REPORTED STRONG ODOR COMING FROM AFT GALLEY. A/C RT NO SMOKE OR HAZE SIMILAR TO PREVIOUS WRITE UP AS A METALLIC SMELL. ODOR REPORTED BY PASSENGER AS FAR FORWARD AS ROW 19. ODOR REMAINED STRONG FOR APPROX 40 MIN THEN STARTED TOMay 26, 2010 · N563AS · Boeing 737890SDR UALA2010052601813Element · contaminatedH21 THE COFFEE WARMER SMELLS LIKE SOMETHING IS BURNING WHEN TURNED ON. FOUND MELTED PLASTIC ON ELEMENT, CLEANED.May 26, 2010 · N105UA · Boeing 747451SDR UALA2010052501780Coffeemaker · faultySMOKE SMELL ON COFFEE MAKER AFT GALLEY LT SIDE UNIT SHUTOFF AND NO SMELL OR SMOKE. SAMC TEXT: CB FOR COFFEEMAKER WAS PULLED. CHILLER CBS WERE PULLED PRECAUTIONARY. REPLACED COFFEEMAKER POS M41 AND M42. F/A REPORTED SMOKE EMANATED FROM COFFEE MAKER AT POS M41.May 24, 2010 · N548UA · Boeing 757222SDR UALA2010052401763Controller · inoperativeAFT GALLEY POWER CORDS P43 AND N43 INOPERABLE. REPLACED NEW TECH CART CONTROLLER PER MM AT N43. OPS CHECK NORMAL.May 24, 2010 · N120UA · Boeing 747422SDR CALA2010052000219Oven · overheatedFIRST CLASS OVEN 205 OVERHEATED AND THE COILS WERE BRIGHT RED. THERE WAS AN ELECTRICAL SMELL AND THE FLIGHT ATTENDANT TURNED THE OVEN OFF AND PULLED IT'S CIRCUIT BREAKER. ACCOMPLISHED AM PROCEDURE 05-51-58. OVEN DEFERRED. REPLACED OVEN NR 205. CHECKS OK. May 20, 2010 · N17139 · Boeing 757224SDR CALA2010052000218Oven · malfunctionedAFT GALLEY OVEN 413 SMOKES EXCESSIVELY AND SETS OFF LAV SMOKE DETECTOR. PLACED AFT GALLEY OVEN POS 413 ON MEL. OK TO CONT. PULLED AND COLLARD C/B. REMOVED AND REPLACED NR 413 AFT OVEN. ALL FUNCTIONS NORMAL AT THIS TIME. PLACARD REMOVED. ROTABLE PARTS CHMay 20, 2010 · N12109 · Boeing 757224SDR CALA2010052000213Oven · activatedFIRST CLASS OVEN NR 205 SMOKE AND SMELL OF BURNING. PLACED THE ABOVE ITEM ON PLACARD NR 25-P-31F. CONTROL NUMBER 510507. C/B PULLED AND COLLARED.May 18, 2010 · N14115 · Boeing 757224SDR USAA2010051790975Coffeemaker · faultyLOGPAGE:7007564 - FLT 1597 - SYR-CLT - BURNING SMELL - FLIGHT ATTENDANT REPORTS ELECTRICAL SMOKE SMELL FORWARD GALLEY COFFEE POT, PULLED COFFEE POT AND CHILLER CIRCUIT BREAKER. SMELL WENT AWAY. REMOVED AND REPLACED COFFEEMAKER PER AMM 25-35-15-04. OPERATIONAMay 17, 2010 · N745VJ · Airbus A319112SDR UALA2010051701658Oven · contaminatedELECTRICAL BURNING SMELL IN 1ST CLASS CABIN ON FINAL APPROACH. FOUND OVEN R11 WITH BURNED FOOD. REMOVED CONTENTS AND SMELL GONE. CHECKED FIRST FANS, FLUORESCENT LIGHT BALLASTS, READING LIGHTS, AND VIDEO ENTERTAINMENT SYS. ALL CKS OK.May 16, 2010 · N211UA · Boeing 777222SDR UALA2010050501511Coffeemaker · faultyBURNING ELECT SMELL ABOVE M41 CIRCUIT BREAKERS IN THAT AREA PULLED AND SMELL CLEARED. REPLACED M41 COFFEEMAKER, OPS CK OK. M42 COFFEEMAKER WAS ALSO REPLACED AS A PRECAUTION. UNABLE TO DUPLICATE ANY BURNED ELECTRICAL SMELLS IN THIS AREA.May 5, 2010 · N105UA · Boeing 747451SDR CALA2010042900177Oven · malfunctionedINFLIGHT, NOTICED BURNT FOOD SMELL. CONTACTED FWD FLIGHT ATTENDANT, F/A STATED THERE WERE GLOWING EMBERS AND FLAMES IN OVEN 205. HALON FIRE EXTINGUISHER WAS USED AND OVEN C/B WAS PULLED. FLAMES EXTINGUISHED. COMPLETED INSPECTION OF GALLEY REF AMM 05-51-26,Apr 29, 2010 · N33294 · Boeing 737824
Back to JASC 2530