Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CA010906008Controller · failed(CAN) SMELL AND SMOKE COMING OUT NR 2 GALLEY OVEN. OVEN CONTROLLER REPLACED. OPERATION CHECKED FOR ONE HOUR. NO SIGN OF VERHEATING, CONSIDER SERVICEABLE.SDR 2001UALA01638Oven · contaminatedFIRST GALLEY OVEN IS SMOKING. THE MECHANIC CLEANED FOOD FOUND IN THE OVEN. OPS CHECKED OKAY.SDR AUS20010841Coffeemaker · shorted(AUS) CENTRE GALLEY NR 3 BEVERAGE MAKER TEMPERATURE SENSOR SHORT CIRCUITSDR AUS20010802Coffeemaker · faulty(AUS) FORWARD GALLEY CENTRE COFFEE MAKER FAULTY. DURING RECTIFICATION OF THE FAULT IT WAS FOUND THAT THE COFFEEMAKER WAS THE INCORRECT PART NUMBER FOR FITMENT TO THIS MODEL AIRCRAFT. UNAPPROVED PART.SDR SIMA200121901Beam · corrodedABI - DURING MBB INSPECTION, FOUND CORROSION ON THE GALLEY CENTER BEAM. CORROSION WAS REMOVED AND REPAIR WAS CARRIED OUT IAW EMB REPAIR STATEMENT. AIRCRAFT WAS THEN RETURNED TO SERVICE. (M)SDR DL76G011262Odor · detectedATB FOR ELECTRICAL SMELL IN AFT GALLEY...CREW TURNED OFF OVENS AND RECIRC FANS AND UTILITY BUSSES AND SMELL DISSIPATED. MAD MTC INVESTIGATING.SDR DLM11011249Chiller · defectiveHEAVY ELEC BURNING SMELL FROM FWD GALLEY NOTED IN COCKPIT ALSO FLT ATTENDANT PULLED BREAKERS. CA FD OVEN 102 HAS ELEC SMELL. REPLACED OVEN AND CHILLER, CKS GOOD.SDR Z0A0106004Odor · detectedDURING CRUISE THERE WAS A BURNING ELECTRICAL ODOR IN THE FWD GALLEY. THE CREW TURNED OFF POWER TO THE FWD GALLEY. ALL EQUIPMENT IN AND AROUND THE GALLEY WERE CHECKED. THERE WERE NO PARTS REPLACED AND THE CONDITION COULD NOT BE DUPLICATED. LAST CHECK C NONESDR DL76L011239Coffeemaker · dirtyFLT DIVERTED TO BOS WITH BURNING SMELL IN AFT GALLEY. REMOVED ALL AFT COFFEEMAKERS AND CLEANED AREA OF COFFEE RESIDUE. INSPECTED AFT GALLEY FOR OTHER SOURCE OF SMELL. NONE FOUND. REPLACED NR 1 AND NR 3 COFFEEMAKERS PRECAUTIONARY.SDR 0102565649Oven(YXJ) FLIGHT ATTENDANTS REPORTED NBR 2 GALLEY OVEN OVERHEATED WITH ALL POWER REMOVED. APPROPRIATE CIRCUIT BREAKERS WERE PULLED. OVEN WAS STILL DEEMED OVERHEATED 40 MINUTES AFTER BREAKERS WERE PULLED. FLIGHT DIVERTED TO YXJ AND LANDED WITHOUT INCIDENT. MAINTSDR DLM88011188Coffeemaker · malfunctionedAFT GALLEY OUTBOARD COFFEEMAKER PRODUCED ELECTRICAL SMOKE. PULLED C/B. REPLACED DISPENSER. NEW UNIT CKS OK AND DOES NOT PRODUCE ANY ABNORMAL ODORS AFTER 30 MINS OPERATION.SDR AALA20011415Indicator · shortedORD - FLT 42 - AFTER TAKEOFF, FIRST CLASS GALLEY POWER ON INDICATOR LIGHT SHORTED CAUSING SMOKE IN GALLEY. CIRCUIT BREAKER PULLED AND POWER TO GALLEY SECURED FOR DURATION OF FLIGHT. REPLACED FIRST CLASS GALLEY POWER ON INDICATOR LIGHT ASSEMBLY. SYSTEM GROUNSDR 2001F00445Connector · dirtyFLT 5882 - PHX-XNA - SHORTLY AFTER ARRIVING IN XNA, THE FLIGHT ATTENDANT REPORTED SMOKE COMING FROM THE COFFEE POTS. THE CREW SECURED THE CB'S AND MAINTENANCE PERFORMED AND INSPECTION OF THE COFFEE POTS AND DEFERRED THE ITEM. LATER MAINTENANCE CLEANED THE COSDR DL777011122Odor · detectedSULFER/ELECTRICAL SMELL AFT GALLEY TURNED OFF CHILLERS AND OTHER GALLEY ELEC EQUIP AND SMELL DISSIPATED. RAN GALLEY COMPONENTS AFT GALLEY, NO UNUSUAL SMELL NOTED.SDR VNAA0107003Coffeemaker · malfunctionedTHE FLIGHT ATTENDANT REPORTED THAT FUMES FROM AN OVERHEATED HOT JUG WAS MAKING HER ILL. MAINTENANCE INSPECTED AND REPLACED THE NR 2 HOT JUG IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 25-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASESDR AUS20010682Oven · faulty(AUS) OVEN C207 CONTAMINATED. WHEN THE OVEN WAS OPERATED A LARGE AMOUNT OF SMOKE WAS GENERATED DUE TO EXCESS OIL IN THE OVEN COMPARTMENT.SDR AWXA0001907Oven · smokeMCO- SMOKE IN FWD GALLEY - FLT 561 - EN ROUTE FROM PHX TO MCO THE OUTBOARD OVEN IN GALLEY GIB STARTED SMOKING. THE FLIGHT ATTENDANT TURNED THE OVEN OFF AND PULLED THE CIRCUIT BREAKER. REMOVED THE GALLEY HALON FIRE EXTINGUISHER AND STOOD BY TO ENSURE THERE WASDR DL757011048Oven · malfunctionedF/C AFT OVEN WORKING INTERMITTENTLY, MAY HAVE SEEN SPARKS ABOVE BUN WARMER. OVEN APPEARS TO OPERATE NORMAL AT GATE. FOR PRECAUTION C/B PULLED AND COLLARED. OVEN FWD TO MCO AND PLACARD.SDR DL76G011021Oven · faultyAIR TURNBACK DUE TO SMOKE IN CABIN. FOUND OVEN IN MID GALLEY AT FAULT. REPLACED SAME.SDR DLM88011014Oven · malfunctionedSHORTLY AFTER T/O STRONG ELECT SMELL IN COCKPIT AND FWD GALLEY AREA RETURNED TO FIELD. FOUND BURNING SMELL COMING FROM F/C GALLEY OVEN. REPLACED OVEN AND FOOD CARRIER. OPERATED NEW OVEN, CKS GOOD AND SMELL GONE.SDR DLM88010994Coffeemaker · smokeAFT GALLEY COFFEEMAKER SMOKING. REMOVED AND REPLACED AFT COFFEEMAKER. A/C RIGHT SIDE COFFEEMAKER OPS CHECKS NORMAL.SDR QXEA0101039Receptacle · arcedSEA- ELECTRICAL SMELL COMING FROM COFFEE POT. SMELL WENT AWAY WHEN TURNED OFF. MAINTENANCE INSPECTED AIRCRAFT AND FOUND TOP COFFEE RECPTICLE SHOWING SIGNS OF ARCING. REPLACED RECPTICLE. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA01BT114Receptacle · odorGSP---CO4088, CREW REPORTED LEFT HAND COFFEE RECEPTACLE GIVES OFF BURN SMELL. MAINTENANCE PLACED BOTH COFFEEMAKERS ON MEL AND RETURNED THE AIRCRAFT TO SERVICE.SDR QXEA0100936Receptacle · odorPDX- FLIGHT ATTENDANT REPORTS ELECTRICAL SMELL IN CABIN. REMOVED AND REPLACED BEVERAGE HEATING RECEPTICLE. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA01BT113Receptacle · faultyEWR--CO4228, CREW REPORTED BURNING SMELL COMING FROM COFFEE POT.....MAINTENANCE REMOVED AND REPLACED COFFEE POT RECEPTACLE IAW EMB145 MM #25-31-00....OPS. CHECKED GOOD. AIRCRAFT RETURNED TO SERVICE.SDR C2XA01IA260Coffeemaker · faultyIAH - FLIGHT 4028, THE CREW REPORTED A SMOKE ODOR COMING FROM THE GALLEY AREA IN FLIGHT. THE POWER FOR THE GALLEY WAS SHUT OFF AND THE CIRCUIT BREAKERS FOR THE GALLEY WERE PULLED, WITH DISSIPATION OF THE ODOR FOLLOWING. THE AIRCRAFT CONTINUED TO IAH WHERE ITSDR DL757010891Oven · smokeSTRONG ELEC SMOKE ODOR AND LIGHT SMOKE DETECTED FROM FIRST GALLEY OVEN AREA. REPLACED F/C OVEN.SDR 0102006313Oven · fireDURING CRUISE, THE NR 4 GALLEY NR 1 OVEN CONTENTS CAUGHT FIRE. FLIGHT ATTENDANTS PULLED CIRCUIT BREAKERS, REMOVED FOOD, AND FOUND SUBSTANTIAL AMOUNT OF GREASE ON BOTTOM OF OVEN. MAINTENANCE INSPECTED OVEN AREA, ELECTRICAL WIRING AND CONNECTIONS CHECKED OK. SDR C2XA01CL121Connector · burnedCLE FLT 3618 THE CREW REPORTED ELECTRICAL BURNING SMELL COMING FROM COFFEE WARMER AREA. MAINTENANCE INSPECTED AND FOUND COFFEE WARMER CONNECTOR BURNT. MAINTENANCE REPLACED BURNT COFFEE WARMER CONNECTOR. PERFORMED OPERATIONAL CHECKS AND AIRCRAFT WAS RETURNESDR 2001UALA00812Smoke · malfunctionedOVEN SMOKING.SDR DL777010806Coffeemaker · malfunctionedAFT COFFEEMAKER SPARKING. REPLACED COFFEEMAKER, CHECKS OK.SDR DLM11010803Chiller · faultyFRC-250-XX000 SEE LOGBOOK FOR DETAILS - G4 CHILLER SHUT DOWN DUE ELEC SMELL. REMOVED AND REPLACED CHILLER.SDR DLM90010801Oven · faultyFLT ATT SMELLED SMOKE IN FIRST CLASS AREA RIGHT AFTER T/O TURNED OVENS OFF AND GALLEY POWER OFF. SMOKE AND SMELL PERSISTED. FOUND F/C OVEN WITH STRONG BURNING SMELL. REPLACED SAME. NO ODOR PRESENT.SDR 2001UALA00786Oven · malfunctionedOVEN SMOKING.SDR 2001UALA00931Controller · smokeP62 CART CONTROLLER IS SMOKING WHEN THE PIGTAIL IS UNPLUGGED.SDR 0101871155Harness · burnedDURING CLIMBOUT OF MSP, CABIN CREW REPORTED SMOKE AND ODOR IN MID CABIN. FOLLOWED COM PROCEDURE WITH NO NOTICEABLE CHANGE IN CONDITION. FLIGHT RETURNED TO MSP AND LANDED WITHOUT INCIDENT. MAINTENANCE DRAINED GEARBOX AND RESERVICED. CHANGED SOCKS AND BURNEDSDR AT0100155Coffeemaker · shortedSMELLED SMOKE IN FLIGHT DECK. REPLACED SHORTED COFFEEMAKER.SDR 0101946642Receptacle · faultyON LANDING, FLIGHT ATTENDANT NOTICED SPARKS AND FLAME AT NR 2 GALLEY NR 2 COFFEEMAKER. REPLACED COFFEEMAKER ELECTRICAL RECEPTACLE. OPERATIONAL CHECK NORMAL.SDR 2001UALA00721Smoke · detectedFORWARD GALLEY HAS ELECTRICAL SMOKE AND SMELL. NOT ENOUGH INFORMATION TO DETERMINE CAUSE. FORWARD GALLEY HOT FOOD UNIT WAS DISCONNECTED AND REPLACED BY GATES GOURMET. NEW UNIT INSTALLED AND OPERATION CHECKS NORMAL.SDR 0101676625Wire · shortedDURING FLIGHT, THE NR 2 HOT PLATE SPARKED AND EMITTED SMOKE RESULTING IN TRIPPING OF THE CIRCUIT BREAKER. AIRCRAFT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. REPAIRED CHAFED WIRE. OPERATIONAL CHECK GOOD.SDR DL777010697Oven · overheatedOVEN OVERHEATED. REPLACED OVEN, SYSTEM CHECKS NORMAL.SDR C2XA01CL089Receptacle · burnedYYZ FLIGHT 3898 THE CREW REPORTED A BURNING SMELL FROM THE LEFT COFFEE JUG. MAINTENANCE REPLACED THE LEFT COFFEE JUG RECEPTACLE CONNECTOR. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR DL757010666Bracket · failedDURING CRUISE SMOKE/ELECTRICAL ODORS FILLED MID CABIN. FLT DIVERTED INTO LNK ENROUTE TO DEN. FOUND MID GALLEY COFFEE MAKER TO BE SOURCE OF SMOKE. THE BRACKET THAT HOLDS THE HEATER COIL TO THE HOT PLATE FAILED ALLOWING THE COIL TO DROP INTO THE DRIP PAN. THE PLSDR DL76L010664Coffeemaker · defectiveFIRST CLASS COFFEE MAKER HAS BURING PLASTIC ODOR.REPLACED FWD GALLEY NR 1 COFFEEMAKER. OPS CKS GOOD NO ODOR NOTICED.SDR DL76L010659Smoke · detectedODOR OF BURNING PLASTIC/ELEC. SMOKE SEEMED TO COME FROM FWD GALLEY CEILING. PULL ALL FWD GALLEY C/B. ODOR DISAPPEARED IN ABOUT TEN MINUTES. PUSH C/B BACK IN. NO SMELL NOTED. A/C OK FOR SVC.SDR DLM11010653Fan · malfunctionedIR- AFTER LANDING LAV SMOKE ANNUNCIATES FOR 10 SECONDS WITH HIGH PITCED TONE IN 4R LAV. INSPECTED 4R LAV. NO EVIDENCE OF SMOKE. HIGH PITCHED WHINE FOUND TO BE AFT GALLEY CHILLER VENT FAN. PULLED AND COLLARD C/B FWD TO MCO AND PLACARDED.SDR QXEA0100493Pseu · defectiveSEA - AN ELECTRICAL TYPE SMELL WAS NOTED IN THE GALLEY. FOUND SMELL TO BE FROM A DEFECTIVE PSEU. REMOVED AND REPLACED PSEU. COMPLIED WITH BITE TEST. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR DLM11010597Coffeemaker · shortedMID GALLEY COFEEMAKER SHORTED OUT. (283) VISIBLE SPARKS FLEW, C/B POPPED. REPLACED COFFEEMAKERSDR 0101356633Smoke · detectedDURING CRUISE, NOTICED WHITE SMOKE AND ELECTRICAL SMELL COMING FROM THE NR 2 COFFEEMAKER IN NR 1 GALLEY. SMOKE AND SMELL DIMINISHED AFTER PULLING THE GALLEY CIRCUIT BREAKERS. MAINTENANCE COLLARED THE CIRCUIT BREAKER. LOG PAGE CURRENTLY DEFERRED FOR ADDITIONSDR CA010511028Heater · failed(CAN) DURING FLIGHT, SMOKE WAS OBSERVED COMING FROM FORWARD GALLEY NR 2 BOILER. ALL CB PULLED & GALLEY POWER SHEDDED. NO MORE SMOKE OBSERVED & FLIGHT CONTINUED WITHOUT INCIDENT. NR 2 WATER BOILER CHANGED IAW MM 25-30 & CHECKED SERVICEABLE. NO FURTHER INCIDENT
Back to JASC 2530