Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL757982283Oven · fumesFWD CABIN ATTENDENTS REPORTED FUMES. REPLACED F/C OVEN.SDR DL72S982252Coffeemaker · failedINDICATION OF SMOKE OBSERVED BY FLT ATTEND IN AFT GALLEY AND AFT CABIN. REPLACED COFFEEMAKER AND CANNON PLUG.SDR DL72S982241Connector · shortedSMOKE IN AFT CABIN. FOUND THE CANNON PLUG FOR THE NR 3 COFFEEMAKER IN THE AFT GALLY SHORTED. PULLED AND COLLARD C/B, DISCONNECTED CANNON PLUG FROM COFFEEMAKER.SDR VJ9800624Angle · corrodedNR 2 GALLEY ICE DRAWER CORRODED ON BEAM. REMOVED, FABRICATED AND INSTALLED NEW ANGLE IAW DC9 SRM 51-30-1, 51-10-3, 51-10-2.SDR AALA982015Oven · dirtyDFW - FLT 899 - AFTER TAKEOFF DFW, CREW AND PASSENGERS NOTED A SMOKE SMELL IN AFT CABIN. NO SOURCE COULD BE DETECTED BY CREW. RETURNED DFW AND LANDED WITHOUT INCIDENT. FOUND AFT GALLEY OVEN TO BE CAUSE OF REPORTED SMELL IN CABIN. REPLACED AFT GALLEY OVEN. SDR DLM88982171Oven · dirtyAFT GALLEY OVENS HAD LIGHT SMOKE AND BURNING ODOR. TURNED OFF ALL OVENS. SMOKE AND ODOR WENT AWAY, DID NOT SMELL LIKE BURNING FOOD. FOUND TAPE ON OVEN INSERTS. REMOVED INSERTS AND CHECKED OVENS, NO SMOKE NOTED. OPS NML.SDR AALA981925Oven · malfunctionedDFW - FLT 1642 - AFTER TAKEOFF, CREW AND PASSENGERS NOTED BURNING SMELL AND SMOKE. AIRCRAFT RETURNED DFW AND LANDED OVERWEIGHT WITHOUT INCIDENT. FOUND NR 3 GALLEY OVEN TO BE CAUSE OF REPORTED SMELL IN CABIN. REPLACED NR 3 GALLEY OVEN. ACCOMPLISHED OVERWEIGSDR DL76L982164Elect Outlet · failedFIRST CLASS GALLEY, UTILITY OUTLET C/B POPPED. SWITCH ARCED AND SMOKED. ENTIRE UNIT BECAME EXTREMELY HOT. PULLED FORWARD GALLEY C/B. UNIT COOLED.SDR CA981030007Oven · failed(CAN) AIRCRAFT RETURNED DUE TO ELECTRICAL SMELL IN CABIN, GALLEY POWER TURNED OFF, SMELL DISSIPATED. FOUND NR 3 GALLEY OVEN SENSORS DAMAGED. REPLACED RECIRCULATING FAN FILTERS AND AFT GALLEY OVEN VENT FILTERS, OVEN REPLACED, SYSTEM SERVICEABLE.SDR AALA981916Oven · overheatedYYZ- FLT 1012 - EN ROUTE YYZ-LGA, CLIMBING THROUGH 8,000 FT, BLUE THIN SMOKE ENTERED THE COCKPIT AND REMAINED FOR A FEW MINUTES WHILE SLOWLY DISSIPATING. ALL ELECTRICAL LOADS NORMAL. CREW SUSPECTED FIRST CLASS OVEN MAY BE SOURCE OF SMOKE. RETURNED YYZ AND LSDR CALA9801940Oven · failedAFT GALLEY CENTER OVEN SMOKED. REPLACED CENTER OVEN.SDR DL767982109Oven · contaminatedSHORTLY AFTER TAKEOFF, SMOKE OBSERVED FROM AFT GALLEY OVENS. COULD NOT DETERMINE SOURCE OF SMOKE, FOOD OR ELECTRICAL. FOUND BURNT SUBSTANCE IN CORNER OF LOWER LEFT OVEN IN AFT GALLEY. REPLACED OVEN ASSEMBLY AND NEW OVEN, OPS NORMAL.SDR 98UAL900497Oven · fireCREW REPORTED FIRE IN FWD OVEN. FIRE CONTAINED WITHIN OVEN AND OVEN SECURED.SDR 98UAL900487Galley · smokingAIRCRAFT RETURNED TO GATE AFTER FLIGHT ATTENDANT NOTICED SMOKE FROM AFT GALLEY AREA.SDR SCNA98122Wall · delaminatedDURING A MAINTENANCE CHECK, THE CENTER WALL BETWEEN THE P LIFT AND C LIFT WAS FOUND TO BE DELAMINATED. REMOVED AND REPLACED THE DAMAGED SECTION OF HONEYCOMB. FABRICATED AND INSTALLED A DOUBLER IAW MDC-10 SRM 517100.SDR QXEA9801434Receptical · shortedNR 2 WARMER IN GALLEY SMELLS OF HOT ELECTRICAL WIRE. FOUND JUG RECEPTICAL ARCING, POOR PIN TENSION. REPLACED RECEPTICAL, INSTALLED JUG. OPERATION CHECK GOOD. NO SMELLS NOTED.SDR AALA981895Oven · dirtyDFW - FLT 1356 - EN ROUTE DFW - CREW AND PASSENGERS NOTED BURNING SMELL AND SMOKE. NO SOURCE COULD BE DETECTED BY CREW. RETURNED DFW AND LANDED WITHOUT INCIDENT. FOUND FIRST CLASS GALLEY OVEN TO BE CAUSE OF REPORTED SMELL IN CABIN. REPLACED FIRST CLASS GALSDR CALA9801916Oven · failedAN ELECTRICAL BURNING ODOR WAS NOTICED IN THE FORWARD CABIN AREA WHILE EN ROUTE TO ATL. NO VISIBLE SMIKE WAS PRESENT. THE AIRCRAFT LANDED AT ATL WITHOUT INCIDENT. MAINTENANCE FOUND THE FORWARD GALLEY NR 2 OVEN HAD A BURNED MOTOR. THE OVEN WAS PLACARDED INOPSDR USAAF98082Coffee Maker · overheatedBWI - FLT 1192 - EN ROUTE TO BWI AT FL230, SMOKE SMELL ENTERED THE COCKPIT. CREW STATED THAT SMOKE WAS NOT VISIBLE AND FLIGHT ATTENDANTS ALSO SMELLED SMOKE AND COULD SEE IT COMING FROM ABOVE COFFEE MAKERS. THE FLIGHT CREW PULLED THE COFFEE MAKER CIRCUIT BREASDR DLM88982044Oven · failedFWD GALLEY OVEN OVERHEATED AND STARTED SMOKING, PULLED C/B AND DISCONNECTED GALLEY POWER, SMOKED STIPPED. REPLACED OVEN/OPS OK.SDR AU981281Fan · jammed(AUS) OVEN FAN JAMMED BY MEAL TRAY CAUSING DAMAGE TO THE FAN MOTOR.SDR VJ9800490Ice Compt · corrodedINNER SKIN OF LWR O/B COMPARTMENT (ICE) DOOR LOOSE AND CRACKED AT LWR END, NR 2 GALLEY. REMOVED INNER SKIN FOUND ON DOOR OUT OF LIMITS IAW SRM 51-10-6. FABRICATED NEW DOOR AND U CHANNEL, INSTALLED DOOR IAW SRM 51-40-10, 51-30-2.SDR MWEA98945Oven · dirtyTHE LEFT OVEN STARTED TO SMOKE AND FLIGHT ATTENDANT TURNED OFF. MTC CLEANED AND OPS CHECKED OVEN.SDR DL72S981702Oven · smokingFWD GALLEY OVENS EMITTED BURNING PLASTIC SMELL AND VISABLE SMOKE AFTER TURNING ON. FOUND PLASTIC SHIPPING LABEL ON SIDE OF FOOD CARRIER. REMOVED AND REPLACED CARRIER.SDR DLM11981661Chiller · failedAFT GALLEY CHILLER G8 HAS SMOKE COMING OUT OF IT. REPLACED CHILLER.SDR CA980827024Tray · contaminated(CAN) SMOKE OBSERVED IN GALLEY. SUBMITTER STATED PROBLEM CAUSED BY TAPE LEFT ON FOOD TRAY. TAPE REMOVED AND SMOKE/SMELL DISAPPEARED.SDR CA980818008Coffee Maker · malfunctioned(CAN) COFFEE MAKER FLASHED AND SMOKED, SMELL OF BURNING ENSUED. REPLACED COFFEE MAKER. PHASE LOSS DETECTOR CARD RESISTOR OVERLOADED AND BURNT.SDR USAASB98194Coffee Maker · failedBWI - FLT 7095 - EN ROUTE FROM MIA-BWI, A STRONG ACRID ODOR EMINATED FROM THE AFT RIGHT GALLEY. ODOR WAS ISOLATED TO THE VENT IN THE AFT RIGHT GALLEY WHICH IS NOT PART OF THE AIR CONDITIONING SYSTEM. TURNED OFF GALLEY POWER AND PULLED GALLEY COFFEE CIRCUIT BSDR TWRA9840Oven · dirtyIN FLIGHT, FLIGHT ATTENDANT REPORTED SMELL OF ELECTRICAL NATURE IN THE MID GALLEY. ALL POWER TURNED OFF AND ITEM TRANSFERRED TO ODI 25587. FROM LOG PAGE 25587 OPERATED ALL OVENS, LIGHTS, AND COFFEE MAKERS. ALL OPERATED NORMAL. NO SMOKE, NO SMELL, NO SPARKSSDR AU981120Oven · fire(AUS) FORWARD GALLEY OVEN CAUGHT FIRE DUE TO FOOD OIL SPILLED ONTO TRAY. FIRE EXTINGUISHER DISCHARGED.SDR AU980919Oven · malfunctioned(AUS) FORWARD GALLEY OVEN FAULTY. SMOKE FROM THE OVEN NECESSITATED USE OF A FIRE EXTINGUISHER.SDR AALA981415Oven · dirtyLGW - FLT 0120 - DURING CRUISE, COACH NR 8 OVEN SMOKES WHEN OVEN IS ON. DISCONTINUED USE OF OVEN. LANDED LGW WITHOUT INCIDENT. CLEANED COACH NR 8 OVEN. GROUND CHECKED NORMAL OPERATION. (X)SDR AALA981414Oven · dirtyLHR - FLT 0092 - DURING CRUISE, FIRST CLASS RIGHT SIDE NR 2 OVEN SMOKED WHEN OVEN ON. DISCONTINUED USE OF OVEN. LANDED LHR WITHOUT INCIDENT. CLEANED FIRST CLASS RIGHT SIDE NR 2 OVEN. GROUND CHECKED, NORMAL OPERATION. (X)SDR 98UAL900341Control Panel · failedFLIGHT ATTENDANT NOTICED SMOKE AND SPARKS COMING FROM THE ELECTRICAL CONTROL PANEL ON THE FORWARD GALLEY ABOVE THE HOT PLATE.SDR SCNA98081Oven · dirtySMOKE WAS OBSERVED COMING OUT FROM A SPACE ABOVE THE NUMBER TWO OVEN IN THE FORWARD GALLEY. CLEANED HEATER ELEMENT AND OPERATED THE OVEN. OPERATIONALLY CHECKED GOOD.SDR TWAA9811202Coffeemaker · malfunctionedTHE OTBD COFFEEMAKER PRODUCED A LARGE SPARK AND ELECTRICAL SMELL. CIRCUIT BREAKERS WERE PULLED. REPLACED COFFEEMAKER. CHECK-C 9-16-97 STL. ACFT TT: 78,249 HOURS. ACFT TC: 84,997. (X)SDR AALA981355Oven · dirtyLHR - FLT 0108 - EN ROUTE BOS/LHR WHILE HEATING MEALS, SMOKE WAS OBSERVED FROM NR 1 AND NR 2 FIRST CLASS OVENS. SHUT OVENS OFF AND SMOKE DISSIPATED. LANDED LHR WITHOUT INCIDENT. CLEANED OVENS, SYSTEM GROUND CHECKED NORMAL OPERATION. (X)SDR AALA981303Oven · dirtyLHR - FLT 0136 - EN ROUTE LAX/LHR, SMOKE EMITTING FROM FIRST CLASS GALLEY OVENS. LANDED LHR WITHOUT INCIDENT. CLEANED BOTH FIRST CLASS OVENS. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR USAASB98166Oven · overheatedPGV - FLT 1077 - AT FL 350 EN ROUTE TO JAX FROM LGA, THE FORWARD GALLEY OVEN CAUGHT FIRE. THE FLIGHT ATTENDANT USED A FIRE EXTINGUISHER AND PUT OUT THE FIRE. THIRTY MINUTES LATER THE FIRE RESTARTED AND SMOKE ENTERED THE COCKPIT. CAPTAIN DECLARED AN EMERGENCSDR AALA981283Coffee Maker · failedLHR - FLT 0046 - EN ROUTE ORD/LHR - BUSINESS CLASS NR 3 COFFEE MAKER EMITTED SMOKE. TURNED OFF COFFEE MAKER. LANDED LHR WITHOUT INCIDENT. REPLACED NR 3 COFFEE MAKER. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR DL757981330Oven · dirtyFLIGHT ATTENDANT REPORTED SMELL OF SMOKE TAXIING OUT SLC. RETURNED TO GATE. CHECKED OVENS AND COFFEEMAKERS IN QUESTION, FOUND BURNED TAPE IN NR 2 OVEN CENTER GALLEY FOOD CARRIER. ALSO, CHECKED FWD BAG BIN, NO ODORS NOTED.SDR AALA981266Coffeemaker · malfunctionedLHR - FLT 0142 - EN ROUTE JFK/LHR FIRST CLASS NR 1 COFFEEMAKER EMITTED SPARKS BEHIND BUTTON LABELED 'HOT'. TURNED OFF COFFEEMAKER. LANDED LHR WITHOUT INCIDENT. REPLACED NR 1 COFFEEMAKER. SYSTEM GROUND CHECKED, NORMAL OPERATION. (X)SDR CALA9801150Circuit Breaker · failedA BURNING ELECTRICAL SMELL WAS DETECTED AT THE FORWARD FLIGHT ATTENDANT PANEL WHILE ON FINAL APPROACH. THERE WAS NO VISIBLE SMOKE. THE AIRCRAFT LANDED AT EWR WITHOUT INCIDENT. THE CIRCUIT BREAKER PANELS IN COCKPIT BEHIND JUMPSEAT AND THE E AND E COMPARTMENTSDR SCNA98067Oven · sparkingTHE LEFT FORWARD OVEN WAS REPORTED TO BE SPARKING. FOUND THE LEFT FORWARD OVEN CIRCUIT BREAKER POPPED. RESET CIRCUIT BREAKER. OPERATED OVEN WITH NO DISCREPANCIES FOUND. OVEN RACKS HAD ALREADY BEEN REMOVED. SUSPECT OVEN RACKS MAY HAVE BEEN HITTING FAN, OVESDR 98UAL900259Oven · dirtyFOOD WRAPPER IN FORWARD OVEN CAUGHT FIRE. HALON EXTINGUISHER USED TO PUT FIRE OUT. *S/D* FOOD WRAPPER WAS NOT PROPERLY INSTALLED. REMOVED WRAPPER, CLEANED OVEN, OPS NORMAL.SDR CA980706030Oven Socket · failed(CAN) DURING APPROACH, AN ELECTRICAL BURNING SMELL WAS DETECTED COMING FROM THE GALLEY. THE GALLEY POWER WAS TURNED OFF, SMELL DISSIPATED AND A/C LANDED SAFELY. MAINTENANCE FOUND OVEN POSITION NR 17 SOCKET BURNT. OVEN POSITION NR 17 SOCKET WAS REPLACED.SDR USAASB98147Coffee Maker · leakingPIT - FLT 1250 - AFTER TAKEOFF, THE AFT GALLEY COFFEE MAKERS STARTED CREATING SMOKE AND PRODUCED A RUBBER SMELL. COFFEE MAKERS WERE NOT TURNED ON AT THE TIME. FLIGHT ATTENDANT PULLED CIRCUIT BREAKERS AND SMOKE AND SMELL DISSIPATED. FLIGHT CONTINUED AND LANDSDR TWRA9831Coffee Maker · failedIN FLIGHT, SMOKE SEEPING FROM AFT SLOT OF CEILING PANEL IN AFT GALLEY JUST FORWARD OF COFFEE MAKERS, TURNED OFF GALLEY POWER AND PULLED OVEN CONTROL C/B'S, SMOKE STOPPED. INSPECTED AREA, FOUND COFFEE MAKER AT POSITION 516 WITH BURNED WIRES TO HOT JUG. REMOVESDR 98UAL900231Power Supply · overheatedCREW REPORTS ELECTRICAL BURNING SMELL IN AFT GALLEY ON DESCENT. *S/D* THE SMELL RESULTED FROM OVERHEATING OF POWER SUPPLY COMPONENTS IN THE CABIN AREA CONTROL PANEL. UNDER CONDITIONS WHERE BOTH BACK LIGHTS FAIL, THE POWER SUPPLY MAY OVERHEAT. BOEING SERVICSDR 98ZZZX3265Relief Valve · sticksRELIEF VALVES STICKS. WILL NOT RELIEVE AT RATED PRESSURE. THIS PHENOMENA HAS BEEN OBSERVED AS LITTLE AS TWO MONTHS AFTER A PREVIOUS STOP VISIT. SUBMITTER BELIEVES THE CONDITION RESULTS FROM THE RUBBER COMPOSITION OF THE VALVE FACE MAKING CONTACT AND STICKIN
Back to JASC 2530