JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR 2008UALA01025Chiller · shortedSMELL OF ELECTRICAL SMOKE LAST 5 MIN OF FLIGHT. AFT GALLEY, FWD CHILLER SHORTED. REPLACED CHILLER.Feb 23, 2008 · N457UA · Airbus A320232SDR NWAA080615523Oven · smokeFAR RIGHT FORWARD OVEN STARTED SMOKING, TURNED IT OFF AND BACK ON, AND IT STARTED SMOKING AGAIN, SO TURNED IT OFF AND PULLED THE C/B. MAINTENANCE REMOVED AND REPLACED FIRST CLASS OVEN, OPERATIONAL CHECKED GOOD, AND AIRCRAFT WAS RETURNED TO SERVICE.Feb 21, 2008 · N523US · Boeing 757251SDR DHLA200800015Receptacle · burnedFLT 445 - SMOKE IN ENTRY WAY AND OR MAIN CABIN IN FLT. RAN ALL ENGINES PER JRH 11.8, NO SMOKE IN ENTRY OR MAIN CABIN. FOUND ELECTRICAL ODOR AT HOT CUP RECEPTICAL. TRANSFERRED "HOT CUP" TO DMI NR 31815, MEL REF 25-13. DMI EXPIRES JUNE 22, 2008, CAT "D". GAFeb 21, 2008 · N873SJ · Doug DC873FSDR NWAA080595635Oven · odorJUST PRIOR TO DESCENT FLIGHT ATTENDANT ADVISED A HOT/SMOKY ODOR FROM THE FRONT GALLEY, ALL COMPONENTS TURNED OFF AND CIRCUIT BREAKERS PULLED AS A PRECAUTION, AND ODOR DID DISSIPATE. FLIGHT CONTINUED ON AND LANDING WAS UNEVENTFUL. MAINTENANCE FOUND ODOR AND AFeb 17, 2008 · N535US · Boeing 757251SDR A6WA200840095Coffeemaker · malfunctionedIN FLIGHT WHEN FLIGHT ATTENDANT TURNED ON COFFEE MAKER IT STARTED TO SMOKE. STOPPED SMOKING WHEN IT WAS TURNED OFF. REMOVED AND REPLACED COFFEE MAKER. (K)Feb 13, 2008 · N464AW · Cndair CL6002B19SDR 2008UALA00709Coffeemaker · faultyELECTRICAL SMELL EMANATING FROM THE AFT GALLEY. UNKNOWN (POSSIBLE SHORT WITHIN COFFEE MAKER). REPLACED COFFEEMAKER AND OPS CHECKED OK, NO SMELL, NO REPEATS.Feb 6, 2008 · N839UA · Airbus A319131SDR DL757080156Coffeemaker · smokeAT CRUISE ALT 39000, FLT ATTENDANTS REPORTED SMOKE IN THE WASTE CAN AREA OF THE REAR GALLEY. REPORTED NO VISIBLE FLAMES. MADE AN EMERGENCY LANDING AT BWI. UPON ARRIVAL AT THE GATE AN INSPECTION OF THE TRASH CAN REVEALED A COFFEE GROUND BAG HAD IGNITED. FIRFeb 2, 2008 · N670DN · Boeing 757232SDR DL764080135Oven · overheatedFIRST GLASS OVEN CB POPPED AND ELECTRICAL SMELL. REPLACED NR 2 OVEN. CKS GOOD. REMOVED MCO AND PLACARD.Jan 28, 2008 · N842MH · Boeing 767432ERSDR AALA200800183Oven · smokeVVI INFLIGHT 922/27JAN - CREW REPORTED SMOKE IN CABIN. TURNED OFF RIGHT AIR RECIRCULATION FAN AND SMOKE DISSIPATED. INSPECTED AND CLEANED AFT GALLEY NUMBER TWO OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.Jan 27, 2008 · N617AM · Boeing 757223SDR 2008UALA00449Oven · smokeAFT GALLEY HAD SMOKE AND CONTROL PANEL VERY HOT. ALL AFT GALLEY C/B PULLED. SMOKE HAS DISSIPATED. OVEN SHORT -FOUND OVEN R52 SMOKING. REPLACED OVEN. TURNED ON ALL GALLEY EQUIPMENT NO SMOKE NOTED IN AFT GALLEY,CONTROL PANEL IS NORMAL. ACFT OK FOR SERVICE.Jan 26, 2008 · N798UA · Boeing 777222SDR DLM88080114Coffeemaker · odorELECTRICAL ODOR IN CABIN. REPLACED COFFEEMAKER, RAN A/C FOR SEVERAL HOURS. NO OTHER ODORS NOTED.Jan 24, 2008 · N920DL · Doug MD88SDR WRLA2008014Oven · defectiveOKBK/EDDP. OVEN 509 MID GALLEY INOP BURNING SMELL WHEN USED. REMOVED AND REPLACED MID GALLEY OVEN 509 REF MM 25-33-00. DMI CLOSED.Jan 23, 2008 · N277WA · Doug MD11SDR ABXA080022Oven · shortedMICROWAVE SHORTED OUT WHEN IN USE. TOP RIGHT BACK SIDE SPARKED AND FIRE CAME OUT. CIRCUIT BREAKERS PULLED FOR GALLEY. REMOVED AND REPLACED MICROWAVE. OPS CHECKED GOOD IAW B767 MM 25-31-00.Jan 18, 2008 · N744AX · Boeing 767232SDR ABXA08022Oven · shortedMICROWAVE SHORTED OUT WHEN IN USE. TOP RIGHT BACK SIDE SPARKED AND FIRE CAME OUT. CIRCUIT BREAKERS PULLED FOR GALLEY. REMOVED AND REPLACED MICROWAVE. OPS CHECKED GOOD IAW B767 MM 25-31-00.Jan 18, 2008 · N744AX · Boeing 767232SDR CALA0800006Oven · malfunctionedAFT GALLEY OVEN 810/809 STARTED TO SMOKE. PULLED C/B FOR OVEN 708-709-809-810 TO ISOLATE. SMOKE STOPPED. LEFT C/BS OUT FOR DURATION OF FLIGHT. SOURCE OF SMOKE/ODOR FOUND OVEN 809 FAN INOP. REMOVED OVEN 810/809.Jan 7, 2008 · N69020 · Boeing 777224SDR CALA0700791Oven · overheatedLAV SMOKE INDICATION ON EICAS. THE LEFT AFT LAV SMOKE DETECTOR WAS ACTIVATED. NO FLAME WAS NOTICED, BUT THE A/C DID HAVE A SMOKE (ELECTRICAL) SMELL. DIVERTED TO LAS. PER F/A WORKING AFT GALLEY, WHEN DOOR TO NR 1 OVEN OPENED SMOKE CAME OUT AND AFT LAV SMOKEDec 27, 2007 · N13138 · Boeing 757224SDR HNAA0800001Hot Water Pot · burnedBURNING ODOR COMING FROM F/A HANDSET. AFTER INSPECTION, IT WAS DETERMINED THE ODOR TO BE COMING FROM NR 1 HOT WATER BOTTLE RECEPTACLE. REMOVED AND REPLACED RECEPTACLE AND WIRING RING TERMINALS. WIRING FOUND TO BE IN GOOD CONDITION.Dec 21, 2007 · N825EX · Dhav DHC8102SDR 2007UALA05153Oven · contaminatedFLT DIVERTED DUE TO AN ELECTRICAL ODOR IN THE AFT MAIN CABIN AREA. FOUND MELTED PLASTIC IN R51 OVEN. REMOVE PLASTIC. CHECKED ALL RECIRCULATION FANS, OPS CHECKED GOOD. CHECKED AFT GALLEY AREAS, INCLUDING CEILING AREAS, AC DUCTING, AFT CARGO & AFT LAV. REDec 19, 2007 · N206UA · Boeing 777222SDR AMTA200700716Oven · unserviceableF/A REPORTED (HEAVY SMOKE IN THE FORWARD GALLEY, OVEN WAS ON, REMOVED POWER) WHITE SMOKE (ELECTRICAL BURNING SMELL PERSISTED) EMERGENCY DECLARED, RETURNED TO DEPARTURE. SMOKE SLOWLY DISSIPATED. REMOVED AND REPLACED OVEN IAW MM CHAP 25, OPS CHECKS NORMAL. (Dec 18, 2007 · N552TZ · Boeing 75733NSDR HNAA0700295Galley · odorELECTRICAL ODOR IN CABIN. FLIGHT 4165, LGA TO ROA. LGA MNT PERFORMED HIDDEN DAMAGE INSPECTION AND FOUND HOT JUG IN NR 1 POSITION OVERHEATED AND CAUSING ODOR. REMOVED HOT JUG AS PRECAUTION, ITEM PLACED ON MEL. ROA MTN REMOVED AND REPLACED HOT JUG.Dec 17, 2007 · N982HA · Dhav DHC8102SDR WRLA2007134Oven · faultyDURING OVEN OPERATIONS, ELECTRICAL BURNING ODOR DETECTED. OVEN SHUT OFF AND BREAKERS PULLED. ODOR WENT AWAY. REMOVED AND REPLACED OVEN IAW MM 25-35-10. OPS CHECK GOOD.Dec 10, 2007 · N276WA · Doug MD11FSDR DL764071580Oven · unserviceableFAS REPORTED A SCREECHING SOUND WHEN STARTING FWD NR 1 OVEN. SUBSEQUENT HOT ELECTRICAL SMELL IN FWD GALLEY. FWD OVENS WERE SHUT OFF AND SMELL DISSIPATED. NR 1 OVEN IS BELIEVED TO BE SOURCE OF ODOR. PULLED FWD GALLEY U-33 CIRCUIT BREAKER AS PRECAUTION. RESDec 1, 2007 · N825MH · Boeing 767432ERSDR 2007FA0001092Oven · failedFLIGHT CREW REPORTED THE ODOR OF ELECTRICAL SMOKE IN THE GALLEY. THE ODOR WAS COMING FROM THE OVEN, THEN THE OVEN CB OPENED (POP). THE OVEN WAS REMOVED AND REPLACED WITH A NEW UNIT. (K)Nov 30, 2007 · N607PM · Gulstm GVSPG550SDR 2007UALA04869Oven · faultyOVEN R-52 WILL NOT TURN OFF. OVEN WAS SMOKING AND C/B WAS PULLED BY CREW PER SAM. POWER SWITCH STAYS IN ALL THE TIME, REPLACED OVEN. AC OK FOR SERVICE.Nov 28, 2007 · N776UA · Boeing 777222SDR DL757071554Chiller · overheatedDURING FLIGHT, BURNING ODOR DETECTED IN FORWARD GALLEY. ALL CIRCUIT BREAKERS WERE PULLED. FOUND INSULATION INSIDE CHILLER/FREEZER MELTED AND BURNED. CHECKED POWER TO UNIT ALL 3 PHASES CHECK OK. REPLACED CHILLER/FREEZER. CHECKS GOOD. OK TO CLEAR PERNov 25, 2007 · N617DL · Boeing 757232SDR CA071127002Coffeemaker · sparks(CAN) DURING FLIGHT, THE F/A REPORTED THE FWD COFFEE MAKER/WATER BOILER OVERHEATING AND NOTICED SOME SPARK COMING FROM THE UNIT. THE UNIT WAS DEACTIVATED. THE UNIT WAS REPLACED BY MAINTENANCE AND ROUTED TO THE REPAIR SHOP FOR INVESTIGATION. (TC NR 20071127002)Nov 21, 2007 · Airbus A310300SDR MWEA070279Oven · inoperativeFLIGHT ATTENDANT REPORTED NR 3 OVEN MADE A STRANGE SOUND WHEN TURNED ON, FOLLOWED BY A ELECTRICAL SMELL. REMOVED AND REPLACED NR 3 OVEN.Nov 4, 2007 · N908ME · Boeing 717200SDR DL777071408Oven · odorF/C GALLEY OVENS (BOTH) OVERHEATS AND HAS ELECT ODOR. ODOR DISSIPATED WITH BOTH OVEN C/B`S PULLED. FWD TO MCO AND PLACARD PER MEL 25-20-01G. OTHER ITEMS IN FWD GALLEY CHECKED, NO PROBLEMS FOUND. RAN BOTH OVENS FOR 1 HR NOTED NO ELECTRICAL ODOR. OVENS OK SNov 2, 2007 · N861DA · Boeing 777232SDR C2XA07ON025Coffeemaker · smokeFLT 216 - SAT TO SMF - CREW REPORTED RIGHT COFFEE POT WAS SMOKING A/C WAS RELEASED ON MEL 25-60-02/03 CAT D CONTROL 132221. A/C ARRIVED TO ONT FOR SVC/RTN CHECKS AND OVERNIGHT INSPECTION. MX BREWED COFFEE SEVERAL TIMES AND NO SMOKE WAS NOTED AT ANY TIME, OPENov 2, 2007 · N11194 · Emb EMB145XRSDR DL76G071357Fan · seizedPOSSIBLE AIR CONDITIONING TRANSIENT SMELL AT FL380. DESCENDED TO FL240 TURNED OFF RECIRC FANS, NO FURTHER SMELL. AFTER LANDING FLT ATT REPORT ELECTRICAL SMELL FORM MID GALLEY. UPON INSPECTION FOUND MID GALLEY AFT LOWER OVEN FAN SEIZED. ALSO ELECT SMELL PREOct 15, 2007 · N174DZ · Boeing 767332SDR SWIA200718783Coffeemaker · odorCREW REPORTS BURNING ODOR COMING FROM COFFEEMAKERS. REPLACED NR 1 AND NR 2 COFFEEMAKERS AS REQUIRED. Oct 14, 2007 · N958SW · Cndair CL6002B19SDR ZZDA2007284Coffeemaker · odorDURING DESCENT F/A ADVISED OF SMOKE IN THE CABIN. IN FLIGHT EMERGENCY WAS DECLARED. ALL CIRCUIT BREAKERS SET & GALLEY POWER SWITCH THEN BEING TURNED OFF. OPERATED ALL NORMAL OPERATIONS WITHIN THE GALLEY FOUND NR 3 COFFEEMAKER TO BE EMITTING A FOUL ODOR. REOct 11, 2007 · N895AT · Boeing 717200SDR DL75E071334Oven · smokeFWD GALLEY NR 1 OVEN REPORTED SMOKE AFTER OVEN FOOD SPILL. CLEANED OVEN THEN CYCLED OVEN FOR 2 HRS OK FOR SVC MCO/PL RMVD.Oct 10, 2007 · N707TW · Boeing 7572Q8SDR QXEA200701534Hot Water Pot · odorBZN - ON FLIGHT NUMBER 2311, FLIGHT ATTENDANT REPORTS MAPCOS HAVE ELECTRIC SMELL. MAINTENANCE REMOVED AND REPLACED HOT WATER JUGS. NO DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.Oct 8, 2007 · N409QX · Bombdr DHC8402SDR DL76L071319Oven · dirtyFLIGHT ATTENDANT REPORTS ELEC OR HOT METAL ODOR IN MID GALLEY. TURNED OFF OVEN AND CHILLER AND OPENED CIRCUIT BREAKERS IN MID GALLEY. OPERATED COFFEEMAKERS. OVENS AND CHILLERS FOR SEVERAL HRS ON GND FOUND ODOR COMING FROM OVEN TRAYS, NOTIFIED CATERING TO REOct 8, 2007 · N199DN · Boeing 767332SDR C2XA07IA216Coffeemaker · odorIAH - FLIGHT 2145, THE CREW REPORTED AN ELECTRICAL BURNING ODOR COMING FROM ABOVE THE COFFEE POTS. MAINTENANCE OPERATIONALLY CHECKED BOTH COFFEEMAKERS WITH NO DEFECTS, AND FOUND THE ODOR TO BE COMING FROM OLD COFFEE IN THE POTS. THE AIRCRAFT WAS APPROVED FOROct 3, 2007 · N14998 · Emb EMB145LRSDR 2007UALA03841Oven · odorOVEN B43 OMITS ELECTRICAL BURNING ODOR. 10-19-07 REPLACED GALLEY FOOD CART CONTROLLER "PIG TAIL". OP CHECKS GOOD.Sep 23, 2007 · N118UA · Boeing 747422SDR TRAX200701367Coffeemaker · odorCLIMBING THRU F260 TO F300 HAD A STRONG SMOKE LIKE ODOR. SMELLED LIKE BURNING RUBBER OR PLASTIC. F/A REPORTED, BEFORE DEPARTURE COFFEE WAS SPILLED IN THE COFFEEMAKER.Sep 17, 2007 · N857AS · Cndair CL6002B19SDR NWAA073046309Controller · odorDURING FLIGHT, FLIGHT ATTENDANT REPORTED OVEN 2-7 HAS AN ODOR OF BURNED WIRE. MAINTENANCE REPLACED OVEN CONTROLLER. OPERATIONAL CHECKED GOOD AND AIRCRAFT RETURNED TO SERVICE.Sep 11, 2007 · N669US · Boeing 747451SDR TRAX200701335Coffeemaker · malfunctionedIN FLIGHT, F/A REPORTING A BURNED ODOR SMELL COMING FROM COFFEEMAKER AND ADJACENT WALL IS VERY HOT. PULLED GALLEY COFFEEMAKER C/B AND ODOR AND HEAT WENT AWAY.Sep 9, 2007 · N978EV · Cndair CL6002B19SDR ZZDA2007265Coffeemaker · defectiveBOTH CABIN AND FLIGHT CREW SMELLED VERY STRONG ODOR THAT MIGHT HAVE BEEN SMOKE, WITHIN 15 SEC OF NOTICING THE SMELL IT HAD DISSIPATED. CREW STATED, SAW EMERGENCY LIGHTS FLASH AND HEARD A POP OR CLICK BY L1 DOOR WHEN ODOR WAS SMELLED. REMOVED AND REPLACED GALAug 30, 2007 · N957AT · Boeing 717200SDR SWIA200718652Unknown · odorFLT 5860 - FLIGHT ATTENDANT REPORTS BURNING SMELL IN GALLEY. INSPECTED GALLEY HEAT, FAN, LIGHTS AND POTABLE WATER SYSTEM. COULD NOT DUPLICATE BURNING SMELL.Aug 27, 2007 · N962SW · Cndair CL6002B19SDR AALA20071600Oven · smokeLHR INFLIGHT T086/22AUG - NUMBER TWO OVEN IN FIRST CLASS GALLEY SMOKING. FLIGHT ATTENDANT TURNED OVEN OFF. CIRCUIT BREAKERS PULLED AND BANDED. CLEANED BURNT RESIDUE FROM NUMBER TWO OVEN IN FIRST CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Aug 22, 2007 · N779AN · Boeing 777223SDR 2007UALA03238Oven · fireGALLEY OVEN R42 CAUGHT ON FIRE. FIRE EXTINGUISED WITH HALON. REPLACED R42 GALLEY OVEN. OPS CKS OK. SUSPECT SHORT IN HEATING ELEMENT.Aug 16, 2007 · N657UA · Boeing 767322SDR SWIA200718610Coffeemaker · odorFLIGHT ATTENDANT REPORTS BURNING ODOR FROM GALLEY, FLIGHT NR 6205. REPLACED LEFT HOT JUG PER CRJ MM 25-32-02. OPS CHECKED GOOD.Aug 15, 2007 · N986SW · Cndair CL6002B19SDR 2007UALA03121Oven · odorAFT RIGHT OVEN HAS ELECTRICAL ODOR. ODOR WENT AWAY AFTER LANDING AND NEVER RETURNED. ALL VISUAL CHECKS OF COMPONENTS COMPLETED, NO UNUSUAL DEFECTS DEFECTS. NO REPEATS SINCE. Aug 10, 2007 · N422UA · Airbus A320232SDR SA07064Chiller · smokeLGA - CABIN CREW REPORTED AN ELECTRICAL ODOR IN THE AFT GALLEY. WHEN THE CREW SECURED THE CHILLERS AND COFFEE POTS, THE ODOR SUBSIDED. MAINTENANCE REPLACED THE AFT CHILLER. OPERATIONALLY CHECKS OK.Aug 9, 2007 · N741UW · Airbus A319112SDR 2007UALA03060Coffeemaker · smokeFOUND SMOKE IN CABIN. SMOKE IN CABIN CAUSED BY A BURNED COFFEE PACK. COFFEE PACKET WAS ON THE DUAL COFFEE WARMER IN FLIGHT AND WAS SMOLDERING. CLEANED AREA AND OPERATED WARMING PLATES FOR 30 MINUTES. EVERYTHING CHECKED NORMAL AND BACK PLATE WAS COOL.Aug 6, 2007 · N526UA · Boeing 757222SDR DL764070961Oven · odorFWD GALLEY NR 2 OVEN MADE POPPING NOISE AND BURNING ODOR. FWD TO MCO AND PLACARD PER MEL 25-20-01H. DEACTIVATED C/B COLLARED. REPLACED NR 2 FWD OVEN, OPS NOW CKS GOOD. REMOVED MCO/PLAC.Jul 27, 2007 · N827MH · Boeing 767432ERSDR DXTA200702351Oven · odorWHITE ODORLESS SMOKE POURS OUT OF THE GALLEY CONVECTIVE OVEN WHEN OPERATING. CLEANED OUT INSIDE OF OVEN. OPERATED AT HIGHEST TEMPERATURE SETTING FOR 15 MINUTES. VERY MINIMAL SMOKE NOTED AFTER CLEANING. IAW F2000 M/M 20-314Jul 19, 2007 · N290QS · Amd FALCON2000
Back to JASC 2530