SDR 96ZZZX4912Coffeemaker · malfunctionedSTL - FLT 247 - AFTER TAKEOFF, GALLEY COFFEEMAKER EMITTED SMOKE AND NOXIOUS FUMES. TURNED OFF GALLEY. FOUND COFFEEMAKER SOLENOID MALFUNCTIONING. REPLACED COFFEEMAKER, MFG P/N 50198A. GALLEY AND COFFEEMAKER OPERATION CHECK NORMAL. CHECK C - 8-21-96 - STL.SDR CA961001010Oven · acrid odour(CAN) PRIOR TO DEPARTURE, BURNING ODOUR PRESENT IN GALLEY. ELECTRICAL RECEPTACLES CHECKS OK. OVEN REPLACED.SDR 96ZZZX4905Oven · smokingSTL - FLT 224 - DURING CRUISE, GALLEY OVEN EMITTED SMOKE. SHUT OFF OVEN. FOUND SPILLED FOOD IN OVEN. CLEANED OVEN AND OVEN OPERATION CHECKED NORMAL. CHECK C-1D - 5-16-96 - JFK.SDR 96ZZZX4904Wire · burnedJFK - FLT 925 - DURING CRUISE, ELECTRICAL ARCING AND SMOKE WAS EMITTED FROM WORK LIGHT WIRING AT B-GALLEY COFFEEMAKER. SHUT OFF GALLEY ELECTRICAL POWER. FOUND CHARRED ELECTRICAL WIRING INSULATION. REPAIRED W0RK LIGHT AND GALLEY POWER OPERATION CHECKED NORMALSDR 96ZZZX5315Oven · smokingJFK - FLT 903 - DURING CRUISE FIRST CLASS GALLEY OVEN 1-6 EMITTED SMOKE. TURNED OFF OVEN. FOUND FOOD SPILLAGE IN OVEN. CLEANED OVEN, OVEN OPERATION THEN CHECKED NORMAL. CHECK C-2 - 6-22-96 - MZJ.SDR DL767961965Coffee Maker · faultyTHE F/C NR 2 COFFEE MAKER STARTED SMOKING WHEN BREW BUTTON WAS PRESSED. SMOKE STOPPED AFTER CIRCUIT BREAKER PULLED. REPLACED COFFEE MAKER. SYSTEM CHECK GOOD.SDR GTIA96NK204Coffee Maker · failedTRANSFERRED FROM CABIN DISCREPANCIES LOG ITEM 1 'COFFEE POT SMELLS LIKE ITS BURNING AND WARMER BUTTON IS STUCK IN THE ON POSTION.' DEFERRED COFFEE MAKER IAW MEL 25-12 DMI 5006 CATD PLACARDED. LOG PAGE 028771. REMOVED AND REPLACED COFFEE MAKER CLEARED 5006 PSDR GTIA96NK192Coffee Maker · failedAFTER BLOCKING INTO ACY, FLIGHT ATTENDANT REPORTED A BURN SMELL COMING FROM THE AREA OF THE COFFEE MAKER. FOUND COFFEE POT WARMER BUTTON STUCK ON 'IN' POSITION. CLEANED AND FREED BUTTON, NO OTHER SMELL IN AREA. (M)SDR CA960910031Receptacle · shorted(CAN) ELECTRICAL BURNING SMELL DETECTED IN GALLEY AREA. ODOUR DISSIPATED AFTER GALLEY CB PULLED. CHECK OF EQUIPMENT REVEALED OVEN RECEPTACLE #18 WAS SHORTED. OVEN RECEPTACLE CHANGED.SDR 96ZZZM1366Oven · smokingJFK - DURING CRUISE, GALLEY OVEN EMITTED SMOKE. SHUT DOWN OVEN. FOUND DEFECTIVE FAN MOTOR. REPLACED OVEN, MFG P/N 5316E. OVEN OPERATION THEN CHECKED NORMAL.SDR 96ZZZX5183Oven · smokingJFK - FLT 925 - DURING CRUISE, AUXILIARY BAR OVEN EMITTED SMOKE AND BURNING ODOR. TURNED OFF OVEN. FOUND OVEN, MFG PN 5852, DEFECTIVE. REPLACED AUXILIARY BAR OVEN. OPERATION THEN CHECKED NORMAL. CHECK C-2 - 7-12-96 - JFK.SDR 96UAL900617Oven · failedTHE GALLEY OVEN WAS SMOKING AND SPARKING. THE OVEN WAS REMOVED FROM THE AIRCRAFT AND RETURNED TO THE SHOP. THE B-PHASE OVEN HEATING ELEMENT WAS FOUND INOPERABLE DURING OVERHAUL.SDR 96ZZZM1364Warming Pad · smokingSTL - DURING CRUISE, D-GALLEY COFFEEMAKER WARMING PAD EMITTED SMOKE. REMOVED AND REPLACED COFFEEMAKER, MFG P/N 412-0001-1. OPERATIONAL CHECK NORMAL.SDR 96ZZZM1312Galley Cart · not latchedFLT NR 7 ATLANTA TO NEWARK - RUNAWAY SERVICE CART FROM AFT GALLEY BROKE THROUGH COCKPIT DOOR ON LANDING ROLLOUT. INSPECTED AFT GALLEY, LATCHES AND GALLEY CART. FOUND ALL OK FOR SERVICE. REMOVED AND REPLACED COCKPIT DOOR. GALLEY CART REMOVED PRECAUTIONARY. SDR CALA9601112Oven · fireSMOKE BEGAN COMING FROM AFT GALLEY OVENS WHILE EN ROUTE. A FIRE EXTINGUISHER WAS USED TO EXTINGUISH OVEN FIRE. THE AIRCRAFT WAS RETURNED TO IAH WHERE IT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED AFT GALLEY OVENS AND FOUND PAPER BURNED INSIDE OF OVENS. SDR 9616199968Terminal Block · meltedFLIGHT ATTENDANT REPORTED THAT FORWARD GALLEY COFFEEMAKER HAD NO POWER. MAINTENANCE INSPECTED WIRING AND FOUND WIRING AND TERMINAL BLOCK TO COFFEEMAKER MELTED. DEFERRED COFFEEMAKER AND COLLARED CIRCUIT BREAKER. AWAITING PARTS FOR TERMINAL BLOCK REPLACEMENT.SDR 96UAL900550Oven · smokingUSED FIRE EXTINGUISHER FOR SMOKE AND FUMES FROM GALLEY OVEN. FOUND MELTED PLASTIC MATERIAL ON HEATING ELEMENT GRILL IN OVEN. OVEN OPERATED NORMALLY AFTER PLASTIC MATERIAL WAS REMOVED.SDR DL76S961699Coffee Maker · failedTEN MINUTES AFTER FLIGHT ATTENDANT REPORTED ELECTRICAL SMOKE SMELL IN RIGHT GALLEY, BOTH MID AND AFT CABIN LAV SMOKE DETECTORS ACTIVATED IN FLT. NO DETECTABLE SMOKE OR FIRE, TURNED UTILITY BUSES OFF FOR REMAINDER OF FLT. REPLACED INBD COFFEE MAKER MID GALLESDR GTIA96NK178Water Line · looseCOFFEE MAKER SMOKING AND SPARKS COMING OUT FROM BACK. FOUND DE-ACTIVATED WATER LINE SPARKING AGAINST TERMINAL END. RE-POSITIONED AND SECURED LINE. (M)SDR 96ZZZM1216Serving Cart · failedSTL - DURING CRUISE, SINGLE SERVING CART CONNECTOR EMITTED SMOKE AND CIRCUIT BREAKER POPPED. TURNED OFF SERVICING CART AND DISCONNECTED CONNECTOR. FOUND INTERNAL MALFUNCTION IN SERVING CART, MFG P/N 88801-1, CONNECTOR. REPLACED SERVING CARGO AND OPERATION TSDR TWRA96142Trash Can · fireDURING CRUISE, FLIGHT ATTENDANT FIRED L-5 HALON FIRE EXTINGUISHER INTO THE AFT DRY GALLEY TRASH RECEPTACLE DUE TO AN APPARENT FIRE. IT IS BELIEVED TO BE CAUSED BY A PASSENGER'S CIGARETTE. INSPECTED AREA, FOUND NO DAMAGE. REPLACED FIRE EXTINGUISHER BOTTLE. SDR 96UAL900509Terminal Strip · damagedAN ELECTRICAL SMOKE ODOR OCCURRED IN THE AFT GALLEY. *S/D* A LOOSE TERMINAL CAUSED THIS DISCREPANCY. THE TERMINAL STRIP FOR THE AFT CART CABLE ON RIGHT SIDE WAS REPLACED, OPERATIONS CHECK NORMAL.SDR DL757961560Coffee Maker · failedACFT DIVERTED INTO ABQ DUE TO ELECTRICAL SMELL IN THE AFT GALLEY. MTC FOUND COFFEE MAKER AT FAULT AND RENDERED INOP.SDR DLL13961508Oven · fireCUP COVERING EGGS IN OVEN CAUGHT FIRE IN NR 1 OVEN. FIRE EXT WITH HALON EXT.SDR AALA960955Chiller · dirtyLHR - FLT 142 - EN ROUTE JFK/LHR DURING CRUISE, AFT B-C GALLEY CHILLER MADE NOISES AND SLIGHT SMOKE NOTED. TURNED OFF POWER TO AFT B-C GALLEY CHILLER AND AIRCRAFT PROCEEDED TO LHR, LANDING WITHOUT INCIDENT. PLACARDED AFT B-C GALLEY CHILLER INOPERATIVE. SUBSSDR CALA9600842Oven · contaminatedSMOKE WAS OBSERVED COMING FROM THE FORWARD GALLEY WHILE EN ROUTE. THE FORWARD OUTBOARD OVEN WAS FOUND TO BE EXTREMELY HOT. THE OVEN CIRCUIT BREAKERS WERE DEACTIVATED AND THE SMOKE CEASED. THE AIRCRAFT WAS DIVERTED TO GSO WHERE IT LANDED WITHOUT INCIDENT. MSDR AALA960938Warming Cart · failedLHR - FLT 116 - EN ROUTE JFK/LHR DURING CRUISE, SLIGHT SMOKE NOTED IN B/C GALLEY WHEN WARMING CART AND OVEN TURNED ON. TURNED OFF B/C GALLEY WARMING CART AND OVEN AND AIRCRAFT PROCEEDED TO LHR, LANDING WITHOUT INCIDENT. WARMING CART REPLACED BY CATERING AND BSDR CALA9600840Oven · contaminatedTHE FLIGHT ATTENDANT SAW SMOKE COMING FROM RT OVEN IN FORWARD GALLEY WHILE IN FLIGHT. THE SMOKE CEASED AFTER USING A HALON AND WATER FIRE EXTINGUISHER AND PULLING THE CIRCUIT BREAKERS FOR THE RIGHT AND LEFT FORWARD OVENS. THE FLIGHT WAS CONTINUED WITHOUT FURSDR CA960723546Elect Receptacle · malfunction(CAN) PRIOR TO DEPARTURE, BURNING SMELL DETECTED IN GALLEY AREA. OVENS AND ELECTRICAL OUTLET CHECKED.SDR CA960723545Timer Seized · burning smell(CAN) AFTER TAKEOFF, ELECTRICAL BURNING SMELL DETECTED IN FORWARD GALLEY. MAINTENANCE CHECK REVEALED HOT CUP TIMER WAS TEMPORARILY SEIZED. ELECTRICAL POWER AT HOT CUP AND TIMER OUTLET OPERATIONALLY CHECKED.SDR AALA960910Mount · corrodedAFW - FOUND G-7 GALLEY MOUNT HAD CORROSION BEYOND MM LIMITS. BLENDED CORROSION, FABRICATED REPAIR FITTING PE MRB 767-1254. (M)SDR 96UAL900412Oven · burnt odorCREW REPORTED, AFT GALLEY AREA HAS A BURNT SMELL. *S/D* OPERATED COFFEE MAKERS, NO DISCREPANCY OR SMELL NOTED. GALLEY MODULES REMOVED AT LAS. REPLACEMENT OVEN MODULE OPERATED NORMALLY. SUSPECT INBOUND OVEN MODULE, BUT CAUSE UNKNOWN.SDR 96UAL900407Switch · failedGALLEY OVEN SMOKING, SPARKING WHEN ON. SMOKE COMING FROM HEATER ON LIGHT. *S/D* FOUND SHORT CIRCUIT IN HEATER ON SWITCH. PROBABLY CAUSED BY MOISTURE IN SWITCH. REPLACED SWITCH, CLEANED OVEN AND CHECKS OK.SDR DL757961340Oven · failedAT CRUISE, F/A REPORT ODOR OF OVERHEATED PLASTIC SMELL AT MID-GALLEY. ODOR PARTICULARLY STRONG AT MID-GALLEY VENT. REMOVED ALL POWER AND ODOR DISSIPATED IN APPROXIMATELY 1 HOUR. INSPECTED AREA FOR SHORTS AND CHAFES - N0NE NOTED. REPLACED SUSPECTED OVERHEATSDR 96ZZZM1067Serving Cart · failedJFK - DURING CRUISE, SINGLE SERVING CART NR 412, OVERHEATED AND EMITTED SMOKE. DISCONNECTED ELECTRICAL POWER. FOUND DEFECTIVE HEATING PAD. REPLACED SERVING CART, MFG P/N 953000-119. NEW SERVING CART OPERATION CHECKED NORMAL.SDR DL757961322Coffee Maker · overheatedFLIGHT ATTENDANTS REPORTED SMOKE COMING FROM AREA AROUND THE AFT COFFEE MAKER IN THE FIRST CLASS GALLEY. SMOKE DID NOT SEEM TO STOP WHEN THEY PULLED THE CIRCUIT BREAKER IN THE GALLEY. PULLED CIRCUIT BREAKERS S-32 AND S-33 ON THE P-11 PANEL. SMOKE SEEMED TO SDR CA960723532Oven · smoking(CAN) BOTH CLASS GALLEY OVENS SMOKING ON TAKEOFF. SMOKE CAUSE BY SPILLED FOOD ON OVEN ELEMENTS. OVENS CLEANED.SDR CALA9600645Coffeemaker · failedTHE NR 2 COFFEEMAKER IN FORWARD GALLEY BEGAN TO SMOKE DURING PUSHBACK FROM GATE. THE AIRCRAFT WAS RETURNED TO THE GATE. MAINTENANCE FOUND THE NR 2 COFFEEMAKER PRINTED CIRCUIT CARD BURNED. THE COFFEEMAKER WAS REMOVED AND REPLACED, OPERATION CHECKED GOOD.SDR SCNA96150Coffee Maker · smokingAFT GALLEY LEFT HAND COFFEE MAKER STARTED SMOKING. PULLED CIRCUIT BREAKER AND SECURED AFT GALLEY BUS. REMOVED AND REPLACED THE LEFT HAND AFT COFFEE MAKER.SDR AALA960846Mount · corrodedAFW - FOUND G6 GALLEY MOUNT HAS CORROSION ON INBOARD VERTICAL AND HORIZONTAL SURFACE BEYOND SRM LIMITS. REMOVE EXISTING CORROSION, FABRICATE REPAIR FITTING PER ENGINEERING MRB 767-1230.SDR 96ZZZM1040Oven · dirtyJFK - DURING CRUISE E6 OVEN EMITTED SMOKE. TURNED OFF OVEN. FOUND DEBRIS IN OVEN. REPLACED OVEN, MFG P/N 8201-11-0000. OVEN OPERATION THEN CHECKED NORMAL.SDR CA960723555Elect Receptacle · cabin elect odor(CAN) ACUTE ACCRID ELECTRICAL ODOUR COMING FROM THE GALLEY, OVENS SWITCHED OFF. OVEN RECEPTACLES CHECKED AND GALLEY POWER AND EQUIPMENT CHECK CARRIED OUT.SDR DLM11961210Oven · malfunctionedOVEN NR 307 IN AFT GALLEY WOULD NOT TURNED OFF WITH SWITCH. PULLED C/B'S TO ALL TO STOP OVERHEATING. IT WAS GIVING OFF A BURNING ODOR AND VERY HOT. ATL MTC NOTIFIED.SDR SCNA96151Oven · smokingWHILE OFF, SMOKE STARTED TO COME OUT OF LATCHING MECHANISM ON OVEN NR 3. CIRCUIT BREAKERS WERE PULLED AND GALLEY POWER WAS TURNED OFF. RESET CIRCUIT BREAKER ON BACK OF OVEN. OPS CHECK NORMAL, NO SIGN OF SMOKE.SDR CA960528102Coffee Maker · burnt(CAN)AFT GALLEY COFFEE MAKER SPARKING AND FLASH FOLLOWED BY SMOKE. CBS PULLED AND UNIT REPLACED.SDR 96DHL802004Light Socket · failedELECTRICAL SMOKE IN GALLEY FROM HOT CUP LIGHT. REMOVED AND REPLACED HOT CUP LIGHT SOCKET, CHECK OK PER M/M 25-20.SDR DL767961161Coffeemaker · failedSMOKE IN REAR GALLEY REPORTED COMING FROM AIR VENT. INSPECTED AFT GALLEY AREA AND ABOVE CEILING AREA FOR EVIDENCE OF BURNING OR SMELL, NONE FOUND AND ALL WIRING OK. REMOVED NR 3 AND NR 4 COFFEEMAKERS AND INSPECTED WIRING HARNESS FOR CONDITION, ALL OK, SLIGHTSDR CA960723521Elect Receptacle · burnt(CAN) ELECTRICAL BURNING SMELL DETECTED IN OVEN GALLEY AREA. MAINTENANCE CHECK FOUND OVEN #2, POSITION 16 ELECTRICAL RECEPTACLE BURNT. RECEPTACLE CHANGED.SDR USAASB96086Relay · failedFLT 1886 - ORF - AT 19,000, THERE WAS AN ACRID, ELECTRICAL ODOR, WITH VERY LIGHT SMOKE, LASTED 3 MINUTES. DIVERTED TO ORF. MX FOUND R-61 RELAY AT L1 TERMINAL BURNED FOR NR 1 GALLEY. REPLACED R-61 RELAY AND L1 TERMINAL END. OPS CHECKS NORMAL. (M)SDR 96ZZZM1035Oven · dirtySTL - DURING CRUISE, FORWARD GALLEY OVEN OVERHEATED AND EMITTED SMOKE. TURNED OFF OVEN. FOUND DEBRIS AND SPILLED FOOD IN OVEN, MFG P/N 5616E. CLEANED OVEN AND OPERATION NORMAL.
Back to JASC 2530