Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DLM88991883Oven · odorSMOKE IN CABIN. FOUND GALLEY OVEN CAUSING SMELL, CORRECTED.SDR CA990927082Oven · malfunctioned(CAN) EN ROUTE ELECTRICAL SMELL IN FORWARD GALLEY, GALLEY POWER TURNED OFF BURN SMELL PERSISTED, EMERGENCY DECLARED AND AIRCRAFT LANDED. OVEN REMOVED AND ROUTED FOR REPAIR. NEW OVEN INSTALLED AND RUN FOR ONE HOUR AND NO SMELL.SDR AALA991228Oven · dirtyLHR - FLT 142 - NR 2 GALLEY OVEN SMOKES WHEN HEATED. OVEN DEACTIVATED AND FLIGHT LANDED LHR WITHOUT INCIDENT. CLEANED RESIDUAL FOOD FROM OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR 99UAL900426Oven · dirtyCABIN ODOR EXPERIENCED AT FL 280 IN DESCENT. OVENS AND LIGHTS TURNED OFF. ODOR SUBSIDED BUT STILL LINGERED. *S/D* OVEN UPPER BAFFLE WAS CONTAMINATED WITH MELTED PLASTIC. OVEN WAS REMOVED AND SHIPPED TO THE COMPONENT SHOP. UNIT WAS CLEANED, TESTED AND RETSDR DLL14991799Coffeemaker · failedELECTRIC SMOKE FROM MID GALLEY COFFEEMAKER AREA ON, CAPTAIN'S SIDE. SMOKE STOPPED WHEN COFFEEMAKERS WERE TURNED OFF. REPLACED BOTH COFFEE MAKERS.SDR 99UAL900425Oven · dirtyFIRST CLASS GALLEY HAS ELECTRICAL SMELL. SMALL AMOUNT OF SMOKE DETECTED. *S/D* FIRST CLASS OVEN WAS REPLACED IN BOS ON 8/13/99. OP CHECKED GOOD. SHOP FINDINGS ON REMOVED OVEN MR25350-104: OVEN HAD BURNED OIL INSIDE (GREASE). CLEANED, TESTED AND RETURNEDSDR DLM11991782Oven · smokingOVEN LOC 281 OVERHEATS SMOKES DURING OPERATION. OVEN WIRE HARNESS ELECT GENERAL INSPECTED, NO DAMAGE NOTED. REPLACED OVEN.SDR 99UAL900414Coffemaker · smokingLOWER COFFEEMAKER IN AFT GALLEY SMOKING AND SPARKING. *S/D* REPLACED COFFEEMAKER. INSPECTED WIRING, LEFT UNIT ON FOR SEVERAL HOURS, NO DEFECTS NOTED.SDR CALA9900879Coffeemaker · shortedSMOKE WAS REPORTED IN THE VICINITY OF THE AFT GALLEY COFFEEMAKER WHILE EN ROUTE TO IAH. THE FLIGHT ATTENDANT DISCHARGED THE HALON FIRE EXTINGUISHER ONTO THE AREA, THE GALLEY POWER WAS TURNED OFF, AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED TO IAH WHERE ITSDR AALA991089Oven · dirtySFO - FLT 177 - EN ROUTE JFK-SFO, NR 2 OVEN IN FIRST CLASS GALLEY PRODUCED SMOKE AND A BURNING ODOR. CLEANED NUMBER 2 FIRST CLASS GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DLM88991653Oven · dirtyFIRST CLASS OVEN SMOKING IN CABIN. FOUND PAPER AND SHIPPING DOCUMENTS ON F/C OVEN INSERT. CLEANED OVEN AND REMOVED INSERT.SDR AALA991077Oven · dirtyBFL - FLT 1588 - AFTER TAKEOFF FROM BFL TO DFW, FLIGHT ATTENDANT'S REPORTED SMOKE IN CABIN. DISCONNECTED POWER TO GALLEY AND DECLARED EMERGENCY. LANDED BFL WITHOUT INCIDENT. CLEANED OVEN. ALSO REPLACED COALESCER BAGS AND RIGHT HAND AIR CONDITIONING PACK AUSDR SCNA99094Coffeemaker · failedDURING FLIGHT, NUMBER THREE COFFEEMAKER SPARKED THEN THE GALLEY POWER TRIPPED OFF LINE. GALLEY COFFEEMAKER CIRCUIT BREAKERS THEN PULLED. REMOVED AND REPLACED THE COFFEMAKER AND CHECKED ALL ELECTRICAL TERMINALS. RESET CIRCUIT BREAKER AND OPERATIONALLY CHECKSSDR DL76L991552Chiller · malfunctionedGALLEY 413 FAULT LIGHT CAME ON. SLIGHT ELECTRIC ODOR AFTER CHILLER SHUTDOWN. INSPECTED GALLEY (413) CHILLER, OPS OK. RAN FOR 45 MIN, NO FAULT AND DETECTED NO ELECTRIC ODOR BURN.SDR USAAD99093Coffeemaker · dirtyPIT-IND - FLT 705 - DURING CLIMB, FUMES AND SMOKE WERE DETECTED AROUND THE COFFEEMAKER AND IN THE COCKPIT CLOSET. THE GALLEY POWER WAS TURNED OFF AND THE CIRCUIT BREAKERS PULLED. THE SMOKE STOPPED WHEN THE GALLEY POWER WAS TURNED OFF. THE AIRCRAFT RETURNED SDR AALA990999Oven · dirtyLHR - DURING OVERNIGHT MAINTENANCE, FIRST CLASS NR 1 OVEN SMOKES AT HIGH TEMPERATURE. CLEANED FIRST CLASS OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR DL76S991504Oven · dirtyACRID FUMES IN COCKPIT AND CABIN COULD NOT ISOLATE. POSSIBLY STRONGER IN FWD GALLEY AND FC AREA. INSPECTED E & E, ALL CARGO COMPARTMENTS, NOTHING FOUND. REMOVED ALL FC GALLEY OVENS AND COFFEEMAKERS, NOTHING FOUND. CHECKED OVERHEAD AREA OF FC CABIN, NOTHINGSDR 99UAL900347Coffee Maker · failedELECTRICAL SMELL AND SPARKING IN AFT GALLEY 441 IN THE AREA OF COFFEEMAKERS. RESET ALL BREAKERS AND TURNED POWER BACK ON TO AFT GALLEY, INSPECTED ALL VISABLE WIRES AND REPLACED COFFEE MAKERS FOR PRECAUTIONARY MEASURES; WAITED 45+ MINUTES WITH POWER ON GALLEY SDR QXEA9901423Receptical · failedPDX - STRONG OR BURNING ODOR COMING FROM AREA OF LOWER COFFEE JUG. MX PULLED AND COLLARED CIRCUIT BREAKER FOR LOWER COFFEE JUG AND PLACED ON MEL. MEL CLEARED ON 7/2/99 BY REPLACING THE PLUG-IN RECEPTICLE FOR THE LOWER COFFEE JUG. OPERATIONAL CHECKS GOOD. ASDR DLM11991458Oven · failedSMOKE NOTICED COMING FROM G-8 GALLEY OVEN DURING FLIGHT. OVEN SHUT OFF. FOUND OVEN 327 FAN NOT RUNNING, CAUSING THE MOTOR TO OVERHEAT. REPLACED OVEN.SDR DLM11991451Oven · failedIN CRUISE, THE NR 327 G-7 GALLEY OVEN HAD AN ELECTRICAL ODOR. CREW HAD TO PULL THE C/B DUE TO IT NOT POPPING. STRONG SMELL AND SMOKE IN AFT AREA. REPLACED OVEN.SDR 99UAL900345Oven · dirtyBURNT PLASTIC SMELL IN MID GALLEY. FOUND AND REMOVED MELTED PLASTIC FROM WARMING OVEN AT POSITION W31. SEA CLEANED INSIDE OF WARMING OVEN.SDR DL76G991474Oven · failedFWD GALLEY NR 1 OVEN SPARKED AND POPPED BREAKER WHEN TURNED ON. REPLACED OVEN.SDR DL73K991445Coffeemaker · failedAFT GALLEY NR 2 COFFEEMAKER WHEN TURNED ON CAUSES SMELL OF HOT ELEC WIRES. INSPECTED CANNON PLUG, CKS OK. REPLACED COFFEEMAKER.SDR DL733991435Oven · failedF/A REPORTED SMOKE COMING FROM OVENS IN LT REAR GALLEY. REMOVED OVENS AND COVER. FOUND MELTED WIRES INSIDE BACK OF OVENS. REPLACED OVENS AND CONTROLLERS. RAN OVENS FOR 20 MIN, OP CHECKS GOOD.SDR 99UAL900340Oven · failedFLIGHT DIVERTED TO LHR UNDER AMBER ALERT DUE TO SMOKE AND ELECTRICAL FUMES IN MID GALLEY WITH VARIOUS ITEMS TURNED ON OR OFF. *S/D* LHR FOUND OVEN R41 SMELLING BADLY WHEN TURNED ON. PULLED AND COLLARED C-B FOR OVEN R41. AT COMPLETION ON FLT 953 IN ORD ON 6SDR TWAA9908802Cart · failedWIRE ON A GALLEY CART WAS REPORTED BURNING UNTIL THE CART WAS DISCONNECTED ELECTRICALLY. REPLACED THE CART. CHECK-C 4-18-99 LAX.SDR AWXA9900221Coffeemaker · malfunctionedON CLIMB 24000 FT, F/A REPORTED BURNING ELECTRICAL SMELL NEAR L1. PRIOR TO AIR TURNBACK, ACFT RETURNED TO GATE BECAUSE OF ELECTRICAL SMELL IN CABIN NEAR DOOR L1. REMOVED AND REPLACED THE NR 1 COFFEEMAKER. PROBLEM WAS AN EXPOSED HEAT ELEMENT. RAN BOTH ENGINSDR AALA990860Oven · defectiveFSD - FLT 1155 - DURING CRUISE EN ROUTE MSP-DFW, FLIGHT ATTENDANT REPORTED SMOKE IN FORWARD GALLEY AREA. NOTED A STRONG SMELL OF ELECTRICAL BURNING AND THIN GRAY SMOKE. VISIBLE SMOKE STOPPED WITHOUT ACTION FROM CREW, GALLEY POWER WAS TURNED OFF AS A PRECAUTISDR AALA990842Oven · defectiveLHR - FLT 46 - EN ROUTE NR 2 FIRST CLASS OVEN SMOKING. TURNED OVEN OFF AND SMOKE DISSIPATED. LANDED LHR WITHOUT INCIDENT. PULLED CIRCUIT BREAKERS AND BANDED AND DEFERRED PER PD. ORD REPLACED FIRST CLASS OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR DL76L991281Oven · dirtyFLIGHT ATTENDANTS REPORTED SMOKE SMELL IN MID GALLEY AFTER ARRIVAL AT GATE. EXAMINED THE OVENS IN MID GALLEY AND CLEANED ACCORDINGLY. ALSO, CHECKED CEILING PANELS AROUND GALLEY, NO EVIDENCE OF BURNING OR SMOKE SMELL OBSERVED.SDR DL767991227Coffeemaker · dirtyELECTRICAL SMELL IN FWD GALLEY AFTER LANDING, STRONG ODOR UTILITY BUSSES TURNED OFF. NO ELECTRICAL ODOR NOTED ON ENTRY. CKD ALL COMPONENTS IN GALLEY, ALL CK NORMAL. NOTED SPILLED AND BURNED COFFEE ON RT FWD COFFEEMAKER. SUSPECT THIS WAS ODOR REPORTEDSDR AALA990782Oven · dirtyLHR - FLT 108 - DURING CRUISE, EN ROUTE BOS-LHR, FIRST CLASS OVENS WERE SMOKING. LANDED LHR WITHOUT INCIDENT. CLEANED FIRST CLASS OVEN OF FOOD DEBRIS. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CA990614092Receptical · failed(CAN) ON GROUND, MSY CIRCUIT BREAKER FOR NR 1 GALLEY POSITION OVEN FOUND TRIPPED, WHEN RESET, CIRCUIT BREAKER TRIPPED AND VISABLE ARCING FROM OUTLET. OUTLET REPLACED.SDR DL76L991109Coffeemaker · dirtyFAS NOTICED ELECTRICAL SMELL ASSOCIATED W/ FWD GALLEY C/MS. SMELL DISSIPATED WHEN THE C/MS WERE SHUT OFF. REMOVED BOTH COFFEEMAKERS AND INSPECTED WIRING. WIRING OK. OPERATED BOTH C/MS, CKD OK. REMOVED REMNANTS OF PLASTIC ON C/M 1 HOT PLATE, OPS OK.SDR AU990456Oven · contaminated(AUS) OVEN SMOKING. INVESTIGATION FOUND THAT THE SMOKE WAS CAUSED BY SPILT FOOD AND CLEANING AGENT.SDR CA990521061Oven · faulty(CAN) NR 2 AFT GALLEY OVEN STARTED SMOKING, OVEN TURNED OFF AND LATER FOUND TO BE AT FAULT.SDR SIMA991314Connector · failedDCA - FLT 4944 - FLIGHT ATTENDANT REPORTED SMOKE SMELL COMING FORM THE GALLEY. CREW PULLED THE HOT CONTAINER CIRCUIT BREAKERS. UPON LANDING, SMOKE WAS COMING FROM THE GALLEY. REMOVED AND REPLACED BOTH HOT JUG CONNECTORS. AIRCRAFT RETURNED TO SERVICE. (M)SDR 99ZZZX2322Fan · inoperativeDURING CRUISE AT FL 41.0, ODOR WAS NOTICED IN AFT GALLEY, SMELLED LIKE PLASTIC MELTING. DIVERTED TO SALT LAKE CITY, WITHOUT FURTHER INCIDENT. FOUND THE NR 4 OVEN FAN INOPERATIVE, OVEN WAS REPLACED, OPS CHECKED GOOD.SDR DLM11991003Oven · dirtyF/C OVENS 102 AND 103 HAD BURNING SMELL. THE OVENS WERE OFF AND HAD BEEN OFF FOR APPROX 30 MIN. RAN OVENS AT MEDIUM FOR 30 MIN. NO TROUBLE FOUND.SDR DLM88990991Oven · dirtyDURING TAXI OUT, SMOKE FROM FIRST CLASS OVEN. FOUND BURNED PAPER MEAL TAG ATTACHED TO MEAL CARRIER. AIRCRAFT TAXIED BACK TO RAMP. MAINTENANCE REMOVED REMAINS OF TAG. CLEANED AND OPERATED OVEN. NO FURTHER SMOKE, OVEN OPERATED NORMALLY.SDR USAABB99020Oven · fireLAX - FLT 41 - EN ROUTE CLT-LAX, FOOD IN THE NR 2 OVEN CAUGHT ON FIRE. THE FLIGHT ATTENDANTS EXTINGUISHED THE FIRE WITH THE FORWARD HALON FIRE BOTTLE. MAINTENANCE REPLACED THE OVEN. (M)SDR DL757990886Oven · smokingFLT ATTENDANT REPORTED SMOKE IN MID GALLEY AREA, MADE EMERGENCY LANDING BOS. INSPECTED AIRCRAFT, PERFORMED PWR RUN. PRESSURIZED AIRCRAFT, FOUND MID GALLEY FWD OVEN SMOKING. REPLACED SAME.SDR QXEA9900852Conector · failedGEG - CREW UNABLE TO REMOVE UPPER COFFEE POT, ELECTRIC SMELL NOTED. MAINTENANCE TROUBLESHOT ELECTRIC SMELL TO LOWER JUG. REMOVED AND REPLACED THE LOWER JUG. COLLARD UPPER JUG CIRCUIT BREAKERS, PLACED ON MEL. PDX MAINTENANCE REMOVED AND REPLACED THE UPPER JSDR DLM11990867Oven · smokingSMOKE COMING FROM MID GALLEY OVEN IN FLIGHT. OVEN SHUTDOWN. OVEN SHUT OFF AND CIRCUIT BREAKER PULLED. SMOKE STOPPED. FLT ATTN REPORTS HAPPENED DURING MEAL PREPARATION. SMOKE WASNOT ELECTRICAL AND FLT ATTN DID NOT THINK IT WAS STEAM. MTC DEACTIVATED OVEN.SDR DL76G990853Outlet · inopCABIN CREW REPORTS BURNING ODOR IN GALLEY 1R. SUSPECT COFFEE MAKER. REPLACED 1R UTILITY OUTLET SOCKET. REACTIVATED CIRCUIT. SYSTEM CHECKS NORMAL.SDR DL76G990813Outlet · shortedUTILITY OUTLET IN FIRST CLASS GALLEY EXTREMELY HOT TO THE POINT OF FUMES IN THE CABIN. ACFT DIVERTED TO ORD. DEACTIVATED AS PER ERA 370761-14.SDR DL76L990799Coffee Maker · failedMAINTENANCE: WORKING MSU ON HISTORY OF ELECTRIC SMELL IN MIDGALLEY AREA. FOUND MID GALLEY FWD COFFEE MAKER BURNER LOOSE AND RESTING ON STAINLESS STEEL SCUPPER DRAIN, WHICH IN TURN MELTED THE PLASTIC TRIM BELOW. REPLACED COFFEE MAKER, CK'D FOR VERIFICATSDR DL757990778Coffeemaker · unserviceableUNIDENTIFIED SMOKE IN AFT GALLEY. DIVERTED TO JFK FOR LANDING. FOUND AFT LT COFFEE MAKER OVERFLOWING. REPLACED COFFEE MAKER AND OPS CHECK OK. ALSO, REMOVED OVENS AND INSPECTED WIRING. ALL CHECKS OK.SDR DL73E990719Coffeemaker · smokingABOUT 15 MIN AFTER T/O AT APPROX 20,000 ALT, F/A REPORTED A STRONG ELECT SMELL IN AFT LAV AREA. SHUT OFF GALLEY PWR AND PULLED AFT LAV C/B. RETURNED TO CVG. ON DESCENT, F/A REPORTED SMELL DIMINISHING. INSPECTED, SUSPECT BURNING COFFEE.
Back to JASC 2530