duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR DL757980001Oven · dirtyPASSING 8K' ON DEPART. F/A REPORTED SMOKE IN AFT GALLEY CEILING AREA. OVENS TURNED OFF AND C/B'S PULLED, SMOKE DISSIPATED. CHKD OVENS AND COFFEEMAKERS IN AFT GALLEY AND ALL GOOD. CHKD AFT GALLEY LIGHTS AND GOOD. DROPPED OVHD CEILING PANEL AND AREA OK. AFSDR DL733972737Oven · overheatedON TAXI FLIGHT, ATTENDANT REPORTED SMOKE COMING FROM AFT GALLEY OVENS ON CAPTS SIDE. SMOKE STOPPED WHEN OVEN POWER WAS TURNED OFF. RETURNED TO GATE. FOUND AFT LEFT IB OVEN AND AFT RT OB OVENS WITH PANEL FAIL LIGHTS. INSPECTED REAR GALLEY AND OVEN AREAS FORSDR SCNA98020Coffeemaker · sparkingSPARKS NOTICED FROM FOWARD GALLEY COFFEEMAKER WHEN ACTIVATED. REMOVED AND REPLACED COFFEEMAKER AS A PRECAUTIONARY. FUNCTIONALLY CHECKED GOOD.SDR SCNA98019Coffeemaker · sparkingSPARKS NOTICED FROM FOWARD GALLEY COFFEEMAKER WHEN ACTIVATED. OPS CHECKED COFFEEMAKER IN FORWARD GALLEY PER MAINTENANCE MANUAL CHAPTER 253000. FUNCTIONALLY CHECKED GOOD.SDR DLL19972662Oven · ovrheatedGALLEY MID AFT CENTER OVENS OVERHEATS DIRTY TRAYS CAUSE SMOKE, CLEANED OVEN AND TRAYS.SDR DLM88972644Coffeemaker · failedDURING FLT, AFT GALLEY COFFEEMAKER STARTED TO SMOKE. REPLACED COFFEEMAKER.SDR DL76G972606Coffeemaker · failedNOTICED SLIGHTLY ACRID ELECTRICAL SMELL COMING FROM MID GALLEY. REPLACED NR 1 AND NR 2 COFFEEMAKERS IN MID GALLEY.SDR DL72W972592Coffeemaker · failedNOTED ELECT SMELL IN FWD GALLEY AREA. REPLACED COFFEEMAKER.SDR DL76S972495Coffeemaker · failedSTRONG ELECTRICAL ODOR COMING FROM BEHIND COFFEEMAKERS IN FIRST CLASS GALLEY. ALSO, VERY HOT TO TOUCH ABOVE COFFEEMAKERS IN FLIGHT. REPLACED NUMBER 1 FIRST CLASS COFFEEMAKER. OPERATED ALL FIRST CLASS GALLEY SYSTEMS, NO ODOR NOTED.SDR TWAA9713901Service Cart · failedJFK - FLT 903 - DURING CRUISE, NR 3 AFT GALLEY 1564 CART EMMITED SPARKS. REPLACED GALLEY SERVICE CART MFG P/N 88801-1, CHORD AND CONTROLLER. AIRCRAFT WIRING CHECKED OK. OPERATION NOW NORMAL, MFG P/N 88801-1. (M)SDR DL76L972372Coffeemaker · failedACRID ELECT BURNING SMELL IN AFT GALLEY 1 HR AND 15 MIN INTO FLT. SMELL DISAPPEARED AFTER TURNING OFF CEILING LIGHTS IN GALLEY AND UTILITY BUSSES. A/C FERRIED TO CVG WHERE COFFEEMAKERS FOUND AT FAULT. REPLACED COFFEEMAKERS.SDR DL76L972362Coffeemaker · burned tapeREAR GALLEY HAS OCCASIONAL BURNING ELECTRICAL SMELL. FOUND BURNED TAPE UNDER HEATING PAD OF COFFEEMAKER. DEACTIVATED COFFEEMAKER AND FWD TO MCO.SDR DL757972359Coffeemaker · failedMID CABIN F/A'S AND PAX REPORTED A SMELL IN MID CABIN. ODOR REPORTED TO BE AN ELECTRICAL TYPE ODOR. CKD ALL LIGHT BALLASTS FOR OVRHT, CKD OPN OF ALL OVENS, CKD ALL OTHER GALLEY APPLIANCES. EVERYTHING OK FOR SERVICE. REPLACED TWO MID GALLEY COFFEEMAKERS DUE SDR DLL14972322Oven · overheatedSMOKE IN 1ST CLASS GALLEY. FOUND OVEN OVERHEATED AND MUFFIN BURNT. CKD GALLEY LIGHTS AND BALLASTS ALL OK. FWD OVEN TO MCO. C/B'S PULLED AND CLAMPED.SDR WTAA970206Connector · looseSFO - SMOKE ODOR FROM GALLEY AREA REPORTED. MAINTENANCE INSPECTED AREA. NO EVIDENCE OF SMOKE ODOR OR DEFECTS NOTED. AS PRECAUTION MAINTENANCE DEFERRED GALLEY PER MEL 25-60-2. AIRCRAFT RETURNED TO SERVICE. NOTE, MAINTENANCE SUBSEQUENTLY CLEARED DEFERRAL BYSDR 97ZZZX4716Heater Element · explodedTHE HEATER ELEMENT FAILED WITH AN EXPLOSIVE LIKE CHARGE THAT SENT THE FAILED ELEMENT AND WIRES INTO THE HONEYCOMB GALLEY TOP.SDR WWMA9700170Hot Jugs · dryCREW REPORTS THE GALLEY SMELLS LIKE A COMBINATION OF BURNING INSULATION AND BURNING COFFEE. ODOR GOES AWAY WHEN THE JUGS ARE TURNED OFF. UPON INVESTIGATION MAINTENANCE FOUND THE NR 2 HOT JUG TO BE OUT OF FLUID. INSPECTED ELECTRICAL CONNECTORS WITH NO DAMAGESDR DL757972223Coffeemaker · inoperativeAFT GALLEY BURNING SMELL DURING CRUISE, PULLED AFT GALLEY C/B FOUND ODOR COMING FROM AFT LT COFFEEMAKER. REPLACED SAME, LEAK CHECKED OK, OPS NORMAL.SDR TWAA9713101Cart · dirtySTL - FLT 2 - DURING CRUISE, THE SINGLE SERVICE FOOD CART EMMITTED SMOKE AND FUMES. REMOVED AND REPLACED CART, MFG 88801-1, MANUFACTURED BY PTC AEROSPACE, INC. OPERATIONAL CHECK NORMAL. (M)SDR DLM88972244Coffeemaker · failedTHE FORWARD GALLEY COFFEEMAKER CIRCUIT BREAKER POPPED, THE F/A NOTICED A BURNING SMELL AND HEARD A POPPING NOISE, NOTICED THE C/B THEN POPPED. CONTACTED ATL MCC. REPLACED F/C COFFEEMAKER, RESET C/B, BREWED COFFEE. OPS NORMAL, NO SMELL NOTED.SDR DL76S972173Coffeemaker · failedELECTRICAL BURNING SMELL COMING FROM MID GALLEY AREA WHEN COFFEE MAKER IS USED. REPLACED COFFEEMAKER.SDR DLL13972137Oven · dirtyOVEN FIRE CAUSED BY FOOD SPILL. CLEANED OVEN OPERATION NORMAL.SDR DL72S972080Oven · failedFWD GALLEY OVEN FIRE IN FLT AFTER DEPARTURE. PERFORMED SMOKE/ID, RMVAL AND CLEAN UP CHECKLIST. RETURNED TO LAND AT PHX. REMOVED OVEN, INSPECTED WIRING AND COMPARTMENT, ALL CKD OK. REPLACED OVEN AS PRECAUTIONARY.SDR DL733972063Oven · failedF/A CALLED TO SAY SHE WAS GETTING STRONG ELEC SMOKE FROM FWD GALLEY OVENS. SMOKE INCREASED, PULLED GALLEY FWD C/BS AND TURNED OFF GALLEY PWR AND SMOKE DECREASED. RTB TOOK PAX OFF. DEACTIVATED FWD GALLEY OVEN. FOUND ELEC SMELL ON OTBD OVEN FAN EXIT. PULLEDSDR TWAA9712402Connector · failedSTL - FLT 629 - FUMES PRESENT IN F/C GALLEY ON PUSH-BACK. REMOVED NR 2 COFFEE MAKER CANNON PLUG. INSULATED ALL WIRE ENDS WITH CAPS. CK-C 2-14-97 MCI. (X)SDR CA971031015Switch · shorted(CAN) FLIGHT ATTENDANT RECEIVED SHOCK FROM CHILLER SWITCH. REPLACED.SDR QXEA9700648Connector · failedSTRONG ELECTRICAL SMELL COMING FROM THE COFFEE HEATER IN THE GALLEY. UPPER CANNON PLUG SHOWS SIGNS OF ARCING. DISCONNECTED CANNON PLUG AT UPPER COFFEE WARMER AND TURNED OFF. PLACED ON MEL. MEL CLEARED BY REPLACING THE AIRCRAFT COFFEE JUG FEMALE CONNECTOR, SDR CA971031014Hot Cup · shorted(CAN) FLIGHT ATTENDANT RECEIVED ELECTRICAL SHOCK AFTER REMOVING HOT CUP WEN IT CONTACTED WATER TAP.SDR TWAA9712301Coffee Maker · failedSTL - FLT 693 - DURING APPROACH SMOKE WAS DETECTED IN THE COCKPIT DUE TO A SHORTED COFFEE MAKER. REMOVED AND REPLACED THE COFFEE MAKER, MFG P/N 50198A, MANUFACTURED BY NORDSKOG INDUSTRIES. OPERATIONAL CHECK NORMAL. (M)SDR USAASB97275Oven · dirtyMIA - FLT 2182 - AFTER TAKEOFF, THERE WAS A STRONG SMELL FOLLOWED BY VISIBLE BLACK SMOKE THAT CAME OUT OF THE COCKPIT DUCT VENTS. THE COCKPIT FILLED WITH ENOUGH SMOKE THAT THE CREW USED GOGGLES AND OXYGEN. THE SMOKE SMELLED LIKE SOMETHING BURNING IN THE GALLSDR TWAA9712202Oven · overheatedJFK - FLT 901 - DURING CRUISE, THE B-6 OVEN OVERHEATED EMITTING SMOKE INTO THE CABIN AND SOUNDED THE ALARM. REMOVED AND REPLACED OVEN, MFG PN 8201-11-0000, MANUFACTURED BY BUDERUS SELL CORPORATION. OPERATIONAL CHECK NORMAL. OP16-7/16/97. (X)SDR AALA971846Oven · defectiveSFO - FLT 0035 - DURING APPROACH TO SFO, ELECTRICAL ODOR NOTED IN CABIN WITH NO OTHER ABNORMAL INDICATIONS. AIRCRAFT LANDED SFO WITHOUT INCIDENT. REPLACED MID-GALLEY NR 3 OVEN. SYSTEM GROUND CHECKED, NORMAL OPERATION WITH NO ELECTRICAL ODOR NOTED. (X)SDR DL757971915Oven · failedSTRONG ELECTRICAL SMELL IN MID GALLEY AREA. REPLACED MID GALLEY DOUBLE OVEN OPERATED ALL MID GALLEY EQUIP VIDEO EQUIP AS WELL AS AIR COND SYS ALL NORMAL, NO FURTHER ODOR.SDR TWAA9711504Power Chord · failedJFK - FLT 149 - DURING CRUISE, THE AFT GALLEY FOOD CART EMITTED SMOKE DUE TO A BAD POWER CHORD. REMOVED AND REPLACED THE POWER CHORD. FUNCTIONAL CHECK NORMAL. RETURNED CART TO SERVICE. (M)SDR TWAA9711401Oven · dirtyRNO - FLT 235 - DURING CRUISE, THE NR 1 GALLEY EMITTED SMOKE. CLEANED DEBRIS FROM THE INSIDE OF OVEN. OPERATIONAL CHECK NORMAL. OP16 - 6-18-97. (X)SDR DL733971795Oven Controller · malfunctionedELECTRICAL SMELL AND SMOKE EMITTING FROM F/C GALLEY. COTNTRACT MTC CHECKING SAME. REPLACED BOTH CONTROLLERS.SDR CA970922022Receptacle · failed(CAN) DURING DEPARTURE, BURNING SMELL DETECTED IN GALLEY. THE SOURCE WAS THE GALLEY OVEN AT POSITION 16. MAINTENANCE ACTION INVOLVED CHANGING RECEPTACLE AS PER 25-32-00.SDR AALA971600Oven · dirtyLHR - FLT 108 - EN ROUTE BOS/LHR - DURING CRUISE, FIRST CLASS GALLEY OVEN EMITTED SMOKE WHEN DOOR OPENED DURING OPERATION. AIRCRAFT PROCEEDED TO LHR AND LANDED WITHOUT INCIDENT. CLEANED INTERIOR OF FIRST CLASS GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERASDR TC8A97044Microwave · failedWHEN OPERATING MICROWAVE, SMOKE CAME FROM UNIT, SMELL OF MELTING WIRES. PULLED ALL CIRCUIT BREAKERS, SMELL AND SMOKE STOPPED. REMOVED MICROWAVE OVEN.SDR AALA971567Roller Tray · corrodedTUL - RIGHT INBOARD L/L GALLEY ROLLER TRAY HAS CORROSION ON TOP SIDE WHERE ROLLERS ATTACH ALONG THE ENTIRE LENGTH. REMOVED AND REPLACED TRACK AT STA 595 TO STA 872, RT INBD, L/L GALLEY ROLLER IAW WITH 51-01-000-05 AARD. TST: 77,609.0. CYCLES, 23,351. (X)SDR AWXA9700429Coffee Maker · malfunctionedFOUND CM-8 COFFEE MAKER SMOKED AND C/B PULLED. REMOVED AND REPLACED CM-8 COFFEE MAKER. OPS CHECK NORMAL.SDR AALA971389Oven · dirtyLHR - FLT 104 - EN ROUTE JFK/LHR - DURING CRUISE, NR 1 OVEN NOTED WITH BURNED FOOD ON CONVECTION FAN RESULTING IN SLIGHT SMOKING DURING OVEN OPERATION. AIRCRAFT PROCEEDED TO LHR AND LANDED WITHOUT INCIDENT. CLEANED FOOD RESIDUE FROM NR 1 OVEN CONVECTION FAN.SDR CA970812016Refrigerator · odor(CAN) DURING PUSH BACK, BURNING SMELL DETECTED COMING FROM GALLEY FRIDGE COMPRESSOR. GALLEY FRIDGE DEACTIVATED AS PER ENGINEERING INSTRUCTION 7-25-30/07-004552-03.SDR DL76L971436Coffeemaker · odorCOFFEEMAKER IN MID GALLEY GAVE OFF SMOKEY-ELECTRICAL SMELL 6 HRS INTO FLIGHT. REPLACED MID AFT AND RIGHT AFT COFFEEMAKERS, SYSTEM OPS CHECKS NORMAL.SDR TWAA9778001Oven · failedMCI - FLT 427 - DURING CRUISE AFT GALLEY OVEN EMITTED SMOKE. REMOVED AND REPLACED OVEN, MFG PN 8203-11-0000, MANUFACTURED BY BUDERUS SELL CORPORATION. OPS CHECK NORMAL. CHECK C - 11-20-96 - JFK. (X)SDR 9714929880Connector · shortedFLIGHT ATTENDANT REPORTED NR 2 GALLEY OVEN CIRCUIT BREAKER POPPED OUT. TRIED TO RESET AND SPARKS EMITTED FROM BREAKER. MAINTENANCE INSPECTED AND FOUND SHORT IN OVEN CONNECTOR. OVEN REMAINS DEFERRED FOR CONNECTOR REPLACEMENT.SDR DLM11971302Oven · failedB/C GALLEY OVEN F/O SIDE DOUBLE OVEN ARCHED AND SHORTED WITH VISIBLE FLASH AND SPARKS WHEN TIMER WAS SET. POPPED C/B AND MOMENTARILY LIT ELECT WARNING IN COCKPIT. C/B WAS LEFT OUT. REPLACED OVEN ASSY.SDR 97UAL900504Junction Block · crackedSMOKE IN MID GALLEY (ELECTRICAL SMELL). SMOKE WAS COMING FROM PIGTAIL CORD AREA (FAR RIGHT CART STOWAGE AREA). *S/D* CART PIGTAIL JUNCTION BLOCK BROKEN WITH TWO LOOSE WIRES. REPLACED JUNCTION BLOCK AND REPAIRED WIRES.SDR CA970710010Galley Assy · elect short(CAN) ON APPROACH AUTO PILOT DISCONNECTED AND SMOKE BEGAN TO DEVELOP IN FLIGHT DECK. THE "C" PHASE GALLEY POWER CIRCUIT BREAKER HAD OPENED. GALLEY ELECTRICAL POWER SWITCH SELECTED OFF, SMOKE DISSIPATED.FORWARD GALLEY ASSEMBLY REPLACED AS PER JOB TICKET 25-80-0SDR DL72S971179Oven · food fireNR 1 GALLEY OVEN IGNITED PAPER THAT WAS ON BACK OF FOOD CONTAINER. HALON BOTTLE USED TO EXTINGUISH FIRE. REPLACED HALON FIRE EXT, CLEANED AND INSPECTED OVENS.
Back to JASC 2530