JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR YENA20090728080Coffeemaker · shortedFLT 1761, FLL-SJU, AIR RETURN TO FLL DUE SMOKE FROM FWD GALLEY, RT COFFEE POT SHORTED. FOUND EVIDENCE OF BURNT WIRE NEXT TO WATER HEATER RT COFFEEMAKER. REMOVED AND REPLACED BOTH COFFEEMAKERS, LT REMOVED COFFEEMAKER PRECAUTIONARY PER AMM 25-37-03, OPS CHECK Jul 26, 2009 · N190JB · Emb ERJ190100IGWSDR NWAA092576315Oven · smokeEN ROUTE TO DTW OVEN NR 2, POSITION 1-27 IN THE UPPER DECK GALLEY CYCLED ON AND OFF AND BEGAN TO EMIT SMOKE. IT IS UNKNOWN WHAT IF ANY PRECAUTIONARY PROCEDURES WERE TAKEN BUT, THE FLIGHT CONTINUED ON TO DTW WHERE IT MADE AN UNEVENTFUL LANDING. MAINTENANCE WOJul 22, 2009 · N675NW · Boeing 747451SDR UALA2009072302174Oven · overheatedOVEN OVERHEAT, FLT DIVERTED. OVEN OVERHEAT LEAD CABIN CREW TO DISCHARGE HALON FIRE EXTINGUISHER INTO THE OVEN. NO FLAMES WERE EVER OBSERVED AND ANY OVERHEAT WAS CONTAINED WITHIN THE OVEN. FWD GALLEY HALON FIRE EXTINGUISHER WAS REPLACED. REPLACED FWD OVEN. Jul 22, 2009 · N410UA · Airbus A320232SDR BAAE002Coffeemaker · shortedGALLEY C BEV MAKER NR5 TEA POT RETURNED TO STOWAGE, BREW HANDLE MOVED DOWN TO POT. A FLASH OF WHITE SPARK WAS SEEN FROM BEV MAKER SWITCHED OFF. VISUAL INSPECTION, FOUND THAT THE SWITCH ACTUATOR PLATE ATTACHED TO THE BREW HANDLE HAD RUBBED A THE SWITCH CABLESJul 17, 2009SDR DL76G091205Oven · odorMID GALLEY OVEN GIVES OFF BURNING SMELL WHEN USED. PULLED BREAKER FWD TO NEF 253.30.Jul 17, 2009 · N178DZ · Boeing 767332SDR UALA2009072002137Oven · odorELEC ODOR COMING FROM EQUIP DOOR ABOVE MID GALLEY. DOOR WAS OPENED, NO ASSOCIATED SMOKE. ACCMP'D CHECK OF WIRING BEHIND GALLEY G2 OVERHEAD LIGHT. NO NOTED BURNS OR SMOKE DAMAGE. ALL GALLEY FUNCTIONS OPERATE NORMAL. ALL CIRCUIT BREAKERS STILL CLOSED.Jul 17, 2009 · N505UA · Boeing 757222SDR CALA2009072000377Coffeemaker · malfunctionedELECTRICAL SMELL FROM COFFEEMAKER NR 605/606 C/B`S PULLED. COFFEEMAKER NR 605 CHECKS OK. REMOVED AND REPLACED COFFEEMAKER NR 606 PER CMM 25-33-05. ROTABLE PARTS CHANGE WAS INDICATED - TT 1366548 S/N OFF 00998 COFFEEMAKER, S/N ON 0324.Jul 17, 2009 · N66051 · Boeing 767424ERSDR NWAA092546311Oven · smokeIN FLIGHT OVEN 2-46 OVERHEATED AND STARTED TO SMOKE, IT IS NOT KNOWN WHAT KIND OF PRECAUTIONARY PROCEDURE WAS TAKEN. THE FLIGHT CONTINUED ON TO MNL AND LANDED UNEVENTFULLY. MAINTENANCE REPLACED THE OFFENDING OVEN AND THE SYSTEM OPERATED NORMALLY AFTER REPLACEMJul 16, 2009 · N671US · Boeing 747451SDR CALA2009071500373Oven · defectiveSMOKE AND SPARK COMING FROM FWD GALLEY INBOARD OVEN NR 2. FOUND SMOKE AND SPARK CONTAINED TO INSIDE OVEN AND SUPPRESSED WHEN OVEN SHUTDOWN. REMOVED AND REPLACED OVEN PER AMM 25-34-00 TASKS 000-801C3 AND INSTALL 400-801C3. INSPECTED GALLEY OVEN RECEPTACLE AJul 15, 2009 · N26226 · Boeing 737824SDR CALA2009071700374Oven · dirtyPRIOR TO TAKING THE RUNWAY FOR DEPARTURE FLIGHT ATTENDANTS REPORTED SMOKE COMING FROM FORWARD GALLEY OVEN. USED AN EXTINGUISHER TO INSURE NO FIRE PERSISTED. FOUND BURNT CLOTH NAPKIN BEHIND OVEN NR 205 INSERT. SMOKE INSPECTION PERFORMED, REF AMM 05-51-56 ANDJul 14, 2009 · N74856 · Boeing 757324SDR DL76G091179Oven · odorBURNING PLASTIC ODOR IN THE REAR GALLEY. COMPLETED SMOKE FUMES CHECK LIST. F/A NOTICED OVEN NR 5 ON AFT GALLEY SUSPECTED OF ODORS TESTED ALL OVENS TO ON AT 350F FOR 15 MIN. ALL OVENS WORKING FINE, NO BURNING PLASTIC ODORS NOTED. ETOPS CATEGORY 'F': ANY OTHEJul 10, 2009 · N1501P · Boeing 7673P6SDR DL76L091135Chiller · odorAFTER CRUISE ALTITUDE DETECTED NON-ELECTRICAL SMOKE ODOR FROM AFT GALLEY FLOOR VENT CO-PILOT SIDE. CHECKED AFT GALLEY EQPMNT NO TROUBLE FOUND. DEACTIVATED AFT GALLEY CHILLERS DUE TO ODOR DISSIPATED AFTER CREW PULLED CIRCUIT BREAKERS. FWD TO NEF CODE 253.07. Jul 8, 2009 · N191DN · Boeing 767332SDR DL76L091105Oven · sparksNR 6 OVEN IN AFT GALLEY SPARKED AND HAD BURNING ODOR C/B PULLED ISOLATED/C REPLACED NBVR 6 OVEN CKS GD. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPSJul 3, 2009 · N193DN · Boeing 767332SDR USAA2009070691670Coffeemaker · defectiveFLT 1688 - CLT-YYZ - ELECTRICAL SMELL - AFT GALLEY COFFEEMAKER AT LOCATION 5-7, REPORTED BREWS ALL THE TIME AND ELECTRICAL SMELL. REMOVED AND REPLACED AFT GALLEY COFFEEMAKER AT LOCATION 5-7. OPERATIONAL CHECK WAS GOOD.Jul 3, 2009 · N723UW · Airbus A319112SDR USAA2009070691669Coffeemaker · defectiveFLT 1981 - DCA-GSO - FLIGHT ATTENDANT REPORTS SEEING SMOKE IN AFT GALLEY WITH STRONG ELECTRICAL ODOR. FOUND LEFT COFFEEMAKER HEATER CIRCUIT BREAKER BURNED. ISOLATED COFFEEMAKER AND PROGRAMMED FOR REPLACEMENT AT NEXT MAINTENANCE OPPORTUNITY. REMOVED AND REPLJul 2, 2009 · N723UW · Airbus A319112SDR UALA2009062901861Unknown · malfunctionedTWO F/A'S AND ONE PASSENGER REPORT WHAT FEELS LIKE AN "ELECTRICAL SHOCK" FROM CART WHILE USING IT AT ROW 28-29 LT OF ACFT. CARPET IN AREA WET WITH UNKNOWN MOISTURE. CRACKLING NOISE HEARD BY 2 F/A'S. FAN DRIED CARPET. CHECKED LAVS, GALLEYS & RAN CHILLERS. Jun 29, 2009 · N519UA · Boeing 757222SDR SIMA200918001SUPSocket · defectiveON FLIGHT 3411 CREW REPORTED A ELECTRICAL ODOR IN GALLEY COMING FROM THE COFFEE POT MOVED CONTAINER TO ALTERNATE POSITION AND ODOR WENT AWAY DEACTIVATED RT PLUG IAW MEL 2550 AND ISSUED MEL. AIRCRAFT REMOVED FROM SERVICE. REMOVED AND REPLACED RIGHT HOT CONTAIJun 27, 2009 · N691AE · Emb EMB145LRSDR SIMA200918001Coffeemaker · odorCREW REPORTED A ELECTRICAL ODOR IN GALLEY COMING FROM THE COFFEE POT MOVED CONTAINER TO ALTERNATE POSITION AND ODOR WENT AWAY DEACTIVATED RT PLUG IAW MEL 2550 AND ISSUED MEL AWAITING FOLLOW UP.Jun 27, 2009 · N691AE · Emb EMB145LRSDR NOCA03909Coffeemaker · defectiveCOFFEEMAKER IN AFT GALLEY, SPARKS COMING FROM WIRING. REPLACED COFFEEMAKER AS PER MM 25-31-99.Jun 27, 2009 · N755NA · Boeing 75728ASDR SWAA094125Coffeemaker · faultyFLIGHT ATTENDANT REPORTED SMOKE FROM AFT GALLEY COFFEEMAKERS. REMOVED AND REPLACED NR 2 AFT GALLEY COFFEEMAKER PER MM.Jun 26, 2009 · N260WN · Boeing 7377H4SDR DJFA2009021Microwave Oven · burnedDURING FLIGHT, CREW NOTED AN ODD ODOR WHEN USE OF THE MICROWAVE OVEN WAS ATTEMPTED; MICROWAVE OVEN FAILED TO OPERATE. AFTER LANDING, USE OF THE MICROWAVE WAS ATTEMPED A SECOND TIME. THIS TIME, THE UNIT PRODUCED SMOKE AND A BURNING SMELL. MX REPLACED THE MIJun 25, 2009 · N925FL · Emb EMB135BJSDR DL76G091069Oven · fireEVIDENCE OF PAPER FIRE IN MID GALLEY OVEN. ETOPS CATEGORY 'F': ANY OTHER EVENT DETRIMENTAL TO ETOPSJun 24, 2009 · N178DZ · Boeing 767332SDR RAIA200906250002Printed Ckt Board · overheatedFLT 7933 - UNSCHEDULED LANDING AT STL. CREW REPORTED BURNING PLASTIC SMELL IN CABIN BUT NO VISIBLE SMOKE. MAINTENANCE REMOVED AND REPLACED PRINTED CIRCUIT BOARD IN GALLEY CONTROL MODULE.Jun 23, 2009 · N808HK · Emb EMB145EPSDR DL76G091062Chiller · odorWALL SURROUNDING MID GALLEY VERY WARM 2 FLIGHT ATTENDANTS BRIEFLY SMELLED SOMETHING BURNING IN MID GALLEY. FWD TO NEF FRC NBR 253.07 PLCARD INSTALLED. R/R MID GALLEY CHILLER OPERATED CHILLER FOR 45 MIN. INSPECTE WALL BULKHEAD JUST AFT OF GALLEY NO OVEJun 22, 2009 · N174DZ · Boeing 767332SDR DL75E091057Coffeemaker · sparksF/A REPORTED SPARKS COMING FROM LOW WATER BUTTON FROM AFT NR 2 COFFEEMAKER 1ST CLASS GALLET/ REMOVED AND REPLACED F/C COFFEEMAKER OPS CHECKS NORMAL.Jun 21, 2009 · N709TW · Boeing 7572Q8SDR USAA2009062291534Coffeemaker · defectiveFLT 1145 - SAN - BURNING SMELL - FLIGHT ATTENDANT REPORTED AFT GALLEY COFFEEMAKERS SMELLS OF PLASTIC DURING THE BREW CYCLE. MAINTENANCE REMOVED AND REPLACED AFT GALLEY COFFEEMAKER IAW AIRBUS MAINTENANCE MANUAL 25-31-00.Jun 21, 2009 · N169UW · Airbus A321211SDR UALA2009061901745Oven · dirtyF/A'S REPORT INTERMITTENT ELECTRICAL ODOR AT FRONT OF ECON CABIN, WITH RECIRCS OFF, SMELL MOVED TO BACK OF ECONOMY. AFTER A SHORT PERIOD OF TIME ALL NORMAL, SMELL DISSIPATED. INFORMED BY FLT CREW THAT ODOR RESEMBLED BURNED FOOD AND PLASTIC WRAPPING RATHER THJun 19, 2009 · N776UA · Boeing 777222SDR NWAA092183311Controller · smokeGALLEY NR 2 OVEN PRODUCED LARGE AMOUNT OF SMOKE IN FLIGHT, PBE AND FIRE EXTINGUISHERS USED AND FLIGHT DIVERTED TO SNN AND LANDING WAS UNEVENTFUL. OVEN AND OVEN CONTROLLER WERE REPLACED AND CHECKS OK. REF LOG PAGE 6417752, 6417754 AND 6417753.Jun 12, 2009 · N811NW · Airbus A330323SDR UALA2009060801620Oven · dirtyWARMING OVEN - SMOKING, NEEDS CLEANING DR-1 LT GAL 410. CLEANED WARMING OVEN GAL 410 DR-1. CHECK OK NOW, NO SMOKING FOUND.Jun 6, 2009 · N769UA · Boeing 777222SDR UALA2009060401607Coffeemaker · odorBUSINESS GALLEY WARMER W31 & W32 HAS MELTED RUBBER AND ODORS IN CABIN. CLEANED, OPS CHECKED OK.Jun 4, 2009 · N122UA · Boeing 747422SDR DXTA2009052103660Receptacle · out of positionDURING COFFEE MAKER INSTALLATION, WHEN POWER WAS APPLIED, HEARD AN ELECTRICAL SOUND COME FROM BEHIND GALLEY AS WELL AS ELECTRICAL ODOR. DID NOT POP CB. INVESTIGATED PROBLEM, FOUND THT RECEPTACLE PLUG FOR COFFEEMAKER WAS TURNED CLOCKED 180 DEG OFF. REPLACED RMay 21, 2009 · N224QS · Amd FALCON2000SDR USAA2009051191140Oven · smokeFLT 138 - LAS - SMOKE - FORWARD GALLEY OVENS EMIT SMOKE AND A STRONG BURNING ELECTRICAL ODOR. REMOVED AND REPLACED BOTH OVENS.May 9, 2009 · N650AW · Airbus A320232SDR NWAA 091575519Oven · smokeTHE NUMBER ONE OVEN IN THE AFT GALLEY WAS EMITTING SMOKE WHEN THE CABIN CREW WAS HEATING UP FOOD FOR THEIR CREW MEALS. THE CABIN CREW IDENTIFIED THAT THE SMOKE WAS COMING FROM THE FAN/HEATING ELEMENT AREA. THE FLIGHT CONTINUED ON TO DTW AND LANDED WITHOUT INCMay 9, 2009 · N519US · Boeing 757251SDR UALA2009050401272Chiller · malfunctionedDEBRIEFED CREW, FIRST OFFICER AND FLIGHT ATTENDANT SAID THEY DETECTED WHAT SEEMED LIKE BURNING INSULATION IN THE FWD GALLEY AREA. FLIGHT ATTENDANT SAID THAT THE ODOR WAS SO STRONG THAT SHE HAD PULLED ALL OF THE C/B'S IN THE FWD GALLEY AND THE ODOR STARTED TO May 2, 2009 · N87UA · Boeing 757222SDR AALA2009050100002Oven · dirtyMIA CREW REPORTED SMOKE IN CABIN. EMERGENCY DECLARED RETURNED MIA WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND FIRST CLASS OVENS WITH SPILLED GREASE. CLEANED DEBRIS FROM BOTH OVENS. SYSTEM GROUND CHECK NORMAL OPERATION. (CLOSED)May 1, 2009 · N182AN · Boeing 757223SDR QXEA2009050400307Service Cart · malfunctionedGEG - LEFT SERVICE CART GETS VERY HOT TO THE POINT WHERE AN EXCESSIVE AMOUNT OF WATER VAPOR CONDENSES ON THE CABINET ABOVE AND DRIPS TO THE FLOOR IN THE AFT GALLEY. FOUND PROBLEM TO BE SERVICE CART, INSTALLED NEW SERVICE CART, OPS CHECKS GOOD. RETURNED TO SEApr 30, 2009 · N409QX · Bombdr DHC8402SDR IPXA09555709Module · faultyINSPECTION TYPE:N/A HOT CUP CAUSED BURNING SMELL AND SMOKE WITH HOT CUP ON. TURNED HOT CUP OFF WHICH PUT OUT SMOKE. DEFERRED MODULE ASSY AS INOP PER B757-200 NEF LIST 25-20-25-30-01. CONTROL NUMBER M399714 ASSIGNED. PLACARD INSTALLED. FOUND THE OVEN/HOT CApr 28, 2009 · N430UP · Boeing 75724APFSDR DL77L090760Chiller · smokeSMOKE ALARM CHIME ACTIVATED FOR SEVERAL MINUTES IN AFT GALLEY. NO SMOKE COULD BE OBSERVED VISUALLY OR ORALLY. AFTER TURNING THE A3 CHILLER OFF ALARM STOPPED AS WELL. OPERATED A3 CHILLER AND FAULT LIGHT NEVER CAME ON. DURING FURTHER INSPECTION FOUND WHISTLIApr 24, 2009 · N701DN · Boeing 777232LRSDR QXEA2009042800293Water Heater · unknownRNO - L HOT WATER JUG GETS HOT AND CLICKING SOUND. REMOVED AND REPLACED L JUG, JUG HEATS UP, NO SOUND NOTED. RETURNED TO SERVICE.Apr 24, 2009 · N402QX · Bombdr DHC8402SDR NWAA 091275521Oven · smokeIN CRUISE FROM PDX TO MSP, THE OVEN BEGAN TO SMOKE WHEN IT WAS TURNED ON. THE FLIGHT ATTENDANT TURNED THE OVEN OFF AND PULLED THE ASSOCIATED CIRCUIT BREAKER. THE FLIGHT CONTINUED ON AND LANDED UNEVENTFULLY IN MSP. MAINTENANCE REPLACED THE OVEN AND THE SYSTEApr 17, 2009 · N521US · Boeing 757251SDR AALA200904160000AOven · damagedMCI - INFLIGHT STL-LAX. CREW REPORTED SMOKE IN CABIN ORIGINATING FROM THE FORWARD GALLEY NUMBER 2 OVEN. EMERGENCY DECLARED, LANDED MCI WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND BURNED RESIDUE IN OVEN. REPLACED OVEN AND CLEARED CABIN OF SMOKE.Apr 16, 2009 · N694AN · Boeing 757223SDR DL76P090674Coffeemaker · odorF/A`S REPORTED AN ELECTRICAL ODOR IN AFT GALLEY. ODOR DISSIPATED WHEN CHILLER AND BUN WARMER WERE TURNED OFF. FOUND AFT GALLEY NR 4 COFFEE MAKER HOT PLATE COIL BAD, FWD TO NEF 253.08. C/B PULLED SECURED.Apr 15, 2009 · N140LL · Boeing 767332SDR CALA2009040900187Oven · dirtyAFTER TAXI IN AT IAH FLIGHT ATTENDANTS STATED, SMELLED A BURNING RUBBER ODOR IN THE AFT GALLEY, LIKE AN OVERHEATING WIRE IN A HAIR DRYER. REPLACED OVEN AND RECIRCULATION FILTER AND WATER SEPARATOR BAGS. PERFORMED SMOKE AND FUMES REMOVAL PER M/M 21-00-01, NOApr 9, 2009 · N14613 · Boeing 737524SDR UALA2009040901024Oven · dirtyBURNING SMELL IN BUSINESS GALLEY. FOUND WARMING OVEN W33 VERY DIRTY. CLEANED W33 AND OPS CHECKED OK NOW, NO BURNING SMELL AFTER CLEANING OF WARMING OVEN W33.Apr 8, 2009 · N779UA · Boeing 777222SDR DL777090633Chiller · odorCREW REPORTED SMOKY ODOR AT CTR GALLEY AREA. AFTER ISOLATING THE GALLEY THE ODOR DISSIPATED. CONTINUE ON THE ATL. FOUND M2 CHILLER FAILED. REMOVED AND REPLACED M2 CHILLER W/ MFPN267SV AND OPS CHECK PER AMM.Apr 5, 2009 · N862DA · Boeing 777232SDR UALA2009040600975Coffeemaker · contaminatedFUMES IN CABIN. FLIGHT DIVERTED. CREW CONFIRMED NAPKIN WAS THE SOURCE OF SMELL AFTER FUEL WAS DUMPED. NAPKIN WAS LOCATED ON COFFEE BURNER.Apr 5, 2009 · N780UA · Boeing 777222SDR UALA2009032600894Oven · defectiveDIVERTED TO DEN DUE TO CIRCUIT BREAKER FOR AFT GALLEY TRIPPING OFF. AFT GALLEY TRIPPING OFF. FLIGHT DIVERTED. FOUND ON INSPECTION BRACKET THAT HOLDS BUS PLUG 9025ML4 PULLED OUT FROM WALL. SUSPECT IT IS THE CAUSE OF TRIPPED BREAKER. REPAIRED BRACKET FOR OVENMar 25, 2009 · N422UA · Airbus A320232SDR CA090326001Coffeemaker · smoke(CAN) COFFEE MAKER STARTED TO SMOKE DURING CLIMB OUT, FA TURNED OFF POWER FROM THE GALLEY CB PANEL. SHE INFORMED THE FLIGHTDECK WHO ALSO TURNED OFF GALLEY POWER FROM THE FLIGHTDECK. THE SMOKE CLEARED BUT A BURNING SMELL LINGERED IN THE CABIN. THE CREW DECIDED Mar 23, 2009 · Emb ERJ170200SUSDR A6WA200940159Fan · failedGALLEY/LAV FAN CIRCUIT BREAKER POPPED, NOTICED SLIGHT ODOR PRIOR TO FINDING CB POPPED. SUSPECT GALLEY FAN. REPLACED GALLEY FAN OPS TEST GOOD REMOVE FROM MEL. (K)Mar 22, 2009 · N421ZW · Cndair CL6002B19SDR MASA2009032200104Coffeemaker · defectiveASH FLT 7110 DEN-MKE. F/A REPORTS, "SMELLS LIKE SMOKE" IN THE GALLEY. MX REMOVED AND REPLACED NR 2 COFFEE POT, OPS CHECKED GOOD.Mar 22, 2009 · N519LR · Cndair CL6002C10
Back to JASC 2530