Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM11010563Oven · smokeOVENS IN AFT GALLEY STARTED TO SMOKE. OVENS CLEANED AND OPERATED FOR 15 MINUTES. CHECKS OKSDR CA010510015Oven · smoke(CAN) ONE GALLEY UNIT STARTED SMOKING AFTER TAKEOFF. J CLASS OVEN 5877 TURNED OFF.FOUND FOOD SPILLED ON ELEMENT. OVEN CLEANED, FUNCTIONAL CHECK CARRIED OUT NIL FAULT.SDR DLM11010549Compressor · overheatedPRIOR TO DEPARTURE FWD GALLEY CHILLER COMPRESSOR MAKING VERY LOUD NOISE AND GETTING WARM HOT / SMOKE - REPLACED CHILLER.SDR DL777010528Coffeemaker · shortedREAR COFFEE MAKER SHORTED OUT REPLACED DISPENSER.SDR DL76L010526Fan · failedABOUT 2 HOURS INTO FLT. THERE WAS A SLIGHT ACRID SMELL IN THE COCKPIT. RECIRC FANS WERE TURNED OFF ,SMELL STOPPED. WHILE TROUBLE SHOOTING FOUND THAT SMELL WAS NO LONGER PRESENT WITH FWD GALLEY POWER OFF. INSPECTED FWD GALLEY AREA & LOWER COCKPIT FLOORSDR CA010426008Terminal Block · melted(CAN) THE FORWARD GALLEY OVENS WERE FOUND TO BE INOPERATIVE BY THE FLIGHT ATENDANTS ON THE FLIGHT. THE ENGINEERS TROUBLESHOOTING THE DEFECT FOUND FWD GALLEY FEEDER D BREAKER POPPED. FURTHER INVESTIGATION FOUND TERMINAL BLOCK 2752VT STUD 8 MELTED, AND THE TERMISDR AALA20010649Coffeemaker · sparksLHR - DURING OVERNIGHT MAINTENANCE, AFT GALLEY COFFEEMAKER WHEN FIRST TURNED ON SPARKS APPEARED. REPLACED AFT GALLEY COFFEEMAKER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR USAASB01091Coffeemaker · shortedMIA - FLT 1191 - EN ROUTE FROM CLT-MIA, FLIGHT ATTENDANT REPORTED A SCORCHING SMELL IN THE FORWARD GALLEY APPROXIMATELY TEN MINUTES BEFORE LANDING AT MIA. OVENS WERE NOT IN USE AT THE TIME. COFFEE MAKER CIRCUIT BREAKERS WERE ALL PULLED AND GALLEY POWER WAS TSDR DLM11010493Oven · odorFLT ATT NOTIFIED CREW SMOKE SMELL IN AFT GALLEY. TURNED GALLEY POWER OFF. SMELL CONTINUED SMOKE DISAPEARED. ACTIVATED CABIN BUS SWITCH TO OFF POSITION. FIRE SERVICE INSPECTED AREA ABOVE AFT GALLEY WITH THERMAL IMAGE DEVICE. NIL HOT SPOTS / DAMAGE NOTED.AREA ALSDR AALA20010570Oven · dirtyLHR - FLT 0092 - EN ROUTE EWR-LHR, DETECTED SMOKE AT BUSINESS CLASS OVEN. TURNED OFF OVEN. LANDED LHR WITHOUT FURTHER INCIDENT. CLEANED BUSINESS CLASS OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR C2XA01IA172Receptacle · burnedIAH-FLIGHT ATTENDANT REPORTED BURNT SMELL IN CABIN DURING DESENT AND FOR REMAINDER OF THE FLIGHT. MAINTENANCE REMOVED AND REPLACED THE HOT JUG RECEPTACLE, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR DLM11010441Oven · smokeOVEN MID GALLEY RIGHT SIDE PRODUCES HEAVY SMOKE-MAYBE SPILLED FOOD. CABIN SERVICE CLEANED SPILLED FOOD FROM INTERIOR OF OVEN HEATED OVEN 15 MIN. NO SMOKESDR DL72S010429Oven · inoperativeAIR-TURN-BACK DUE TO ELECTRICAL BURNING SMELL IN FWD GALLEY AREA. SLC MECHANIC FOUND FWD GALLEY OVEN TO BE THE CAUSE. REPLACED GALLEY OVEN.SDR 2001UALA00254Oven · smokeSMOKE SMELL IN THE GALLEY. SUPPLEMENTAL DATA UPDATE OVENS R41 AND R42 WERE CLEANED OF DEBRIS. OPS CHECKED GOOD. NO FURTHER INCIDENTS.SDR QXEA0100309Post · improperYYC-AFT GALLEY CENTER FREIGHT POST LOWER ATTACHMENT TO FLOOR STRUCTURE IN NON CONFORMANCE, ALSO LOWER END OF FREIGHT POST IS IN CONTACT WITH GUSTLOCK CABLE RUN. REPAIRED IAW HORIZON AIR EA 4-53-1457.SDR DLL10010397Oven · overheatedTWO PBES USED DUE SMOKE FROM OVERTEMP OVENS IN LOWER GALLEY- PLS REPLACE PBES ATL MAINT F/A TOOK 2 CABIN PBES TO LOWER GALLEY PLS CHECK ALL PBES FOR PROPER LOCATION. CA-AS PER F/A VERBAL OVENS ON FOR EXTENDED PERIOD DUE TO FROZEN MEALS. INSPECTED OVENS SDR 2001UALA00222Oven · overheatedSMOKE IN GALLEY. SUPPLEMENTAL DATA UPDATE GALLEY OVEN ADJACENT TO DOOR 1R OVERHEATED & EMITTED SMOKE. ELECTRICAL HOOK-UPS CHECKED AND FOUND NORMAL. GALLEY OVEN TAGGED UNSERVICEABLE AND REPLACED. SUBSEQUENT OVENS NOW CHECK NORMAL.SDR C2XA01CL052Receptacle · burnedCLE FLIGHT 3992 THE CREW REPORTED A BURNING SMELL IN THE GALLEY. MAINTENANCE INSPECTED AND REPLACED THE OUTBOARD HOT JUG RECEPTACLE. OPERATIONAL CHECKS WERE GOOD. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR QXEA0100250Receptacle · defectiveSMF- ELECTRICAL SMELL IN GALLEY. NR 1 COFFEE CIRCUIT BREAKER POPPED. REMOVED AND REPLACED NR 1 HOT JUG RECEPTICAL. INSPECTED, CLEANED AND LUBED NR 2 RECEPTICAL. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR QXEA0100249Coffeemaker · malfunctionedPDX- NR 1 COFFEE POT CIRCUIT BREAKER POPPED. F/A REPORTED SLIGHT ELECTRICAL SMELL. REMOVED AND REPLACED NR 1 COFFEE POT. RESET CIRCUIT BREAKER. OPERATIONAL CHECK GOOD, AIRCRAFT RETURNED TO SERVICE.SDR 2001UALA00180Oven · contaminatedCABIN CREW REPORT FLAMES IN FORWARD GALLEY. SUPPLEMENTAL DATA UPDATE FLAMES IN GALLEY OVEN CAUSED BY PAPER STUCK IN VENT. REPLACED OVEN. NO DAMAGE TO AIRCRAFT.SDR DLM11010359Oven · overheatedBULKHEAD NEXT TO G-7 GALLEY IS CHARRED, OTHER AREAS SHOW BURN DAMAGE. VISUAL INSPECTED AFT GALLEY AREA FOUND OVEN 327 AND 328 DUAL OVEN SHOWED BURN. OTHER AREA NO ABNORMALITY OBSERVED. SUSPECT OVEN PROBLEM. OVEN 327 AND 328 REPLACED.SDR AU010201Oven · burned(AUS) REAR GALLEY OVEN FAN MOTOR BURNT.SDR DL733010328Oven · malfunctionedFWD OVEN HAD AN ELECTRICAL /BURNT SMELL. GALLEY PWR WAS REMOVED, CONDITION IMPROVED. REPLACED FWD GALLEY OVEN AND BOTH CONTROLLERS. OVEN DPN 255701023, S/N 98-12-0066, CONTROL DPN 255701024, S/N OFF 8601-0701 & 8612-1728.SDR C1HA200193003Wire · detachedFLIGHT ATTENDENT SMELLED SMOKE IN AFT GALLEY ON APPROACH INTO PUJ. UPON LANDING FOUND A WIRE HANGING IN AFT GALLEY COMPARTMENT BELOW COFFEEMAKER. FOUND WIRE PULLED OFF HOT PLATE TERMINAL REPAIRED WIRE, OPS CHECKED NORMAL.SDR DLM88010281Odor · detectedDURING DESCENT AT 2500 FT SMELLED STRONG ELECTRICAL BURNING ODOR. CONFIRMED BY F/A IN AFT OF A/C. TURNED OFF GALLEY PWR AS PRECAUTION AND SMELL DISSIPATED. MTC INSPD TAIL COMPRT-BAG BINS-CBN-POWERED ALL GALLEY EQUIP AND INSPD CB PNL BEHIND CAPT SEAT AND E/ESDR DLM11010277Chiller · overheatedMCO MID GALLEY G-4 CHILLER INOP. DUE REPORTS OF ELECTRICAL SMELL INSPECT CHILLER WIRING INSTALLATION FOR SIGNS OF OVERHEATING / CHAFING / ETC. INSPECTED WIRING INSTALLATION, NO TROUBLE FOUND. CHILLER ITSELF HAS A STRONG ELECTRICAL SMELL. SHOP INSPECTION RESDR DL757010276Coffeemaker · dirtyBURNING ODOR COMING FROM R AFT GALLEY COFFEEMAKER. FOUND HEAVY COFFEE DEPOSITS ON HEATING PAN. CLEANED PAN AND ODOR WAS NO LONGER DETECTED DEACTIVATED UNIT AS A PRECAUTIONARY ACTION C/B COLLARDED. UNIT WAS NOT REPLACED, NOT IN STOCK AT THIS TIME.SDR C2XA01BT012Connector · faultyEWR - FLT 4088 - CREW REPORTED BURNING SMELL FROM COFFEE CONNECTOR NR 2 POSITION. MAINTENANCE REMOVED AND REPLACED NR 2 COFFEE POT CONNECTOR IAW EMB145AMM NR 25-16-02, OPS CHECKED GOOD. (M)SDR AALA20010228Oven · defectiveLHR - FLT 91 - EN ROUTE LHR-ORD, DETECTED SMOKE AT NR 2 GALLEY. NR 2 OVEN CIRCUIT BREAKER PULLED. LANDED ORD WITHOUT FURTHER INCIDENT. REPLACED NR 2 GALLEY OVEN AND RESET CIRCUIT BREAKER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 2001UALA00081Cart · shortedENTRY CART 300 IN MID-GALLEY SPARKED WHEN PLUGGED IN AND THE 60 AMP AC CB POPPED. OK AT FIRST SERVICE OF FLIGHT. LEFT UNPLUGGED AND DID NOT RESET. *S/D* CART CONTROL PANEL HAD SHORT TO GROUND. TAGGED CART AND NOTIFIED DOBBS FOOD SERVICE. RESET 15 AMP CIRCSDR USAASA01003Oven · fireCLT-LGA- FLT 1886 - AFTER DEPARTING CLT, AND CLIMBING THROUGH FL170,FIRE WAS REPORTED TO BE COMING FROM THE FORWARD GALLEY OVEN. THE FIRE WAS EXTINGUISHED USING A PORTABLE FIRE EXTINGUISHER. THE FLIGHT RETURNED TO CLT AND LANDED WITHOUT INCIDENT. MAINTENANCSDR 0100286311Oven · contaminatedDURING CRUISE, NOTICED A STRONG ELECTRICAL SMELL IN UPPER DECK GALLEY AND DIMINISHED WHEN LIGHTS WERE TURNED OFF. MAINTENANCE INSPECTED AREA AND FOUND PLASTIC MELTED ON NR 2 OVEN. CLEANED AND REMOVED RESIDUE. OPERATIONAL CHECK NORMAL.SDR AT0100040Coffeemaker · odorFOUND ACRID BURNING SMELL IN COCKPIT AND FORWARD FLIGHT ATTENDANT STATION. FOUND BURNT COFFEE GROUNDS ON FORWARD COFFEE MAKER. CLEANED BURNT GROUNDS, NO SMELL NOTED. ALSO CHECKED E&E COMPARTMENT, FORWARD CARGO COMPARTMENT AND FORWARD FLIGHT ATTENDANT STATIOSDR DLM11010158Chiller · malfunctionedSTRONG ELECTRICAL SMOKE SMELL REPORTED IN AREA OF BC GALLEY ODOR REPORTED BY PAX AND CREW. MID GALLEY A/C AND D/C CIRCUIT BREAKERS PULLED AND COLLARD FOUND CHILLER CYCLING ON AND OFF. CHILLER FWD TO MCO AND PLAC PER MEL 25-22-01. DUE TO CREW REPORTS OF CHILSDR SIMA0251Coffeemaker · malfunctionedLAX - FLT 3113 - CREW REPORTED AN ELECTRICAL SMELL AFTER TAKEOFF. NO SMOKE WAS OBSERVED AND SMELL APPEARED TO BE COMING FROM THE GALLEY AREA. REMOVED AND REPLACED HOT JUG CONTAINERS IAW SAAB AMM 25-32. OPS CHECK GOOD. (M)SDR SIMA0253Coffeemaker · inoperativeHOU - FLT 3401 - CREW REPORTED A BURNING ORDER IN FLIGHT WITH NO SMOKE REPORTED. CREW ALSO REPORTED CIRCUIT BREAKER M25 POPPED. FORWARD HOT JUG WAS PUT ON MEL. FORWARD HOT JUG WAS REPLACED, OPERATIONAL CHECK WAS GOOD MEL WAS CLEARED. (M)SDR 2001UALA00053Oven · contaminatedSMALL FLAME AND SMOKE IN FORWARD CABIN OVEN FROM PAPER WRAPPER. CIRCUIT BREAKER PULLED AND FIRE EXTINGUISHER USED.SDR DL738010102Oven · overheatedGALLEY 1R OVEN OVERHEATS. LITE SMOKE OBSERVED FROM OVEN. TURNED OFF OVEN AND PULLED C/B. REPLACED OVEN.SDR AALA20010082Coffeemaker · defectiveSJU - FLT 1574 - EN ROUTE SJU-BOS - DETECTED SMELL AND SMOKE IN CABIN. RETURNED SJU AND LANDED WITHOUT FURTHER INCIDENT. REPLACED NR 3 COFFEEMAKER. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR QXEA0100017Connector · malfunctionedSEA-ELECTRICAL BURNING SMELL COMING FROM COFFEE URN LOCATION TOP AND BOTTOM. REMOVED AND REPLACED BOTH UPPER AND LOWER COFFEE JUG ELECTRICAL RECEPTICALS. OPERATIONAL WARM-UP CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR SIMA200101204Connector · burnedFAT- FLT 3105 - CREW REPORTED A STRONG BURNED PLASTIC SMELL DURING DESCENT INTO FAT. MAINTENANCE FOUND HOT JUG RECEPTICLE BURNED. HOT JUGS PUT ON MEL AT THIS TIME. MAINTENANCE REPLACED AIRFRAME CONNECTOR FOR THE HOT JUGS. AIRCRAFT WAS RETURNED TO SERVICE. SDR VNAA0101009Connector · shortedTHIRTY MINUTES INTO THE FLIGHT, THE FLIGHT ATTENDANT INFORMED THE CAPTAIN THAT THERE WAS A ELECTRICAL SMELL IN THE GALLEY. THE FIRST OFFICER WENT BACK AND CONFIRMED THIS. THE CREW INFORMED DISPATCH THAT THEY WERE RETURNING TO PIT. THE CREW WAS ADVISED TO GOSDR DL76L010025Coffeemaker · dirtyAFT COFFEEMAKER SMELLS OF BURNING ODOR. COFFEEMAKER AND AREA CLEANED PULLED C/B AND FWD TO MCO.SDR AU010032Connector · damaged(AUS) LIQUID HEATER CONNECTORS DAMAGED DUE TO OVERHEATING.SDR AU010031Connector · damaged(AUS) LIQUID HEATER CONNECTORS DAMAGED DUE TO OVERHEATING.SDR SIMA00311Coffeemaker · malfunctionedCMH - FLT 4039 - CREW REPORTED THREE BREAKERS IN THE GALLEY POPPED IN FLIGHT FOLLOWED BY A SMOKE ODOR IN THE COFFEE HOT JUG AREA. SEVERAL MINUTES LATER THE EMERGENCY LIGHTS CAME ON AND THE CABIN LIGHTS FLICKERED. AIRCRAFT WAS LANDED WITH NO FURTHER INCIDENTSSDR AALA20002139Oven · dirtyLHR - FLT 156 - DURING FLIGHT, AFT GALLEY LEFT OVEN SMOKES. CONTINUED FLIGHT WITHOUT INCIDENT. CLEANED OVEN. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR TWAA0019902Coffeemaker · faultyCOFFEE MAKER NUMBER 6 WAS EMITTING A BURNED WIRE SMELL. CREW TURNED OFF THE COFFEE MAKER. MAINTENANCE REPLACED IT. CHECK-C 9-10-00 MCI.SDR TWAA0019801Oven · burnedSMOKE WAS COMING FROM BEHIND THE NUMBER 2 OVEN IN THE FORWARD GALLEY. CREW PULLED THE OVEN CIRCUIT BREAKERS. FOUND OVEN FAN MOTOR BURNED. REPLACED THE OVEN. CHECK-C 11-2-00 LAX.
Back to JASC 2530