JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR BB06014Coffeemaker · failedFLIGHT 634, LAS-PHL - DURING CRUISE, CREW NOTICED AN ELECTRICAL SMELL COMING FROM THE AFT COFFEE MAKERS. DIVERTED TO IND, WHERE MAINTENANCE PLACED BOTH AFT COFFEE MAKERS ON MEL. BOTH COFFEE MAKERS WERE REPLACED IN PHL ON 02/18/06. NO FURTHER DIFFICULTIES.Feb 17, 2006 · N625VJ · Boeing 757225SDR DL76S060113Chiller · odorELEC SMELL FROM AFT GALLEY AREA. FOUND SMELL FROM AFT GALLEY CHILLERS. UNABLE TO DUPLICATE.Feb 10, 2006 · N138DL · Boeing 767332SDR 2006UALA00149Oven · contaminatedOVEN 011 IN F-C GALLEY - LOTS OF SMOKE. SMOKE WAS CAUSED BY FOOD/DEBRIS ON HEATING ELEMENTS. OVEN HEATING ELEMENTS WERE CLEANED AND A FOLLOW-ON FUNCTIONAL TEST PERFORMED (OPERATING AT FULL HOT TEMPERATURE FOR 20 MINUTES). THE OVEN WAS RETURNED TO SERVICE SIJan 27, 2006 · N177UA · Boeing 747422SDR SWAA060304Coffeemaker · leakingSMOKE/STEAM IN AFT GALLEY. FOUND AFT COFFEEMAKER LEAKING CAUSING STEAM. REMOVED AND REPLACED AFT COFFEEMAKER PER MM.Jan 25, 2006 · N334SW · Boeing 7373H4SDR DL777060073Chiller · odorON PRE-FLIGHT, F/A REPORTED BURNING SMELL IN AFT GALLEY. FAULT LIGHT ON CHILLER. REPLACED CHILLER.Jan 22, 2006 · N865DA · Boeing 777232SDR AALA20060069Oven · dirtyLHR INFLIGHT T107/20JAN - SMOKE COMING FROM FORWARD GALLEY OVEN. RETURNED TO LHR AND LANDED WITHOUT INCIDENT. FOUND DEBRIS BURNING IN OVEN. CLEANED DEBRIS AND PULLED AND COLLERED CIRCUIT BREAKERS. REPLACED FIRST CLASS OVEN NUMBER ONE AND TWO AT JFK. SYSTEJan 20, 2006 · N755AN · Boeing 777223SDR DL777060046Oven · odorAFT OVEN, STRONG ELECTRICAL ODOR AS WELL AS ELECTRICAL SMOKE. NO FAULT LIGHT, NO POPPED CIRCUIT BREAKERS. REPLACED OVEN.Jan 14, 2006 · N866DA · Boeing 777232SDR AALA20060019Coffeemaker · dirtyMSY - ELECTRICAL SMOKE AND FUMES REPORTED BY FLIGHT ATTENDANTS AND PASSENGERS. MID GALLEY COFFEEMAKERS REPORTED HOT BY FLIGHT ATTENDANTS. INSPECTED AIRCRAFT AND FOUND MELTED GALLEY CART SEAL UNDER FORWARD COFFEEMAKER HOTPLATE AND COFFEE POT. CLEANED HOTPLATEJan 11, 2006 · N191AN · Boeing 757223SDR CA060110007Oven · shortedOVEN NR 02-02-17535 OVEN NR 3 IN AFT GALLEY EMITTED AN ELECTRIC SHOCK TO F/A UPON TOUCHING IT. MEL ERASED IN CCS AND CB PULLED AND COLLARED BY FLIGHT CREW. REPLACED NR 3 OVEN CONTROLLER FUNCTION CHECK SATISFACTORY.Jan 10, 2006 · Airbus A319114SDR CA060104005Oven · shortedFWD GALLEY OVEN FIRE EXTINGUISHED WITH 2 FIRE EXT BOTTLES ACTION. FWD GALLEY NR1/NR 2 OVENS REPLACED. FUNCT CHKD SERV NR 1 OFF HK76R5 NR 2 OFF 8203-17-000 S/N 9403-6150. NR 1 ON 8203-17-000, S/N 96-11-7934 NR 2 ON 568K81.Jan 4, 2006 · Airbus A330*SDR 0600083304Oven · smokeWORLD BUSINESS CLASS OVEN NR 3 HAD AN ELECTRICAL FIRE (SMOKE). MAINTENANCE FOUND OVEN CIRCUIT BREAKER TRIPPED. CB WAS COLLARED AND OVEN WAS DEFERRED INOP. OVEN WAS REPLACED IN AMS AND TESTED OK.Jan 3, 2006 · N804NW · Airbus A330323SDR CALA0600001Coffeemaker · inoperativeTHE ESPRESSO COFFEEMAKER IN FIRST CLASS GALLEY OVERHEATED AND GAVE OFF A BURNING ELECTRICAL ODOR WHILE AT CRUISE PORTION OF FLIGHT. CIRCUIT BREAKERS 208 AND 209 WERE PULLED AND THE ODOR CEASED. THE ESPRESSO COFFEEMAKER WAS REMOVED AND REPLACED, OPERATIONAL CJan 2, 2006 · N69063 · Boeing 767424ERSDR SWAA060009Coffeemaker · faultyDECLARED EMERGENCY, BURNING ODOR IN AFT GALLEY. REMOVED AND REPLACED AFT GALLEY INBOARD COFFEEMAKER PER MM.Jan 1, 2006 · N414WN · Boeing 7377H4SDR DLM88050837Coffeemaker · burnedA/C ARRIVED WITH AN INBOUND STATING 'AFTER LANDING FLIGHT ATTENDANTS REPORTED ACRID SMELL IN AFT CABIN. SMELL DISSIPATED QUICKLY. ALL COCKPIT INDICATIONS APPEARED NORMAL. ANTI ICE WAS ON AND AIRFOIL WAS OFF'. AFTER C/W OPN 5088, MX FOUND COFFEE POTS HOT Dec 29, 2005 · N905DL · Doug MD88SDR CALA0500454Oven · noneCREW OBSERVED SMOKE ENTERING COCKPIT WHILE IN CRUISE. 1ST CLASS OVENS WERE IN USE. FLT ATTENDANT TURNED OFF 1ST CLASS OVENS & SMOKE CEASED. FLT CONTINUED & LANDED WITHOUT FURTHER PROBLEM. VISUAL INSPECTION PERFORMED BEHIND OVENS, COFFEEMAKER, & P-6 PANELS,Dec 27, 2005 · N76354 · Boeing 7373T0SDR AU510001938Oven · failed(AUS) SMOKE AND FUMES IN FORWARD GALLEY. INVESTIGATION FOUND GALLEY OVEN C206 CIRCUIT BOARD DIODE BURNED. INVESTIGATION ALSO FOUND A BURNED RESISTOR R429 ON THE POWER SWITCH BOARD PNO LK25-85-4B. (OTHER CAUSE: MATERIAL ) (CASA NR 510001938)Dec 12, 2005 · Boeing 737*SDR AU510001748Oven · faulty(AUS) NR 5 REAR GALLEY OVEN FAULTY. SMOKE AND FUMES IN CABIN. SUSPECT CAUSED BY SHORTED/BURNED OVEN FAN MOTOR. (CASA NR 510001748)Dec 12, 2005 · Boeing 767*SDR ASOA051079Odor · detectedTHE FLIGHT ATTENDANT REPORTED A POSSIBLE BURNING ODOR ASSOCIATED WITH THE NR 1 GALLEY HEATER. (M)Dec 10, 2005 · N821AS · Cndair CL6002B19SDR CA051206001Coffeemaker · burnedIN CRZ VENTRE GALLEY COFFEE MAKER GAVE A FLASH AND ASH WAS DEPOSITED ALL AROUND, ELEC FUMES SMELT BY F/A`S, ALL CBS IN AREA PULLED, UTIL BUSSES DEPOWERED. DIVERTED YYT FOR MTCE/SAFETY CK. FOUND LOWER C/M MID GALLEY HEATING ELEMENT INSULATION BLOWN OUT WITH PDec 6, 2005 · Boeing 767300SDR DL76S050764Coffeemaker · arced1RT GALLEY G1A COFFEEMAKER MAKES ELEC ARCING SOUND WHEN TURNED ON. REPLACED SAME.Dec 5, 2005 · N133DN · Boeing 767332SDR CALA0500427Coffeemaker · burnedA STRONG ELECTRICAL ODOR THAT APPEARED TO BE COMING FROM THE FORWARD GALLEY WAS NOTED IN THE COCKPIT AND CABIN WHILE EN ROUTE TO IAH. THE OVENS, COFFEEMAKERS, AND GALLEY POWER WAS TURNED OFF. THE ODOR DISSIPATED AND THE FLIGHT WAS CONTINUED TO IAH WHERE IT LDec 4, 2005 · N17620 · Boeing 737524SDR AALA20050789Oven · dirtySNN - REPORT OF SMOKE FROM DOOR SEAL AT NUMBER 3 OVEN IN AFT GALLEY. SMOKE STOPPED WHEN OVEN SWITCHED OFF. CLEANED OVENS IN AFT GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 30, 2005 · N190AA · Boeing 757223SDR CA051125007Coffeemaker · burned(CAN) FAULT: IN CRZ VENTRE GALLEY COFFEE MAKER GAVE A FLASH AND ASH DEPOSITED ALL AROUND, ELECTRIC FUMES SMELT BY F/AS, ALL CB'S IN AREA PULLED UNTIL BUSSES DEPOWERED. DIVERTED YYT FOR MTCE/SAFETY CHECK. FOUND LOWER C/M MID GALLEY HEATING ELEMENT INSULATION BNov 25, 2005 · Boeing 767383SDR AALA20050760Oven · smokeINFLIGHT, OVEN NR 6 IN COACH GALLEY WAS SMOKING FROM BEHIND OVEN. FLIGHT ATTENDANT REPORTED ELECTRICAL SMELL. CLEANED NUMBER SIX OVEN AND RAN NUMBER 6 AND NUMBER 5 OVENS AND AFT GALLEY RIGHT CHILLER. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 20, 2005 · N346AN · Boeing 767323SDR DL73S050713Coffeemaker · arcedSPARK JUMPED OUT IN FRONT OF AFT GALLEY, NR 2 POSITION COFFEEMAKER. REPLACED SAME.Nov 16, 2005 · N309DL · Boeing 737232SDR AU510002118Oven · failedSPARKS AND ELECTRICAL FUMES EMANATING FROM REAR GALLEY AREA. INSPECTION COULD FIND NO FAULTS BUT THE OVEN WAS REPLACED AS A PRECAUTION. INVESTIGATION CONTINUING.Nov 11, 2005 · Boeing 737800*SDR AALA20050733Coffeemaker · inoperativeNUMBER TWO COFFEE MAKER SPARKS. ITEM DEFERRED AS PDL 2599J AUGH 119168CC. PULLED CIRCUIT BREAKER AND COLLARED.Nov 10, 2005 · N39364 · Boeing 767323SDR AALA20050734Oven · fireFIRE INSIDE FIRST CLASS OVEN. USED TWO FIRE EXTINGUISHERS AND PULLED CIRCUIT BREAKERS. AIR INTERRUPTED TO ATL. REPLACED OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 10, 2005 · N7535A · Doug DC982SDR DL76L050684Oven · contaminatedSIGNIFICANT WATER LEAK AFT GALLEY BEHIND OVENS. RTB. REMOVED OVENS LT SIDE OF AFT GALLEY. INSPECTED AREA AROUND OVENS, FOUND SMALL AMOUNT OF WATER IN OVENS BUT NOT OUTSIDE OF OVENS. CLEANED UP AREA. NO LEAKS NOTED.Nov 7, 2005 · N197DN · Boeing 767332SDR AALA20050728Oven · inoperativeAFT GALLEY NUMBER 9 OVEN BEGAN SMOKING WHILE ON AND WARMING MEALS. FLIGHT ATTENDANTS REPORTED SMOKE SMELL AS ELECTRICAL SMELL. SMOKE AND SMELL STOPPED ONCE OVEN WAS TURNED OFF. REPLACED AFT GALLEY NUMBER 9 OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION.Nov 5, 2005 · N787AL · Boeing 777223SDR CALA0500385Warmer · overheatedAN ELECTRICAL ODOR ACCOMPANIED BY MOMENTARY SMOKE CAME FROM THE AFT GALLEY WHILE EN ROUTE TO EWR. THE OVEN AND COFFEEMAKER CIRCUIT BREAKERS WERE PULLED AND THE SMOKE AND ODOR CEASED. THE FLIGHT CONTINUED TO EWR WHERE IT LANDED WITHOUT FURTHER PROBLEMS. MAINNov 4, 2005 · N78285 · Boeing 737824SDR AWXA200501328Coffeemaker · smokeSJC - SMOKE - FLIGHT ATTENDANT REPORTED A BURNING SMELL IN AFT GALLEY, FOLLOWED BY SMOKE. GALLEY C/B'S WERE PULLED AND WHEN THE 3RD COFFEEMAKER C/B WAS PULLED, SMOKE CEASED. 3RD COFFEE MAKER IS CURRENTLY ON MEL. MAINTENANCE REPLACED THE AFT NR 3 COFEEMAKER.Nov 1, 2005 · N819AW · Airbus A319132SDR AWXA200501286Oven · odorCREW REPORTED FORWARD OVENS EMIT NOXIOUS FUMES WHEN USED. MAINTENANCE REMOVED AND REPLACED FORWARD GALLEY NR 1 OVEN. OPERATIONAL CHECKS GOOD. VENDOR TEAR DOWN REPORT CONFIRMS REASON FOR REMOVAL. UNIT WAS RECEIVED WITH TEMPERATURES OUT OF RANGE. TEMPERATUROct 27, 2005 · N651AW · Airbus A320232SDR CALA0500372Coffeemaker · inoperativeTHE FORWARD ESPRESSO COFFEEMAKER BEGAN TO SMOKE AND GAVE OFF A BURNED ELECTRICAL ODOR WHILE EN ROUTE FROM EWR TO FCO. THE CIRCUIT BREAKER WAS PULLED AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED TO FCO WHERE IT LANDED WITHOUT FURTHER INCIDENT. THE ESPRESSOOct 23, 2005 · N76151 · Boeing 767224SDR CALA0500373Oven · inoperativeSMOKE AND A BURNING METALLIC ODOR CAME FROM THE FORWARD GALLEY 205 OVEN. THE GALLEY POWER WAS TURNED OFF AND THE SMOKE CEASED. THE FLIGHT ATTENDANT REPORTED THAT THE OVEN WAS EMPTY AT THE TIME OF THE OCCURRENCE. THE FORWARD GALLEY OVEN WAS REMOVED AND REPLAOct 22, 2005 · N37615 · Boeing 737524SDR 64710152005Coffeemaker · odorELECTRICAL BURNING SMELL IN CABIN. NO SMOKE.Oct 15, 2005 · N511QS · Gulstm GULFSTREAMGVSDR 2005UALA01124Smoke · detectedELECTRICAL ODOR (HEAT) APPARENT AROUND DOOR 2R. OPENED CLOSET AT 2R AND SMOKE WAS SEEN TO EXIT. GALLEY POWER TURNED OFF AND ODOR DISSIPATED. REPLACED TRANSFORMER 10/11/05. SYSTEM HAS BEEN FUNCTIONING NORMALLY AS OF 11/10/05. PROBLEM APPEARS TO HAVE BEEN A OOct 10, 2005 · N785UA · Boeing 777222SDR AU510001597Bearing · collapsedNR 1 AFT GALLEY CHILLER FAULTY. WORKSHOP INVESTIGATION FOUND THE FAN BLOWER MOTOR BEARINGS COLLAPSED.Oct 7, 2005 · Boeing 767338SDR CALA0500347Oven · smokeSMOKE IN AFT CABIN GALLEY AREA. REPLACED OVEN PER AMM 25-32-75.Oct 7, 2005 · N67134 · Boeing 757224SDR AU510001566Light · arced(AUS) REAR GALLEY POWER NR 2 INDICATOR LIGHT DAMAGED AND WIRES W315-61-16A AND W315-62-16N DAMAGED FROM ARCING.Oct 6, 2005 · Boeing 7377BXSDR YENA200572Coffeemaker · burnedNR 1 FLIGHT ATTENDANT REPORTED ODOR OF BURNING PLASTIC IN AFT GALLEY NEAR COFFEE POTS. PULLED COFFEE C/B'S STILL REPORTED ODOR FROM A/C LEFT BEHIND GALLEY CARTS. FOUND COFFEEMAKER 508 TO BE AT FAULT. FOUND STRONG ELECTRICAL ODOR COMING FROM COFFEEMAKER. REOct 2, 2005 · N623JB · Airbus A320232SDR AALA20050649Coffeemaker · smokeSDQ - INFLIGHT SMOKE STARTED COMING OUT OF THE BACK OF COFFEEMAKER NR 1. FOUND E-58 LABEL TAG BURNING. EXTINGUISHED LABEL TAG AND PLACARD COFFEEMAKER NUMBER 1. REPLACED COFFEEMAKER NUMBER 1. SYSTEM GROUND CHECKED NORMAL OPERATION.Sep 28, 2005 · N7083A · Airbus A300B4605RSDR QXEA200501267Receptacle · malfunctionedSEA FLIGHT NR 2137, BURNING ODOR FROM GALLEY, NO ODOR NOTED AFTER HOT JUGS TURNED OFF. MAINTENANCE REPLACED NR 2 HOT JUG ELECTRICAL RECEPTICLE. ALLOWED JUGS TO REMAIN ON FOR 15 MINUTES. NO BURNING ODOR NOTED. BOTH JUGS WORK AND CHECK GOOD. AIRCRAFT RETURNSep 27, 2005 · N346PH · Dhav DHC8202SDR FDK2005F00000Odor · detected(REF NR F05002) THE CREW REPORTED A SMOKE LIKE SMELL IN GALLEY DURING FLIGHT. MAINTENANCE PERFORMED A GVI TO GALLEY AREA AND WIRING. MAINTENANCE CHANGED TRASH OUT AND CLEANED COFFEE POTS. NO SMOKE SMELL DETECTED. (K)Sep 19, 2005 · N825MJ · Emb EMB145LRSDR AMTA200500706Oven · smokeOVEN SMOKING, GALLEY G1B. CLEANED SPILLS IN OVEN. RAN AT 450 DEGREES FOR 20 MINUTES, NO SMOKE NOTED. (M)Sep 17, 2005 · N518AT · Boeing 75723NSDR F05002Odor · detectedTHE CREW REPORTED A SMOKE LIKE SMELL IN GALLEY DURING FLIGHT. MAINTENANCE PERFORMED A GVI TO GALLEY AREA AND WIRING. MAINTENANCE CHANGED TRASH OUT AND CLEANED COFFEE POTS. NO SMOKE SMELL DETECTED.Sep 16, 2005 · N825MJ · Emb EMB145LRSDR 2005UALA00980Oven · smokeF/A REPORTS SMOKE COMING OUT OF OVEN. SECURED IT AND DIVERTING FLIGHT. INITIAL INSPECTION REVEALED A DIRTY FILM ON INTERIOR OF OVEN WITH A DISTINCT ODOR THAT COULD HAVE CAUSED "SMOKING" CONDITION. THE OVEN WAS INSPECTED AND CHECKED/TESTED PER MANUFACTURER'SSep 12, 2005 · N835UA · Airbus A319131SDR DL76G050537Oven · arcedOVEN NR 7 AFT GALLEY SPARKED WHEN TURNED ON AND POPPED C/B. REPLACED SAME.Sep 10, 2005 · N1603 · Boeing 767332SDR SWAA052706Coffeemaker · faultyELECTRICAL SMELL FROM AFT COFFEEMAKER. REMOVED AND REPLACED AFT COFFEEMAKER PER MM.Sep 6, 2005 · N385SW · Boeing 7373H4SDR NOCA1105Oven · inoperativeSMOKE IN AFT GALLEY. FLIGHT ATTENDANTS AND CREW DETERMINED THAT THE SMOKE WAS ORIGINATING FROM BEHIND THE CONTROL PANEL OF NR 6 OVEN AND NOT FROM CONTENTS BEING COOKED. THE OVEN INSERT WAS REMOVED, CIRCUIT BREAKER FOR NR 6 OVEN PULLED AND POWER TO AFT GALLEYSep 5, 2005 · N752NA · Boeing 75728A
Back to JASC 2530