SDR HNAA0600114Coffeemaker · overheatedBURNING ODOR IN CABIN AND COCKPIT. FOUND SEAL ON HOT JUG BURNING DUE TO NO LIQUID INSIDE REMOVED AND REPLACED HOT JUG.SDR DL75A060750Coffeemaker · burnedELECTRICAL FUMES REAR GALLEY AREA. PULLED ALL REAR GALLEY C/B`S, FUMES LESS. SUSPECT REAR GALLEY CAPTS SIDE COFFEEMAKER. RAN BREW CYCLE ON BOTH AFT GALLEY COFFEEMAKERS, CAPTS SIDE SMELLED STRONGER. REPLACED COFFEEMAKER NR 2 AFT GALLEY. RERAN BREW CYCLES NSDR DL757060740Coffeemaker · burnedBURNING SMELL IN AFT GALLEY, DISCOVERED MELTED PLASTIC ON HOT PLATE OF COFFEE MAKER. NEEDS TO BE CLEANED OUT. REPLACED COFFEE MAKER. OP CKS OK.SDR CA061110002Motor · burned(CAN) A OPERATOR MADE A UNSCHEDULED LANDING DUE TO HEAVY SMELL COMING FROM AFT GALLEY. INVESTIGATION SHOWED THAT THE BLOWER MOTOR OF ONE GALLEY OVEN SHOWS BURN DAMAGE. OVEN REMOVED AND SENT FOR REPAIR. (TC NR 20061110002)SDR AALA20060677Coffeemaker · malfunctionedCOFFEEMAKER AT THREE RIGHT POSITION MADE A LOUD BANG AND PUT OUT WHITE SMOKE. POWER WAS SECURED AND ALL CIRCUIT BREAKERS PULLED. UNIT HAD NO FURTHER PROBLEMS. REPLACED NUMBER 11 COFFEEMAKER AFTER REMOVING AND CHECKING CARRIAGE FITTINGS AND ELECTRICAL CONNECSDR AALA20060653Oven · dirtyCREW COMPLAINED OF SMOKE COMING FROM FORWARD GALLEY NUMBER TWO OVEN. FOUND OVEN COVERED IN BURNT FOOD. CLEANED OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2006UALA01702Coffeemaker · smokeSMOKE IN AFT GALLEY. AFT GALLEY HAD HEAVY SMOKE UNTIL GALLEY POWER TURNED OFF. CREW OBSERVED THAT SMOKE CAME FROM RIGHT SIDE WALL ABOVE COFFEEMAKER M41 AND M42. ONCE ON GROUND, AND ALL GALLEY EQUIPMENT POWER SWITCHED ON, NO SMOKE FROM THIS AREA. HOWEVER, HSDR QXEA200602315Coffeemaker · malfunctionedLAX FLIGHT NR 2424, ELECTRICAL SMELL FROM GALLEY AREA. DETERMINED TO BE FROM MAPCOS. DEACTIVATED. MAINTENANCE CHECKED THE WIRING AND VOLTAGES, CHECKS GOOD. REPLACED BOTH MAPCOS. AIRCRAFT RETURNED TO SERVICE.SDR 0601875532Oven · smokeTHE FIRST CLASS (G-1) OVEN BEGAN TO RELEASE SMOKE AFTER BEING TURNED ON. AN ELECTRICAL SMELL WAS NOTICED IN THE COCKPIT AND BY PASSENGERS. THE SMELL DISSIPATED WHEN THE OVEN WAS TURNED OFF. MAINTENANCE INSPECTED THE AREA AND FOUND NO EVIDENCE OF FIRE OR SMOKE SDR 2006UALA01676Coffeemaker · faultyFLIGHT DIVERTED TO CID DUE TO ELECTRIC BURNING SMELL IN CABIN. FOUND BLACK CARBON RESIDUE UNDER COFFEEMAKER. REPLACED COFFEEMAKER.SDR UPS06M47749Coffeemaker · overheatedHOT CUP OVERHEAT DUE TO DEFAULT OF TIMER AND SUBSEQUENT MELT-DOWN OF 3 PIN CONNECTIONS W/ACRID FUMES IN COCKPIT AND EXCESSIVE HEAT AROUND OVEN AREA. REPLACED HOT CUP JUG AND PERFORMED OPS TEST OF HOT CUP TIMER AND FOUND NORMAL IAW 25-32-14-2. TIMER OPERATION SDR DL764060664Oven · faultyFWD GALLEY NR 2 OVEN SPARKS. C/BS PULLED FWD TO MCO PER MEL 25-20-01H PLACARD INSTALLED. REPLACED OVEN MCO AND PLACARD REMOVED.SDR SIMA200623301Module · failedDFW - FLT 3599 - AFTER TAKEOFF FA AND PAX REPORTED SMELLING SOMETHING BURNING. AIRCRAFT RETURNED AFTER COMPLETING CHECKLIST, SMELL RETURNED ON GROUND, POSSIBLE OVERWEIGHT LANDING. RAI AFT GALLEY ELECTRICAL MODULE ASSY IAW C/D AEROSPACE CMM 25-31-98, OPS CHECSDR QXEA200602066Galley · odiferousSEA FLIGHT NR 2054 ON DESCENT, AIRCRAFT SMELLS LIKE A DIRTY LAV. LAV FLUID HAS BEEN EXCHANGED TWICE, WARDROBE CLOSET HAS BEEN CLEANED. AIRCRAFT STILL SMELLS LIKE DIRTY LAV. REQUESTING BELLY DRAIN BR OPEN WS FOR ANY OVER FLOW FLUID TO ESCAPE. MAINTENANCE FOUNSDR DXTA200601552Oven · odorDURING FLIGHT, THE 115A INVERTER CB POPPED AS MICROWAVE WAS BEING USED. CREW NOTICED ELECTRICAL SMOKE/BURNED SMELL IN THE CABIN. OPERATED MICROWAVE OVEN FOR 15 MINUTES WITH NO DEFECTS NOTED. REPLACED MICROWAVE IAW F-2000 M/M 25-20-00. OPERATIONAL CHECK GOOSDR DL76L060652Oven · contaminatedSLIGHT PLASTIC ODOR DESCENDING THRU 6000 IN COCKPIT FWD GALLEY AND BUSINESS CLASS. LASTED JUST A FEW 3 MINUTES. NO ODOR FOUND, SUSPECT PLASTIC FROM CONTENTS IN OVEN, CLEANED OVENS.SDR WRLA2006038Switch · inoperativeRCH964/10 EDDR/OKBK SH0RTLY AFTER ARRIVAL NOTICED SMOKE SMELL IN FORWARD GALLEY. PULLED C/B'S AND DEACTIVATED NR 3 OVEN. FOUND NR 3 OVEN SW VERY HOT, WITH AIRCRAFT POWER ON CB POPPED. ISOLATED PROBLEM TO THE SWITCH. PULLED CB'S, PLACED ITEM ON DMI AND INSTALLSDR DL76S060633Coffeemaker · odorFLT ATTENDANT SMELLED BURNT PLASTIC IN AFT GALLEY FROM A CEILING PANEL IN PROX OF COFFEEMAKERS. NO HEAT FELT ON PANEL, F/A TURNED OFF ALL COFFEEMAKERS AND PULLED A FEW C/BS AND SMELL DISSIPATED. OPERATED ALL APPLIANCES AND LIGHTS. NO IRREG NOTED.SDR 2006UALA01492Odor · detectedBURNING ODOR IN AFT GALLEY WHEN COFFEEMAKERS TURNED ON. REMOVED AND INSPECTED WIRING AND RECEPTACLES BEHIND CABIN MODULES. CM'S HAD ELEC SMELL WHEN REMOVED. NO PREVIOUS HISTORY FOUND. REPLACED COFFEEMAKER.SDR 2006UALA01465Chiller · failedBURNING ELECTRICAL SMELL COMING FROM ECONOMY GALLEY AFTER CHILLER C51 FAILED. PERFORMED DIAGNOSTIC, OPERATING CHILLER. OPERATED FOR 10 MINUTES THEN STOPPED RUNNING BUT RUN LT STILL ON. REPLACED CHILLER PER MM 25-33-93 PG 401 AND OPS NORMAL WITH NO BURNING SSDR AALA20060471Oven · dirtyCDG - FIRST CLASS OVEN NUMBER ONE HAD FOOD SPILL CAUSING SMOKE IN GALLEY. CLEANED OVEN NUMBER ONE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR HALA0600493Oven · malfunctionedDURING CLIMBOUT OF PHX OVEN LOCATED IN FWD GALLEY FACING LEFT SIDE OF FUSELAGE FURTHEST AFT STARTED EMITTING SMOKE AND SMELL OF OVERHEATED INSULATION ALL STOPPED WHEN POWER WAS REMOVED. WIRES AND CONNECTION INSPECTED AND CHECKED BY ELECTRIC SHOP FOUND OK. RESDR QXEA200601758Coffeemaker · odorSMF FLIGHT NR 2302 - BURNING ELECTRICAL ODOR IN GALLEY. SEEMS TO BE COMING FROM MAPCOS. MAINTENANCE REPLACED BOTH HOT JUGS. NO FURTHER SMELLS NOTED. AIRCRAFT RETURNED TO SERVICE.SDR AWXA200601187Sink · odor1ST FA REPORTS STRONG FOOD ODOR COMING FROM FWD GALLEY DRAIN. MAINTENANCE CLEARED THE DRAIN IN THE FORWARD GALLEY SINK, NO MORE ODOR.SDR 7706Light · malfunctionedON APPROACH FLIGHT CREW NOTICED AN ACRID SMELL, THE AIRCRAFT LANDED AND EXITED THE RUNWAY WITHOUT INCIDENT AT WHICH TIME SMOKE WAS SEEN IN THE AFT GALLEY AND THE OVER COUNTER LIGHT LENS HAD OBSERVABLE FLAMES. THE PILOT REMOVED ELECTRICAL POWER FROM THE GALLEYSDR DLM88060544Oven · smokeCREW REPORT FROM F/A THAT HAD LIGHT HAZY SMOKE IN THE FWD AND MID CABIN BUT HEAVIEST IN FWD GALLEY AREA. BURNING NON-ELECTRICAL SMELL. FLT CREW COULD SMELL IN COCKPIT BUT NO VISIBLE SMOKE. C/W OP 5088. FOUND FC OVEN OVERHEATING AND CAUSING BURNING SMELL INSDR CALA0600235Coffeemaker · damagedTHE FLIGHT ATTENDANT HEARD A LOUD POP AND SMELLED AN ELECTRICAL BURNING ODOR IN GALLEY NR 5 WHILE EN ROUTE TO HNL. THE GALLEY CIRCUIT BREAKERS WERE PULLED AND THE ODOR CEASED. THE AIRCRAFT LANDED AT HNL WITHOUT INCIDENT. MAINTENANCE FOUND COFFEEMAKER NR 509SDR CALA0600233Oven · inoperativeTHE FLIGHT ATTENDANT REPORTED A BURNING ODOR COMING FROM THE AFT GALLEY WHILE EN ROUTE TO SEA. THERE WAS NO SMOKE OBSERVED. THE OVEN CIRCUIT BREAKERS WERE PULLED AND THE ODOR DIMINISHED. THE AIRCRAFT LANDED AT SEA WITHOUT INCIDENT. MAINTENANCE ISOLATED THESDR AALA20060421Oven · dirtyDFW - INFLIGHT FLIGHT ATTENDANT REPORTED SMOKE COMING FROM FORWARD GALLEY OVEN. RETURNED TO DFW AND LANDED OVERWEIGHT WITHOUT INCIDENT. ACCOMPLISHED OVERWEIGHT INSPECTION. PLACARDED FIRST CLASS OVEN AND PULLED AND COLLARED CIRCUIT BREAKER. CLEANED HEATING SDR CNMA20060015Oven · odorWHEN FORWARD OVENS 307 & 308 WHERE TURNED ON A STRONG ODOR CAME FROM THEM. WHEN TURNED OFF ODOR DISSIPATED. CLEANED TRAYS BOTH OVENS 307 & 308, OPS CHECK, NO ODOR NOTED, GOOD FOR SERVICE. OMNI AIR IS CURRENTLY ADDING AN INTERVAL FOR CLEANING OVENS AND OVEN SDR AWXA200600996Oven · smokeSNA - SMOKE - FLT 652 - DURING CRUISE REPORTED THE NR 1 AFT OVEN WAS SMOKING, REPORTEDLY DUE TO CRUMBS INSIDE OVEN. FLIGHT ATTENDANT DISCHARGED HALON FIRE EXTINGUISHER, PULLED AND COLLARED CIRCUIT BREAKER. NR 1 AFT OVEN WAS PLACED ON MEL. PHX - MAINTENANCE SDR MASA200601593Coffeemaker · odorASH 6383 DSM - BURNING SMELL FROM COFFEEMAKER. MAINTENANCE REMOVED AND REPLACED COFFEEMAKERS.SDR AALA20060377Oven · malfunctionedINFLIGHT EXPERIENCED ELECTRICAL ODOR AND HAZE COMING FROM COMPARTMENT 547 BUSINESS CLASS GALLEY WARMING OVEN. LANDED WITHOUT INCIDENT. FOUND NO EVIDENCE OF DAMAGE TO WIRING OR SMOKE DAMAGE. PULLED AND COLLARED CIRCUIT BREAKER FOR WARMING OVEN. REPLACED BUSSDR CALA0600220Coffeemaker · malfunctionedAN ODOR OF BURNING INSULATION WAS EVIDENT WHEN BREWING COFFEE IN THE AFT GALLEY WHILE EN ROUTE TO IAH. THE COFFEEMAKERS WERE TURNED OFF AND CIRCUIT BREAKERS WERE PULLED. THE AIRCRAFT ARRIVED AT IAH WITHOUT FURTHER PROBLEM. BOTH AFT GALLEY COFFEEMAKERS WERE SDR CALA0600193Oven · malfunctionedTHE FLIGHT ATTENDANT REPORTED SMOKE COMING OUT OF THE TOP OF THE AFT GALLEY LEFT NR 1 OVEN DURING CLIMBOUT. BOTH UTILITY BUSSES WERE TURNED OFF AND THE AFT GALLEY OVEN CIRCUIT BREAKERS WERE PULLED. THE SMOKE DISSIPATED QUICKLY AND THE FLIGHT WAS CONTINUED WSDR DL777060414Odor · detectedAFTER LANDING F/A SMELLED ELECTRICAL FUMES ON CAPTS SIDE OF AFT GALLEY. SMELL WAS GONE BY END OF DEPLANING INSP AFT GALLEY AREA. NO EVIDENCE OF SMOKE OR ELECT SMELL.SDR DXTA200601395Water Heater · failedELECTRIC BURNING SMELL IS PRESENT AT THE INTERSECTION OF THE GALLEY AND THE CABIN. DETERMINED ELECTRICAL BURN SMELL DUE TO WATER HEATER FAILURE. WATER HEATER ISOLATED AND DEFERRED IAW MEL 25-7 AND SUPPLEMENTAL MAINT PROCEDURES.SDR C2XA06IA072Coffeemaker · inoperativeIAH - FLIGHT 2701, THE CREW REPORTED A BURNING SMELL COMING FROM THE RIGHT COFFEEPOT. MAINTENANCE INSPECTED THE AIRCRAFT, AND PLACED THE COFFEEMAKER ON MEL 25-60-02 CONTROL NUMBER 100049, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. ON 05/12/06, IAH SDR AWXA200600793Oven · odorPHX - SMOKE - NR 7081301 - CREW REPORTED THAT THE NR 2 OVEN SMOKED, FILLED GALLEY AREA AND SMELLED BAD. MAINTENANCE DEFERRED THE NR 2 FWD OVEN. MAINTENANCE REMOVED AND REPLACED THE NR 2 OVEN IAW AMM 25-35-11. OPERATIONAL CHECKS WERE GOOD.SDR DXTA200601368Coffeemaker · overheatedDURING DESCENT, STARTED GETTING BURNING ELECTRIC SMELL, SMELL SEEMS TO COME FROM BEHIND TOP DRAWER BELOW COFFEE POTS. CABIN POWER WAS TURNED OFF AND SMELL DISAPPEARED COFFEE POT WAS EXTREMELY HOT. REMOVED COFFEE POT. ITEM IS UNDER INVESTIGATION.SDR DL76L060327Coffeemaker · looseACRID SMELLING ODOR WAS PRESENT IN AFT GALLEY. REMOVED LT COFFEE MAKER AT GALLEY 413 LT SIDE AND FN D NBR 4 AND FWD COFFEE MAKER W/HOTPLATE RESISTANCE ASSY LOOSE AND OVER DRAIN COLLECTOR. CLEANED AREA. DEFECTIVE COFFEE MAKER REPLACED ETOPS CATEGORY (F): ANY OSDR SWAA061285Coffeemaker · faultyBURNING SMELL IN FWD GALLEY. REMOVED AND REPLACED FWD COFFEEMAKER PER MM.SDR AWXA200600663Coffeemaker · odorLAS - BURNING SMELL - CREW REPORTED AN ACRID SMELL COMING FROM THE FORWARD GALLEY. THE NR 1 COFFEE MAKER WOULD NOT WORK. THE NR 1 COFFEEMAKER WAS REMOVED AND REPLACED IAW AMERICA WEST AIRLINES TASK CARD R1D25303.SDR DXTA200601341Switch · shortedTHE POWER CIRCUIT BREAKER IN THE LAV CIRCUIT BREAKER PANEL(GALLEY) POPS WHENEVER THE LIGHTS CIRCUIT BREAKER IN THAT PANEL IS PUSHED IN AND MASTER GALLEY POWER IS ON. TROUBLESHOT ALL OTHER BREAKERS AND DETERMINED THAT ONLY THE LAV LIGHTS CIRCUIT BREAKER WILL TRSDR 2006UALA00649Oven · overheatedFLIGHT ATTENDANT REPORTED ODOR OF SMOKE IN FWD GALLEY AREA. FLIGHT ATTENDANT REPORTS OVEN OVERHEATING AND CAUSING GALLEY CEILING TO GET VERY HOT. OVEN WAS REPLACED AND SUBSEQUENT OPERATIONAL CHECK WAS NORMAL. OSV REPAIR FACILITY REPORTS NO FINDINGS THAT WSDR DL777060227Oven · malfunctionedLOUD POPPING SOUNDS NOTED BY FLT ATTN IN FWD GALLEY FOLLOWED BY LITE SMOKE AND SPARKS FROM OVEN 103. OVEN TURNED OFF AND OVEN CIRCUIT BREAKERS PULLED. FLT CREW ADVISE SMOKE AND SPARKS COMING FROM OVEN FRONT VENT. REMOVED OVEN AND INSP ELEC CONNECTOR AND WIRSDR AALA20060191Connector · inoperativeLBB - SMOKE COMING FROM ABOVE FIRST CLASS GALLEY. ALSO WATER COMING FROM FIRST CLASS GALLEY AND INTO COCKPIT ON THE FIRST OFFICER SIDE. LANDED LBB WITHOUT INCIDENT. FOUND POTABLE WATER CONNECTOR LOOSE AND LEAKING ON NUMBER ONE AND NUMBER TWO COFFEEMAKERS. SDR SB06027Warmer · dirtyEN ROUTE FROM PIT TO TPA, 90 NAUTICAL MILES NORTH OF CLT, ONE OF THE FLIGHT ATTENDANTS NOTICED A BURNING SMELL IN THE AFT GALLEY. A SECOND FLIGHT ATTENDANT CONFIRMED THE SMELL WAS GETTING WORSE. GALLEY POWER WAS TURNED OFF AND SMELL SUBSIDED. CREW ELECTED TSDR SWAA060623Coffeemaker · faultyDIVERSION/DECLARED EMERGENCY. SMOKE IN CABIN. FOUND FWD COFFEEMAKER EXTREMELY HOT & SMOKING. REMOVED & REPLACED COFFEEMAKER PER MM.SDR MZZA0600002Oven · inoperativeAN ELECTRICAL ODOR CAME FROM THE AFT GALLEY NR 1 OVEN AND THE CIRCUIT BREAKER POPPED WHILE AT CRUISE PORTION OF FLIGHT. THE FLIGHT WAS RETURNED TO GUM WHERE IT LANDED WITHOUT INCIDENT. THE AFT GALLEY NR 1 OVEN AND CONTROLLER WAS REPLACED. A FUNCTIONAL CHECK WA
Back to JASC 2530