SDR DLL19971125Chiller · failedELECT SMELL IN FWD GALLEY AND INTO COCKPIT. FOUND F/C CHILLER BAD FWD TO MCO AND PLAC. DEACTIVATED CHILLER.SDR SWAA970539Coffeemaker · inoperativeEN ROUTE, F/A NOTED ELECTRICAL BURNING SMELL IN FWD GALLEY. INSPECTED, REPLACED COFFEEMAKER AND RAIL ASSEMBLY PER BOEING M/M.SDR WWMA9700086Hot Jug · defectiveCREW REPORTED THE LOW ILLUMINATION LIGHT IN LAVATORY SMELLS WHEN ON. SMELL CONSISTENT OF HOT ELECTRICAL WIRING. UTILITY BUS CIRCUIT BREAKER WAS PULLED. MAINTENANCE FOUND THE NR 2 HOT JUG RECEPTICLE BURNED, AFFECTING THE UTILITY BUS. THE NR 2 HOT JUG WAS DESDR MWEA97457Oven · dirtyDURING FLIGHT, AFT GAL CNTR OVEN BEGAN SMOKING DUE TO FOOD SPILL. MAINT CLEANED OVENSDR CA970722028Coffee Maker · shorted(CAN) TWO HOURS OUT THE FLIGHT ATTENDANT RECEIVED AN ELECTRICAL SHOCK FROM COFFEE MAKER IN NR3 GALLEY. COFFEE MAKER REPLACED.SDR 97ZZZM832Coffeemaker · failedAFTER LANDING NOTICED ODOR IN COCKPIT AND CABIN. COMPLIED PACK BURN OUT CHECK. INSPECTED ALL C/B PANELS NO DEFECTS NOTED. REPLACED SUSPECT COFFEEMAKER. ODOR DID NOT REOCCUR. (M)SDR AALA970971Oven · dirtyLHR - FLT 106 - EN ROUTE JFK/LHR DURING CRUISE, NR 2 OVEN IN FIRST CLASS CABIN SMOKED EXCESSIVELY, NR 2 OVEN WAS TURNED OFF. AIRCRAFT PROCEEDED TO LHR AND LANDED WITHOUT INCIDENT. NR 2 OVEN CLEANED BY CABIN SERVICES. SYSTEM GROUND CHECKED NORMAL OPERATION WSDR DL757970971Coffeemaker · failedMID GALLEY AREA HAS ODD ELECT SMELL. FOUND MID GALLEY AFT COFFEEMAKER CAUSING SMELL. PULLED AND COLLARED C/M APPLIED PWR TO ALL APPLIANCES IN MID GALLEY. NO SMELL NOTED, FWD C/M TO MCO/PLAC PER MEL 25-20-01.SDR 97UAL900381Galley · steam vaporSMOKE CAME OUT OF THE AFT GALLEY TRASH BIN. GALLEY POWER SHUTOFF AND ALL GALLEY CIRCUIT BREAKERS PULLED INCLUDING BREAKERS IN THE COCKPIT. SMOKE APPEARED TO STOP. INSPECTED GALLEY FOR EVIDENCE OF HEAT, FIRE, OR SMOKE. NONE NOTED. OPERATED ALL SYSTEMS OVERSDR CA970603018Oven · smoking(CAN) REAR GALLEY STARBOARD SIDE OVEN ELEMENT RED HOT AND SMOKING. FIRE EXTINGUISHER USED AND CIRCUIT BREAKER PULLED. OVEN REPLACED.SDR DL76G970903Oven · smokingSMOKE IN GALLEY FROM OVEN. CLEANED PLASTIC FROM OVEN HEATING COILS.SDR DL73E970882Oven · failedF/A REPORTED, BLUE SMOKE FROM FWD GALLEY OVEN. FLIGHT CREW SMELLED BURNING RUBBER SMELL. OVENS WERE ON. F/A REPORTED CRACKLING NOISE BEHIND OVEN. C/A REPLACED OVEN. WIRING OK. CKS NORMAL.SDR 97ZZZX2522Angle · corrodedGALLEY SERVING CART COMPT ANGLE CORRODED. REMOVED AND REPLACED ANGLE IAW BAC 727 SRM 51-10-6 AND SRM 51-20-04.SDR CA970529010Oven Receptacle · elect shorted(CAN) FIRE FLAMES AND SPARKS IN THE GALLEY OVEN AREA. AIRCRAFT RETURNED TO BASE. MAINTENANCE TROUBLE SHOOTING REVEALED OVEN SOCKETS IN POSITION 16 & 17 BURNT. OVEN RECEPTACLES POSITION 16 & 17 CHANGED. OVENS SENT BACK TO COMMISSIONARY FOR REPAIRS. SYSTEM CHECKSDR USAABB97049Coffeemaker · failedMIA - FLT 1104 - INBOUND TO MIA, CREW REPORTED A STRONG BURNING ELECTRICAL SMELL IN AFT GALLEY. CREW CUT POWER TO THE UTILITY BUSSES (SECURING POWER TO THE GALLEYS). FLIGHT CONTINUED TO MIA AND LANDED WITH NO FURTHER INCIDENT. MAINTENANCE REPLACED BOTH AFT CSDR AALA970816Oven · defectiveDFW - FLT 1403 - DURING DESCENT INTO DFW, ACRID ODOR WITH NO VISIBLE SMOKE NOTED IN CABIN AND COCKPIT. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT LANDED DFW WITHOUT INCIDENT. REPLACED NR 3 AFT GALLEY OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION WITH NO ODORSDR 97ZZZX2011Coffeemaker · failedMIA - FLT 1104 - INBOUND TO MIA, CREW REPORTED A STRONG BURNING ELECTRICAL SMELL IN AFT GALLEY. CREW CUT POWER TO THE UTILITY BUSSES (SECURING POWER TO THE GALLEYS). FLIGHT CONTINUED TO MIA AND LANDED WITH NO FURTHER INCIDENT. MAINTENANCE REPLACED BOTH AFT CSDR DLM88970725Coffeemaker · failedOUTBOARD COFFEEMAKER IN AFT GALLEY STARTED SMOKING, C/B PULLED. INSPECTED AREA, REPLACED COFFEEMAKER AND OPS CKS OK.SDR TWAA9751001Coffeemaker · failedSTL - FLT 619 - DURING CRUISE, COFFEEMAKER EMITTED SMOKE. REMOVED AND REPLACED WORN COFFEEMAKER, MFG P/N 50198A, MANUFACTURED BY NORDSKOG INDUSTRIES, INC. OPERATIONAL CHECK NORMAL. (M)SDR TWAA9750002Oven · dirtyLGA - FLT 45 - DURING CRUISE, AFT GALLEY OVEN EMITTED SMOKE INTO PASSENGER CABIN. CLEANED FOOD DEBRIS FROM OVEN AND OPERATIONAL CHECK OF ALL AFT GALLEY OVENS NORMAL. (M)SDR DLM88970656Oven · dirtyUPON LEVELING AT FL 330, SMELLED SMOKE, SIMILAR TO FOOD BURNING IN OVEN. OVENS HAD BEEN TURNED ON DURING CLIMB-OUT. FWD AND AFT LAV SMOKE ALARMS WENT OFF. TURNED OVENS OFF AND SMOKE DISSAPATED, ALARMS SILENCED. REPOSITIONED LOOSE SEAL ON AFT GALLEY OVEN DOSDR CA970624012Hotcups · arcing(CAN) SERIOUS SPARKS FROM HOTCUPS IN L-4 GALLEY WITH SOME ARCING AS WELL. FLIGHT ATTENDANT REPORTED ARCING WHEN #1 HOTCUP INDICATOR LIGHT SOCKET PUSHED IN. L-4 GALLEY HOTCUPS TIMERS AND RECEPTACLES CHANGED.SDR DL757970652Oven · dirtyFWD GALLEY FWD OVEN CAUSES ODOR OF HOT INSULATION. SET OFF F/C LAV SMOKE ALARM AND CAUSED FUMES IN COCKPIT. INSPECTED OVENS, REMOVED BURNED STRING FROM FWD F/C OVEN AND RAN BOTH, CK OK NO ODOR NOTED.SDR 97UAL900275Oven Controller · inoperativeFWD GALLEY OVEN OVERHEATED AND PRODUCED SOME SMOKE. *S/D* REPLACED OVERHEATED OVEN AND CONTROLLER.SDR AWXA9700228Oven · smokingPIREP REPORT, NUMBER 1 OVEN IN FWD GALLEY PRODUCED SMOKE. INSPECTED AND FOUND NO DEFECTS.SDR AALA970726Oven · needed cleaningMXP - FLT 96 - EN ROUTE ORD-MXP - DURING CRUISE, F/C GALLEY NR 1 OVEN PRODUCED SLIGHT SMOKE WHEN HEATED. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED MXP, LANDING WITHOUT INCIDENT. CHECK OF THE OVEN REVEALED HEATING ELEMENT VERY DIRTY. PLACARDED F/CSDR TAOA049703Coffeemaker · shortedON FLT 6100, THERE WAS A STRONG SMELL OF ELECTRICAL SMOKE IN THE FORWARD GALLEY AREA. CREW PULLED ALL C/B'S FOR THE GALLEY AND LAV'S, SMELL DISIPATED. INSPECTION FOUND NR 1 COFFEEMAKER WITH TWO SHORTED WIRES AT H20 HEATER. REPLACED NR 1 COFFEEMAKER OPERATIOSDR CA970505016Motor · burnt(CAN) 10 MINUTES AFTER TAKEOFF, FLIGHT ATTENDANT REPORTED GALEY SMOKE. CIRCUIT BREAKER PULLED, FIRE EXTINGUISHER USED. RH GALLEY OVEN POSITION CAVITY LEFT HAND FAN MOTOR BURNT. REPLACED OVEN.SDR DLM11970602Warming Plate · failedSMELL OF BURNING PLASTIC/INSULATION IN B/C CENTERLINE WARMING PLATE UPPER UNIT.SDR DLM88970572Oven · smokingAFTER TAKEOFF, FWD GALLEY OVEN STARTED SMOKING, FLT ATT REPORTED SMOKE WAS WHITE. GALLEY TURNED OFF, CB PULLED AND SMOKE STOPPED.SDR DLL14970514Oven · malfunctionedF/C OVENS OVERHEATS CAUSED SMOKE ALARM IN LAV TO GO OFF. REPLACED OVEN ASSY, CHECKS GOOD.SDR DLL17970500Chiller · failedSMOKE AND FUMES IN CABIN AND COCKPIT SMELL OF SULFUR/ELECT. IN REAR OF CABIN AND 1ST CLASS AREA. SMELL ALSO IN COCKPIT. SECURED GALLEY POWER AND OPEN OUTFLOW VALVES/SMOKE SEEMED TO CLEAR. FOUND FWD CHILLER IN B/C GALLEY VENTING BURNT SMELL INTO CABIN. COLLSDR SCNA97061Coffeemaker · dirtyDURING FLIGHT, THERE WAS AN ELECTRICAL SMOKE SMELL IN THE AFT GALLEY. TURNED GALLEY POWER OFF AND SMELL WENT AWAY. FOUND NUMBER 7 COFFEE MAKER BASE DIRTY, CLEANED BASE AND OPS CHECKED GOOD.SDR CA970318022Oven · electrical smell(CAN) STRONG ELECTRICAL BURNING SMELL DETECTED IN GALLEY AREA. ALL OVEN POSITIONS CHECKED FOR VOLTAGE AND OPERATION. ALL OTHER ELECTRICAL UNITS OPERATED. NO SMELL DETECTED, NO FAULT FOUND, GALLEY ELECTRICAL SYSTEM CONSIDERED SERVICEABLE.SDR CA970318023Elect Receptacle · electrical shock(CAN) FLIGHT ATTENDANT RECEIVED ELECTRICAL SHOCK WHEN PULLING FOOD CART OUT FROM POSITION #17. ELECTRICAL POWER AND GROUND CHECKED AT RECEPTACLE. NO FAULT FOUND. RECEPTACLE REMOVED FROM BRACKET, WIRING AND GROUND STRAP CHECKED AND FOUND SERVICEABLE. RECEPTACLESDR 97UAL900141Trash Can · fireSMOKE REPORTED IN TRASH CAN OR SHELF AREA OF AFT GALLEY. *S/D* OPERATIONALLY CHECKED ALL GALLEY EQUIPMENT AND ELECTRICAL CONNECTORS, NO FAULT FOUND.SDR CA970318019Terminal Block · wet(CAN) FLIGHT ATTENDANT RECEIVED SHOCK FROM #1 HOT CUP IN REAR GALLEY. FOUND TERMINAL BLOCK WET LEFT SIDE OF GALLEY 5. DRIED AND SINK RESEALED.SDR 97ZZZM535Oven · overheatedIND - COMING FROM 'NIP' A FIRE DEVELOPED IN OVEN NR 6 DUE TO SHORTED ELEMENT, CIRCUIT BREAKER WAS PULLED. FIRE EXTINGUISHED. REMOVED AND REPLACED OVEN IAW LOCKHEED L1011 MM CHAPTER 25, PERFORMED OPERATIONS AND CHECKED GOOD. (M)SDR DL76L970240Coffeemaker · failedAFT GALLEY ELECTRICAL SMELL REPORTED BY FLIGHT ATTENDANT. REPLACED COFFEEMAKER.SDR AU970085Oven · failed(AUS) OVEN INSERT JAMMED AGAINST FAN. INVESTIGATION FOUND THAT THE LOCATING PEGS WERE MISALIGNED AND NOT LOCATING IN RECEPTACLES.THE FOOD OVERHEATED CAUSING SMOKE. PERSONNEL/MAINTENANCE ERRORSDR TWAA9716001Coffeemaker · overheatedSTL - DURING DESCENT, EMERGENCY LANDING WAS DECLARED DUE TO ELECTRIAL ODOR. REMOVED AND REPLACED FIRST CLASS COFFEEMAKER, MFG P/N 50198A. OPERATIONAL CHECK NORMAL. (M)SDR DL757970171Coffee Jug · odorBURNING SMELL AT GALLEY AT DOOR 2L-FORWARD FACING GALLEY. REPLACED FORWARD FACING COFFEE DISPENSER-NO SMELL NOTED-CHKS OK.SDR AALA970175Roller Tray · corrodedTUL - RIGHT INBOARD GALLEY ROLLER TRAY HAS AREAS OF CORROSION. INSTALLED NEW SECTION OF ROLLER TRAY PER SRM 53-70-00 FIG 8. (M)SDR TWAA9701301Warmer Pad · dirtyLAX - FLT 443 - DURING CRUISE, HAD A BURNED ODOR EMITTING FROM AFT GALLEY SERVICE AREA. TURNED OFF COFFEEMAKER. FOUND SPILLED COFFEE ON WARMER PAD, MFG P/N 5541. CLEANED WARMER PAD. COFFEEMAKER AND WARMER PAD OPERATION CHECKED NORMAL. (M)SDR SWAA970138Coffeemaker · failedNOTED ELECTRICAL ODOR SMELL AT AFT GALLEY. INSPECTED AND FOUND ODOR EMITTING FROM AFT GALLEY UPPER COFFEEMAKER. DEACTIVATED COFFEEMAKER AND CONTINUED.SDR DL76L970113Coffeemaker · failedSTRONG ELECTRICAL SMELL IN AFT GALLEY, UNABLE TO ISOLATE. PULLED ALL C/B IN GALLEY, STRENGTH OF SMELL CYCLED. SUSPECT CHILLER. INSPECTED OVENS/CHILLERS/CM. STRONG SMELL COMING FROM NR 1CM F/O SIDE. REPLACED COFFEEMAKER, OPS CK OK.SDR CA970203014Thermal Strips · fused(CAN) IN CRUISE CREW REPORTED SMOKE FROM COFFEE MAKERS GALLEY L3 POSITION FOUND OUTBOARD COFFEE MAKER CIRCUIT BREAKER POPPED AND PULLED INBOARD CIRCUIT BREAKER NO FURTHER SMOKE AN OVERHEAT CONDITION OF THE OUTBOARD COFFEE MAKER THERMAL STRIPS DE FUSED AND A WSDR TWAA9701001Serving Cart · overheatedSTL - FLT 161 - DURING CRUISE SERVING CART, S/N 0074, OVERHEATED. DISCONNECTED SERVING CART. FOUND SHORTED HEATING PADS. REPLACED SERVING CART, MFG P/N 88801-1. SERVING CART OPERATION THEN CHECKED NORMAL. (M)SDR CA970129005Receptacle · shorted(CAN) ELECTRICAL SMELL DETECTED IN FLIGHT DECK. MAINTENANCE TROUBLESHOOTING FOUND #4 OVEN RECEPTACLE BURNT. OVEN RECEPTACLE REPLACED AND CHECKED SERVICEABLE.SDR TWAA9709001Serving Cart · malfunctionedLAX - FLT 849 - DURING CRUISE AISLE SERVING CART EMITTED SMOKE. DISCONNECTED SERVING CART. FOUND MALFUNCTIONING HEATING PADS IN SERVING CART, MFG P/N 953000-119. REPLACED AISLE SERVING CART. SERVING CART OPERATION THEN CHECKED NORMAL. (M)
Back to JASC 2530