SDR DL76G070229Oven · inoperativeFOUND GALLEY REAR CENTER OVEN INOP, FWD TO MCO AND PLACARD PER MEL 25-20-01H CB PULLED AND COLLARED DUE TO AFT GALLEY OVEN NR 6 CB POPPED WITH REPORT OF VISABLE ELECTRIC FLASH. REPLACED OVEN CKS GOOD REMOVED MCO AND PLAC.SDR NWAA071136314Oven · contaminatedDURING CRUISE, THE FLIGHT ATTENDANTS NOTICED AN ODOR AT GALLEY 2. SMOKE SEEN COMING OUT OF THE OVEN, (NO FIRE), PER F/A INCIDENT REPORT "SPARKLES" OBSERVED AT BOTTOM OF OVEN. 4 HALOGEN FIRE BOTTLES WERE DISCHARGED. CIRCUIT BREAKERS WERE PULLED. NO EMERGENCSDR QXEA200700395Unknown · odorSEA FLIGHT NR 2017, BURNING RUBBER ODOR FROM MAPCO, GALLEY EQUIPMENT INOP. MAINTENANCE PLACED MAPCO ON MEL.SDR C2XA07CL033Coffeemaker · smokeCMH FLIGHT 2930 THE CREW REPORTED THE COFFEE POT WAS SMOKING WHEN TURNED ON.THE COFFEE POT WAS PLACED ON MEL AND THE AIRCRAFT WAS RELEASED FOR SERVICE. MAINTENANCE INSPECTED AND REPLACED THE NR 2 COFFEE POT BREWER.OPERATIONAL CHECKS WERE GOOD.SDR DL76G070215Coffeemaker · odorSTRONG ELEC SMELL IN AFT CABIN DURING CLIMB-OUT. INSPECTED A/C DURING VERIFICATION FLT. TURNED ON ALL OVENS/COFFEE MAKERS/AND CHILLERS IN AFT GALLEY. OPENED UP CEILING PANELS IN AFT GALLEY/CABIN. CHECKED DOOR HEATERS DUCTING/OXY/CANISTERS AND FANS. CHECKESDR NWAA070993303Oven · smokeDURING CRUISE FLIGHT ATTENDANTS REPORTED SMOKE AT CEILING AREA ABOVE AFT GALLEY, PULLED CIRCUIT BREAKERS AND SMOKE APPEARED TO STOP. DIVERTED TO LGW AND LANDING WAS UNEVENTFUL. TESTED ALL HOT PLATES, COFFEE MAKERS, BUN WARMERS, CHILLERS, OVENS AND FOUND NR 2SDR DL764070203Oven · contaminatedOVEN POS 401 SMOKES SO MUCH IT IS UNUSABLE FOUND PLASTIC SHEET ON TOP OF OVEN FAN. REMOVED DEBRIS. NOW OVEN OPERATES GOOD.SDR CALA0700125Oven · overheatedTHE NR 1 OVEN OVERHEATED AND BECAME VERY HOT WITH SMOKE COMING FROM THE OVEN. THE FLIGHT ATTENDANT PULLED THE OVEN CIRCUIT BREAKER AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. THE NR 1 OVEN WAS REMOVED AND REPLACED IAW IFM 25-36. SDR SWAA071255Coffeemaker · faultyF/A REPORTS BURNING SMELL FROM FWD COFFEEMAKER. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR XXUA200701037Oven · inoperativeOVEN NR 2 AFT INOPERATIVE (CB PULLED AND COLLARED AFTER SEVERE SMOKE) SPILLAGE NOTED. REPLACED OVEN IAW MM 25-31-00, OPS CHECKS NORMAL.SDR COMA0760176Rack · dirtyFLIGHT 5008 - EN ROUTE RSW-CMH CREW REPORTED THE PRESENCE OF STRONG ELECTRICAL SMOKE SMELL IN THE COCKPIT, FLIGHT DIVERTED TO MCO. REPLACED THE COFFEEMAKER RACK.SDR AWXA200700197Oven · fireOVEN FIRE, F/A REPORTED FIRE IN OVEN NR 4, CARDBOARD FROM FOOD TRAY CAUGHT FIRE. THE F/A EXTINGUISHED WITH PORTABLE HALON FIRE EXTINGUISHER. MX REMOVED AND REPLACED AFT GALLEY HALON EXTINGUISHER AND PLACED THE OVEN ON MEL.SDR SWAA070605Coffeemaker · faultyAFT COFFEEMAKER HAD BURNING SMELL DURING FLIGHT, OPENED C/B SMELL DISSIPATED. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR AALA20070270Oven · inoperativeORD INFLIGHT FERRY FLIGHT T1173/03FEB - ON SHORT FINAL, CREW REPORTED ELECTRICAL BURNING SMELL AND SMOKE IN FIRST CLASS GALLEY. ALL OVENS WERE OFF. TURNED GALLEY POWER AND RECIRCULATION FANS OFF WITH NO HELP. LANDED ORD WITHOUT INCIDENT. REPLACED FIRST CLASDR SWIA200717784Coffeemaker · odorFLIGHT ATTENDANT REPORTED OVERHEATED ODOR COMING OUT OF HOT JUGS. SWITCH WAS TURNED OFF AND ODOR DISAPPEARED. REPLACED HOT JUG WITH SERVICEABLE UNIT IAW 25-60-00. OPERATIONAL CHECKS GOOD.SDR 0700373269Coffeemaker · odorFLIGHT ATTENDANT REPORTED LARGE WATER MESS IN AFT GALLEY, THEN ODOR OF ELECTRICAL FUMES AND SMOKE. FLIGHT CREW REMOVED POWER FROM GALLEY, OBSERVATION REVEALED THAT ODOR STILL PERSISTED, NO SMOKE. AN EMERGENCY WAS DECLARED AND THE FLIGHT DIVERTED INTO DTW. ASDR AALA20070144Coffeemaker · inoperativeLHR INLIGHT - SMOKE CREW REST MAIN MESSAGE ILLIMINATED AND FLIGHT ATTENDANT ADVISED A STRONG ODOR AND HIGH TEMPERATURE WAS IN THE AREA OF COFFEEMAKERS 10, 11, 12, AND 13. COFFEEMAKERS WERE IMMEDIATELY SHUT OFF AND THE ODOR AND HEAT SUBSIDED. LANDED LHR WITHOSDR 2007UALA00103Oven · smokeOVEN 105R11 WAS SMOKING IN FLT SHUT OFF POWER AND SMOKE STOPPED. REPLACED OVEN. OPS CHECKED GOOD.SDR AALA20070063Oven · dirtySJU INFLIGHT T1044/11JAN AUA TO BOS - FIRST CLASS GALLEY OVEN BEGAN SMOKING. SMELLED LIKE ORGANIC MATERIAL. OVEN TEMPERATURE WAS SET AT 175 AND THE OVERHEAT LIGHT DID NOT COME ON. THE NUMBER ONE AND NUMBER TWO FIRST CLASS OVENS WERE TURNED OFF AND THE CIRCUSDR WRLA2007003Oven · smokeMID GALLEY OVEN NR 2 STOPPED WORKING, C/B PULLED. ELECTRICAL SMOKE WAS SENSED ON LEFT SIDE OF VENT, NO SMOKE WAS EVIDENT ALTHOUGH SMELL WAS NOTICEABLE. OPS CHECKED MID OVENS, NO SIGN OF ELECTRICAL SMOKE OR ODOR. COOKED WITH MID GALLEY OVENS FOR MEAL SERVICESDR ASAA0741357Oven · odorFWD GALLEY OVEN CAUSES STRONG ELEC ODOR AND TRIPS GALLEY PWR. DEFERRED OVENS INOP COLLARDED CB'S PER MEL.SDR AALA20070032Coffeemaker · sparksLHR INFLIGHT T116/06JAN - DURING CLIMB FROM JFK FLIGHT ATTENDANT REPORTED SPARKING UNDER NUMBER 17 COFFEEMAKER IN AFT GALLEY WHEN TURNED ON. PULLED CIRCUIT BREAKER AS PRECAUTION. NO FAULTS FOUND ON AIRCRAFT WIRING TO COFFEEMAKER NUMBER 17 IN AFT GALLEY. RESDR 136001042007Heater · odorSMOKE AND ODOR EMTTED FROM GALLEY HOT CUP.SDR TSAA0725002Oven · smokeFLIGHT 476 OGG-SAN, DURING CRUISE FLIGHT, A FLIGHT ATTENDANT NOTICED SMOKE FROM THE RIGHT OUTBOARD OVEN IN THE AFT GALLEY. THE FLIGHT ATTENDANTS TURNED OFF THE OVEN AND THE SMOKE DISSIPATED. THE FLIGHT CONTINUED TO SAN WITHOUT FURTHER INCIDENT. MAINTENANCE SDR AALA20070236Coffeemaker · malfunctionedLAX INFLIGHT T170/01FEB - CAPTAIN REPORTED SEEING SMOKE AROUND NUMBER 10 AND 11 COFFEE MAKERS AND SMELL OF BURNING INSULATION. CIRCUIT BREAKERS POPPED. FOUND THE NUMBER 11 COFFEE MAKER BLEW TWO HEATING ELEMENTS OUT OF WATER TANK SPRAYING WHITE POWDER ALL BEHSDR SWAA065078Coffeemaker · malfunctionedFLIGHT ATTENDANT REPORTED SMOKE AND SPARKS FROM AFT COFFEEMAKER. INSPECTED AFT GALLEY AREA, NO EVIDENCE OF SMOKE, ARCHING OR SPARKS. REMOVED AND REPLACED COFFEEMAKERS PER MM AS PRECAUTION.SDR TSAA0625120Oven · odorFLT 442 HNL-OAK: DURING FLIGHT, THE CREW NOTED A BURNING ODOR COMING FROM THE NR 1 OVEN IN THE AFT GALLEY. THE CREW TURNED OFF OVEN AND THE ODOR DISSIPATED SHORTLY AFTER. AIRCRAFT LANDED IN OAK WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE AFT GALLEY NSDR 0602779884Oven · smokeWHEN FLIGHT ATTENDANT ATTEMPTED TO UTILIZE THE OVEN A THICK WHITE SMOKE DEVELOPED FROM THE ELECTRICAL WIRE CONNECTION AREA AT BACK WALL. SMOKE SMELLED OF ELECTRICAL BURNING AND DID NOT EMANATE FROM BURNING SPILLAGE INSIDE THE OVEN. AN INOPERATIVE OVEN FAN WASDR 2006UALA02379Coffeemaker · odorELECTRICAL ODOR NOTICED IN THE AFT GALLEY. ODOR MORE PRONOUNCED AROUND DOOR 2L. NO ELECTRICAL ODOR DETECTED. NOTICE GLYCOL ODOR. ALSO, BURNED COFFEE ODOR COMING FROM COFFEE MAKER 41. RAN PACKS FULL HOT AND COFFEE MAKER HOT PLATES. DETERMINED ODOR IS COMISDR CALA0600537Oven · overheatedTHE FORWARD GALLEY 103 OVEN WAS UNUSUALLY HOT AND HAD AN ELECTRICAL ODOR PRIOR TO STARTING IT. THE CIRCUIT BREAKER WAS PULLED. THE OVEN WAS REMOVED AND REPLACED, OPERATIONAL CHECKS WERE GOOD.SDR DL764061009Oven · smokeFLIGHT ATTENDANT REPORTED SMOKE AND RED GLOW ON TOP OF OVEN NUMBER 1 ON POWER-UP. REMOVED OVEN AND INSPECTED WIRES. ALL OK, REMOVED AND TIED BACK CONNECTOR, PULLED AND COLLARED OVEN C/B AND DEFERRED PER MEL. REPLACED OVEN MCO/PLAC REMOVED.SDR CALA0600536Oven · malfunctionedTHE FIRST CLASS GALLEY OVEN 205 BEGAN TO SMOKE. CIRCUIT BREAKERS WERE PULLED AND THE SMOKE DISSIPATED. THE OVEN WAS REMOVED AND REPLACED AND OPERATIONAL CHECKS WERE GOOD WITH NO DEFECTS NOTED.SDR XXUA200611034Oven · smokeOVEN NR 6 WAS SMOKING WHEN IN USE. SUSPENDED COOKING. INSPECTED OVEN AND FOUND BURNT PLASTIC IN OVEN FAN GRILL. CLEANED INTERIOR OF FAN AND OPERATIONAL CHECKS NORMAL. OK FOR CONTINUED SERVICE.SDR A6WA200640391Coffeemaker · odorCOFFEEMAKER HAS BURNING SMELL WHEN BREWING. NO SMELL WHEN OFF. PULLED AND COLLARED COFFEEMAKER CIRCUIT BREAKER. PLACARDED AND PLACED ON MEL. REMOVED AND REPLACED COFFEEMAKER IAW AMM. OPS CHECK NORMAL. REMOVED PLACARD AND MEL. (K)SDR AALA20061084Coffeemaker · defectiveLGA INFLIGHT T386/19NOV - FLIGHT ATTENDANT REPORTED HEARING TWO POPS AND SAW A SMALL AMOUNT OF WHITE SMOKE COMING FROM THE AFT GALLEY NUMBER FOUR COFFEE MAKER. FOUND NUMBER FOUR COFFEE MAKER HEATER ELEMENT CONNECTORS DISCONNECTED WITH EVIDENCE OF ARCHING. RESDR QXEA200603139Door · damagedC4 PDX - HINGE MOUNT EXTENSION FOR GALLEY TRASH CAN ACCESS DOOR HAS A SCREW BROKEN OFF IN THE BOTTOM MOUNT HOLE. REPAIRED IAW DRILLED OUT BROKEN SCREW AND REMOVED THE DAMAGED INSERT AND INSTALLED A NEW INSERT IN ITS PLACE.SDR QXEA200602960Coffeemaker · burnedSEA FLIGHT NR 2392: FLIGHT ATTENDANT REPORTS LT COFFEMAKER IS MAKING SPARKING ELECTRICAL SOUNDS AND BOILING THE WATER INSIDE. MAINTENANCE REMOVED AND REPLACED LT COFFEMAKER WITH NO OTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR AWXA200601894Oven · malfunctionedLAS - BS - FLIGHT ATTENDANT REPORTED BURNING ODOR NR 1 OVEN NO VISIBLE RESIDUE. MAINTENANCE INSERTED DIFFERENT OVEN IN NR 1 OVEN RACK, OPS CK GOOD.SDR SIMA200630501Coffeemaker · dirtyRUBBER BURNING SMELL BY SEAT 1B. FOUND SMELL TO BE COMING FROM BURNED COFFEE ON COFFEE HOT PLATE. REMOVED BURNED COFFEE FROM HOT PLATE. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE. (M)SDR DL76L060901Oven · burnedMARKS AROUND OVEN AFT GALLEY TOP RIGHT F/O SIDE. FWD TO MCO AND PLACARD PER MEL M25-20-01H DEFECT, CONFIRMED-SCORCH MARKS PRESENT AT DIVIDER WALL-SEAL. INSPECTED SATIS, HOWEVER, SEAL MATING SURFACE MISSING IN LOWER CORNER SECTION. NR 3 OVEN CONSIDERED AS INSDR DL777060900Oven · inoperativeOVEN 1 CIRCUIT BREAKER PULLED IN ASSOC WITH BURNING ELEC SMELL. ACTIVATED OVEN FWD TO MCO AND PLAC PER MEL 25-20-01G. REPLACED OVEN AND OPERATED OPS CKS OK MCO AND PLACARD REMOVED.SDR DL75A060887Coffeemaker · failedPOP WITH SMOKE OUT OF COFFEE MAKER, RETURNING TO GATE TO HAVE IT CHECKED OUT. NO HISTORY. MAINTENANCE REMOVED AND INSPECTED COFFEE MAKER. CIRCUIT BREAKER TO REMAIN PULLED AND FWD COFFEE MAKER TO MCO/PLAC. REPLACED DC CONVERTER, CKS GOOD.SDR AWXA200601830Coffeemaker · burnedLAS - BURNING SMELL - FWD COFFEE MAKER INOP, BURNING SMELL UNTIL C/B PULLED. REMOVED AND REPLACED NR 1 COFFEE MAKER PER TASK CARD R1D25303.SDR ASAA0681125Coffeemaker · defectiveAFT GALLEY COFFEEMAKER BEGAN TO SMOKE DURING FLIGHT. PERFORMED AIR TURNBACK. REMOVED DEFECTIVE COFFEEMAKER.SDR SWIA200617343Coffeemaker · overheatedFA REPORTS AN ODOR OF OVERHEATING NEAR THE COFFEE POT. REPLACED AFT HOT JUG DUE TO LEAKING SEAL. OPS CHECK GOOD REF 25-00-00.SDR DL757060856Coffeemaker · odorFLT ATT COMPLAIN OF BURNING SMELL FROM MID GALLEY COFFEE POTS. TURNED ON COFFEE MAKERS AND OVENS FOR 30 MIN. NO SIGNS OF BURNING SMELL OK FOR SERVICE.SDR 0602286313Controller · malfunctionedGALLEY NR 2 FWD RIGHT OVEN CATCHES ON FIRE AND POPS CIRCUIT BREAKER. MAINTENANCE R & R OVEN CONTROLLER. OPERATION CHECKED GOOD, AIRCRAFT RETURNED TO SERVICE. SDR TSAA0625081Oven · failedDURING THE FLIGHT, THE FLIGHT ATTENDANT REPORTED ONE OF THE AFT OVENS EMITTING A BURNING RUBBER SMELL WHILE IN USE. THE NR 2 OVEN WAS NOT USED FOR THE REMAINDER OF THE FLIGHT AND THE CREW LANDED IN OGG WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE OVEN HEASDR CA061011004Oven · smoke(CAN) BURNING SMELL WAS NOTICED IN THE FWD GALLEY BY THE FLIGHT ATTENDANT WITH AN ASSOCIATE ECAM SMOKE WARNING OF THE FWD LAVATORY. F/A NOTICED SMELL COMING FROM NR 3 OVEN TIMER. OVEN WAS SWITCHED OFF FOR THE REMAINING OF THE FLIGHT WITH NO FURTHER PROBLEM. AISDR CALA0600375Oven · inoperativeSMOKE BEGAN COMING FROM THE NR 1 AFT GALLEY OVEN WHILE EN ROUTE TO LGW. THE OVEN CIRCUIT BREAKER WAS PULLED AND THE SMOKE CEASED. THE FLIGHT CONTINUED TO LGW WHERE IT LANDED SAFELY WITHOUT FURTHER INCIDENT. THE OVEN AND CONTROLLER WERE REMOVED AND REPLACED
Back to JASC 2530