SDR UALA2009122804004Oven · contaminatedON DESCENT BURNING ODOR NEAR BIZ GALLEY. UTILITY BUSES TURNED OFF. ALL PAX CALL LTS ON. WARMING OVEN R11 HAS MOLTEN PLASTIC STUCK TO BOTTOM CAUSING ODOR WHEN HEATED. CLEANED OVEN. INSPECTED E&E, ALL CB'S IN ACFT, NONE POPPED-GALLEY EQPT, CHILLERS, COFFEEMASDR USAA20091223SB164Coffeemaker · leakingSAV - DURING CRUISE AT FL280, EN ROUTE FROM DCA TO FLL, THE FLIGHT ATTENDANTS REPORTED A BURNING WIRE SMELL COMING FROM THE AFT GALLEY AREA. SMELL WAS GETTING STRONGER. GALLEY POWER WAS REMOVED AND BUS TRANSFER WAS PLACED TO OFF PER QRH. FLIGHT DIVERTED TO SDR CALA2009122100746Oven · inoperativeSMELLED ELECTRICAL ODOR NEAR 2L, WAS INTERMITTENT. PULLED INTERPHONE CB. ALSO TURNED OFF UTILITY BUSSES AND TURNED OFF ALL UNNECESSARY. POWERED UP ALL SYS TO MAX, ALL LIGHTS, OVENS, CHILLERS. REF AMM 05-51-56, INSPECTED AREAS. ONLY A FAINT SMELL FROM OVENSDR NWAA094143356Oven · smokeDURING CRUISE SMOKE IN CABIN FROM OVEN NR 3 IN GALLEY NR 2, DONNED PBE, DISCHARGED FIRE EXTINGUISHER, TURNED CIRCUIT BREAKERS OFF AND LANDING WAS UNEVENTFUL. REF LOG PAGE 7111557, 7111558 AND 7111559.SDR DL777091883Oven · malfunctionedFLT CREW REPORTED 2 HALON BOTTLES USED ON FWD GALLEY OVEN AT POS NR 1 DUE TO HISSING ARCHING AND GLOW. C/B HAS ALSO BEEN PULLED TO ISLOATE OVEN. OVEN ISSUE ISLOATED AND OK NOW IAW CAPT. RPLCD OVEN IAW AMM. OPS CK GOOD MP/N 72077500. ETOPS CATEGORY 'F': ANYSDR IPXA09M57967Receptacle · looseHOT CUP DOES NOT HEAT WATER. RECEPTACLE PLUG IS LOOSE & THERE IS AN ODOR OF BURNING ELECTRICAL WIRES. REMOVED AND REPLACED HOT CUP PER MM 25-32-14. OPS CHECKS GOOD. THIS CLEARS M414154.SDR C77A210700Coffeemaker · defectiveFWD OTBD COFFEEMAKER STARTED SMOKING AFTER BREW BUTTON WAS PRESSED. AFTER TURNING OFF COFFEEMAKER SMOKE WENT AWAY. WILL BE REPLACING THE COFFEEMAKERSDR USAA2009113093245Coffeemaker · malfunctionedFLT 1548 - PHL - SMOKE - FLIGHT ATTENDANT REPORTED AFT GALLEY COFFEEMAKER POS 5-7 MADE A LOUD "POP" NOISE WITH ELECTRICAL SMOKE ODOR. PULLED CIRCUIT BREAKER - SMOKE CLEARED. MAINTENANCE REPLACED AFT GALLEY COFFEEMAKER POS 5-7 PER AIRBUS MAINTENANCE MANUAL 2SDR DL764091863Oven · dirtyOVEN SMOKING LOCATION A153 OVEN NR 5. OVEN CLEANED AND BRACING PLATE REMOVED AND ALL DEBRIS REMOVED TESTED OK NOW. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPSSDR UALA2009113003684Oven · smokeSMOKE FROM FWD OVEN. PIECE OF PAPER IN FWD OVEN CAUGHT ON FIRE. F/A DISCHARGED FIRE EXTINGUISHER IN FWD GALLEY.SDR F3LA2009112400237Coffeemaker · odorREFERENCE LOG PAGES 492755 AND 492756. FLIGHT CREW MADE AN AIR RETURN DUE TO A BURNING ODOR IN THE AFT GALLEY. MX PERFORMED TROUBLESHOOTING IAW TSM 21-00-00-810-802, TSM 24-00-00-810-823 AND SIL 21-135. MX DETERMINED THE AFT GALLEY COFFEEMAKERS WERE CAUSING TSDR CALA2009112000686Coffeemaker · defectiveCOFFEEMAKER 106 (FIRST CLASS GALLEY) POPPED C/B AND SMELLED LIKE ELECTRICAL ELEMENT BURNING. COFFEEMAKER 106 BREAKER PULLED AND COLLARED - SMOKE IN CABIN QUESTIONNAIRE COMPLETED - DETERMINED GALLEY NOT SOURCE OF FAILURE.SDR AALA20091107TUL01Drain Pan · crackedGALLEY 1 DRAIN PAN FOUND CRACKED. SUPPORT DOUBLER FOUND CORRODED OUT OF LIMITS. REMOVED CORROSION AND INSTALLED DOUBLER PER AARD 53-20-00-16 AND REPLACED G1 GALLEY DRAIN PAN PER SRM 51-30.SDR DL76G091719Oven · failedNUMBER 1 OVEN HAS STRONG ELECTRICAL SMELL WHEN USED. BREAKER PULLED AND COLLARED FWD TO NEF 253.30. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPSSDR CALA2009102300648Oven · defectiveF/A REPORTED A STRONG ELECTRICAL SMELL COMING FROM THE VENT IN THE AFT GALLEY CEILING. TROUBLESHOOTING REVEAL, NR 3 AFT OVEN FAN MOTOR BURNING. REMOVED AND REPLACED NR 3 AFT OVEN PER M/M 25-34-00, OPS CHECKS NORMAL, OK FOR SVC. ROTABLE PARTS CHANGE WAS INDISDR CALA2009102300647Oven · smokeOVEN 413 SMOKES WHEN IN USE. REMOVED AND REPLACED OVEN 413, GROUND OPS CHECK NORMAL AT THIS TIME. OVEN, LARGE, SG OFF 99-2533-9-0002 SN 0370, ON 99-2533-9-0002 SN 0165.SDR DL764091657Oven · failedAFT GALLEY OVEN C/B POPPED CB AND SMOKE. REMOVED FOOD DEBRIS FROM OVEN RESET C/B OPERATED OVEN 30 MINS OPS NORMAL ETOPS CATEGORY 'F'.SDR USAA2009102192820Chiller · malfunctionedFLT 926 - CLT-ORD - SMOKE SMELL - FORWARD GALLEY CHILLER MADE A LOUD NOISE, POPPED CIRCUIT BREAKER AND DISCHARGED A SMOKE SMELL INTO THE CABIN. REMOVED AND REPLACED FORWARD GALLEY CHILLER. OPERATIONAL CHECK WAS GOOD.SDR SIMA200929401Receptacle · inoperativeON FLIGHT 3849, DURING THE LANDING ROLL, THE FLIGHT ATTENDANT REPORTED THE SMELL OF ELECTRICAL SMOKE IN THE GALLEY. NO VISIBLE SMOKE DETECTED. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED THE NR 1 HOT JUG RECEPTACLE PLUG/AFT GALLEY ASSEMBLY IAW EBB 1SDR DXTA2009102003818Coffeemaker · odorPASSENGER NOTED ELECTRICAL BURNING ODOR COMING FROM THE FORWARD GALLEY. REMOVE GALLEY CIRCUIT BROKEN PANEL AND THREE EACH ACCESS PANEL TO GAIN ACCES TO GALLEY WIRING INSPECT ALL WIRING AND OPS CHECK GALLEY WIRING INSPECT ALL WIRING AND OPS CHECK GALLEY SYSTEMSDR MZZA2009101500106Oven · odorAN ELECTRICAL BURNING SMELL WAS DETECTED BY AFT FLIGHT ATTENDANTS IN THE AFT GALLEY. THE SMELL APPEARS TO BE FROM OVEN NR 1. INSPECTED AFT GALLEY OVEN PANEL CONTROLLERS POS NR 1, 2 AND 3, NO EVIDENCE OF BURNT WIRING OR SMELL. OPERATED OVENS FOR 15 MINUTES NSDR DL75E091625Oven · dirtyFIRST CLASS NR1 OVEN PRODUCED SMOKE IN FLIGHT. MX DEACTIVATED OVEN AND FORWARDED TO NEF ITEM.SDR N93A10072009Unknown · odorSHORTLY BEFORE LANDING THE F/A REPORTED A BURNING ODOR IN THE GALLEY. OVEN AND COFFEE POTS WERE OFF. TURNED OFF THE GALLEY MASTER POWER AND ODOR WENT AWAY. MX FOUND APU STARTER INOPERATIVE. WERE UNABLE TO DUPLICATE ODOR. APU STARTER WAS REPLACED, ELECTRICSDR UALA2009100603135Oven · malfunctionedELECTRICAL ODOR IN CABIN, FLIGHT DIVERTED. SUSPECT ODOR FROM GALLEY OVEN. OFFERED EVIDENCE OF BURNING ODOR. REPLACED BOTH MID GALLEY OVENS. OP TEST SATISFACTORY.SDR NWAA093475815Oven · malfunctionedEN ROUTE FROM MSP TO LAS FORWARD GALLEY NR 3 OVEN CIRCUIT BREAKER POPPED. CREW ATTEMPTED ONE RESET THEN DETECTED SMOKE FROM OVEN. DISCONTINUED USE AND PULLED CIRCUIT BREAKERS. THE FLIGHT CONTINUED TO LAS AND LANDED UNEVENTFULLY. REMOVED OVEN AND INSPECTED SDR NWAA093446314Oven · malfunctionedTHE OVEN AT LOCATION 1-26 BEGAN TO EMIT SMOKE DURING THE COOKING CYCLE. THE FLIGHT CONTINUED ON TO NRT AND LANDED UNEVENTFULLY. MAINTENANCE WOULD REPLACE BOTH THE AFFECTED OVEN AND OVEN CONTROLLER, THE SYSTEM OPERATED NORMALLY AFTER THE OVEN AND CONTROLLER WSDR CALA2009100500583Oven · odorLAVATORY SMOKE EICAS AND LAV SMOKE LIGHT AFT LAV SMOKE LIGHT ILLUMINATED DUE TO OVEN NR 411 ODOR. REMOVED PLA 25-P-30A C/N 485288. REMOVED AND REPLACED NR 411 OVEN PER 757 IFM. OPS CHECKED NORMAL. PERFORMED OPS CHECK OF BOTH AFT LAV SMOKE DETECTORS PER AMMSDR FDKA2009093000182Unknown · odorFRL FLT 6128 BWI-CVG. BURNING SMELL AROUND COFFEEMAKER TANK. MX INSPECTED GALLEY AREA FOR BURNING SMELL, NONE FOUND.SDR UALA2009093003079Oven · dirtyAT DEPARTURE CREW REPORTS BURNING SMELL IN 1ST CLASS. FOUND SEVERAL LIGHTS INOP IN NEED OF BALLAST P2511. FOUND FWD GALLEY WARMING OVENS ON & EXTREMELY HOT WITH FOIL BREAD BAG INSIDE. AFTER OVENS OFF FOR 1 HR SMELL DISSIPATED. ODOR WAS STRONGEST AT MED 1LSDR AALA20090930CUN01Heating Element · overheatedINFLIGHT DFW TO EZE. CREW REPORTED OVEN 9C AT AFT GALLEY WAS SMOKING. FLIGHT ATTENDANTS DISCHARGED TWO HALON EXTINGUISHERS AND OPENED THREE PROTECTIVE BREATHING EQUIPMENT (PBE). FOUND DEFECTIVE OVEN HEATER ELEMENT. REPLACED OVEN AND REPLACED EXTINGUISHERS SDR CALA2009092500562Oven · malfunctionedOVEN AT POSITION NR 109 AT FORWARD GALLEY SMOKED AND SPARKED, PULLED C/B, OVEN DEFECTIVE. OVEN DEACTIVATED AND DEFERRED PER PLA 25-P-33D C/N 484075. REMOVED AND REPLACED OVEN POSITION NR 109 AT FORWARD GALLEY, OPS CHECK GOOD PER IFM 25-35-03 PLACARD REMOVED.SDR DL764091535Chiller · unknownELEC SMELL IN AFT CABIN DURING CRUISE. SUSPECT CHILLER. TURNED GALLEY OFF FOR DURATION OF FLIGHT. RAN PACKS, OVENS, COFFEEMAKERS, CHILLERS, NO EVIDENCE OF ELECTRICAL ODOR. CLEANED DIRTY WATER INSIDE OF AFT GALLEY OVENS. AFT GALLEY CHILLER NR 1 DEFROST BULSDR DL76L091527Chiller · failedSTRONG BURNING ODOR FROM REAR GALLEY, FROM CHILLER AND CART VENTS. INSPECTED AFT GALLEY CHILLERS FOUND RT CHILLER INOP WITH STRONG BURNING ODOR. REPLACED AFT RT CHILLER PER MM. OPS CHECK OK. NO ODOR PRESENT. ALSO INSPECTED AFT EQUIPMENT AREAS NO BURNING SSDR CALA2009091700554Coffeemaker · defectiveFORWARD GALLEY - ON INITIAL TURN-ON, F/A HEARD LOUD POP, SAW SMOKE AND NOTICED A BURNING SMELL. INSPECTED FORWARD GALLEY FOR SMOKE (PER FORM 46-6020) - FOUND NR 2 COFFEEMAKER HAD A BROKEN / BURNT HEATING ELEMENT. REMOVED AND REPLACED COFFEEMAKER, BREWED A POSDR DL757091499Oven · shortedDURING DESCENT F/A REPORTED STRONG ODOR IN MID GALLEY AREA NO VISUAL ON SMOKE. CHECKLIST ACCOMPLISHED, WITH GASPER FANS AND UTILITY BUSSES OFF SMELL DISSIPATED. MTC FOUND THE AFT MID GALLEY RT OVEN C/B POPPED. RESET C/B, CONFIRMED SMELL FROM OVEN. PULLED ASDR ASAA0946624Oven · malfunctionedFLT ATTENDANTTS REPORTED AFT GALLEY OVEN 4 13 (BIG OVEN) BEGAN SMOKING APPROX 2 MINS AFTER APPLYING POWER. TURNED OVEN OFF. OVEN DOOR CONTINUED TO GET HOTTER. SMELL OF ELECTRICAL WIRES. SMOKE COMING OUT OF VENTS ABOVE OVEN. COULD NOT PULL CB'S IN AFT GALLSDR USAA2009091492508Coffeemaker · defectiveFLT 302 - PHX - BURNING SMELL - BURNING ELECTRICAL SMELL IN AFT GALLEY. MAINTENANCE FOUND NR 2 COFFEEMAKER IN AFT GALLEY HOT WITH EVERYTHING TURNED OFF. REMOVED AND REPLACED COFFEEMAKER.SDR 2009F00071Coffeemaker · shortedSMOKE IN FWD CABIN ON TAXI IN FROM FLT 1846. EMERGENCY EVACUATION WAS PERFORMED THROUGH THE L1 AND L2 DOORS WITH NO INJURIES. THE CAUSE OF THE SMOKE WAS FROM A DEFECTIVE COFFEEMAKER LOCATED IN THE FWD GALLEY. COFFEEMAKER WAS REPLACED WITH NO FURTHER ISSUES.SDR AALA20090830LHR01Coffeemaker · malfunctionedCOFFEEMAKER NUMBER 15 HAD AN ELECTRICAL ARC (FLASH) AND QUIT. CIRCUIT BREAKER PULLED. REPLACED COFFEEMAKER NUMBER 15.SDR C77A2009082901Coffeemaker · shortedSMOKE IN FWD CABIN ON TAXI IN. EMERGENCY EVACUATION WAS PERFORMED THROUGH THE L1 AND L2 DOORS WITH NO INJURIES. THE CAUSE OF THE SMOKE WAS FROM A DEFECTIVE COFFEEMAKER LOCATED IN THE FWD GALLEY. COFFEEMAKER WAS REPLACED WITH NO FURTHER ISSUES.SDR UALA2009082802698Oven · dirtyVERY STRONG SMELL IN MID GALLEY (SMELLS LIKE BURNING PLASTIC). NEEDS DEEP CLEAN OVEN W41. CLEANED MELTED PLASTIC TRAY FROM BOTTOM OF WARMING OVEN.SDR USAA2009082892279Chiller · odorFLT 2182 - DCA-LGA - BURNING SMELL - LOUD NOISE IN AFT GALLEY FOLLOWED BY BURNING RUBBER SMELL. FOUND CHILLER FAN MAKING NOISE AND ODOR. REMOVED AND REPLACED CHILLER PER 25-30-00. OPERATIONAL CHECK WAS GOOD. NO SMELL.SDR UALA2009082502655Actuator · failedCART LIFT FAILED, GIVING OFF STRONG ELECTRICAL SMELL. CART IS STUCK IN UP POSITION. REPLACED CART LIFT ACTUATOR.SDR CALA2009082500488Oven · fireAFT RIGHT GALLEY OVEN CAUGHT ON FIRE, PULLED C/B OVEN NR 1. REMOVED OVEN AND INSPECTED OVEN AND INSERT. FOUND NO DAMAGE AS A RESULT OF EXCESSIVE HEAT. SUSPECT BURNING FOOD AND PRECAUTIONARY PLACARD OVEN INOPERATIVE.SDR USAA2009081792136Coffeemaker · defectiveFLT 27 - PHX - BURNING SMELL - AFT GALLEY COFFEEMAKER NR 1 ELECTRICAL SMELL. FLIGHT ATTENDANT PULLED CIRCUIT BREAKER. MAINTENANCE REMOVED AND REPLACED NR 1 AFT COFFEEMAKER.SDR USAA2009081792143Oven · defectiveFLT 1496 - CLT - ELECTRICAL SMELL - OVEN IN FORWARD GALLEY GAVE OFF AN ELECTRICAL BURNING SMELL AFTER TAKEOFF. TURNED OVEN OFF AND ODOR DISSIPATED. MAINTENANCE REPLACED FORWARD GALLEY OVEN.SDR SWIA200922292Coffeemaker · sparksCOFFEEMAKER SPARKING. (FLT 6741) DEACTIVATED AND REPLACED COFFEEMAKER.SDR NWAA092726315Relay · defectiveEN ROUTE TO DTW OVEN 1-27 STARTED TO SPARK AND EMIT SMOKE. THE FLIGHT CONTINUED ON TO DTW AND MADE AN UNEVENTFUL LANDING. MAINTENANCE WOULD DEFER THE OVEN TO MEL AND WOULD LATER REPLACE RELAYS Y7PR003 AND Y7PR004. SYSTEM OPERATION WAS NORMAL AT THE TIME OF SDR NWAA092636310Oven · malfunctionedEN ROUTE TO PVG OVEN NUMBER ONE IN GALLEY NUMBER ONE BEGAN TO EMIT A BURNING ELECTRICAL ODOR. THE FLIGHT ATTENDANTS PULLED THE CIRCUIT BREAKER AND THE FLIGHT CONTINUED ON AND MADE AN UNEVENTFUL LANDING IN PVG. MAINTENANCE REPLACED THE OFFENDING OVEN AND OVENSDR UALA2009072902278Cable · chafedFLT ATTENDANT REPORTS CART AT P51 SHOCKED HIM. PULLED AND COLLARED BREAKER P51 IN G5 AFT GALLEY. REPLACED CABLE NEW TECH CART AT NR 51 DUE TO CABLE INSULATION CHAFED. TESTS OKAY.
Back to JASC 2530