Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLL19000772Filter · dirtyREPEAT ITEM - ELECTRICAL BURNING ODOR, REAR OF A/C DURING TAXI INTO OGG. NO SMOKE NOTED. OPERATED ALL SYS FANS AND GALLEY. NO ELEC BURNING ODOR FOUND. FOUND FW GALLEY CHILLER OVERHEAT LIGHT ON. CLEANED CHILLER FILTER.SDR 2000UALA00195Oven · smokeOVEN IN 1ST CLASS STARTED SMOKING INTERNALLY. NO FIRE OR FLAMEOBSERVED. USED HALON AND WATER EXTINGUISHER INSIDE OVEN. ALL CB''S PULLEDFOR THAT GALLEY AREA PRECAUTIONARY. DID NOT APPEAR TO BE ELECTRICPROBLEM. MAY HAVE BEEN OBJECTS INSIDE. *S/D* SUSPECT SDR USAAD00052Coffeemaker · malfunctionedPHL-DTW - FLT 1164 - IN FLIGHT, A BURNING SMELL CAME FROM GALLEY AREA. THE GALLEY POWER WAS TURNED OFF AND WAS TURNED BACK ON AGAIN ONCE ON THE GROUND. NO SMELL UNTIL THE COFFEE MAKER WAS TURNED ON. SMOKE THEN CAME OUT FROM BELOW COFFEE MAKER. POWER WAS TUSDR DL76L000708Oven · smokeAFT GALLEY TOP OVEN RT SIDE SMOKES IN FAN AREA WITH POWER ON, SMOKE DISSIPATES WITH POWER OFF. REPLACED OVEN.SDR 2000UALA00181Oven · smokeRETURNED TO DEN DUE TO SMOKE SMELL IN CABIN FROM AFT GALLEY. *S/D* CABIN SMELL DUE TO MALFUNCTIONING AFT GALLEY UNIT. REPLACED AFT HOT UNIT. ALL CHECKS NORMAL NOW.SDR 2000UALA00176Coffeemaker · smokeF/A REPORTS ACRID SMOKE SMELL IN AFT GALLEY. STRONGEST AROUND EYEBALL VENT. *S/D* FOUND ELECTRICAL SMELL COMING FROM RIGHT AFT COFFEEMAKER. REPLACED COFFEEMAKER (P/N:3510 0032 01U2). OPERATIONAL CHECK NORMAL.SDR QXEA0000933Coffeemaker · failedSEA- COFFEE BURNER SEEM TO CAUSE BURNING SMELL. REMOVED AND REPLACED BAD COFFEE JUG FROM NR 2 HOLDER. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR QXEA0000931Receptacle · failedSEA- COFFEE WARMER CIRCUIT BREAKER POPPED AGAIN WITH A STRONG ELECTRICAL CORD SMELL. REMOVED AND REPLACED LOWER COFFEE WARMER RECEPTICAL, OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR AALA20000608Coffeemaker · defectiveLHR - FLT 0155 - EN ROUTE LHR/BOS WHILE AT GATE NR 10, COFFEE MAKER EMITTED SPARKS. REPLACED NR 10 COFFEE MAKER AND RESET CIRCUIT BREAKER. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR AWXA0000228Oven · smokeAFT GALLEY NR 2 OVEN HAS STRONG ELECTRICAL INSULATION BURNING SMELL. DPI ISSUED MEL 25-22-03 COND 1 CONT NR 127673.SDR QXEA0000927Receptacle · failedGEG- UPPER MAPCO SMELLS LIKE AMONNIA WHEN TURNED ON. REMOVED AND REPLACED COFFEE WARMER RECEPTICLE THAT WAS BURNT. OPERATIONAL CHECK GOOD. AIRCRAFT RETURNED TO SERVICE.SDR AALA20000486Oven · contaminatedLHR - FLT 106 - DURING FLIGHT, NR 1 OVEN HAD SMOKE WHEN TURNED ON. LANDED LHR WITHOUT INCIDENT. CLEANED OVEN. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR AALA20000492Oven · odorNRT - FLT 153 - FOUR HOURS INTO FLIGHT, COMPARTMENT ONE OVEN NR 3 HAD ELECTRICAL BURNING SMELL. TURNED OVEN OFF FOR REST OF FLIGHT AND LANDED NRT WITHOUT INCIDENT. PERFORMED CHECK OUT AND COULD NOT DUPLICATE SMELL. SYSTEM GROUND CHECK NORMAL OPERATION. (M)SDR CALA0000339Oven · inoperativeSMOKE APPEARED IN THE AFT CABIN SHORTLY AFTER TAKEOFF FROM SDQ. THE CIRCUIT BREAKER FOR THE NR 3 OVEN IN AFT GALLEY WAS PULLED AND THE SMOKE CEASED. THE AIRCRAFT WAS RETURNED TO SDQ WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 3 OVEN AT FAULT.SDR AU000380Heater · failed(AUS) WATER HEATERS (2OFF) BURNT AND ELEMENTS EXPOSED. TWO OTHER WATERHEATERS WERE IN POOR CONDITION.SDR QXEA0000757Coffeemaker · malfunctionedSEA- OXIDATION SMELL COMING FROM GALLEY. REPLACED COFFEE CONTAINER. OPERATIONAL CHECKS GOOD. AIRCRAFT RETURNED TO SERVICE.SDR AT0000151Panel · corrodedDURING A SCHEDULED INSPECTION AT TIMCO IN LAKE CITY FL, FOUND GALLEY LOWER COMPARTMENT PANEL CORRODED. AFTER BLENDING MATERIAL FOUND TO BE OUT OF LIMITS. CORRECTIVE ACTION: FABRICATED AND INSTALLED GALLEY PANEL IAW DC9 SRM 53-05, 51-10-03, 51-10-04, AND SDR AWXA0000123Oven · contaminatedAFTER TURNING ON OVEN NR 9 F/A SMELLED SMOKE. REMOVED OVEN INSERT AND FOUND A PAPER BAG BURNING. REMOVED PAPER AND EXTINGUISHED WITH WATER. NO EMERGENGY ACTIONS.SDR UIEA0009Harness · damagedON REMOVAL OF OVEN B/E AEROSPACE TYPE DF400PTC, FOUND CONNECTING POWER SUPPLY FLEX CABLE TEFLON SPIRAL WRAP MELTED DUE CONTACTING HOUSING OF HOT AIR CIRCULATING FAN. WIRE BUNDLE WAS PREVIOUSLY REPAIRED AS INDICATED BY WIRE SPLICES. BUNDLE IS APPROX 3 FT IN LSDR 2000UALA00109Coffeemaker · smokeAFT GALLEY COFFEEMAKER SMOKING AND SPARKING. *S/D* INSPECTED AREA WITH COFFEEMAKER ON, NO PROBLEMS. INSPECTED COFFEEMAKER AND MATING RECEPTACLE FOR SIGNS OF ARCING. CLEANED WET AREA AROUND COFFEEMAKER, NO CHAFING OR ARCING NOTED. REPLACED COFFEEMAKER PRECSDR AALA20000399Oven · smokeLHR - FLT 90 - DURING FLIGHT, FIRST CLASS OVEN NR 2 INOPERATIVE. FAN WOULD NOT TURN. SMOKE CAME FROM EXHAUST AND CIRCUIT BREAKER DID NOT POP OR OPEN. MANUALLY PULLED OUT. CONTINUED FLIGHT AND LANDED LHR WITHOUT INCIDENT. REPLACED OVEN. SYSTEM GROUND CHECSDR C2XA00IA043Connector · failedIAH - FLT 4180 - AFTER LANDING, THE FLIGHT ATTENDANT REPORTED A HEAVY BURNING SMELL IN THE GALLEY AREA. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED A SHORTED HOT JUG CONNECTOR, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE. (M)SDR CA000320020Circuit Breaker · failed(CAN) VERY STRONG SMELL OF SMOKE AFTER TAKEOFF FROM GALLEY AREA. DECLARED EMER AND RETURNED TO GATE. FOUND NR 1 COFFEE MAKER 10 AMP CB AT FAULT AND REPLACED.SDR SWAA000298Coffee Maker · inoperativeELECTRICAL SMOKE AND SMELL DETECTED IN AFT GALLEY WORK AREA. FOUND NR 1 COFFEEMAKER INOP. REMOVED AND REPLACED COFFEEMAKER PER MM.SDR 2000UALA00076Oven · contaminatedFLIGHT ENCOUNTERED SMOKE FROM AFT OVEN AREA. CREW SHUT OFF AFT OVENS, COOLED THEM, REMOVED CONTENTS, SMOKE AND ODOR DISSIPATED. NO CIRCUIT BREAKERS POPPED. *S/D* GREASE AND BURNED FOOD. OVENS WERE REPLACED AFTER THE FLIGHT AND SENT TO THE SHOP FOR CLEANINSDR ABXA000109Water Heater · malfunctionedELECTRICAL BURNING SMELL WAS COMING FROM THE HOT WATER MAKER SHORTLY AFTER IT WAS TURNED ON. WATER WAS FULL, AFTER TURNING IT OFF THE SMELL WENT AWAY. REPLACED THE HOT CUP BRACKET AND HOT CUP IAW DC8 MM. OPS CHECKED GOOD.SDR CA000301009Coffeemaker · overheated(CAN) DURING CLIMB CREW REPORTED SMELL OF SMOKE IN BACK OF MAIN CABIN, A/C RETURNED. COFFEEMAKER OVERHEATED AND REPLACED.SDR CA000215020Connector · damaged(CAN) FLIGHT ATTENDANT REPORTED SMOKE IN AFT GALLEY. THROUGH INVESTIGATION REVEALED DAMAGED PINS IN THE CONNECTOR FOR THE TRASH COMPACTOR. CONNECTOR REPAIRED.SDR CA000215033Wire · contaminated(CAN) OVEN REPORTED NOT WORKING. PHASE 1 WIRE DAMAGED DUE TO WATER CONTACT. WIRE REPAIRED AND COUNTER RESEALED. INSPECTION EVERY A-CHECK IMPLEMENTED.SDR SWAA000231Coffeemaker · malfunctionedBURNING SMELL DURING FLIGHT IN AFT GALLEY, TURNED COFFEEMAKERS OFF AND SMELL DISAPEARED. PULLED AND COLLARED AFT GALLEY LOWER COFFEEMAKER C/B AND CONTINUED PER MX NOTE. LATER AT MDW RESEATED LOWER COFFEEMAKER CONNECTOR. RESET C/B AND OPS CHECK GOOD PER MM.SDR USAASA00005Oven · contaminatedPIT-LAX - FLT 5 - EN ROUTE THE CREW REPORTED AN ELECTRICAL SMELL AND THE SMELL OF MELTING PLASTIC IN THE FORWARD GALLEY. THE AIRCRAFT RETURNED TO THE FIELD AND LANDED WITHOUT INCIDENT. MAINTENANCE REPLACED THE FORWARD OVEN FOR PLASTIC ON THE HEATING ELEMENT,SDR AU000942Plug · burned(AUS) AFT GALLEY NR 3 OVEN TIMER POWER PINS BURNT AT TIMER MODULE PLUG.SDR DLL10000266Oven · fireBURNING IN LOWER GALLEY, FOOD LEFT IN OVEN. HALON BOTTLES USED ALONG WITH PBE-S BY FLT ATTN. ALL WAS CONTAINED IN OVEN. REMOVED REMAINS FROM OVEN. OVEN IS SERVICEABLE AND WORKS NORMAL.SDR AU000047Oven · failed(AUS) FORWARD GALLEY OVEN FAN MOTOR BURNT DUE TO OVEN RACK FOULING FAN.SDR IXXA0000006Coffee Maker · malfunctionedSJC - FLT 834 - EN ROUTE FROM TOL TO SJC, SMOKE WAS SIGHTED EMITTING FROM THE FORWARD GALLEY HOT CUP ASSEMBLY. THE FLIGHT CREW SECURED THE ELECTRICAL POWER TO THE HOT CUP AND THE FLIGHT CONTINUED TO SJC. MAINTENANCE INSPECTED AND CONFIRMED A DEFECTIVE HOT CUSDR QXEA0000236Warmer · malfunctionedPDX - BURNT ELECTRICAL ODOR COMING FROM LOWER BEVERAGE WARMER. SYSTEM DEACTIVATED. ODOR DISSAPATED. SYSTEM PLACED ON DEFFERED MAINTENANCE LIST. AIRCRAFT RETURNED TO SERVICE.SDR AALA20000184Oven · dirtyDFW - FLT 490 - AFTER TAKEOFF ELECTRICAL SMOKE SMELL REPORTED IN AFT CABIN BY FLIGHT ATTENDANT. RETURNED AND LANDED DFW WITHOUT FURTHER INCIDENT. REPLACED OVEN. GROUND CHECK NORMAL OPERATION. (M)SDR DL73K000220Coffeemaker · malfunctionedDURING TAXI IN, NOTICED ELECTRICAL FUMES. FUMES SEEMED TO BE COMING FROM CB PANEL BEHIND F/O SEAT. ALSO, NOTICED BT LEAD. FLIGHT ATTENDANT FOUND R1 GALLEY COFFEEMAKER OVERHEATING. REPLACED SAME, PERFORMED OPS AND CHECK ALL OK. INSPECTED ALL CB PANELS AND SDR MWEA00035Oven · smokeRIGHT HAND GALLEY STARTED TO SMOKE DURING FLIGHT. FLIGHT ATTENDANT TURNED OFF OVEN AND SMOKE IMMEDIATELY STOPPED. MTC CHECKED AND RAN OVENS FOR SEVERAL MINUTES, NO SMOKE OR SMELLS OF SMOKE WERE NOTED.SDR CA000128008Coffeemaker · odor(CAN) ON APPROACH ELECTRICAL SMELL IN AFT GALLEY, ERS AVAILABLE, ONE MINUTE LATER SMOKE DISIPATED, COFFEEMAKER TOO HOT TO TOUCH, CB HAD POPPED. COFFEEMAKER REPLACED. MAINT INDICATED WATER SENSOR AND RELAY REPLACED IN COFFEEMAKER.SDR DLM11000186Coffeemaker · malfunctionedMID GALLEY COFFEMAKER WIRE BURNED THROUGH, BUT DID NOT OPEN CIRCUIT BREAKER. VERIFIED WITH FLITE CREW AND CABIN CREW AND NO SMOKE DETECTED. FOUND C/B POP AT COFFEEMAKER. VERIFIED A/C CIRCUIT BREAKER ON CONTROL PANEL DID NOT OPEN, INSPECTED AIRCRAFT WIRING. SDR USAAD00012Oven · failedLGA-FLL - FLT 2347 - DURING CRUISE, THE GALLEY OVEN STARTED SMOKING. THE AIRCRAFT DIVERTED TO RIC AND LANDED WITHOUT INCIDENT. MAINTENANCE OPENED THE CIRCUIT BREAKERS TO THE FORWARD GALLEY OVEN AND DISCONNECTED THE ELECTRICAL CONNECTOR TO THE OVEN. AN OVERWSDR CA000209045Receptacle · failed(CAN) DURING TAXI BURNING SMELL NOTED AND TRACED TO GALLEY OVEN. A/C RETURNED. GALLEY OVEN RECEPTACLE AT FAULT REPLACED.SDR CALA9901740Oven · inoperativeTHE NR 2 OVEN IN FORWARD GALLEY BEGAN TO PRODUCE SMOKE WITH AN ELECTRICAL ODOR WHILE EN ROUTE TO IAH. THE OVEN CIRCUIT BREAKER WAS PULLED AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED TO IAH WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND NO EVIDENCE OF FIRE. SDR CA000209038Chiller · failed(CAN) ON PREFLIGHT SMOKE COMING FROM REAR GALLEY AND BEGAN TO FILL CABIN PASS DEPLANED. DEACTIVATED BOTH CHILLERS AND REPLACED.SDR DLM88992824Oven · dirtyFWD GALLEY OVEN BEGAN TO SMOKE AND EMIT AUDIBLE CRACKLE AFTER T/O. CONTINUED WITH C/B PULLED AND GALLEY POWER OFF. REPLACED OVEN.SDR CALA9901719Oven · inoperativeSMOKE BEGAN COMING OUT OF THE AFT GALLEY OVEN CONTROL PANEL WHILE EN ROUTE TO EWR. THE SMOKE STOPPED WHEN OVEN WAS TURNED OFF. THE FLIGHT CONTINUED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND NO EVIDENCE OF FIRE. THE AFT GALLEY OVEN WAS REMOVED AND REPLACEDSDR CA000110085Coffeemaker · shorted(CAN) FLIGHT ATTENDANT REPORTED RECIEVING AN ELECTRICAL SHOCK FROM COFFEEMAKER. COFFEEMAKER REPLACED.SDR CA000110090Oven · smoke(CAN) DURING TAKEOFF, OVEN IN REAR GALLEY BEGAN TO SMOKE, OVEN DEACTIVATED, OVEN REPLACED.SDR 99UAL900659Oven · fireOVEN FIRE IN FLIGHT. DISCHARGED HALON EXTINGUISHER. *S/D* PAPER DEBRIS ON OVEN INSERT CAUSED SMALL FLAME-UP IN FLT. THE FIRE WAS EXTINGUISHED BY CREW USING HALON EXTINGUISHER. CHECKED OVEN AND GALLEY SURROUNDING AREA FOR DAMAGED, NO DAMAGE FOUND. CLEANED
Back to JASC 2530