JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR UALA2010042801408Chiller · faultyCREW REPORTS ELECTRICAL ODOR IN CABIN AROUND ROWS 28-34. INVESTIGATE AND REPORT FINDINGS TO SAMC. CHECKED ALL CABIN, GALLEY AND LAV LIGHTS. CHECKED ALL GALLEY EQUIP AND FOUND AFT GALLEY CHILLER CAUSING ODOR. PULLED CHILLER CBS AND INOP PER MEL. INSTALLEDApr 27, 2010 · N564UA · Boeing 757222SDR AALA20100423CDG01Oven · overheatedCDG - FLIGHT ATTENDANT REPORTED FIRST CLASS OVEN 1 OVERHEATED WITH SELECTOR IN OFF POSITION. WHEN OVEN DOOR WAS OPENED SMOKE CAME OUT. CIRCUIT BREAKER WAS PULLED. FLIGHT LANDED CDG WITHOUT INCIDENT. OVEN 1 PLACARD. OVEN REPLACED AT DFW ON 04/23/2010. SYSApr 23, 2010 · N353AA · Boeing 767323SDR UALA2010042601360Oven · dirtyOVEN - SMOKING OR SPARKING DR-2 FWD GAL 420. CREW COMMENTS: OVENS R31 AND R32 SMOKING, STOPPED WHEN TURNED OFF. *S/D* CLEANED BURNT FOOD WRAPPING FROM VENT SCREENS, RAN FOR 10 MINUTES, NO BURNING SMELL. OVENS OP NORMAL.Apr 23, 2010 · N781UA · Boeing 777222SDR UALA2010042601359Chiller · inoperativeAFT GALLEY C/B POPPED. DISCONNECTED CONNECTOR FROM ELCU AND C/B STAYED IN. ELCU C/B PULLED AND CAPPED. CHILLER H-71 IS INOP. REPLACED ELCU M227. RESET C/B AFT GALLEY, READING LIGHTS 20-41AB, HANDSET 4L, ALL CHECKS OKAY.Apr 23, 2010 · N672UA · Boeing 767322SDR CALA2010042600160Oven · defectiveBURNING SMELL, SMOKE FROM NR 205 FWD GALLEY. PULLED CIRCUIT BREAKER. PLACARD OVEN NR 205 INOP. BREAKER PULLED AND COLLARED. NEEDS OVEN 99-2532-9-0003. NO TIME DUE TO QUICK TURN INBOARD DISCREPANCIES. EXT 084979.Apr 23, 2010 · N41140 · Boeing 757224SDR R61A20100167Panel · corrodedMTX REPORTED SHEAR PANELS IN AFT GALLEY HAD CORROSION AND RIVET HEADS WERE CORRODED AS WELL. MAINTENANCE REMOVED AND REPLACED TWO INBOARD SHEAR PANELS PER EMB 170 SRM 51-31-00 PO 190567 7075-76 .050 IAW SRM 53-30-10.Apr 20, 2010 · N131HQ · Emb ERJ170200LRSDR AALA20100419MIA01Oven · dirtyMIA INFLIGHT TPA-SJU - CREW REPORTED FIRST CLASS GALLEY OVEN HAD FOOD BURNING BETWEEN INNER AND OUTER SIDEWALL. CIRCUIT BREAKER WAS PULLED AND HALON EXSTINGUISHER WAS USED. EMERGENCY DECLARED FLIGHT DIVERTED MIA LANDED WITHOUT INCIDENT. REPLACED OVEN AND HALApr 19, 2010 · N616AA · Boeing 757223SDR AALA20100418EWR01Oven · malfunctionedEWR - FLIGHT ATTENDANT REPORTED SMOKE COMING FROM FIRST CLASS GALLEY OVEN. OVEN WAS TURNED OFF AND SMOKE DISSIPATED. FLIGHT LANDED EWR WITHOUT INCIDENT. REPLACED FIRST CLASS OVEN. SYSTEM GROUND CHECK NORMAL OPERATION.Apr 18, 2010 · N633AA · Boeing 757223SDR AALA20100416TUL06Oven · malfunctionedCLO - FLIGHT ATTENDANT REPORTED A BURNING ODOR AND SMOKE VISIBLE IN THE FORWARD GALLEY AREA NEAR THE OVENS. EMERGENCY DECLARED AND FLIGHT RETURNED CLO LANDED WITHOUT INCIDENT. REPLACED BOTH FIRST CLASS GALLEY OVENS. SYSTEM GROUND CHECK NORMAL OPERATION.Apr 16, 2010 · N931AN · Boeing 737823SDR NSVA201071Coffeemaker · contaminatedDEBRIS LODGED BEHIND COFFEEMAKERS PRODUCING "BURNING" SMELL WHEN COFFEEMAKERS IN USE. REMOVED TRASH FROM BEHIND COFFEEMAKERS.Apr 16, 2010 · N199WQ · Bombdr DHC8402SDR UALA2010041601273Oven · faulty30 MINUTES AFTER T/O ELECT ODOR IN 1ST CLS GALLEY AND ROW 15. ODOR LASTED ABOUT 3 HOURS AND THEN DISSIPATED. REPLACED 1ST CLASS GALLEY OVEN R11. OPS OK.Apr 15, 2010 · N769UA · Boeing 777222SDR AALA20100410NRT01Coffeemaker · malfunctionedNRT - FLIGHT ATTENDANT REPORTED ODOR AROUND COFFEEMAKERS 7 AND 8 AND SAW WHAT APPEARED TO BE SMALL AMOUNT OF SMOKE. CIRCUIT BREAKERS PULLED. SMELL SLOWLY DISCIPATE. TURNED OFF INFLIGHT ENTERTAINMENT AND SMELL COMPLETELY DISCIPATED. FLIGHT LANDED NRT WITHOApr 9, 2010 · N789AN · Boeing 777223SDR CALA2010041200128Oven · shortedDURING CLIMB, MID GALLEY OVEN 305 BEGAN TO SMOKE WITH BURNING ODOR. REMOVED ALL FOOD ITEMS, REMOVED ALL ELECTRICAL POWER, SMOKE AND ODOR DISSIPATED. CONTINUED FLIGHT WITH OVEN UNPOWERED AND NO ADDITIONAL ABNORMALS WITH OVEN 305 C/B PULLED AND PLACARD INOP REApr 8, 2010 · N17133 · Boeing 757224SDR SWAA102006Coffeemaker · faultyFLIGHT ATTENDANT AND PASSENGERS FWD OF ROW 8 REPORTED BURNING PLASTIC ODOR. NOTICED ODOR ABOUT THE TIME LANDING EXTENDED. FOUND FWD COFFEE MAKER FAULTY. REMOVED AND REPLACED COFFEEMAKER PER MM.Apr 7, 2010 · N277WN · Boeing 7377H4SDR DALA107343161Controller · failedON FINAL APPROACH RECEIVED CALL FROM F/A THAT HE SMELLED BURNING ELECTRICAL, GALLEY POWER WAS TURNED OFF, AND LANDING WAS UNEVENTFUL. BOTH NR 1 AND NR 2 OVEN CONTROLLERS AND THE BUN WARMER WERE REPLACED AND FUNCTIONAL TEST WAS NORMAL.Apr 6, 2010 · N361NB · Airbus A319114SDR CALA2010040600126Coffeemaker · shortedFLIGHT ATTENDANT REPORTED AFT COFFEEMAKERS PRODUCED "BURNING" SMELL DURING BREW PROCESS. C/B'S PULLED - NO SMOKE NOTED FOUND C/M 419 HAS BURNT PIN ON C/P. PULLED AND COLLARED C/B & PLACED ON MEL. RAN OTHER C/M & OPS NORMAL. CONFIRMED PINS B, D AND E SHOW SApr 6, 2010 · N73291 · Boeing 737824SDR DALA106863306Oven · smokeDURING CRUISE, OVEN NR 2 POSITION 1-6 OVERHEATED, THE FOOD BEGAN TO SMOKE AND LAVATORY SMOKE DETECTOR WENT OFF. THE OVEN CIRCUIT BREAKER WAS PULLED AND 2 HALON BOTTLES WERE DISCHARGED INTO OVEN AND THE SMOKE QUICKLY DISIPATED. FLIGHT CONTINUED TO DESTINATIONApr 1, 2010 · N806NW · Airbus A330323SDR USAA20100329SB041Coffeemaker · dirtyPHL - PILOT REPORTED THE NR 1 COFFEEMAKER IN THE AFT GALLEY WAS PRODUCING AN ELECTRICAL SMELL. AFTER PULLING THE CIRCUIT BREAKER, THE SMELL STOPPED. MAINTENANCE CLEANED THE HOT PAD. NO SMELL NOTED AT THIS TIME. OPERATIONAL CHECK GOOD.Mar 27, 2010 · N458UW · Boeing 7374B7SDR QXEA2010032500193Coffeemaker · failedELECTRICAL BURNING SMELL OCCURS WHEN THE RT COFFEE MAKER IS ON IN THE GALLEY. MX REPLACED THE COFFEE MAKER IAW AMM TASKS 25-32-06-00-801 AND 25-32-06-400-801. OPS CHECKS GOOD. ACFT RETURNED TO SERVICE.Mar 21, 2010 · N613QX · Cndair CL6002C10SDR USAA2010031990613Oven · dirtyFLT 526 - PHX - SMOKE - NR 1 OVEN CAUSED SMOKE FROM BURNT DEBRIS IN BOTTOM OF OVEN AND CAUSED FORWARD LAV SMOKE DETECTOR EMERGENCY ECAM DURING CRUISE. FOUND BURNT DEBRIS ON NR 1 OVEN INSERT. REMOVED INSERT AND RAN THROUGH HEATING CYCLE. NO SMOKE NOTED.Mar 18, 2010 · N815AW · Airbus A319132SDR UALA2010031800905Oven · dirtyF/A'S SMELLED ELECTRICAL BURNING SMELL BUT NO SMOKE IN THE OVERWING JUMPSEAT AREA. PER SAM TURNED OFF THE F/A OVERWING READING LIGHTS. NO REOCCURRENCE OF SMELL. ALL MID GALLEY FLIGHT ATTENDANT READING LIGHTS AT MID GALLEY AREA TURNED ON FOR DURATION OF GROUMar 18, 2010 · N662UA · Boeing 767322SDR AALA20100317NRT01Warmer · defectiveFIRST CLASS GALLEY WARMING OVEN NUMBER 1 HAS ELECTRICAL ODOR. WARMING OVEN NUMBER 1 DEACTIVATED BY PULLING CIRCUIT BREAKER. REPLACED BUN WARMER ON WARMING COMPARTMENT. SYSTEM GROUND CHECK NORMAL OPERATION.Mar 17, 2010 · N796AN · Boeing 777223SDR UALA2010031600880Chiller · faultyCHILLER 51 IN ECONOMY GALLEY TURNS OFF EVERY 45 MINUTES OR SO, CIRCUIT BREAKER NOT POPPING BUT F/A REPORTS A STRANGE HEAT OR BURNING SMELL FROM BEHIND THE CONTROL PANEL. REPLACED CHILLER.Mar 15, 2010 · N119UA · Boeing 747422SDR DL76P100623Control Panel · odorACRID ODOR IN COCKPIT DURING CRUISE AND IN DESCENT LASTING FOR APPROX. 10 SECONDS EACH TIME. FOUND GALLEY CONTROL PANEL AT 1R WITH ACRID ODOR. SUSPECT 5 AMP FREEZER C/B AS SOURCE. (NOT TRIPPED) REPLACED C/B AND OPERATED FOR SEVERAL HOURS WITH NO DISCREPANCIEMar 11, 2010 · N144DA · Boeing 767332SDR UALA2010030500761Oven · inoperativeGALLEY OVEN INOP AT R1 DOOR RT FWD GALLEY. OVEN R12 POPPED CB WITH ASSOCIATED ELECT WHITE FLASH AND SMOKE FROM CONTROLLER BOX. COMPLIED WITH MEL, CHECKED AREA FOR FURTHER DAMAGE: NONE SEEN. ACCOMPLISHED OPS CHECK OF OVEN. OVEN OPERATES NORMALLY WITH NO DEFEMar 2, 2010 · N464UA · Airbus A320232SDR UALA2010030100725Oven · sparksGALLEY OVEN INOP AT DR-1R RT FWD GALLEY OVEN R12 POPPED CB WITH ASSOCIATED ELECT WHITE FLASH AND SMOKE FROM CONTROLLER BOX. COMPLIED WITH MEL, CHECKED AREA FOR FURTHER DAMAGE: NONE SEEN. CREW REPORTED OVEN R11 CB PULLED AS A PRECAUTION. RE-SET CB AFTER CHECKMar 1, 2010 · N464UA · Airbus A320232SDR DALA104363311Oven · fireGALLEY NR 1 OVEN NR 3 ELECTRICAL FIRE, PULLED OVEN CIRCUIT BREAKERS AND LANDING WAS UNEVENTFUL. OVEN WAS REPLACED AND CHECKS OK.Feb 28, 2010 · N811NW · Airbus A330323SDR MASA2010022800164Heater · overheatedGALLEY HEATER OVERHEAT MSG/BURN SMELL. MX PLACED HEATER ON MEL THEN LATER ON R2 GALLEY HEATER.Feb 28, 2010 · N934FJ · Cndair CL6002D24SDR DL76L100523Drain · leakingLT/CTR RT A/P CONTROL SLOOPY. CTR A/P DICONNECTED. MAN ELEV CONTROL STIFF. TRIM NML. HYD NML. MALF OCCURRED BELOW 14K. FLEW MANUAL FROM LOC INCPT AT 5K ABOVE GND. ELEV HARD TO MOVE UP/DOWN. AT 10-20 FT FELT LIKE ELEV BROKE FREE. BOUNCED LDG HIGHLY SUSPECTEFeb 27, 2010 · N174DN · Boeing 767332SDR UALA2010022200634Oven · defective1ST CLASS OVEN 12 CYCLES HOT THEN COOL. REPLACED 1ST CLASS OVEN NR 12. OPS CHECK OKAY.Feb 19, 2010 · N197UA · Boeing 747422SDR SWAA100920Coffeemaker · faultyDIVERSION - ON CLIMBOUT FROM RSW APPROX 15,000FT, FLT ATTENDANT REPORTED SMOKE IN REAR GALLEY. SWITCHED GALLEY POWER OFF, REPORTED SMOKE STOPPED. NO ELECTRICAL SMOKE SMELL NOTED. REMOVED AND REPLACED COFFEEMAKER PER MM.Feb 19, 2010 · N235WN · Boeing 7377H4SDR AALA20100217ORD01Coffeemaker · contaminatedORD - CREW REPORTED A BURNING SMELL IN THE CABIN. IN-FLIGHT ENTERTAINMENT SYSTEM WAS DEACTIVATED AND NO CHANGE NOTED. AUXILIARY POWER UNIT WAS TURNED OFF AND NO CHANGE NOTED. EMERGENCY DECLARED, RETURNED ORD WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE.Feb 17, 2010 · N197AN · Boeing 757223SDR C2XA10CL025Coffeemaker · dirtyCLE FLT 2927 THE CREW REPORTED THE LEFT COFFEE POT WAS SMOKING WHILE BREWING. MAINTENANCE INSPECTED AND CLEANED BURNT COFFEE OFF THE LEFT COFFEE POT BURNER. OPERATIONAL CHECKS WERE GOOD.Feb 12, 2010 · N14573 · Emb EMB145LRSDR AALA20100209LHR01Oven · malfunctionedGALLEY 7 OVEN NUMBER 5 HAS ELECTRICAL ODOR WHEN IN USE. PULLED CIRCUIT BREAKER. REPLACED NUMBER 5 OVEN IN AFT GALLEY. SYSTEM GROUND CHECK NORMAL OPERATION.Feb 9, 2010 · N369AA · Boeing 767323SDR DALA102573314Oven · smokeGALLEY 1-A OVEN NR 3 HAD SMOKE DUE TO POSSIBLE SPILLAGE, CIRCUIT BREAKER PULLED AND LANDING WAS UNEVENTFUL. OVEN REPLACED AND CHECKS OK.Feb 1, 2010 · N814NW · Airbus A330323SDR AALA20100131ORD01Coffeemaker · malfunctionedORD - FLIGHT ATTENDANT REPORTED, HEARD LOUD POP THEN SMOKE COMING FROM NUMBER 1 AND 2 COFFEEMAKERS. FLIGHT ATTENDANT PULLED THE BREAKERS FOR ALL THREE COFFEEMAKERS. SMOKE DISSIPATED AND FLIGHT CONTINUED WITHOUT FURTHER INCIDENT. REPLACED COFFEEMAKERS. SYSTJan 31, 2010 · N188AN · Boeing 757223SDR UALA2010020100397Oven · contaminatedDOOR 4R ELECTRICAL BURNING ODOR ABOUT 25 HRS INTO FLIGHT SEEMED LIKE A 'WAVE' IT IS INTERMITTENT AND HAS HAPPENED TWICE NEAR JUMPSEAT AND DOOR NOT NEAR GALLEY CAN BE DETECTED NEAR THE HANDLE TO THE DOOR COULD ALSO POSSIBLY BE COMING FROM THE LAV F-A HAS NOTIFIJan 31, 2010 · N771UA · Boeing 777222SDR DALA102523312Oven · smokeOVEN NR 3 HAD SMOKE COMING OUT, CIRCUIT BREAKER WAS PULLED AND LANDING WAS UNEVENTFUL. OVEN REPLACED AND CHECKED OK.Jan 29, 2010 · N812NW · Airbus A330323SDR DL764100186Oven · odorSTRONG ODOR FROM NBR 4 OVEN IN AFT GALLEY. PULLED ALL CBS AS A PRECAUTION. SMELL DISAPPATED. RAN ALL OVENS FOR 2 HOURS. NO TROUBLE FOUND. ETOPS CATEGORY 'E': PROBLEMS WITH SYS CRITICAL TO ETOPS.Jan 25, 2010 · N829MH · Boeing 767432ERSDR AALA20100125EWR02Oven · dirtyEWR - CREW REPORTED STRONG ODOR IN CENTER COACH SECTION. FOUND PLASTIC IN FIRST CLASS INBOARD OVEN CAUSING ODOR. CLEANED FORWARD INBOARD GALLEY OVEN. OPERATED OVEN AT HIGH TEMPERATURE FOR ONE HOUR AND NO ODOR NOTED. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 24, 2010 · N982TW · Doug DC983SDR F3LA2010012800321Oven · odorTHE FLIGHT CREW REPORTED A BURNING ODOR COMING FROM THE NR 2 OVEN. THE CIRCUIT BREAKER WAS PULLED AND MX DEFERRED THE NR 2 OVEN IAW NEF 25-99-30AE.Jan 24, 2010 · N908FR · Airbus A319111SDR UALA2010012100257Oven · malfunctionedBUSS GALLEY OVEN R31 CB R31 POPPED DID NOT RESET. REPLACED R31 OVEN. OPS GOOD .Jan 21, 2010 · N778UA · Boeing 777222SDR UALA2010011300164Warmer · odorODOR IN AFT GALLEY. DEACTIVATED COFFEE WARMER PLATES FOR FURTHER TROUBLESHOOTING OF ODOR. NEEDS TROUBLESHOOTING FOR SOURCE OF ODOR. REPLACED COFFEEMAKER M40 & CLEANED COFFEE WARMER. TURNED ON & OPS CK'D COFFEEMAKERS & WARMERS, NO ODOR NOTICE. INSPECTED WIJan 12, 2010 · N574UA · Boeing 757222SDR UALA2010011100118Coffeemaker · malfunctionedSTRONG PLASTIC BURNING ODOR COMING FROM AFT GALLEY VENT ABOVE COFFEEMAKER. SMELL IS NOT DEICE. FOUND MALFUNCTION COFFEEMAKER. REPLACED BOTH AFT COFFEEMAKERS M41 AND M42.Jan 9, 2010 · N829UA · Airbus A319131SDR AALA20100108ORD01Oven · inoperativeORD - CREW REPORTED STRONG ELECTRICAL SMELL IN COCKPIT AND AFT END OF CABIN. EMERGENCY DECLARED RETURNED ORD WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED FORWARD AND AFT OVENS. SYSTEM GROUND CHECK NORMAL OPERATION.Jan 8, 2010 · N624AA · Boeing 757223SDR DL777100056Chiller · inoperativeIR - MIDGALLEY AFT CHILLER INOPERATIVE. OVERHEAT LT ON WITH ELECTRICAL ODOR. C/BS PULLED AND COLLARED.Jan 8, 2010 · N865DA · Boeing 777232SDR UALA2010011100112Oven · odorCREW REPORTED OVEN NR 010 FIRST CLASS GALLEY. ELECTRICAL ODOR. REMOVED POWER & ODOR DISSIPATED. OPERATED OVEN HALF AN HOUR, NO PARTICULAR ODOR NOTED. INSIDE IS CLEAN. REPLACED OVEN, TEST GOOD. NO ODOR.Jan 8, 2010 · N577UA · Boeing 757222SDR IXXA090079OMicrowave Oven · defectiveDURING CRUISE, WHILE BEING USED THE MICROWAVE STARTED SPARKING AND EMITTED ELECTRICAL ODOR. THE CREW SHUT MICROWAVE OFF. LANDED WITHOUT FURTHER INCIDENT. MX REMOVED MICROWAVE, PULLED AND COLLARD CIRCUIT BREAKER IAW NEF 25-20-01-01. ACFT WAS RETURNED TO SERVIDec 28, 2009 · N748AX · Boeing 767232SDR UALA2009122804015Oven · smokeELECTRICAL SMOKE SMELL IN CABIN CENTERED AROUND DOOR 2L DURING DESCENT. SUPPLEMENTAL DATA UPDATE ACP CHECK OF ALL LIGHTING SYSTEM IN ACFT ON BRIGHT AND DIM, CHECKED MONITORS AND VIDEO SYSTEM AND ALL UNDER SEAT WIRING NO DEFECTS FOUND. ACP OPS CK OF PACKS AND RDec 27, 2009 · N559UA · Boeing 757222SDR N93A122709Microwave Oven · dirtyMICROWAVE WAS SMOKING DURING FLIGHT WHEN IN USE. ITEM WAS DIFFERED UNDER MEL. SUSPECT SPILLED FOOD.Dec 27, 2009 · N495QS · Gulstm GIV
Back to JASC 2530