Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2026030314255Oven · smokeOVEN SMOKING OR SPARKING, 408 OVEN STILL WORKED AFTER TURNED OFF. THEN SMOKED. C/B PULLED TO STOP THE SMOKE. REMOVED AND REPLACED THE OVEN MID GALLEY IAW AMM 25-32-02, OPS CHECKED GOOD.SDR CALA2026030214135Oven · smokeOVEN 709 IS SMOKING FOUND BURNED FOOD RESIDUE IN THE OVEN. ATTMEPTED TO CLEAN BUT OVEN STILL HAS SLIGHT SMELL. REQUESTING NEF FOR GALLEY OVEN 709. APPROVED FOR MEL 2520AV NEF APPLIED. REMOVED AND REPLACED NR 709 OVEN IN AFT GALLEY R4 DOOR IAW AMM 25-32-02/40SDR CALA2026022714115Oven · contaminatedDUE TO SMOKE IN THE CABIN ,PERFORMED SMOKE IN CABIN AMM 05 INSPECTION. PERFORMED SMOKE ODOR CONDITION INSPECTION IAW AMM 05-51-26-800-801-C1. ODOR CAME FROM BURNED FOOD IN OVER 205.SDR CALA2026022614111Oven · overtempFOUND AFT GALLEY NR 3 OVEN EXCESSIVELY OVERHEATED WITH THERMAL IMAGING. REMOVED OVEN TO INSPECT ELECTRICAL CONNENCTION AND FOUND NO DAMGE OR BURNING. PLACARDED AFT GALLEY NR 3 OVEN. CB PULLED MEL APPLIED PLACED ON NEF. PULLED AND COLLARED CIRCUIT BREAKER. SDR CALA2026022313966Oven · smokeOVEN SMOKING OR SPARKING 204 OVEN SMOKES AND SMELLS BAD CABIN CREW FILLED OUT FORM 46-6020 FOR SMOKE AND ODOR. GENERAL VISUAL INSPECTION OBSERVED MELTED CHOCOLATE INSIDE OVEN CAVITY. REQUEST DEFERRAL DUE TO TIME. PLACARD AND CIRCUIT BREAKER COLLAR APPLIED FOR SDR DALA2026022001225Oven · odorAIRCRAFT 5084, AFTER LANDING FA'S STATED THERE WAS A 1-2 MIN LIGHT ELECTRICAL PLASTIC BURNING SMELL FWD GALLEY TO ROW 2. ODOR OCCURED ON SHORT FINAL. CORRECTIVE ACTION: REPLACED F103 OVEN PER A321 AMM 25-32. (LP 8090424)SDR DXTA2026022006937Microwave Oven · faultedIN FLIGHT OUR FA ATTEMPTED TO USE THE MICROWAVE TO WARM PASSENGER FOOD. WITHIN 5 SECONDS OF USE, THE MICROWAVE BEGAN TO ARC INSIDE ON THE TOP, MADE A HIGH PITCH SQUEELING SOUND, AND GAVE OFF AN ACRID SMELL. WE STOPPED THE PROCESS AND ISOLATED THE CIRCUIT VIA TSDR AALA202602202970Coffeemaker · overheatedAIRCRAFT WAS NOT GROUNDED: AFT GALLEY COFFEE POTS HAVE ELECTRICAL BURNING SMELL. TURNED OFF AND SMELL WENT AWAY. ACCOMPLISHED JOB CARD 26L00021001 SMOKE ODER FUME INITIAL TROUBLESHOOTING DETERMINED AFTER LEFT COFFEE MAKER INOP CAUSEOF ELECTRICAL SMELL PLACED OSDR DALA2026021801147Oven · smoke(LOG 8105730) SMOKE COMING FROM OVEN. REMOVED FWD GALLEY OVEN AND INSPECTED CONNECTORS FOR OVERHEATING NO EVIDENCE OF BURING DETECTED. SMELLS LIKE OVEN CLEANER RESIDUE. R/R OVEN AT FWD GALLEY IN REF TO B737 AMM 25-31. OPS NORMAL.SDR CALA2026021813858Coffeemaker · smokeCOFFEEMAKER SMOKING OR SPARKING. FOUND AFT GALLEY COFFEE MAKER INOP WOULD NOT TURN ON. REMOVED AND REPLACED THE COFFEEMAKER IAW AMM 25-31-01 . RESET POWER BLEED COFFEEMAKER AND BREWED TWO POTS RUN TIME 15 MINUTED. NO ODER OR ELEC ODORS. CHKD OK.SDR DALA2026021601057Oven · odorELECTRICAL ODOR IN AFT CARGO AND AFT CABIN WITH APU AND ENGINES OFF AND GRD AIR CONNECTED. R & R THE OVEN IAW AMM 25-31 ON LOG PAGE 1450114.SDR SWAA2026021670422Door · looseFWD GALLEY COMPARTMENT DOORS ARE LOOSE 2-03; 7-08; 7-13. TIGHTENED THE FWD GALLEY COMPARTMENT DOORS IAW AMM 20-50-11SDR CALA2026021613777Oven · odorPILOT STATES APROX 10 MIN UNTIL LANDING RECEIVED CREW REST SMOKE FD EICAS MESSAGE WITH AURAL ALARM IN CREWREST SPACE. NO FIRE/SMOKE INDICATIONS ON THE FLIGHT DECK. REPEAT FROM PREVIOUS WRITEUP FROM LAST FLIGHT. UPDATED SDR INFO AND ADDED PICS UPDATED SDR INFO SDR AALA202602129244Oven · smokeAIRCRAFT WAS GROUNDED: STRONG ELECTRICAL OR BURNING SMELL IN BUSINESS CLASS WHEN COOKING MEALS IN MID GALLEY. SMELL DISSIPATED WHEN EVERYTHING WAS TURNED OFF. MAINTENANCE ACCOMPLISHED J/C 72L00021001 "INITIAL TROUBLESHOOTING DUE TO SOF" FOUND OVEN 4 IN MID GALSDR CALA2026021013644Oven · faultyOVEN 1ST CLASS NR 2 DIRTY AND HAS FOUL ODOR, REQUEST MEL FOR OVEN 2 IN FWD GALLEY. BREAKER PULLED & SECURED. COMPLIED WITH MEL, DDP. REMOVED AND REPLACED OVEN IAW 25-32-03/401, CLEANED INSIDE TRAYS, OPS CHKD GOOD.SDR CALA2026020913634Oven · smokeOVEN 707 EMITTED BLACK SMOKE CB PULLED AS RECAUTION OVEN 707 IN REAR GALLEY, SMOKE EVENT. CONDITIONAL INSPECTION CARRIED OUT I.A.W AMM 05-51-58. BURNT FOOD IN OVEN FOUND. FORM 46.6020 SMOKE AND ODOR QUESTIONAIRE COMPLETED IAW 04-20-16 OF THE GMM. OVEN PLACEDSDR CALA2026021013663Oven · dirtyFA`S REPORTED SMOKE FROM BOTH FWD GALLEY OVENS 1 & 2 AFTER TAKE OFF STOP PED AFTER TURN OFF. FOUND OVEN 205 DIRTY WITH FOOD OIL, CLEANED BOTH OVENS RAN OVENS 204 AND 205 NO SMOKE OR ODOR DETECTED, DEFFERED FWD OVEN 205 IAW NEF 2510AU FOUND MOUNTING SCREWS CSDR CALA2026020613605Oven · dirtyFA REPORTED ELECTRICAL BURNING ODOR IN AFT GALLEY. PULLED ALL AFT CB. NO SMOKE REPORTED. UPDATED WITH FORM 48-6020 PULLED OVEN 424 AND INSPECTED ELECTRICAL CONNECTION FOUND NO DEFECTS, UPON FURTHER INSPECTION FOUND FOOD DEBRIS AT BOTTOM OF OVEN 424 CLEANED DESDR DALA2026020600856Coffeemaker · odorBURNT ELECTRIC SMELL IN FWD GALLEY LEFT COFFEE POT WHEN IN USE. FOUND BURNT SMELL COMING FROM COFFEE MAKER LOCATION 107. REMOVED COFFEE MAKER AND INSPECTED WIRES AND HARNESS FOR DAMAGE. NO TROUBLE FOUND. INSTALLED A NEW COFFEE MAKER. OPS CHECKED AND LEAK CHECKSDR AALA202602046351Coffeemaker · leakingAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT REPORTED A RUBBER BURNING SMELL IN THE AFT GALLEY BY THE LEFT SIDE JUMPSEAT DURING DESCENT. THE SMELL CAME AND WENT SEVERAL TIMES IN FLIGHT. MAINTENANCE PERFORMED TROUBLESHOOTING PER TASK CARD 26L00021001 AND FOUND ASDR CALA2026020413579Oven · faultedLOUD SQUEALING NOISE FROM SOMEWHERE IN AFT GALLEY. NOISE STARTED DURING CLIMBOUT. INSPECTED AFT GALLEY AREA & FOUND NR 3 OVEN VENT FAN VERY NOISY. DEACTIVATED AND DEFERRED OVEN IAW NEF 2500BI & NOISE RETURNED TO NORMAL LEVELS. CABIN PRESSURE LEAK TEST PESDR CALA2026020213511Coffeemaker · odorF/A REPORTS ABNORMAL ODOR IN AFT CABIN. FOUND ODOR TO BE BURNED COFFEE, COMPLIED WITH INSPECTION AMM 05-51-26-800-801-C1.SDR AALA202602025381Oven · overheatedAIRCRAFT WAS NOT GROUNDED: AT CRUISE FLIGHT ATTENDANT REPORTED FORWARD GALLEY OUTBOARD OVEN IS SMOKING AND HOT. REMOVED AND REPLACED FORWARD #1 OVEN. PER AMM 25-32-03-400-801. OPS CHECK GOOD.SDR CALA2026020113460Oven · fodFLIGHT CREW REPORTED, FWD GALLEY HAS A STRONG ELECTICAL BURNING ODOR ON GALLEY CARTS ON BOARD. NO SIGNS OF SOURCE. UNABLE TO DUPLICATE, INSPECTED AND SUSPECT SOME PLASTIC MAY HAVE BEEN BURNED IN THE OVEN FAN ON PREVIOUS FLIGHT. CLEANED OUT OVEN. VERIFIED NO SDR AALA202602026988Coffeemaker · sparksAIRCRAFT WAS NOT GROUNDED: AFT GALLEY COFFEE MAKER (CM4) ARCING WHEN TURNED ON. MAINTENANCE REPLACED COFFEEMAKER AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 25-35-15.SDR CALA2026013013454Oven · dirtyPERFORM CONDITIONAL INSP IAW AMM TASK 05-51-58-800-801-C3, ACCOMPLISHED CONDITIONAL INSPECTION IAW AMM 05-51-58-800-801-C3. NO SIGNS OF ARCHING OR BURNING. UPON FURTHER VISUAL AND OPS INSPECTION, FOUND OIL ON BOTTOM INTERIOR OF OVEN AND ON HEATING ELEMENT OFSDR DALA2026020300804Vent · cloggedBURNING ELECTRICAL SMELL DURING CRUISE IN AFT PART OF FORWARD GALLEY BY DOOR 1R. TURNED OFF CIRCUIT BREAKERS. SMELL DISSIPATED. AFTER LANDING THERE IS STILL A TRACE OF THE SMELL. UPON ARRIVAL TO A/C NO SMELL NOTED. PERFORMED OPS CHECKS OF OVEN AND COFFEE MAKERSDR CALA2026020913635Oven · dirtyOVEN 705 IN AFT GALLEY NEEDS CLEANING. IT IS SMOKING WHEN IN USE. TRIED CLEANING OVEN, HEAVILY SOILED BEHIND BACKPLATE. REQUIRES DEEP CLEAN OR REPLACEMENT. DUE TO SMOKE REPORTED, REQUESTING NEF 2520AV DUE TO SHORT GROUND TIME AT LHR. CB PULLED AND COLLARED FSDR SWAA2026012964972Coffeemaker · odorFIRST OFFICER`S SIDE AFT COFFEEMAKER HAD A BAD ODOR. R & R THE AFT OTBD COFFEEMAKER IAW AMM 25-30-01. OPS CHECKED GOOD.SDR CALA2026012613254Oven · contaminatedON DEP AFT FAS REPORTED BURNT RUBBER ODOR. SUB SIDED AFTER APP ROX 15 MI NS. NO OTHER ABNORM IN PIC OF ODOR REPORTING SHEET ADDED. FILLED OUT BY AFT FA. IAH HMC'S REPORT THAT THE AC DID NOT GET DE-ICED BEFORE DEPARTURE RAN PACKS INDIVIDUALLY ON FULL HOT & FUSDR CALA2026012613245Oven · contaminatedOVEN SMELLS BAD, FWD GALLEY OVEN 204 INOPERATIVE. PULLED AND COLLARD CIRCUIT BREAKER. OVEN 204 INOP. BAD ODOR IS FROM FOOD. COMPLIED WITH NEF 2510AU OPS CHKD IAW AMM 25-34-00, SATISFACTORY WITH NO WEIRD ODOR. DDP COMPLIED WITH. CLEARING NEF.SDR CALA2026012613238Sink · cloggedMID LAV OVER FLOW BLACK GOING DOWN ISLE. RETURNING TO EWR FOUND LAV C SINK CLOGGED. UNCLOGGED MID LAV SINK USING COMPRESSED AIR GUN. UNCLOGGED AND WATER DRAINS NORMALLY FROM THE DRAIN MAST. VERIFIED NO FURTHER LEAKS HAPPENED INSIDE FWD AND AFT CARGO COMPARTESDR CALA2026012813399Oven · odorFWD GALLEY OVEN 108 HAS STONG BURNING ODOR WHEN USED. RESET THE OVEN CIRCUIT BREAKER, OVEN 108 OPS CHECKED GOOD IAW AMM 25-32-00SDR AALA202601232650Oven · smokeAIRCRAFT WAS NOT GROUNDED: FIRST CLASS GALLEY OVEN NUMBER 2 IS VERY DIRTY AND SMOKES WHEN USED. REMOVED AND REPLACED GALLERY OVEN. PER CMM 25-37-26.SDR CALA2026011913079Oven · smokeFIRE OBSERVED AND EXTNG FWD GALLY OVEN 204. COMPLETED SMOKE AND ODOR FORMS BY FA AND CAPTAIN PERFORMED GVI OF OVEN 204, FOUND BURNT RESIDUAL FOOD ON INSERT. PHOTOS ATTACHED REMOVED AND REPLACED FWD GALLEY OVEN 204. REF AMM 25-34-00 OPS CHECK GOOD.PARTS USED: SDR AALA202601144384Oven · smokeAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: DURING CLIMB ELECTRICAL SMOKE ODOR NOTICE IN FLIGHTDECK AND CABIN. AIRCRAFT AIR INTERRUPTED BACK TO AND LANDED SAFELY AT ORD. ACCOMPLISHED W/C 08L00021001. FOUND NUMBER 2 OVEN OMITTING ELECTRICAL ODOR. RSDR DALA2026011400326Oven · smokeAFT GALLEY OVEN GENERATING SMOKE WHEN IN OPERATION. OVEN FWD TO NEF THEN REPLACED OVEN. OK FOR SERVICE. (1398296)SDR AALA202601136280Oven · smokeAIRCRAFT WAS NOT GROUNDED: FLIGHT ATTENDANT IN FORWARD GALLEY REPORTED OVEN ON AIRCRAFT RIGHT STARTED SMOKING OR STEAMING AS SOON AS SHE TURNED IT ON EVEN BEFORE IT HEATED UP. REMOVED AND REPLACED FORWARD RIGHT GALLEY OVEN IAW AMM 25-32-00. OPS CHECKED GOOD.SDR AALA202601064833Oven · odorAIRCRAFT WAS GROUNDED: SMELL OF MELTED PLASTIC NOTICED IN THE COCKPIT AS WELL AS AFT CABIN. #1 FA SHUT OFF OVEN IN FORWARD GALLEY AND SMELL DISSIPATED. NOTHING FURTHER NOTED. AFTER COMPLETING J/C 26L00021001 SOF TROUBLESHOOTING FOUND NUMBER ONE OVEN COULD BE TSDR CALA2026010512659Oven · smokeOVEN 706 BURN SMELL WITH SMOKE & POPPING NOISE. ERROR CODE 2000, REPLACED OVEN 706 IAW AMM 25-32-00. OPS CHECKED OK. LEAK CHECKED OK.SDR CALA2026010212575Chiller · odorSMOKE ODOR CONDITIONAL INSP REQUIRED PER AMM 05-51-XX DUE TO AN INCIDENT REPORTED BY THE CREW. DO TO REPORT OF BURNING SMELL BY F/A IN THE AFT GALLEY, A/C REQUIRES INSPECTION PER AMM 05-51-56-200-801 FOLLOWED FIM 21-00 TASK 830 FOUND SOURCE OF SMELL FROM CHILLSDR DALA2025123109536Structure · damagedCORROSION ON COMPARTMENTS 510, 511 AND 512 ON GALLEY 5 AFT GALLEY AREA. REPAIRED PER ER/A 630809-14. (1377077)SDR DALA2025123109535Structure · damagedFOUND LAMINATE DAMAGED IN FWD GALLEY. REPLACED LAMINATE IN FWD GALLEY PER A319 AMM 25-31. (1376825)SDR DALA2025123109534Structure · damagedFOUND LAMINATE DAMAGED IN AFT GALLEY. CORRECTIVE ACTION: REPLACED LAMINATE PER A319 AMM 25-31. (1376824)SDR DALA2025122909439Unknown · leakingATB- DUE TO BROWN FLUID LEAKING IN THE AFT GALLEY AREA. INSPECTED DRAINS IN GALLEY AND LAVATORIES WITH ALL DRAINS FOUND NORMAL WITH NO BLOCKAGE. DRAIN MAST OPERATES NORMAL AND NO WATER FOUND COMING FROM BELLY DRAINS. (7364882)SDR HNAA2025122900865Hot Water Pot · odorIN FLIGHT FA REPORTS AN ELECTRICAL BURNING SMELL IN GALLEY AREA. CONFIRMED HOT JUG OFF. NO C/B POPPED. SLAVED IN HOT JUG. OPS CHECK GOOD. LEFT HOT JUG ON FOR 20MINS WITH NO BURNING SMELL OBSERVED. REMOVED DEFECTIVE HOT JUG FROM A/C.SDR DALA2025122409402Oven · dirtyDIV - TO TPA DUE TO AN ODOR IN THE FORWARD GALLEY. FOUND MELTED ALUMINUM AND BURNT FOOD DEBRIS IN FORWARD GALLEY OVEN. OVEN LOCKED OUT AND PLACED ON NEF. 24DEC25 - REPLACED OVEN. (LP 7715946, 7715951)SDR DXTA2025122406274Microwave Oven · defectiveOVEN SMOKED WHEN IN COMBINATION MODE OR MICROWAVE MODE. IN MICROWAVE MODE IT BURNT A BLACK CIRCLE IN TOAST. REMOVED AND REPLACED THE OVEN IAW GL-7500 BD700-3AB48-10200-00 COMBI MICROWAVE REMOVAL/ INSTALL / MANUAL. OPS CHECK GOOD, NO DEFECTS NOTED.SDR CALA2025122112277Oven · dirtyELECTRICAL BURNING ODOR IN FLT DECK, DURINGTAXI IN. PERFORMED CONDITIONAL INSECTION IAW AMM TASK 05-51-26-800-801-C1 , RAN ENGINES , PACKS , & RECIRC FANS, UNABLE TO DUPLICATE FAULT, SUSPECT SMOKE WAS CONFUSED WITH RESIDUAL FOOD FOUND IN INBD OVEN CAVITY , CLSDR AALA202512234111Coffeemaker · odorAIRCRAFT WAS GROUNDED: REAR OF AIRCRAFT PAST ROW 25 HAS OFFENSIVE ODOR. MAINTENANCE ISOLATED THE SOURCE OF THE ODOR TO THE AFT GALLEY COFFEE MAKERS AND REPLACED THEM PER AMM 25-35-15.
Back to JASC 2530