Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WWMA9700006Hot Jug · odorFLIGHT ATTENDANT REPORTED, AN ELECTRICAL SMELL FROM THE NR 2 HOT JUG. MAINTENANCE INSPECTED CABIN FLUORESCENT LAMP SOCKETS, HOT JUGS AND HOT JUG RECEPTICLES. COULD NOT DUPLICATE BUT DID FIND NR 2 HOT JUG TO CONTAIN EXTREMELY BAD SMELLING COFFEE. SUSPECT ODOSDR 97ZZZX998Oven · fireA SMALL FIRE INSIDE NR 2 OVEN OCCURRED DURING CRUISE OF FLT 5118. CABIN CREW EXTINGUISHED THE FIRE USING A HALON FIRE EXTINGUISHER. NO OTHER EMERGENCY PROCEDURES WERE REQUIRED. SOURCE WAS UNDETERMINED. IT IS SUSPECTED TO BE COMBUSTIBLE MATERIAL IN OR ON A SDR WWMA9700005Recepticle · defectiveFLIGHT ATTENDANT REPORTED, A BURNING SMELL FROM THE HOT JUG AREA. WORK STATION SWITCHES WERE SHUT OFF AND CIRCUIT BREAKERS M25 AND M27 WERE PULLED. MAINTENANCE INSPECTED ALL CABIN FLUORESCENT LAMP SOCKETS, RECIRCULATION FANS AND THE HOT JUG RECEPTICLES. FOSDR TWAA9704001Serving Cart · failedJFK - FLT 843 - DURING CRUISE SINGLE SERVE FOOD CART, MFG P/N 88801-1, EMITTEDSMOKE WHEN TURNED ON. REMOVED AND REPLACED CART WITH A SERVICEABLE CART. (M)SDR AALA970045Roller Tray · corrodedTUL - FOUND CORROSION ON RIGHT OUTBOARD ROLLER TRAY, NUMEROUS PLACES STATION 1581 TO 1701. REMOVED AND REPLACED RIGHT OUTBOARD ROLLER TRAY PER SRM 51-21-00. (M)SDR TWAA9703002Food Cart · failedLAX - FLT 443 - DURING CRUISE SINGLE SERVE FOOD CART NR 1479, P/N 88801-1 SMOKED WHEN TURNED ON. REMOVED AND REPLACED CART NR 1479, WITH A SERVICEABLE CART. (M)SDR MWEA97002Oven · smokingCREW REPORTS, RIGHT OVEN SMOKED EXCESSIVELY WHEN TURNED ON. MAINTENANCE REMOVED AND REPLACED OVEN, OPS CHECK GOOD.SDR DL757962790Food Carrier · dirtyRETURNED AFTER TAKEOFF WITH SMOKE SMELL IN CABIN. FOUND PROBLEM TO BE MASKING TAPE LEFT ON FOOD CARRIER BY CATERER. TAPE GAVE OFF ODOR WHEN MEALS HEATED. NO MAINTENANCE ACTION NECESSARY.SDR TWAA9615903Serving Cart · failedJFK - FLT 782 - DURING CRUISE, AISLE SERVING CART OVERHEATED AND EMITTED SMOKE. DISCONNECTED SERVING CART. FOUND SHORTED HEATING ELEMENTS. REPLACED SERVING CART, MFG P/N 953008-119. SERVING CART OPERATION THEN CHECKED NORMAL. (M)SDR WWMA9600108Plug · arcedCREW REPORTED AN UNUSUAL ODOR EMMITTING FROM THE HOT WATER JUGS. MAINTENANCE FOUND THE NR 1 HOT JUG ELECTRICAL PLUG ARCED, SYSTEM WAS DEACTIVATED AND DEFERRED DUE TO TIME TO REPLACE THE PLUG.SDR CA970109025Elect Socket · broken wire(CAN) ON DESCENT, STRONG ELECTRICAL SMELL COMING FROM FORWARD GALLEY. GALLEY POWER TURNED OFF. TROUBLESHOOTING REVEALED GALLEY OVEN UNIT PIN #3 ON RECEPTACLE WIRING SHORTED. WIRE REPAIRED AND SOCKET REPLACED. CHECKED SERVICEABLE.SDR TWAA9615502Serving Cart · failedSTL - FLT 2 - DURING CRUISE, HAD A BURNING ODOR FROM AISLE SERVING CART, POSITION 1 IN 'B' GALLEY. FOUND DEFECTIVE AISLE SERVING CART, MFG P/N 8801-1. REPLACED AISLE SERVING CART. GALLEY AND SERVING CART OPERATION THEN CHECKED NORMAL. (M)SDR CA970109024Cooling Fan · inoperative(CAN) ELECTRICAL SMOKE FUMES IN FRONT OF GALLEY AREA DURING DESCENT. GALLEY POWER REMOVED AND SMELL DISSIPATED. MAINTENANCE TROUBLESHOOTING REVEALED RH COOLING FAN INOPERATIVE POPPING CIRCUIT BREAKER. DEFECTIVE FAN REPLACED AND OPERATIONALLY CHECKED SERVICEABLSDR CA970109028Compressor · failed(CAN) SMOKE REPORTED IN REAR GALLEY. GALLEY POWER UTILITY BUS LH AND RH SWITCHED OFF. UNIT COOLED AND SMOKE DISSIPATED. HOT SPOT BEHIND GALLEY POSITION 104. WHEN LH UTILITY BUS ON, HOT SPOT RE-OCCURRED. LH UTILITY BUS SWITCHED OFF, GALLEY POWER OFF, RH UTILITYSDR TWAA9615102Oven · failedSTL - FLT 222 - DURING DESCENT, HAD ELECTRICAL ODOR IN AFT CABIN. PULLED CIRCUIT BREAKER FOR AFT GALLEY OVENS. FOUND OVEN, MFG PN 50381, WITH INTERNAL MALFUNCTION. REPLACED OVEN. OVEN OPERATION THEN CHECKED NORMAL. CHECK C-1D - 5-28-96 - JFK. (X)SDR 96UAL900926Oven · damagedRETURNED TO BOS DUE TO SMOKE IN COCKPIT. *S/D* STRONG SMOKE ODOR AND ELECTRICAL SMELL CAME FROM FORWARD GALLEY AREA. SMOKE COMING FROM INSIDE OVEN. FOUND COOKIE CONTAINER LIDS CHARRED. REPLACED OVEN AND CONTROLLER, GALLEY MODULE OPERATION NORMAL.SDR 9626062707Oven · smokingDURING CLIMB, FLIGHT ATTENDANT REPORTED SMOKE COMING FROM FIRST CLASS GALLEY OVENS. AIRCRAFT DUMPED FUEL AND RETURNED TO FLL AND LANDED WITHOUT INCIDENT. MAINTENANCE DEACTIVATED FIRST CLASS GALLEY OVENS BY PULLING CIRCUIT BREAKERS. OVENS WERE PLACED ON MEL.SDR 96UAL900918Coffeemaker · overheatedELECTRICAL BURNING SMELL IN AFT GALLEY. *S/D* BURNING SMELL ISOLATED TO AFT LOWER COFFEEMAKER. REPLACED COFFEEMAKER.SDR TWAA9614602Controller · failedSTL - FLT 104 - DURING CRUISE, AISLE WARMER CART EMITTED ELECTRICAL ODOR AND SMOKE. FOUND FAULTY POWER CONTROLLER, MFG PN 91658-3. REPLACED WARMER CART CONTROLLER. WARMER CART OPERATION THEN CHECKED NORMAL. CHECK C-1C - 10-2-96 - LAX. (X)SDR WWMA9600095Recepticle · failedCLIP SECURING NR 2 HOT JUG IS TOO DIFFICULT TO TURN. ALSO, BURNING ODOR COMING FROM NR 2 HOT JUG AREA. LUBED CLIP AND REPLACED HOT JUG RECEPTICLE.SDR CA961125011Oven Fan · seized(CAN) REAR GALLEY OVEN #3 SMOKING AND ARCING. FIRE EXTINGUISHER USED IN AND ON TOP OF OVEN. FAN MOTOR SEIZED.SDR CA961125009Elect Receptacle · shorted(CAN) FLIGHT ATTENDANT REPORT SMOKE & SPARKS COMING FROM GALLEY OVEN AT POSITION #19. MAINTENANCE ACTION INVOLVED INSTALLING NEW RECEPTACLE AND OVEN CHECKED SERVICEABLE.SDR CALA9601627Oven · dirtyTHE AFT GALLEY OVEN BEGAN TO SMOKE WHILE AT CRUISE PORTION OF FLIGHT. THE AFT HALON FIRE EXTINGUISHER WAS USED IN AFT GALLEY OVEN AND THE SMOKE CEASED. BURNED PAPER PRODUCTS WERE FOUND INSIDE OVEN. MAINTENANCE FOUND NO DAMAGE TO OVEN AND NO DEFECTS WERE FOUSDR CA961118015Fan · overload(CAN) DIRECT CURRENT EMERGENCY BUS CAUTION LIGHT ON AT FL180 ON CLIMB OUT. AT SAME TIME CIRCUIT BREAKER C5 GALLEY FAN POPPED AND WOULD NOT RESET. CIRCUIT BREAKER R7 POPPED AS A RESULT OF CIRCUIT BREAKER C5 GALLEY EXHAUST FAN FAULT. FAN REPLACED.SDR QXEA9600458Coffee Warmer · shortedBURNING SMELL COMING FROM THE NUMBER TWO COFFEE WARMER. REPLACED COFFEE WARMER AND WARMER OPS CHECKED GOOD.SDR WWMA9600094Recepticle · failedHOT WAX SMELL COMING FROM LAV LIGHTING. NR 1 HOT JUG RECEPTICALE AIRFRAME SIDE MELTED. PULLED JUG OUT, COLLARED C/B FOR NR 1 HOT JUG, DEFFERED DUE TO TIME MEL 25-13 AUTHORAZATION NR 110056M CAT D.SDR CA961118008Elect Receptacle · shorted(CAN) FLIGHT ATTENDANT FELT ELECTRICAL SHOCK IN REAR GALLEY POSITION #527. HOT CUP RECEPTACLE REPLACED.SDR SWAA961196Coffeemaker · failedAT GATE, NOTED A BURNING ELECTRICAL ODOR AT AFT GALLEY AREA. INSPECTED GALLEY AREAS, REPLACED COFFEEMAKERS AND RESET BREAKERS PER M/M, ALL NORMAL.SDR CALA9601525Oven · inoperativeSMOKE BEGAN TO APPEAR FROM THE TOP OF THE NR 625 AFT GALLEY OVEN WHILE INFLIGHT. THE OVEN WAS TURNED OFF AND ASSOCIATED CIRCUIT BREAKERS WERE PULLED. THE SMOKE CEASED AND THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. MAINTENANCE PLACARDED THE NR 625 AFTSDR CALA9601527Oven · contaminatedTHE FLIGHT ATTENDANT REPORTED SMOKE COMING FROM THE NR 2 OVEN IN FIRST CLASS GALLEY WHILE INFLIGHT. THE OVEN CIRCUITS WERE DEACTIVATED AND THE SMOKE CEASED. THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND COOKING GREASE IN THE NR 2 FIRSTSDR CALA9601515Oven Fan · failedSMOKE APPEARED IN THE AFT GALLEY DURING TAXI OUT. THE AIRCRAFT WAS RETURNED TO THE GATE WITHOUT INCIDENT. MAINTENANCE FOUND THE NR 1 AFT GALLEY OVEN FAN FROZEN AND OVERHEATED. THE NR 1 AFT GALLEY OVEN WAS REMOVED AND REPLACED, OPERATION OF THE OVEN CHECKED SDR 96UAL900835Oven · fireA SMALL FIRE OCCURRED IN THE AFT GALLEY OVEN. *S/D* FOOD SPILLED ONTO THE BOTTOM OF THE OVEN INSERT RESULTING IN A SMALL FIRE. THE FIRE WAS EXTINGUISHED WITH A HALON FIRE EXTINGUISHER. THE OVEN WAS NOT DAMAGED AS A RESULT OF THIS INCIDENT, OPERATIONS CHECSDR CA961104013Oven Plug · burnt(CAN) DURING CRUISE AN ELECTRICAL BURNING SMELL WAS NOTICED COMING FROM THE FRONT AREA OF THE AIRCRAFT NEAR THE FLIGHT DECK. INVESTIGATION REVEALED PLUG OF GALLEY OVEN #4 BURNT. PLUG REPLACED.SDR CA961104014Hot Cup · elect short(CAN) FLIGHT ATTENDANT RECEIVED ELECTRICAL SHOCK FROM THE HOT CUP IN AFT GALLEY. LARGE SPARK SEEN IN GALLEY AREA. INVESTIGATION REVEALED HOT CUP RECEPTACLE DEFECTIVE. RECEPTACLE REPLACED.SDR DL757962316Coffee Maker · odorAFT GALLEY COFFEEMAKER CAPT SIDE CREATES A BURNT/TOXIC ODOR IN FLIGHT. REPLACED DISPENSER, LEAK CK GOOD AND OP CK NORMAL.SDR AWXA960594Coffeemaker · failedPHX - FLT 0001 - AFT COFFEEMAKER CIRCUIT BREAKER OUT. FLIGHT ATTENDANT PUSHED IT BACK IN AND SMELLED ELECTRICAL SMOKE. REPLACED COFFEEMAKER. (M)SDR SWAA961082Coffeemaker · inoperativeDURING DESCENT, NOTED A PLASTIC TYPE BURNING SMELL IN FWD GALLEY AREA. INSPECTED GALLEY COFFEEMAKERS, PULLED AND COLLARED C/B'S TO FWD GALLEY COFFEEMAKERS, NO OTHER DISCREPANCIES NOTED.SDR AALA961508Oven · dirtyLHR - FLT 106 - EN ROUTE JFK/LHR DURING CRUISE, FIRST CLASS GALLEY NR 2 OVEN HAD DIRTY INTERIOR CAUSING SMOKE WHEN OVEN DOOR WAS OPENED. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED TO LHR AND LANDED WITHOUT INCIDENT. CLEANED INTERIOR OF FIRST CLASS SDR DL76S962242Oven · sparkingNR 1 UPPER OVEN MADE A LOUD POP AND SPARKS FLEW WHEN TURNED ON. REPLACED OVEN.SDR DL76L962241Oven · overheatingOVEN AT AFT GALLEY DEFECTIVE, NR 7 OVEN CAUSING SIDEWALL TO GET HOT AND CURLING VINYL WALLPAPER. C/B PULLED AND OVEN SECURED. REPLACED OVEN, CHECKS OK.SDR CA961021014Socket · burnt(CAN) BIG SPARK FROM ORANGE LIGHT ON LEFT HOT CUP IN GALLEY #3 AREA AROUND BLACKENED AND HALF GALLEY SHUT DOWN, EXTINGUISHER USED, FULL INFLIGHT FIRE DRILL. HOT CUP LIGHT SOCKET BURNT, REPLACED.SDR DL76L962207Coffee Maker · shortedAT FL 330, 2.5 HRS INTO FLIGHT RIGHT AC BUS AND RIGHT BUS TIE ILLUMINATED, ALONG WITH NUMEROUS ASSOCIATED EICAS MESSAGES. AFTER RESETTING RIGHT GENERATOR, THE RIGHT AC BUS WAS RESTORED BUT THE ISLN LIGHT REMAINED ON. SHORTLY AFTER THAT THE FLIGHT ATTENDANTS SDR AWXA960541Oven · dirtyPHX - FLT 25 - INBOARD OVEN IN FORWARD GALLEY PRODUCED SMOKE WHEN TURNED ON TO HEAT MEALS. CLEANED FOIL FROM OVEN. OPERATES GOOD. (M)SDR 9620802769Oven · smokingDURING CLIMB, FLIGHT ATTENDANT REPORTED SMOKE COMING FROM AFT GALLEY OVENS. AIRCRAFT RETURNED TO MCO AND LANDED WITHOUT INCIDENT. REPLACED AFT GALLEY FORWARD OVENS. FAN AND HEATER ELEMENT GUARDS MISSING, OPERATIONAL CHECK OK.SDR DL757962184Coffee Maker · failedAFT GALLEY NR 1 COPILOTS SIDE COFFEE MAKER MAKES POPPING SOUND WITH SPARKS FLYING WHEN TURNED ON. CIRCUIT BREAKER DID NOT POP. REPLACED COFFEE MAKER.SDR WWMA9600079Hot Jug · failedFLIGHT ATTENDANT SMELLED AN ELECTRICAL BURNING ODOR COMING FROM THE GALLEY COMPARTMENT. ALSO, THE HOT JUG AREA IS UNUSALLY WARM. REMOVED AND DEFERRED HOT JUGS, SAFETY CLIPPED THE CIRCUIT BREAKER TO PREVENT USE OF GALLEY CIRCUITS.SDR DL76S962128Oven · smokingBOTTOM OVEN IN F/C GALLEY PRODUCING SMOKE. PULLED AND COLLARED OVEN CIRCUIT BREAKER. FORWARD ITEM TO MCO. REPLACED OVEN.SDR CA961001012Coffee Maker · elect short(CAN) CREW REPORTED BURNING SMELL COMING FROM COFFEE MAKER. COFFEE MAKER REPLACED.SDR 96ZZZX4913Serving Cart · smokingSTL - FLT 2 - DURING CRUISE, FOOD SERVING CARTS EMITTED SMOKE. TURNED OFF SERVING CARTS. FOUND SPILLED FOOD IN CARTS. REPLACED SERVING CARTS, MFG P/N 88801-1, AND OPERATION CHECKED NORMAL. CHECK C-2 - 6-15-96 - JFK.SDR AALA961328Oven · dirtyBRU - FLT 88 - EN ROUTE ORD/BRU DURING CRUISE, NR 2 OVEN EMITTED SMOKE WHEN DOOR OPENED. NO OTHER ABNORMAL INDICATIONS AND AIRCRAFT PROCEEDED TO BRU, LANDING WITHOUT INCIDENT. CLEANED INTERIOR OF NR 2 OVEN. SYSTEM GROUND CHECKED NORMAL OPERATION WITH NO SMO
Back to JASC 2530