SDR DXTA200702343Coffeemaker · smokeBURNING SMELL AND SMOKE COMING FROM THE COFFEE POT. ISOLATED COFFEE POT AREA FROM WALL AND CONTINUED WITHOUT FURTHER INSTANCE. REMOVED AND REPLACED WIRE TERMINALS TO COFFEE POT- CHECK WIRES WITH METER WIRES CHECK GOOD AT THIS TIME- INSTALLED SAME COFFEE POT- Jul 17, 2007 · N227QS · Amd FALCON2000SDR N93A13072007Oven · defectiveMICROWAVE OVEN DEFECTIVE.Jul 13, 2007 · N462QS · Gulstm GIVSDR DLM88070903Oven · unserviceableSMOKE FUMES NOTICED IN FWD CABIN/COCKPIT. SECURED OVEN AND FUMES DISSIPATED. DIVERTED TO KRIC. REPLACED FIRST CLASS GALLEY OVEN. OPN CKS NML. REMOVED MCO AND PLCD.Jul 11, 2007 · N995DL · Doug MD88SDR WRLA2007079Oven · malfunctionedKBWI/LIMC FWD GALLEY OVENS MADE POPPING SOUND FOLLOWED BY ELECTRICAL SMELL WHILE COOKING. REMOVED POWER FROM OVENS BY PULLING C/B'S. RAN BOTH OVENS FOR ONE HOUR, BOTH OPERATED AS NORMAL IAW MM 25-31-50.Jul 9, 2007 · N801DE · Doug MD11SDR SWIA200718476Coffeemaker · overheatedF/A REPORTS COFFEE POT OVERHEATED WITH A BURNING ODOR. REPLACED COFFEE POT WITH SERVICEABLE UNIT. OPS CHECKS GOOD.Jul 6, 2007 · N308SW · Emb EMB120ERSDR DL757070844Oven · overheatedSMOKEY SMELL IN MID GALLEY. LT BREAKER POPPED ON AFT SECTION OF MID GALLEY M301. VENT ON FWD PART OF MID GALLEY WAS WARM TO TOUCH EVEN AFTER TURNING OFF BOTH UTILITY BUSES. FOUND AFT OVEN MID GALLEY INOP. FWD TO MCO 25-20-01E. REPLACED OVEN IN MID, OVENJul 3, 2007 · N658DL · Boeing 757232SDR 2007UALA02377Oven · fumesFLIGHT DIVERTED DUE TO FUMES COMING FROM A BUSINESS CLASS OVEN. [07-27-07] FOUND ODOR TO BE STRONGEST IN MID GALLEY AREA. APPEARED TO BE ACIDY SMELL. WHEN WARMING OVEN W33 WAS OPENED, ODOR BECAME MUCH STRONGER. FOUND PAPER TOWEL AND RESIDUE OF MELTED PLASTJul 2, 2007 · N209UA · Boeing 777222SDR SIMA200718601Coffeemaker · odorRUBBER BURNING ODOR COMING FROM GALLEY, HOT JUG SYSTEM TURNED OFF. FOUND BURNT WIRES IN HOT JUG SYSTEM MEL ISSUED. AIRCRAFT RETURNED TO SERVICE.Jul 1, 2007 · N845AE · Emb EMB135KLSDR NWAA072395512Coffeemaker · smokeFLIGHT ATTENDANT REPORTED SMOKE COMING FROM COFFEEMAKER 3-4 OR 3-5 IN GALLEY G4A. CIRCUIT BREAKERS WERE PULLED. MAINTENANCE REMOVED AND REPLACED COFFEE MAKER. OPERATIONAL CHECKED GOOD AND AIRCRAFT RETURNED TO SERVICE.Jun 29, 2007 · N512US · Boeing 757251SDR 2007UALA02227Unknown · odorBURNING SMELL IN CABIN ON ARRIVAL. INBOARD CABIN CREW REPORTED BURNING SMELL IN AFT SIDE CABIN AFTER LANDING. CHECKED NO CIRCUIT BREAKERS POPPED IN AFT GALLEY. ALSO CHECKED AFT CABIN AREA WITH CEILING PANEL REMOVED, CONDITION NORMAL. CABIN AND LAV LIGHTINGJun 25, 2007 · N217UA · Boeing 777222SDR NWAA072223358Coffeemaker · smokeSMOKE REPORTED IN THE GALLEY 1B FROM RIGHT COFFEEMAKER. DE-POWERED COFFEE MAKER VIA PUSH BUTTON CIRCUIT BREAKER AND SMOKE DISSIPATED, LANDING WAS UNEVENTFUL. COFFEE MAKER REMOVED AND REPLACED AND AIRCRAFT RETURNED TO SERVICE.Jun 24, 2007 · N858NW · Airbus A330*SDR SWAA073152Coffeemaker · faultyDIVERSION, CREW REPORTED STRONG ELECTRICAL ODOR. TURNING OFF GALLEY POWER ODOR DISSIPATED. REMOVED AND REPLACED AFT COFFEEMAKER PER MM.Jun 23, 2007 · N280WN · Boeing 7377H4SDR 2007UALA02044Unknown · odorCREW REPORTS ELECTRICAL BURNING ODOR EMANATING FROM AFT GALLEY AREA. [07-20-07] SUSPECT GALLEY HI-TECH FOODCART TO BE ODOR SOURCE PULLED AFT GALLEY LEFT CIRCUIT BREAKER U7 AND AFT GALLEY RIGHT CB U34 ON PANEL P11 TO ISOLATE POWER. RESET CBS U7 AND U34 0NJun 18, 2007 · N662UA · Boeing 767322SDR SWAA072981Coffeemaker · faultyDIVERSION, AT ALTITUDE F/A REPORTED ELECTRICAL ODOR IN REAR GALLEY, TURNED POWER OFF ODOR WENT AWAY. REMOVED AND REPLACED AFT COFFEEMAKER PER MM.Jun 11, 2007 · N767SW · Boeing 7377H4SDR WRLA2007077Fan · noisyFLIGHT 8400 FORWARD CHILLER FAN NOISY - POSSIBLE SOURCE OF ELECTRICAL BURNING ODOR . NR 2 RADAR UNIT (FWD E/E) VERY HOT, POSSIBLE SOURCE OF ELECTRICAL BURNING ODOR. CHECKED CHILLER FOR CHAFED WIRES OR DAMAGE, NONE FOUND. NO ELECTRICAL BURNING ODOR, BUT CHILJun 11, 2007 · N801DE · Doug MD11SDR DL76L070702Oven · contaminatedF/A REPORTED UNUSUAL ODOR IN AFT GALLEY AREA LEAD F/A AND RELIEF PILOT BELIVED RELATED TO HEATED DEBRIS CONTENTS OF OVEN OPERATION. SMELL DISAPPEARED WHEN OVEN AND CHILLERS BREAKERS ISOLATED. ALL AFT GALLEY ELECTRICAL COMPONENTS THROUGHLY INSPECTED NIL DEFECJun 8, 2007 · N185DN · Boeing 767332SDR NWAA072076311Controller · odorAFTER TAKEOFF, THE FLIGHT ATTENDANTS CALLED ABOUT A BURNING ODOR FROM GALLEY NR 2. CIRCUIT BREAKERS FOR OVENS 2-45, AND 2-46 WERE PULLED, AND ODOR WAS ELIMINATED. AFTER COOKING BREAKFAST, GALLEY 2A LOST ALL POWER. AS A PRECAUTION THE RED MASTER GALLEY SWITCMay 31, 2007 · N671US · Boeing 747451SDR C2XA07CL051Coffeemaker · faultyCLE FLIGHT 2519 - THE CREW REPORTED A ELECTRICAL BURNING SMELL WHEN THE COFFEE POTS WERE TURNED ON. MAINTENANCE INSPECTED AND REPLACED THE NR 2 COFFEE POT. OPERATIONAL CHECKS WERE GOOD.May 31, 2007 · N13997 · Emb EMB145LRSDR MWEA070131Oven · smokeFLIGHT ATTENDANT NOTED AN OVEN SMOKING EXCESSIVELY. CLEANED OVEN.May 30, 2007 · N914ME · Boeing 717200SDR MWEA070130Oven · smokeCENTER OVEN IN GALLEY SMOKES. CLEANED CENTER OVEN.May 30, 2007 · N909ME · Boeing 717200SDR DLM88070632Oven · contaminatedPNS-ATL FLT 467 SHORTLY AFTER T/O, A HOT OVEN/BURNING SMELL FLT 1238 BY CP AND CABIN CREW. IT DISSIPATED W/IN FEW MINUTES. FLT 1238 ATL-SRQ HAPPEN 2ND TIME ODOR WAS STRONGER AND LASTED LONGER. SUSPECTED POSSIBLE BIRD INGESTION. FLT 930 SRQ-ATL, STRONG ELECMay 30, 2007 · N946DL · Doug MD88SDR C2XA07RI035Coffeemaker · odorFLT 2465 - EWR - CREW REPORTED BURNING ODOR FROM COFFEEMAKER WHEN POWER DOWN. EWR MX PERFORMED VISUAL INSPECTION OF BOTH COFFEEMAKERS AND NO FAULTS WERE FOUND. ACFT WAS APPROVED TO RETURN TO SERVICE. COFFEEMAKER NR 1 P/N 500-0640-01 S/N 03-1-32803 TT:9809, May 29, 2007 · N13997 · Emb EMB145LRSDR MWEA070123Oven · smokeOVEN NR 2 STARTED TO SMOKE. CLEANED BURNED FOOD DEBRIS FROM BACK OF OVEN & HEATING ELEMENT.May 28, 2007 · N928ME · Boeing 717200SDR MWEA070122Oven · smokeFLIGHT ATTENDANT REPORTED THAT INTENSE SMOKE COMING FROM CENTER OVEN, WHEN TURNED ON. CLEANED FOOD FROM CENTER OVEN HEATING ELEMENTS.May 28, 2007 · N916ME · Boeing 717200SDR CA070528010Unknown · malfunctioned(CAN) A FLIGHT ATTENDANT RECEIVED AN ELECTRIC SHOCK FROM THE WATER DISPENSER IN THE REAR GALLEY. COFFEE MAKERS REMOVED, GALLEY WIRING INSPECTED AND CONTINUITY CHECK CARRIED OUT (L-4355954). MORE IT TROUBLESHOOTING STEPS HAVE BEEN PROVIDED BUT NOT COMPLETED YMay 26, 2007 · Boeing 767333SDR NOCA13107Oven · sparksON TOUCHDOWN, FWD GALLEY CENTER OVEN SPARKED. NO SMOKE NOTED, NO SMELL NOTED. PULLED & SECURED C/B FOR FWD CENTER GALLEY OVEN NR 105 OPEN CI 25-57 PER MEL 25-20-1.May 25, 2007 · N767NA · Boeing 767324SDR 2007UALA01690Oven · sparksFIRST CLASS OVEN NR 107 ELECTRICAL SPARKS FROM BEHIND. TURNED OFF, NO MORE SPARKS. [06-20-07] NO DAMAGE TO AC WIRING NOTED, FOUND GUIDE PIN PUSHED INTO OVEN. REPLACED CONVECTION OVEN,May 25, 2007 · N509UA · Boeing 757222SDR 2007UALA01555Oven · odorCREWS REPORTS ELECTRICAL BURNING ODOR IN CABIN. [06-26-07] PERFORMED MULTIPLE OPERATIONAL CHECKS AT VARIOUS STATIONS WITH NO FURTHER BURNING ODOR. OVEN WAS REPLACED 2 DAYS PRIOR, SO SUSPECT THAT ODOR WAS FROM DIRT OR DEBRIS BURNING OFF THAT WAS GATHERED WHILMay 20, 2007 · N813UA · Airbus A319131SDR MWEA070118Oven · smokeOVEN ON AIRCRAFT LEFT, SMOKES WHEN TURNED ON. CLEANED OVEN.May 19, 2007 · N917ME · Boeing 717200SDR MWEA070115Oven · smokeFLIGHT ATTENDANT REPORTED SMOKE BILLOWING FROM MIDDLE GALLEY OVEN. FOUND BURNT FOOD IN OVEN.May 14, 2007 · N906ME · Boeing 717200SDR NWAA071826314Controller · stuckDURING FLIGHT, GALLEY 2-C OVEN 2-45 WAS VERY HOT, AND SMELLED OF BURNING WIRES. PULLED CIRCUIT BREAKERS. FLIGHT CONTINUED ON AND LANDING WAS UNEVENTFUL. MAINTENANCE FOUND BUTTON STUCK ON OVEN CONTROLLER. REMOVED AND REPLACED OVEN CONTROLLER. OPERATIONAL May 11, 2007 · N674US · Boeing 747451SDR AALA20070828Oven · inoperativeMAN T95/10MAY - AFT GALLEY NUMBER ONE OVEN CIRCUIT BREAKER POPPED PRECEDED BY ELECTRICAL FUMES AND SMOKE ALARM. CIRCUIT BREAKER TRIPPED AND COLLARED. AIRCRAFT DISPATCHED TO BOS IN ACCORDANCE WITH PDL 25 99M. REPLACED AFT GALLEY NUMBER ONE OVEN IN BOS. SYSTMay 10, 2007 · N192AN · Boeing 757223SDR NWAA071806314Oven · contaminatedDURING FLIGHT, SMOKE FROM OVEN NR 2 IN GALLEY NR 2. FOUND RICE BURNED INSIDE OF OVEN. PULLED CIRCUIT BREAKERS. REQUIRED THE USE OF A HALON FIRE EXTINGUISHER. FLIGHT CONTINUED ON AND LANDING WAS UNEVENTFUL. MAINTENANCE REMOVED AND REPLACED OVEN, AND HALON May 10, 2007 · N674US · Boeing 747451SDR 2007UALA01411Motor · overheatedCART LIFT MOTOR NR 2 OVERHEATED AFTER CATERING SERVICE LOADED 8 FOOD CARTS. [SUP 06-01-07] REPLACED CART LIFT ACTUATOR MOTOR ASSY PER MM25-38-02. OP CHECKED GOOD.May 2, 2007 · N182UA · Boeing 747422SDR 2007UALA01388Chiller · dirtySMOKE ODOR REPORTED IN BUSINESS CLASS GALLEY CHILLER AREA. [SUP 05-29-07] REPLACED AIR CHILLER AS PER AMM 25-33-04. CLEANED DIRTY VENTS. CHECKED OKAY FOR SERVICE. SUSPECT CHILLER MOTOR OVERHEATED AS VENT BECAME RESTRICTED BY DEBRIS.May 2, 2007 · N654UA · Boeing 767322SDR DL76G070382Coffeemaker · odorACRID ODOR IN CABIN, CBR12 CLOSED RAN ALL CHILLERS OVENS RECIRC FANS GAINED ACCESS TO AFT CHILLERS AND EXHAUST FANS. NO FAULTS FOUND GAINED ACE TO RECIRC FANS NO FAULTS FOUND. FOUND AFT COFFEEMAKER LOC A ELECTRICALLY INOP. REPLACED SAME, OK FOR SERVICE.Apr 28, 2007 · N172DZ · Boeing 767332SDR DL76L070322Coffeemaker · smokeAFT COFFEE MAKER ON CAPT'S SIDE PRODUCED SMOKE WHEN TURNED ON. SMOKE QUIT WHEN COFFEE MAKER WAS TURNED OFF. CB'S WERE PULLED. RESET C/B FOR AFT COFFEE MAKER. MADE A POT OF COFFEE FROM EACH. ALL CKS OK. NO SMOKE NOTED AT ANY TIME.Apr 14, 2007 · N196DN · Boeing 767332SDR NWAA071323302Coffeemaker · odorDURING TAKEOFF AN ELECTRICAL ODOR FROM NR 2 GALLEY AND NR 1 COFFEEMAKER CIRCUIT BREAKER POPPED. ODOR WOULD NOT DISSIPATE, COFFEEMAKER REMAINED HOT. LANDING WAS UNEVENTFUL. FOUND STRONG ELECTRICAL SMELL EMITTING FROM THE BACK OF NR 1 COFFEEMAKER. COFFEEMAKEApr 13, 2007 · N802NW · Airbus A330323SDR 2007UALA01133Oven · odorOVEN 032 AUX B-C GALLEY SMOKES AND HAS BURNED PLASTIC ODOR. [SUP 05-04-07] REPLACED OVEN, OPS NORMALLY. BURN ODOR IS GONE. A/C OK FOR SERVICE.SUSPECT FOOD SERVICE WRAP FELL ON HEATING ELEMENTS.Apr 11, 2007 · N182UA · Boeing 747422SDR AALA20070621Coffeemaker · malfunctionedFLIGHT ATTENDANT SAW FLASH AND HEARD POP FROM COFFEEMAKER NUMBER ONE AND TWO IN FORWARD GALLEY FOLLOWED BY SMELL OF ELECTRICAL SMOKE FOR A COUPLE OF MINUTES. PULLED BOTH CIRCUIT BREAKERS ON COFFEE MAKER. REPLACED COFFEE MAKER NUMBER ONE AND INSPECTED WIRING Apr 10, 2007 · N363AA · Boeing 767323SDR NSVA20070089Receptacle · shortedSTRONG BURNING SMELL NEAR GALLEY. FA INFORMED CA OF BURNING SMELL 20 MIN PRIOR TO NORMAL IN GALLEY. CA INFORMED FA TO TURN OFF HOT JUGS. FA 5 MIN LATER SAID SMELL DECEASED CA AND FO DID NOT SMELL UNTIL AFTER LANDING , DURING TAXI. STRONG BANGLITE ODOR NOTEApr 8, 2007 · N233CJ · Saab 340BSDR 2007UALA01014Coffeemaker · smokeRTFL DUE TO CREW REPORT OF SMOKE IN THE CABIN. [SUP 05-04-07] SOURCE OF SMOKE WAS TRACED BACK TO A DEFECTIVE COFFEEMAKER IN THE AFT GALLEY. IT WAS DETERMINED THAT A FAULTY HEATER POWER RELAY CONTINUED TO SUPPLY POWER TO THE TANK HEATER ELEMENTS EVEN THOUGH TApr 3, 2007 · N480UA · Airbus A320232SDR DL76G070291Oven · odorGALLEY MID CABIN CENTER OVEN WON`T HEAT PROPERLY GIVES OFF ELECTRICAL ODOR WHEN HEATING. CLEANED CHECKED OPS NORMAL.Apr 3, 2007 · N1501P · Boeing 7673P6SDR DL76L070290Coffeemaker · dirtyCOFFEEMAKER ON CAPT SIDE HAS BURNING ODOR WHEN ON. REMOVED AND REPLACED BOTH REAR GALLEY COFFEEMAKERS AS PRECAUTION CAPT SIDE. FOUND COFFEEMAKER DRAINS CLOGGED WITH COFFEE GRINDS AND BURNED COFFEE ON DRAIN PLATE STRONG ODOR. OPERATED COFFEEMAKERS OVER HALF Apr 3, 2007 · N192DN · Boeing 767332SDR AALA20070594Oven · dirtyJFK INFLIGHT - NUMBER ONE OVEN IN FIRST CLASS SMOKING WHILE IN USE. OVEN WAS TURNED OFF AND SMALL PATCH CONTINUE TO GLOW AT LEFT SIDE OF HEATING ELEMENT. RETURNED TO JFK AND LANDED WITHOUT INCIDENT. CLEANED BURNED DEBRIS AND GREASE ON HEATING ELEMENT FOR NUApr 2, 2007 · N604AA · Boeing 757223SDR SWAA071695Coffeemaker · faultyF/A REPORTED ELECTRICAL ODOR COMING FROM AFT GALLEY COFFEEMAKER, F/A PULLED C/B AS PRECAUTIONARY MEASURE. INSPECTED AFT GALLEY AREA ISOLATED FAULT TO NR 1 COFFEEMAKER. REMOVED AND REPLACED NR 1 COFFEEMAKER PER MM.Apr 2, 2007 · N373SW · Boeing 7373H4SDR C2XA07TY016Thermal Switch · trippedFLT 2807, F/A NOTED THERMAL SWITCH FOR GALLEY POPPED IN FLIGHT WITH ASSOCIATED BURNING ODOR. AC RELEASED IAW MEL 25-60-02 (3) CAT D.Mar 29, 2007 · N14920 · Emb EMB145LRSDR AALA20070561Coffeemaker · smokeACRID ODOR THROUGH AIR CONDITIONING SYSTEM AND SMOKE REPORTED IN CABIN BY FLIGHT ATTENDANT, PASSENGERS, AND DEADHEADING CREW DURING CLIMB-OUT. CREW TURNED OFF GALLEY POWER AND SMOKE DISSIPATED AT FLIGHT LEVEL 050. FLIGHT CONTINUED TO DFW AND LANDED WITHOUT IMar 26, 2007 · N274AA · Doug DC982SDR C2XA07IA071Coffeemaker · odorIAH FLIGHT 2560, THE CREW REPORTED THAT THE COFFEEMAKER HAD A BURNING SMELL IN FLIGHT. THE AIRCRAFT LANDED AT IAH WITHOUT INCIDENT WHERE MAINTENANCE INSPECTED THE COFFEEMAKER, OPERATIONALLY CHECKED WITH NO DEFECTS, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO Mar 26, 2007 · N14116 · Emb EMB145XRSDR 2007UALA00906Chiller · malfunctionedF/A'S REPORTED C/B'S IN AFT GALLEY POPPED. F/A'S IN MID CABIN REPORTED SMELL PRIOR TO C/B POPPING. [SUP 4-20-07] ALL CART CONTROLLER CB'S REPORTED POPPED AT SAME TIME. RESET CB'S. RAN CART CONTROLLERS FOR 5 MINUTES EACH. COULD NOT REPEAT PROBLEM. SUSPECT Mar 25, 2007 · N646UA · Boeing 767322
Back to JASC 2530