JASC 2530

Service difficulty reports · 4,471

Reports filed under 2530 · Buffet/Galleys, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '2530'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR SWAA992065Coffeemaker · failedBURNING ELECTRICAL SMELL IN AFT GALLEY. SMELL COMING FROM UPPER COFFEE MAKER HEATING BLANKET WHICH HAD RESIDUAL MOISTURE. REMOVED MOISTURE FROM HEATING BLANKET. OPS CK GOOD.Dec 14, 1999 · N64SW · Boeing 7372H4SDR AALA991894Oven · dirtyLHR - FLT 136 - DURING FLIGHT FIRST CLASS OVEN SMOKES. CLEANED DEBRIS FROM FIRST CLASS OVEN. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Dec 13, 1999 · N379AA · Boeing 767323SDR CA991229011Coffeemaker · overheated(CAN) FLIGHT ATTENDANT REPORTED A BURNING/ELECTRICAL SMELL IN THE GALLEY AREA. LIGHTING AND GALLEY EQUIPMENT WAS SWITCHED OFF AND THE SMELL DISSIPATED. MAINTENANCE INVESTIGATION REVEALED THAT THE SMELL WAS COMING FROM THE COFFEE WARMER AND REPLACED IT.Dec 11, 1999 · Dhav DHC8102SDR CA991231018Circuit Breaker · tripped(CAN) IN CRUISE MILD ELECTRICAL SMELL IN GALLEY FOLLOWED BY COFFEE MAKER CB POPPING. REPLACED COFFEE MAKER.Dec 7, 1999 · Airbus A319114SDR AALA991849Oven · dirtyLHR - DURING OVERNIGHT MAINTENANCE, FIRST CLASS NR 2 OVEN SMOKED. CLEANED FIRST CLASS OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Dec 6, 1999 · N18066 · Airbus A300B4605RSDR AALA991848Oven · dirtyLHR - FLT 0106 - DURING OVERNIGHT MAINTNENANCE, FIRST CLASS NR 1 OVEN SMOKED. CLEANED FIRST CLASS OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)Dec 6, 1999 · N18066 · Airbus A300B4605RSDR DLL19992654Oven · dirtyINBOUND PILOT REPORT, OVENS IN ALL GALLEYS GET VERY HOT AND CREATE A LOT OF SMOKE THROUGHOUT A/C. OVENS NEED CLEANING TO REMOVE OLD FOOD. OVENS CLEANED BY CABIN SERVICE.Dec 5, 1999 · N767DA · Lkheed 10113853SDR 99UAL900631Oven · malfunctionedAIRCRAFT RETURNED TO BLOCKS, SPARKS IN AFT GALLEY OVEN AREA.Dec 4, 1999 · N613UA · Boeing 767222SDR DLM11992642Oven · contaminatedDURING FLIGHT, SMOKE WAS IN THE AFT SECTION OF THE A/C. TURNING OFF THE AFT GALLEY AND THE VCC/ADB SWITCH, SMOKE STOPPED. FOUND PLASTIC IN ONE OF THE OVENS CREATING ODOR.Dec 3, 1999 · N809DE · Doug MD11SDR CA991208047Receptacle · failed(CAN) ELECTRICAL BURNING SMELL REPORTED IN FORWARD GALLEY. INVESTIGATION REVEALED A BURNT RECEPTICAL ON THE COFFEE MAKER. RECEPTICAL REPLACED.Nov 30, 1999 · Bag BAE146200ASDR SIMA993321Sockets · damagedMIA - FLT 5401 - FLIGHT ATTENDANT REPORTS ODOR COMING FROM AN UNKNOWN SOURCE IN THE AFT CABIN. INSPECTED AND FOUND BOTH HOT CONTAINER SOCKETS TO BE DAMAGED. REMOVED AND REPLACED BOTH HOT CONTAINER SOCKETS AND BOTH HOT CONTAINERS. OPERATIONAL CHECK GOOD. AINov 28, 1999 · N327AT · Aerosp ATR42300SDR DL72S992601Oven · contaminatedFORWARD GALLEY WORK LIGHT C/B POPPED. F/A REPORTED LIGHT PLASTIC SMELL. NO SMOKE NOTED. BREAKER WAS NOT RESET. ON CHECK, FOUND GALLEY WORK LIGHT C/B POPPED AND COLLARED BY PREVIOUS ENG ORDER. CHKD OPS OF OVENS, COFFEEMAKER. ALL ELEC OPERATIONS NORMAL. FONov 25, 1999 · N403DA · Boeing 727232SDR CA991231033Receptacle · loose(CAN) FLIGHT ATTENDANT RECEIVED SHOCK FROM OVEN WHEN INSERTING OVEN IN TROLLY. OVEN OUTLET HANGING LOOSE AND MISSING PRONGS FROM PLUG. REPLACED.Nov 24, 1999 · Doug DC932SDR CA991208028Coffee Warmer · failed(CAN) THE FLIGHT CREW REPORTED AN ELECTRICAL SMELL IN THE CABIN DURING TAKEOFF AND RETURNED TO THE AIRPORT. MAINTENANCE INVESTIGATION REVEALED THE COFFEE WARMER TO BE MALFUNCTIONING AND REPLACED IT.Nov 23, 1999 · Dhav DHC8301SDR SIMA993263Socket · failedDFW - FLT 3663 - FLIGHT ATTENDANT REPORTS MILD BURNING ODOR IN THE GALLEY AREA. PULLED ALL THREE GALLEY CIRCUIT BREAKERS AND THE ODOR WENT AWAY. REMOVED AND REPLACED ONE AIRCRAFT SIDE HOT JUG SOCKET. AIRCRAFT RETURNED TO SERVICE. (M)Nov 22, 1999 · N616AE · Emb EMB145LRSDR 99ZZZX4431Food Warmer · shortON CLIMB-OUT, SMOKE NOTICED COMING FROM THE FOOD WARMER. THE PROBLEM WAS DETERMINED TO BE FLUID LEAKING FROM ONE OF THE HOT PLATES ON TO THE OVEN RAILS CAUSING THE BOTTOM RAIL TO SHORT TO GROUND. SUBMITTER STATED IF THE BOTTOM OF THE OVEN WAS MADE OF A NON-CNov 22, 1999 · N53M · Gulstm GIVSDR AALA991714Oven · dirtyLHR - DURING OVERNIGHT MAINTENANCE, FIRST CLASS NR 1 OVEN EMITS A STRONG BURNING ODOR. CLEANED FIRST CLASS NUMBER 1 OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 15, 1999 · N90070 · Airbus A300B4605RSDR DLM88992510Oven · dirtyELECTRICAL / PLASTIC FUMES. SUSPECTED SOURCE FORWARD GALLEY OVEN WAS NOT ON AT THE TIME. FOUND PLASTIC SHIPPING TAG STILL ON FWD GALLEY OVEN LINER. REMOVED LINER, RAN OVENS. CHECKS OK.Nov 14, 1999 · N985DL · Doug MD88SDR AALA991715Oven · dirtyIAD - FLT 775 - AFTER TAKEOFF FROM DCA, COCKPIT AND CABIN FILLED WITH SMOKE. DIVERTED AND LANDED IAD WITHOUT INCIDENT. REPLACED OVEN IN FIRST CLASS GALLEY. RAN APU AND ENGINE WITH BOTH PACKS IN FULL OPERATION. SYSTEM GROUND CHECK NORMAL OPERATION. (M)Nov 14, 1999 · N450AA · Doug DC982SDR DLM88992509Oven · dirtyIN FLIGHT FWD AND AFT OVENS GENERATED SMOKE WHEN USED. REMOVED FOOD CARRIER FROM FWD OVEN WITH INTRACOMPANY SHIPPING ORDER NR N 132323 TAPED TO SIDE OF CARRIER AND CLEANED FOOD DEBRIS FROM AFT OVEN. SHIPPING TICKET SHOWED EVIDENCE OF BURNING.Nov 13, 1999 · N968DL · Doug MD88SDR DLM88992506Oven · contaminatedCREW REPORTED, BURNING SMELL FROM FWD PORTION OF CABIN, NO SMOKE. UNABLE TO DETERMINE LOCATION/ORIGIN OF FUMES. INSPECTED CABIN OVHD AND GALLEY AREAS, STATIC PORT HEATERS, APU INLET AND OIL LEVEL. RAN PACKS WITH BOTH ENGINES. ONLY ODOR CAME FROM THE FWD GANov 12, 1999 · N912DE · Doug MD88SDR DL76G992499Chiller · overheatedMID GALLEY CHILLER FAULT LIGHT ILLUMINATED, WALL BEHIND SEAT 10C SEAMED VERY HOT. TURNED OFF, WALL COOLED. CLEANED OUTLET AND VENT PORTS OF CHILLER, OPS CK OK. NO FAULT LIGHT OCCURRED.Nov 11, 1999 · N1501P · Boeing 7673P6SDR 9905221154Oven · fireAFTER PUSHBACK, FLIGHT ATTENDANT REPORTED FIRE IN AFT GALLEY. ONE HALON BOTTLE WAS DISCHARGED. AIRCRAFT RETURNED TO GATE. FIRE WAS CAUSED BY PAPER/TRASH BEHIND THE OVENS AND COFFEEMAKER. AFTER CLEANUP, GALLEY EQUIPMENT WAS CHECKED FOR PROPER OPERATION. CHNov 11, 1999 · N154US · Doug DC1040SDR DL76G992468Oven · malfunctionedGALLEY MID CABIN CENTER OVEN OVERHEATS, TOP WILL NOT SHUT OFF. REPLACED OVEN, SYSTEM CHECKS NORMAL.Nov 9, 1999 · N394DL · Boeing 767324SDR CA991208041Controller · sticking(CAN) OVEN TIMER STICKING. OVEN CONTROLLER REPLACED.Nov 8, 1999 · Bag BAE146200ASDR AALA991667Oven · dirtyMAD - FLT 0068 - EN ROUTE MIA/MAD, NR 2 FIRST CLASS GALLEY OVEN EMITTED SMOKE AND SPARKS. CIRCUIT BREAKER PULLED AND AIRCRAFT CONTINUED TO MAD AND LANDED WITHOUT INCIDENT. CLEANED DIRT AND FOOD RESIDUE FROM NR 2 FIRST CLASS CABIN OVEN AND FAN. OVEN OPERATED Nov 8, 1999 · N378AN · Boeing 767323SDR DL757992445Oven · failedELECTRICAL ODOR IN FIRST CLASS GALLEY. ELECTRICAL POWER REMOVED. FOUND ODOR TO BE COMING FROM F/C GALLEY AFT OVEN. TIMER CONTROL PANEL HOT TO TOUCH FORTY FIVE MIN AFTER POWER. REMOVED AND REPLACED OVEN, RAN NEW ONE ODOR GONE OVEN CKS GOOD.Nov 5, 1999 · N6700 · Boeing 757232SDR DL777992430Coffee Maker · failedLEFT COFFEEMAKER POPPED. RESETTING CENTER C/B CAUSES ARCING IN AFT COFFEEMAKER. ISOLATED PROBLEM TO NR 2 C/M IN LEFT AFT GALLEY. PULLED AND COLLARED POWER C/B FOR NR 2 C/M. FWD TO MCO AND PLACARD. C/M NASI LGW.Nov 2, 1999 · N860DA · Boeing 777232SDR USAASB99261Coffeemaker · malfunctionedIAD - FLT 488 - EN ROUTE FROM PIT-BWI, F/A REPORTED SMELL OF BURNING WIRES AND FUMES IN THE AFT CABIN. NO VISIBLE SMOKE WAS NOTED. AN EMERGENCY WAS DECLARED AND FLT DIVERTED TO NEAREST AIRPORT AT IAD. FLT LANDED W/O FURTHER INCIDENT. MX RAN BOTH ENGINES TOOct 29, 1999 · N355US · Boeing 737301SDR MZZA99188Oven · failedFLT 972 - AFTER PUSHBACK AIRCRAFT RETURN TO GATE DUE TO OVEN SMOKING IN THE AFT GALLEY. MAINTENANCE INSPECTED OVEN AND PLACARDED AFT GALLEY AFT FACING OVEN INOPERATIVE AND CIRCUIT BREAKER PULLED. RELEASED AIRCRAFT FOR SERVICE AND REDISPATCHED. GUAM MAINTENAOct 28, 1999 · N79743 · Boeing 727224SDR CA991103070Water Heater · overheated(CAN) BURNT SMELL REPORTED BY CREW. THROUGH INVESTIGATION BY MAINTENANCE REVEALED BURNT SMELL COMING FROM SPILLED COFFEE ON HOT PLATE.Oct 25, 1999 · Airbus A330243SDR 99UAL900548Connector · corrodedAFT COFFEEMAKER CAUSED SMOKE, SMOKE STOPPED WHEN POT TURNED OFF. *S/D* SMOKE CAUSED BY CORRODED AND BURNED CONNECTOR ON AIRCRAFT SIDE. REPLACED CONNECTOR. THIS WAS AN ISOLATED INCIDENT.Oct 24, 1999 · N7251U · Boeing 727222SDR DL76G992337Chiller · overheatedMID GALLEY AFT CHILLER FAULT LIGHT ILLUMINATED. SHORTLY THERE AFTER NOXIOUS PLASTIC SMELL CAME FROM VENT AREA BETWEEN THE OVEN AND THE FREEZER CHILLER. OVEN C/B PULLED, BOTH ITEMS PUT ON MCO 25-20-01.Oct 23, 1999 · N155DL · Boeing 7673P6SDR DL777992296Coffee Maker · failedCOFFEEMAKERS INOP AFT CO-PILOTS SIDE, COFFEEMAKERS 108, 109, 110. ELECTRICAL SMELL NOTICED IN AREA AND CIRCUIT BREAKERS PULLED. REPLACED COFFEEMAKERS.Oct 19, 1999 · N860DA · Boeing 777232SDR PLGA991017Coffee Pot · failedMHT - FLT 4814 - THE FLIGHT ATTENDANT NOTICED BURNING SMELL IN THE CABIN. THE PILOT WAS NOTIFIED AND THE AIRCRAFT DIVERTED INTO MHT AND LANDED WITHOUT INCIDENT. MAINTENANCE LOOKED AT AND FOUND THE COFFEE URN AND PLUG TO BE AT FAULT. THE SYSTEM WAS DEACTIVATOct 17, 1999 · N357BE · Saab 340BSDR DL757992282Filter · cloggedSLIGHT ELECTRICAL/BURNING PLASTIC SMELL IN F/C GALLEY. SECURED POWER TO F/C GALLEY AND ODOR DISSIPATED. REPLACED F/C FREEZER FILTER.Oct 16, 1999 · N629DL · Boeing 757232SDR CA991103095Oven Fan · burnt(CAN) IN CRUISE, SMOKE COMING FROM AREA NEAR CENTER OVEN REAR GALLEY. ALL OVENS SHUT OFF, CIRCUIT BREAKERS PULLED. SMOKE DISSIPATED, OVENS LEFT OFF FOR DURATION OF FLIGHT. NR 2 RIGHT FAN BURNT AND SEIZED, REPLACED.Oct 15, 1999 · Boeing 767275SDR DL757992242Oven · steamingAFT F/A REPORTED SMOKE NEAR CEILING JUST PRIOR TO TAKEOFF. FOUND EXCESSIVE MOISTURE/STEAM COMING FROM MEALS IN THE OVENS.Oct 9, 1999 · N646DL · Boeing 757232SDR 99UAL900503Food Cart · malfunctionedAFT GALLEY ELECTRICAL PIGTAIL GAVE OFF SPARKS AND ODOR. *S/D* INSPECTED CABLES AT ALL POSITIONS AND FOUND NO EVIDENCE OF BURNED, BENT, DAMAGED. SUSPECT BAD CARTS. REMOVED AND REPLACED FOOD CARTS.Oct 1, 1999 · N540UA · Boeing 757222SDR SWAA991601Latch · brokenAIR TURNBACK, AFTER TAKEOFF, A THUMPING NOISE HEARD ON FWD LAV. FOUND FWD LAV SINK CABINET DOOR OPENED AND LATCH BROKEN. REMOVED AND REPLACED LATCH ASSY PER MM.Sep 26, 1999 · N368SW · Boeing 7373H4SDR DL76L992142Coffee Maker · contaminatedF/A REPORTED ELECTRICAL BURNING SMELL IN AFT GALLEY. TURNED OFF GALLEY ITEMS AND C/BS. INDIVISUALLY REPOWERED ITEMS. SMELL DID NOT RETURN. FOUND BURNT PAPER UNDERNEATH COFFEEMAKER PULLED AND COLLARED C/BS. FWD TO MCO.Sep 23, 1999 · N190DN · Boeing 767332SDR AALA991420Oven · defectiveMIA - FLT 1543 - EN ROUTE MIA-SDQ - FLIGHT ATTENDANTS NOTICED SMELL OF SMOKE AND HAZE IN FIRST CLASS GALLEY. AIRCRAFT RETURNED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED OVEN IN FIRST CLASS GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 20, 1999 · N390AA · Boeing 767323SDR 99UAL900481Connector · failedGALLEY HOT PLATE SMOKING AND SPARKING. HOT PLATE CORD FRAYED AND EXPOSED. *S/D* REMOVED HOT PLATES, INSPECTED WIRING FROM GALLEY WALL TO PLATES AND NO DAMAGE, NO OPEN INSULATION, NO BRITTLENESS. INSTALLED NEW CONNECTORS, CLEANED AREA, RECONNECTED HOT PLATESep 16, 1999 · N7459U · Boeing 727222SDR 99UAL900477Oven · dirtyPER CREW SMOKE IN CABIN BETWEEN DR2 AND DR3 CABIN AREA. BURNT MEALS IN THE FORWARD LOWER LOBE GALLEY, OVEN NR 3 WERE THE SOURCE OF THE CABIN SMOKE.Sep 16, 1999 · N153UA · Boeing 747123SDR TWAA9912302Coffee Maker · failedDURING CRUISE GOT A BURNING SMELL FROM NUMBER 2 COFFEE MAKER. REPLACED COFFEE MAKER. CC 3-3-99 MCI.Sep 9, 1999 · N986Z · Doug DC931SDR AALA991328Oven · defectiveMIA-YUL - FLT 470 - AFTER TAKEOFF, SMOKE NOTED FROM NR 3 GALLEY OVEN. GALLEY POWER WAS TURNED OFF IN FLIGHT AND AIRCRAFT RETURNED TO MIA AND LANDED WITHOUT INCIDENT. REPLACED NR 3 GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Sep 6, 1999 · N556AA · Doug DC982SDR AU991004Wire · failed(AUS) AFT GALLEY POWER SUPPLY CABLES DAMAGED AND SHORT CIRCUITING SUSPECT DUE TO INSULATION BREAKDOWN.Sep 4, 1999 · Boeing 737476SDR 99UAL900458Oven · smokingFWD GALLEY OVEN SMOKING WITH ELECT SMELL.Sep 2, 1999 · N603UA · Boeing 767222SDR DLM88991918Oven · dirtyEN ROUTE TO MKE ON FLT 1872/28, THE FLT CREW REPORTED BURNING SMELL IN FWD GALLEY. FOUND FOOD BOILED OVER IN OVEN, NO VISIBLE SMOKE OCCURRED. CLEANED OVEN.Aug 28, 1999 · N903DL · Doug MD88SDR DL73E991904Plug · failedELECTRICAL BURING SMELL FROM AFT GALLEY COFFEE MARKER. PULLED C/B SMELL STOPPED. REPLACED BOTH AFT COFFEE MARKERS FOUND CANNON PLUG TO NR 1 AFT COFFEE MARKER BADLEY CORRODED. FWD AFT COFFEE MARKER NR 1 TO MCO AND PLAC PULLED AND COLLARED C/B. NEEDS NEW CANAug 26, 1999 · N381DL · Boeing 737247
Back to JASC 2530