JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR DL76G070229Oven · inoperativeFOUND GALLEY REAR CENTER OVEN INOP, FWD TO MCO AND PLACARD PER MEL 25-20-01H CB PULLED AND COLLARED DUE TO AFT GALLEY OVEN NR 6 CB POPPED WITH REPORT OF VISABLE ELECTRIC FLASH. REPLACED OVEN CKS GOOD REMOVED MCO AND PLAC.Mar 22, 2007 · N173DZ · Boeing 767332SDR NWAA071136314Oven · contaminatedDURING CRUISE, THE FLIGHT ATTENDANTS NOTICED AN ODOR AT GALLEY 2. SMOKE SEEN COMING OUT OF THE OVEN, (NO FIRE), PER F/A INCIDENT REPORT "SPARKLES" OBSERVED AT BOTTOM OF OVEN. 4 HALOGEN FIRE BOTTLES WERE DISCHARGED. CIRCUIT BREAKERS WERE PULLED. NO EMERGENCMar 21, 2007 · N674US · Boeing 747451SDR QXEA200700395Unknown · odorSEA FLIGHT NR 2017, BURNING RUBBER ODOR FROM MAPCO, GALLEY EQUIPMENT INOP. MAINTENANCE PLACED MAPCO ON MEL.Mar 19, 2007 · N355PH · Dhav DHC8202SDR C2XA07CL033Coffeemaker · smokeCMH FLIGHT 2930 THE CREW REPORTED THE COFFEE POT WAS SMOKING WHEN TURNED ON.THE COFFEE POT WAS PLACED ON MEL AND THE AIRCRAFT WAS RELEASED FOR SERVICE. MAINTENANCE INSPECTED AND REPLACED THE NR 2 COFFEE POT BREWER.OPERATIONAL CHECKS WERE GOOD.Mar 18, 2007 · N17928 · Emb EMB145EPSDR DL76G070215Coffeemaker · odorSTRONG ELEC SMELL IN AFT CABIN DURING CLIMB-OUT. INSPECTED A/C DURING VERIFICATION FLT. TURNED ON ALL OVENS/COFFEE MAKERS/AND CHILLERS IN AFT GALLEY. OPENED UP CEILING PANELS IN AFT GALLEY/CABIN. CHECKED DOOR HEATERS DUCTING/OXY/CANISTERS AND FANS. CHECKEMar 18, 2007 · N1612T · Boeing 767332SDR NWAA070993303Oven · smokeDURING CRUISE FLIGHT ATTENDANTS REPORTED SMOKE AT CEILING AREA ABOVE AFT GALLEY, PULLED CIRCUIT BREAKERS AND SMOKE APPEARED TO STOP. DIVERTED TO LGW AND LANDING WAS UNEVENTFUL. TESTED ALL HOT PLATES, COFFEE MAKERS, BUN WARMERS, CHILLERS, OVENS AND FOUND NR 2Mar 11, 2007 · N803NW · Airbus A330323SDR DL764070203Oven · contaminatedOVEN POS 401 SMOKES SO MUCH IT IS UNUSABLE FOUND PLASTIC SHEET ON TOP OF OVEN FAN. REMOVED DEBRIS. NOW OVEN OPERATES GOOD.Mar 11, 2007 · N841MH · Boeing 767432ERSDR CALA0700125Oven · overheatedTHE NR 1 OVEN OVERHEATED AND BECAME VERY HOT WITH SMOKE COMING FROM THE OVEN. THE FLIGHT ATTENDANT PULLED THE OVEN CIRCUIT BREAKER AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. THE NR 1 OVEN WAS REMOVED AND REPLACED IAW IFM 25-36. Mar 8, 2007 · N54711 · Boeing 737724SDR SWAA071255Coffeemaker · faultyF/A REPORTS BURNING SMELL FROM FWD COFFEEMAKER. REMOVED AND REPLACED COFFEEMAKER PER MM.Mar 7, 2007 · N527SW · Boeing 7375H4SDR XXUA200701037Oven · inoperativeOVEN NR 2 AFT INOPERATIVE (CB PULLED AND COLLARED AFTER SEVERE SMOKE) SPILLAGE NOTED. REPLACED OVEN IAW MM 25-31-00, OPS CHECKS NORMAL.Feb 21, 2007 · N401JS · Boeing 7572Q8SDR COMA0760176Rack · dirtyFLIGHT 5008 - EN ROUTE RSW-CMH CREW REPORTED THE PRESENCE OF STRONG ELECTRICAL SMOKE SMELL IN THE COCKPIT, FLIGHT DIVERTED TO MCO. REPLACED THE COFFEEMAKER RACK.Feb 11, 2007 · N629BR · Cndair CL6002B19SDR AWXA200700197Oven · fireOVEN FIRE, F/A REPORTED FIRE IN OVEN NR 4, CARDBOARD FROM FOOD TRAY CAUGHT FIRE. THE F/A EXTINGUISHED WITH PORTABLE HALON FIRE EXTINGUISHER. MX REMOVED AND REPLACED AFT GALLEY HALON EXTINGUISHER AND PLACED THE OVEN ON MEL.Feb 11, 2007 · N678AW · Airbus A320232SDR SWAA070605Coffeemaker · faultyAFT COFFEEMAKER HAD BURNING SMELL DURING FLIGHT, OPENED C/B SMELL DISSIPATED. REMOVED AND REPLACED COFFEEMAKER PER MM.Feb 5, 2007 · N411WN · Boeing 7377H4SDR AALA20070270Oven · inoperativeORD INFLIGHT FERRY FLIGHT T1173/03FEB - ON SHORT FINAL, CREW REPORTED ELECTRICAL BURNING SMELL AND SMOKE IN FIRST CLASS GALLEY. ALL OVENS WERE OFF. TURNED GALLEY POWER AND RECIRCULATION FANS OFF WITH NO HELP. LANDED ORD WITHOUT INCIDENT. REPLACED FIRST CLAFeb 3, 2007 · N419AA · Doug DC982SDR SWIA200717784Coffeemaker · odorFLIGHT ATTENDANT REPORTED OVERHEATED ODOR COMING OUT OF HOT JUGS. SWITCH WAS TURNED OFF AND ODOR DISAPPEARED. REPLACED HOT JUG WITH SERVICEABLE UNIT IAW 25-60-00. OPERATIONAL CHECKS GOOD.Jan 30, 2007 · N215SW · Emb EMB120ERSDR 0700373269Coffeemaker · odorFLIGHT ATTENDANT REPORTED LARGE WATER MESS IN AFT GALLEY, THEN ODOR OF ELECTRICAL FUMES AND SMOKE. FLIGHT CREW REMOVED POWER FROM GALLEY, OBSERVATION REVEALED THAT ODOR STILL PERSISTED, NO SMOKE. AN EMERGENCY WAS DECLARED AND THE FLIGHT DIVERTED INTO DTW. AJan 23, 2007 · N369NW · Airbus A320212SDR AALA20070144Coffeemaker · inoperativeLHR INLIGHT - SMOKE CREW REST MAIN MESSAGE ILLIMINATED AND FLIGHT ATTENDANT ADVISED A STRONG ODOR AND HIGH TEMPERATURE WAS IN THE AREA OF COFFEEMAKERS 10, 11, 12, AND 13. COFFEEMAKERS WERE IMMEDIATELY SHUT OFF AND THE ODOR AND HEAT SUBSIDED. LANDED LHR WITHOJan 21, 2007 · N792AN · Boeing 777223SDR 2007UALA00103Oven · smokeOVEN 105R11 WAS SMOKING IN FLT SHUT OFF POWER AND SMOKE STOPPED. REPLACED OVEN. OPS CHECKED GOOD.Jan 15, 2007 · N463UA · Airbus A320232SDR AALA20070063Oven · dirtySJU INFLIGHT T1044/11JAN AUA TO BOS - FIRST CLASS GALLEY OVEN BEGAN SMOKING. SMELLED LIKE ORGANIC MATERIAL. OVEN TEMPERATURE WAS SET AT 175 AND THE OVERHEAT LIGHT DID NOT COME ON. THE NUMBER ONE AND NUMBER TWO FIRST CLASS OVENS WERE TURNED OFF AND THE CIRCUJan 11, 2007 · N199AN · Boeing 757223SDR WRLA2007003Oven · smokeMID GALLEY OVEN NR 2 STOPPED WORKING, C/B PULLED. ELECTRICAL SMOKE WAS SENSED ON LEFT SIDE OF VENT, NO SMOKE WAS EVIDENT ALTHOUGH SMELL WAS NOTICEABLE. OPS CHECKED MID OVENS, NO SIGN OF ELECTRICAL SMOKE OR ODOR. COOKED WITH MID GALLEY OVENS FOR MEAL SERVICEJan 8, 2007 · N801DE · Doug MD11SDR ASAA0741357Oven · odorFWD GALLEY OVEN CAUSES STRONG ELEC ODOR AND TRIPS GALLEY PWR. DEFERRED OVENS INOP COLLARDED CB'S PER MEL.Jan 7, 2007 · N764AS · Boeing 7374Q8SDR AALA20070032Coffeemaker · sparksLHR INFLIGHT T116/06JAN - DURING CLIMB FROM JFK FLIGHT ATTENDANT REPORTED SPARKING UNDER NUMBER 17 COFFEEMAKER IN AFT GALLEY WHEN TURNED ON. PULLED CIRCUIT BREAKER AS PRECAUTION. NO FAULTS FOUND ON AIRCRAFT WIRING TO COFFEEMAKER NUMBER 17 IN AFT GALLEY. REJan 6, 2007 · N762AN · Boeing 777223SDR 136001042007Heater · odorSMOKE AND ODOR EMTTED FROM GALLEY HOT CUP.Jan 4, 2007 · N460QS · Gulstm GIVSDR TSAA0725002Oven · smokeFLIGHT 476 OGG-SAN, DURING CRUISE FLIGHT, A FLIGHT ATTENDANT NOTICED SMOKE FROM THE RIGHT OUTBOARD OVEN IN THE AFT GALLEY. THE FLIGHT ATTENDANTS TURNED OFF THE OVEN AND THE SMOKE DISSIPATED. THE FLIGHT CONTINUED TO SAN WITHOUT FURTHER INCIDENT. MAINTENANCE Jan 2, 2007 · N741AL · Boeing 73776NSDR AALA20070236Coffeemaker · malfunctionedLAX INFLIGHT T170/01FEB - CAPTAIN REPORTED SEEING SMOKE AROUND NUMBER 10 AND 11 COFFEE MAKERS AND SMELL OF BURNING INSULATION. CIRCUIT BREAKERS POPPED. FOUND THE NUMBER 11 COFFEE MAKER BLEW TWO HEATING ELEMENTS OUT OF WATER TANK SPRAYING WHITE POWDER ALL BEHJan 1, 2007 · N798AN · Boeing 777223SDR SWAA065078Coffeemaker · malfunctionedFLIGHT ATTENDANT REPORTED SMOKE AND SPARKS FROM AFT COFFEEMAKER. INSPECTED AFT GALLEY AREA, NO EVIDENCE OF SMOKE, ARCHING OR SPARKS. REMOVED AND REPLACED COFFEEMAKERS PER MM AS PRECAUTION.Dec 24, 2006 · N493WN · Boeing 7377H4SDR TSAA0625120Oven · odorFLT 442 HNL-OAK: DURING FLIGHT, THE CREW NOTED A BURNING ODOR COMING FROM THE NR 1 OVEN IN THE AFT GALLEY. THE CREW TURNED OFF OVEN AND THE ODOR DISSIPATED SHORTLY AFTER. AIRCRAFT LANDED IN OAK WITHOUT FURTHER INCIDENT. MAINTENANCE REPLACED THE AFT GALLEY NDec 19, 2006 · N751AL · Boeing 7377Q8SDR 0602779884Oven · smokeWHEN FLIGHT ATTENDANT ATTEMPTED TO UTILIZE THE OVEN A THICK WHITE SMOKE DEVELOPED FROM THE ELECTRICAL WIRE CONNECTION AREA AT BACK WALL. SMOKE SMELLED OF ELECTRICAL BURNING AND DID NOT EMANATE FROM BURNING SPILLAGE INSIDE THE OVEN. AN INOPERATIVE OVEN FAN WADec 18, 2006 · N677MC · Doug DC951SDR 2006UALA02379Coffeemaker · odorELECTRICAL ODOR NOTICED IN THE AFT GALLEY. ODOR MORE PRONOUNCED AROUND DOOR 2L. NO ELECTRICAL ODOR DETECTED. NOTICE GLYCOL ODOR. ALSO, BURNED COFFEE ODOR COMING FROM COFFEE MAKER 41. RAN PACKS FULL HOT AND COFFEE MAKER HOT PLATES. DETERMINED ODOR IS COMIDec 16, 2006 · N427UA · Airbus A320232SDR CALA0600537Oven · overheatedTHE FORWARD GALLEY 103 OVEN WAS UNUSUALLY HOT AND HAD AN ELECTRICAL ODOR PRIOR TO STARTING IT. THE CIRCUIT BREAKER WAS PULLED. THE OVEN WAS REMOVED AND REPLACED, OPERATIONAL CHECKS WERE GOOD.Dec 9, 2006 · N14324 · Boeing 7373T0SDR DL764061009Oven · smokeFLIGHT ATTENDANT REPORTED SMOKE AND RED GLOW ON TOP OF OVEN NUMBER 1 ON POWER-UP. REMOVED OVEN AND INSPECTED WIRES. ALL OK, REMOVED AND TIED BACK CONNECTOR, PULLED AND COLLARED OVEN C/B AND DEFERRED PER MEL. REPLACED OVEN MCO/PLAC REMOVED.Dec 6, 2006 · N841MH · Boeing 767432ERSDR CALA0600536Oven · malfunctionedTHE FIRST CLASS GALLEY OVEN 205 BEGAN TO SMOKE. CIRCUIT BREAKERS WERE PULLED AND THE SMOKE DISSIPATED. THE OVEN WAS REMOVED AND REPLACED AND OPERATIONAL CHECKS WERE GOOD WITH NO DEFECTS NOTED.Nov 25, 2006 · N30401 · Boeing 737924SDR XXUA200611034Oven · smokeOVEN NR 6 WAS SMOKING WHEN IN USE. SUSPENDED COOKING. INSPECTED OVEN AND FOUND BURNT PLASTIC IN OVEN FAN GRILL. CLEANED INTERIOR OF FAN AND OPERATIONAL CHECKS NORMAL. OK FOR CONTINUED SERVICE.Nov 23, 2006 · N403JS · Boeing 7572Q8SDR A6WA200640391Coffeemaker · odorCOFFEEMAKER HAS BURNING SMELL WHEN BREWING. NO SMELL WHEN OFF. PULLED AND COLLARED COFFEEMAKER CIRCUIT BREAKER. PLACARDED AND PLACED ON MEL. REMOVED AND REPLACED COFFEEMAKER IAW AMM. OPS CHECK NORMAL. REMOVED PLACARD AND MEL. (K)Nov 22, 2006 · N2530 · Cndair CL6002B19SDR AALA20061084Coffeemaker · defectiveLGA INFLIGHT T386/19NOV - FLIGHT ATTENDANT REPORTED HEARING TWO POPS AND SAW A SMALL AMOUNT OF WHITE SMOKE COMING FROM THE AFT GALLEY NUMBER FOUR COFFEE MAKER. FOUND NUMBER FOUR COFFEE MAKER HEATER ELEMENT CONNECTORS DISCONNECTED WITH EVIDENCE OF ARCHING. RENov 19, 2006 · N7534A · Doug DC982SDR QXEA200603139Door · damagedC4 PDX - HINGE MOUNT EXTENSION FOR GALLEY TRASH CAN ACCESS DOOR HAS A SCREW BROKEN OFF IN THE BOTTOM MOUNT HOLE. REPAIRED IAW DRILLED OUT BROKEN SCREW AND REMOVED THE DAMAGED INSERT AND INSTALLED A NEW INSERT IN ITS PLACE.Nov 13, 2006 · N361PH · Dhav DHC8202SDR QXEA200602960Coffeemaker · burnedSEA FLIGHT NR 2392: FLIGHT ATTENDANT REPORTS LT COFFEMAKER IS MAKING SPARKING ELECTRICAL SOUNDS AND BOILING THE WATER INSIDE. MAINTENANCE REMOVED AND REPLACED LT COFFEMAKER WITH NO OTHER DEFECTS NOTED. AIRCRAFT RETURNED TO SERVICE.Nov 12, 2006 · N412QX · Bombdr DHC8402SDR AWXA200601894Oven · malfunctionedLAS - BS - FLIGHT ATTENDANT REPORTED BURNING ODOR NR 1 OVEN NO VISIBLE RESIDUE. MAINTENANCE INSERTED DIFFERENT OVEN IN NR 1 OVEN RACK, OPS CK GOOD.Nov 8, 2006 · N627AW · Airbus A320231SDR SIMA200630501Coffeemaker · dirtyRUBBER BURNING SMELL BY SEAT 1B. FOUND SMELL TO BE COMING FROM BURNED COFFEE ON COFFEE HOT PLATE. REMOVED BURNED COFFEE FROM HOT PLATE. OPERATIONAL CHECK GOOD. RETURNED AIRCRAFT TO SERVICE. (M)Oct 29, 2006 · N510AE · Cndair CL6002C10SDR DL76L060901Oven · burnedMARKS AROUND OVEN AFT GALLEY TOP RIGHT F/O SIDE. FWD TO MCO AND PLACARD PER MEL M25-20-01H DEFECT, CONFIRMED-SCORCH MARKS PRESENT AT DIVIDER WALL-SEAL. INSPECTED SATIS, HOWEVER, SEAL MATING SURFACE MISSING IN LOWER CORNER SECTION. NR 3 OVEN CONSIDERED AS INOct 29, 2006 · N184DN · Boeing 767332SDR DL777060900Oven · inoperativeOVEN 1 CIRCUIT BREAKER PULLED IN ASSOC WITH BURNING ELEC SMELL. ACTIVATED OVEN FWD TO MCO AND PLAC PER MEL 25-20-01G. REPLACED OVEN AND OPERATED OPS CKS OK MCO AND PLACARD REMOVED.Oct 29, 2006 · N867DA · Boeing 777232SDR DL75A060887Coffeemaker · failedPOP WITH SMOKE OUT OF COFFEE MAKER, RETURNING TO GATE TO HAVE IT CHECKED OUT. NO HISTORY. MAINTENANCE REMOVED AND INSPECTED COFFEE MAKER. CIRCUIT BREAKER TO REMAIN PULLED AND FWD COFFEE MAKER TO MCO/PLAC. REPLACED DC CONVERTER, CKS GOOD.Oct 26, 2006 · N752AT · Boeing 757212SDR AWXA200601830Coffeemaker · burnedLAS - BURNING SMELL - FWD COFFEE MAKER INOP, BURNING SMELL UNTIL C/B PULLED. REMOVED AND REPLACED NR 1 COFFEE MAKER PER TASK CARD R1D25303.Oct 24, 2006 · N668AW · Airbus A320232SDR ASAA0681125Coffeemaker · defectiveAFT GALLEY COFFEEMAKER BEGAN TO SMOKE DURING FLIGHT. PERFORMED AIR TURNBACK. REMOVED DEFECTIVE COFFEEMAKER.Oct 22, 2006 · N979AS · Doug DC983SDR SWIA200617343Coffeemaker · overheatedFA REPORTS AN ODOR OF OVERHEATING NEAR THE COFFEE POT. REPLACED AFT HOT JUG DUE TO LEAKING SEAL. OPS CHECK GOOD REF 25-00-00.Oct 19, 2006 · N580SW · Emb EMB120ERSDR DL757060856Coffeemaker · odorFLT ATT COMPLAIN OF BURNING SMELL FROM MID GALLEY COFFEE POTS. TURNED ON COFFEE MAKERS AND OVENS FOR 30 MIN. NO SIGNS OF BURNING SMELL OK FOR SERVICE.Oct 16, 2006 · N674DL · Boeing 757232SDR 0602286313Controller · malfunctionedGALLEY NR 2 FWD RIGHT OVEN CATCHES ON FIRE AND POPS CIRCUIT BREAKER. MAINTENANCE R & R OVEN CONTROLLER. OPERATION CHECKED GOOD, AIRCRAFT RETURNED TO SERVICE.   Oct 14, 2006 · N673US · Boeing 747451SDR TSAA0625081Oven · failedDURING THE FLIGHT, THE FLIGHT ATTENDANT REPORTED ONE OF THE AFT OVENS EMITTING A BURNING RUBBER SMELL WHILE IN USE. THE NR 2 OVEN WAS NOT USED FOR THE REMAINDER OF THE FLIGHT AND THE CREW LANDED IN OGG WITHOUT FURTHER INCIDENT. MAINTENANCE FOUND THE OVEN HEAOct 4, 2006 · N740AL · Boeing 73776NSDR CA061011004Oven · smoke(CAN) BURNING SMELL WAS NOTICED IN THE FWD GALLEY BY THE FLIGHT ATTENDANT WITH AN ASSOCIATE ECAM SMOKE WARNING OF THE FWD LAVATORY. F/A NOTICED SMELL COMING FROM NR 3 OVEN TIMER. OVEN WAS SWITCHED OFF FOR THE REMAINING OF THE FLIGHT WITH NO FURTHER PROBLEM. AIOct 1, 2006 · Airbus A330243SDR CALA0600375Oven · inoperativeSMOKE BEGAN COMING FROM THE NR 1 AFT GALLEY OVEN WHILE EN ROUTE TO LGW. THE OVEN CIRCUIT BREAKER WAS PULLED AND THE SMOKE CEASED. THE FLIGHT CONTINUED TO LGW WHERE IT LANDED SAFELY WITHOUT FURTHER INCIDENT. THE OVEN AND CONTROLLER WERE REMOVED AND REPLACED Oct 1, 2006 · N17139 · Boeing 757224
Back to JASC 2530