SDR C2XA09IA084Coffeemaker · malfunctionedIAH - FLIGHT 2523 - THE CREW REPORTED A BURNING SMELL COMING FROM THE COFFEE POT WHEN TURNED ON. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT. MAINTENANCE REMOVED AND REPLACED THE NUMBER TWO COFFEEMAKER, OPERATIONALLY TESTED WITH NO DEFECTS. THE AIRCRAFT WASSDR NWAA09795816Oven · smokeENROUTE, OVEN NR 3 IN GALLEY 2B (AT DOOR 2R) BEGAN TO EMIT SMOKE. THE OVEN WAS TURNED OFF AND THE CIRCUIT BREAKER WAS PULLED. THE FLIGHT CONTINUED TO DESTINATION AND LANDED UNEVENTFULLY. MX DEFERRED THE OVEN TO MEL FOR FUTURE REPLACEMENT. (K)SDR USAA2009030590514Oven · odorFLT 367 - BOS-PHX - BURNING SMELL - FLIGHT ATTENDANT REPORTS HOT ELECTRICAL SMELL FROM NR 1 OVEN FORWARD GALLEY WHEN IN USE. REMOVED AND REPLACED OVEN INSERT AND FORWARD GALLEY OVEN NR 1.SDR UALA2009031000689Oven · odorAFT GALLEY C/B R41 OUT ODOR OF SMOKE IN AFT GALLEY. REMOVED OVEN R41, TO INSP WIRING, NO DEFECTS NOTED. RE-INSTALLED OVEN. PULLED AND CAPPED C/B.SDR UALA2009030200727Coffeemaker · defectiveAFT GALLEY C/B R41 OUT, SMELL SMOKE IN AFT GALLEY. REMOVED OVEN R41 TO INSP WIRING, NO DEFECTS NOTED. RE-INSTALLED OVEN. PULLED AND CAPPED C/B. REPLACED COFFEEMAKER.SDR UALA2009030200689Coffeemaker · defectiveAFT GALLEY C/B R41 OUT, SMELL SMOKE IN AFT GALLEY. REMOVED OVEN R41, TO INSP WIRING, NO DEFECTS NOTED. RE-INSTALLED OVEN. PULLED AND CAPPED C/B. REPLACED COFFEEMAKER.SDR NWAA09655523Controller · failedTHE CTR OVEN IN THE FIRST CLASS GALLEY OVERHEATED AND BEGAN TO EMIT SMOKE. THE OVEN WAS TURNED OFF, THE FLIGHT CONTINUED ON AND LANDED UNEVENTFULLY. MZ DEFERRED THE OVEN TO MEL AND LATER REPLACED THE OVEN AND OVEN CONTROLLER. SYS OPS WAS NORMAL AND AFTER THE SDR NWAA09693304Connector · damagedIAW SHOP REPORT, OVEN TEARDOWN FOUND SMOKE AND ELECTRICAL ARCHING DAMAGE ON AN INTERNAL CONNECTOR. (K)SDR P5CA2009022501587Chiller · defectiveGALLEY CHILLER MOTOR MAKES GRINDING SOUND AND COMPARTMENT HAS BURNED ELECTRICAL ODOR. REPLACED CHILLER.SDR SWAA091206Coffeemaker · faultyAIR TURNBACK - ELECTRICAL FUMES DETECTED IN FLIGHT, MID CABIN TO AFT GALLEY AREA, NO VISIBLE SMOKE. FUMES DISSIPATED AFTER POWER TURNED OFF. REMOVED AND REPLACED COFFEEMAKERS PER MM.SDR DJFA2009011Unknown · odorDURING FLIGHT, OVEN BEGAN TO SMOKE AND FIRE ODOR WAS DETECTED. OVEN WAS TURNED OFF AND ACFT LANDED SAFELY. CREW REPORTS THAT AT THE TIME, INSPECTED THE UNIT AND FOUND NO EVIDENCE OF OVERHEATING IN THE UNIT OR THE WIRING. UNIT OPERATED NORMALLY AT 300 AND 45SDR QXEA2009021800121Coffeemaker · odorSEA - F/A REPORTS ODOR COMING FROM COFFEE HEATER. FOUND HOT WATER JUG TO HAVE A BURNED PIN. REPLACED HOT JUG AND NO SMELL NOTED. RETURNED TO SERVICE.SDR CALA2009020600088Gasket · damagedSTRONG SMOKE SMELL AND VISIBLE SMOKE IN THE COCKPIT. SMELL WAS ALSO THROUGHOUT THE CABIN. COMPLIED WITH INITIAL INSPECTION AND OPERATIONAL CHECKS PER M/M 05-51-26-200-801C1. FOUND BAD GASKET ON THE INBOARD FORWARD OVEN IN THE FORWARD GALLEY. PRESSURIZED AISDR DL76L090126Oven · odorUNUSUAL ODOR FORWARD GALLEY. OPERATED ALL EQUIPMENT IN FWD GALLEY FND FAINT PLASTIC ODOR FROM UPPER OVEN. AS PRECAUTION FOUND BOTH OVENS TO NEF PER 253.30 C/B`S PULLED COLLARED OVEN.SDR DL76L090144Oven · odorUNUSUAL ODOR FORWARD GALLEY. OPERATED ALL EQUIPMENT IN FWD GALLEY FND FAINT PLASTIC ODOR FROM UPPER OVEN. AS PRECATUION FWD BOTH OVENS TO NEF PER 253.30 C/B`S PULLED COLLARED OVEN.SDR SIMA200902602Coffeemaker · odorON FLIGHT 3458 MAINTENANCE REPORTED A ELECTRICAL BURNING ODOR IN THE GALLEY AREA. AIRCRAFT REMOVED FOR SERVICE. REMOVED AND REPLACED COFFEEMAKER IAW ETN EM-25-010R1. NO DEFECTS OR ODORS NOTED. REMOVED AND REPLACED BALLAST NR RT8439-234 IAW AMM 33-21-04. OSDR USAA2009012090097Oven · smokeFLT 0586 - YYZ-PHX - SMOKE - FORWARD GALLEY NR 1 OVEN SMOKES OUT - SET OFF SMOKE DETECTOR. REMOVED AND REPLACED FORWARD GALLEY NR 1 OVEN. OPERATIONAL CHECK WAS GOOD.SDR DJFA2009003Oven · sparksDURING FLIGHT, WHEN PAX ATTEMPTED TO USE THE MICROWAVE OVEN, OVEN GENERATED SPARKS. AFTER LANDING CREW NOTICED A HOLE THAT APPEARS TO HAVE BEEN BURNED THROUGH ON THE TOP SIDE OF THE COOKING CAVITY. OPENSDR SWAA090267Coffeemaker · faulty30 MIN FROM LAS F/A REPORTED SMOKE FROM AFT COFFEE MAKER. SECURED GALLEY POWER AND SMOKE STOPPED, LANDED IN LAS. REMOVED AND REPLACED NR 1 AFT GALLEY COFFEE MAKER PER MM.SDR NWAA0945502Oven · smokeTHE CTR OVEN IN THE FWD GALLEY STARTED TO SMOKE, IT IS UNKNOWN IF ANY PRECAUTIONARY PROCEDURES WERE PERFORMED. THE FLIGHT LANDED UNEVENTFULLY IN MSP WHERE MAINTENANCE FOUND NO EVIDENCE OF FOOD, GREASE OR FOREIGN OBJECTS IN THE OVEN. THE FAN BEARING WAS SUSPESDR DL738081816Chiller · odorFLT ATTENDANT REPORTED SMALL AMOUNT WHITE SMOKE AND ELEC ODOR COMING FROM BETWEEN F/C CHILLER AND BUN WARMER. C/B`S PULLED AND NO MORE SMOKE. GALLEY POWER TURNED OFF. PULLED F/C CHILLER AND BUN WARMER AND INSPECTED AREA AND WIRING CKS OK. FOUND F/C CHILLERSDR UALA2008123007044Oven · contaminatedELECTRICAL ODOR IN CABIN. FLIGHT DIVERTED. DOOR AREA HEATER CB PULLED R12 ON OVERHEAD P11 PANEL TO SEE IF ODOR GOES AWAY. THERE IS NO SIGN OF ANY SMOKE. REPLACED RT AFT DOOR HEATER. WARMING OVEN DIRECTLY BELOW W51 HAD MELTED PLASTIC INSIDE CAUSING BURNED OSDR HNAA2008122200354Coffeemaker · smokeHOT ODOR COMING FROM NUMBER ONE HOT JUG AREA. PERFORMED HIDDEN DAMAGE INSPECTION ON NUMBER ONE HOT JUG SOCKET (IN ACCORDANCE WITH SPECIAL PROCEDURE 33.1) NO DAMAGE NOTED. PULLED AND COLLARED NUMBER ONE HOT JUG CIRCUIT BREAKER. ITEM ON MEL 25-7, SEE SEQUENCE SDR DL76G081723Oven · fodF/A IN FWD GALLEY REPORTED A LITTLE SMOKE/ELECTRICAL BURNING SMELL COMING FROM OVEN LOCATION 407. REMOVED PAPER LABEL FROM OVEN RACK. OPERATED OVEN WITH NO SMELL OR SMOKE.SDR C2XA08IA253Coffeemaker · dirtyIAH - FLIGHT 2924, DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL FROM BOTH COFFEEMAKERS. MX PLACED THE COFFEEMAKERS ON NEF NR GL01 D CTL NR 160100, AND THE ACFT WAS RETURNED TO SERVICE. ON 12/14/08 THE DISCREPANCY REPEATED AND MX INSPECTED THSDR C2XA08IA252Coffeemaker · dirtyIAH - FLIGHT 2924, DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL FROM BOTH COFFEEMAKERS. MX PLACED THE COFFEEMAKERS ON NEF NR GL01 D CTL NR 160100, AND THE ACFT WAS RETURNED TO SERVICE. ON 12/14/08 THE DISCREPANCY REPEATED AND MX INSPECTED THSDR DL76L081707Fan · inoperativeMID GALLEY OVEN WOULD NOT SWITCH OFF. EMITTED BURNT ELECT SMELL. SECURED OVEN BY PULLING C/B LOCATED IN MID GALLEY. FOUND MID GALLEY OVEN FAN INOP. FWD TO NEF PER 253.00.SDR CALA2008120801128Oven · malfunctionedSTRONG ELECTRICAL SMELL FROM MID GALLEY WHEN OVEN TURNED ON SMELL DISAPPEARED WHEN OVEN TURNED OFF. REMOVED AND REPLACED OVEN AND CONTROLLER, OPS CHECK OK. FILED SMOKE IN CABIN REPORT FOR MAINTENANCE WITH SUPERVISOR, OK TO CONTINUE. ROTATABLE PARTS CHANGE -SDR CA081205005Controller · burned(CAN) WHILE THE ACFT WAS APPROACHING, CABIN CREW REPORTED SMOKE COMING FROM BEHIND THE FWD GALLEY OVEN NR 2. THE PORTABLE FIRE EXTINGUISHER (HALON) WAS USED BY THE CABIN CREW. THE AIRCRAFT LANDED SAFELY. T/S REVEALED THAT THE NR 2 OVEN CONTROLLER FTA P/N 30SDR DL76L081685Fan · seizedELECTRICAL SMELL FROM NR 3 OVEN IN REAR GALLEY. NO LOG YET OVEN NR 4 - NOT 3 - HAS PROBLEM WITH FAN SEIZED. FWD TO NEF 253-30. C/B PULLED AND COLLARED. NEEDS OVEN ASSY.SDR DJF2008F00017Drain Mast · frozenFWD GALLEY ICE DRAWER DRAIN FROZEN, INSPECTED AND FOUND FWD GALLEY HEATED DRAIN MAST OVERHEATED AND WIRES BURNED OFF. THIS UNIT WAS REPLACED DUE TO AD2007-17-10 IAW SB145LEG-38-0013, 648.8 HRS PRIOR TO FAILURE. RECOMMEND THAT MFG TEST PARTS FOR POSSIBLE SHORSDR DL777081621Oven · odorGALLEY 401 OVEN 2 AFTER COOKING 8 MINS MADE HIGH PITCH BUZZ THEN QUIT W/ASSOCIATED BURNT WIRE ODOR NO FAULT LIGHT.SDR USAA2008112492119Oven · odorFLT 138 LAS-SNA - BURNING SMELL - NR 2 OVEN EMITS ACRID SMELL WHEN OPERATED. MAINTENANCE COULD NOT DETERMINE CAUSE FOR ODOR - PULLED CIRCUIT BREAKER. MAINTENANCE CLEANED NR 2 OVEN AND NO ODOR NOTED. NO SUBSEQUENT EVENTS.SDR DL76L081615Coffeemaker · odorAT CRUISE F/A NOTICED ODOR IN MID GALLEY POSSIBLY ELECTRICAL, AFTER C/B PULLED FOR COFFEEMAKER, DISAPPEAR IN A FEW MINUTES. ALL AREA INSPECTED, COFFEEMAKER LIGHT AND ALL EQUIPMENTS CHECKED WITH NO FAULTS FOUND.SDR AALA200802531AOven · smokeINFLIGHT - DURING CLIMB FLIGHT ATTENDANT REPORTED ELECTRICAL SMELL AND SMOKE FROM OVEN IN AFT GALLEY. TURNED OFF OVEN AND SMOKE STOPPED. PULLED CIRCUITS IN AFT GALLEY AND UTILITY BUSS TURNED OFF. REPLACED NUMBER ONE OVEN IN AFT GALLEY. SYSTEM GROUND CHECKESDR DL75E081587Oven · dirtyIR - FWD RT OVEN GIVING OFF EXCESSIVE SMOKE/FUMES WHEN HEATING. OVENS CLEANED THEN CKS OK.SDR C2XA08IA247Coffeemaker · faultySDR C2XA08IA235, FLIGHT 2459 CREW REPORTED THAT THE NUMBER ONE COFFEEMAKER SMOKES WHEN TURNED ON. MAINTENANCE PLACED ON NEF GL-01 CAT D CTL NR 157681, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 11/07/08 MAINTENANCE REMOVED AND REPLACED THE NUMBESDR SWIA200820317Coffeemaker · smokeFLT 4680 - COFFEEMAKER HAD BURNING SMELL, SET OFF LAVATORY SMOKE ALARM. REPLACED COFFEEMAKERS.SDR C2XA08IA235Coffeemaker · smokeIAH - FLIGHT 2459 THE CREW REPORTED THAT THE NUMBER ONE COFFEEMAKER SMOKES WHEN TURNED ON. MAINTENANCE INSPECTED THE AIRCRAFT AND PLACED THE NUMBER ONE COFFEEMAKER ON NEF GL-01 CAT D CTL 157681, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. SDR FILED SDR DL75E081478Coffeemaker · dirtyBURNING SMELL FROM MID GALLEY, F/O SIDE COFFEE POT HAD TO PULL C/B. CHECKED COFFEEMAKER LOCATED ON MID GALLEY F/O SIDE. OPS NORMAL. FOUND SMELL DUE TO DIRTY HOTPLATE. CLEANED SAME, OPS NORMAL.SDR NWAA084945804Oven · malfunctionedIN FLIGHT TO OGG 1 OF THE OVENS IN THE AFT GALLEY STARTED TO EMIT SMOKE. IT IS CURRENTLY UNKNOWN IF ANY PRECAUTIONARY PROCEDURES WERE PERFORMED BUT THE FLIGHT LANDED UNEVENTFULLY. MX DEFERRED THE SUSPECT OVEN TO MEL AND WOULD REPLACE IT ON 02 NOVEMBER. OPS SDR SWIA200820438Coffeemaker · smokeFLT 5446 - BURNING ELECTRICAL ODOR ON FLIGHT DECK. FOUND GALLEY HOT JUGS ARCING. REPLACED.SDR DL764081471Oven · malfunctionedDURING CLIMB F/A NOTICED A BLUEISH HAZE AND ODOR IN AFT CABIN. NR 3 AND 4 OVENS IN AFT GALLEY VERY HOT. COULD NOT TURN OFF NR 3 OVEN AND DISCHARGED HALON BOTTLE. REPORTED AFT CABIN LIGHTS COMING ON AND BRIGHT ON THEIR OWN LIKE A POWER SURGE. UNABLE TO CONTRSDR 2008UALA06001Oven · dirtyBURNING PLASTIC ODOR EVIDENT IN BUSINESS CLASS GALLEY PRIOR DEPT. FOUND EVIDENCE OF MELTED PLASTIC INSIDE WARMING OVEN. REMOVED AND CLEANED WARMING OVEN LINER. NOW OK. NO ODOR NOW EVIDENT.SDR 2008UALA05990Circuit Breaker · faultyPIGTAIL BURNING ON OVEN N51. POWER WAS REMOVED. PULLED AND CAPPED CIRCUIT BREAKER. RESET CONTROLLER, USING HI TECH GALLEY CART LOAD TESTER ALL VOLTAGES CHECK OKAY. ALL THREE LEVELS. CORD CHECKS OKAY.
SDR DL75E081239Oven · overheatedJFK - OVEN TEMP TOO HOT, FOOD CAUGHT FIRE. AFT GALLEY POS 405, AFT GALLEY NR 2 OVEN INOP. COLLARED C/B. FWD TO NEF PER FRC 253.30.SDR DL757081226Coffeemaker · odorELECTRICAL BURNING ODOR COMING FROM FWD GALLEY AREA (NO SMOKE). MX IN PROGRESS. FOUND WARMER HEATER FWD GALLEY AFT COFFEEMAKER BROKEN. REMOVED AND REPLACED COFFEE MAKER, CKS OK.SDR 2008UALA05868Oven · shortFIRST CLASS OVEN OVERHEATING. FLT DIVERTED. INTERNAL SHORT IN GALLEY OVEN. REPLACED BOTH FORWARD GALLEY OVENS. OPS CHECKED NORMAL.SDR 2008UALA05732Coffeemaker · defectiveSMOKE AND ELECTRICAL SMELL IN FORWARD GALLEY. DEFECT FOUND IN COFFEEMAKER. REPLACED COFFEEMAKER. NO STRUCTURAL DAMAGE TO GALLEY. SYSTEM OP CHECKS OKAY.
SDR YENA2008088Unknown · odorDURING CRUISING, F/A DETECTED AN ODOR OF SMOKE IN AFT GALLEY. TURNED AFT RACK POWER OFF AND ODOR WENT AWAY. ACCOMPLISHED TSM 23-39-00 AND NO DEFECT NOTED. ALL SYSTEM OPERATES WITH NO EVIDENCE OF SMOKE.