SDR USAASB96084Ballast · failedFLT NR 1005 - MEM - AT CRUISE ALT AN ELECTRICAL SMELL DEVELOPED IN THE AFT GALLEY. CAPTAIN CONFIRMED UPON INSPECTION AND DIRECTED FA'S TO PULL ALL AFT GALLEY CIRCUIT BREAKERS. SMELL DISIPATED. DIVERTED TO MEM. MAINTENANCE REMOVED AND REPLACED BALLAST FOR NMay 11, 1996 · N269AU · Boeing 7372B7SDR TWRA9627Oven · failedDURING CRUISE, CABIN ATTENDANT REPORTED ELECTRICAL SMOKE COMING FROM UPPER DECK OVEN 704 CONTROLLER. PULLED CIRCUIT BREAKER AND REMOVED OVEN. ITEM WAS DEFERRED TO PAD 3822002, MEL 25-21. OVEN REPLACED. (M)May 9, 1996 · N602FF · Boeing 747124SDR CA960723516Electrical Panel · loose screws(CAN) ON ARRIVAL, GALLEY EQUIPMENT TURNED OFF DUE TO ELECTRICAL BURNING SMELL. MAINTENANCE CHECKED FOUND 3 LOOSE SCREWS BEHIND ELECTRICAL CONTROL PANEL. SCREWS TIGHTENED AND GALLEY ELECTRICAL POWER TESTED.May 5, 1996 · Doug DC932SDR DL73S961074Oven · failedAIRCRAFT RETURNED WITH LOG BOOK IRREG STRONG ODOR BEHIND PILOT SEATS BETWEEN C/B PANEL. THEN SMOKE FROM FORWARD GALLEY VENT AND OVENS. CORRECTIVE ACTION: FOUND FIRST CLASS OVEN FAN MOTOR BAD. REPLACED OVEN.May 4, 1996 · N326DL · Boeing 737232SDR DLL10961000Oven · smokingSMOKE COMING FROM NR 6 OVEN. F/A USED FIRE EXTINGUISHER TO CONTROL SMOKE COMING FROM SMOLDERING FOOD IN OVEN.Apr 25, 1996 · N716DA · Lkheed 10113851SDR CA960502055Heat Tank · overpressurized(CAN)COFFEE MAKER BOILED OVER. CAUSED STEAM IN GALLEY AND FLIGHT DECK AIRCRAFT RETURNED TO LAND. HEATER TANK FOUND OVERPRESSURIZED CAUSING TANK TO CONTACT GALLEY SHELF MELTING CONTACT AREA.Apr 22, 1996 · Dhav DHC8102SDR 96ZZZM907Ovens · smokingMIA - FLT 492 - WHILE AT THE GATE, OVENS BY L-1 DOOR EMITTED BURING SMELL AND SMOKE. OVENS WERE SHUT DOWN AND CIRCUIT BREAKER PULLED. BURNED PAPER AND FOOD WAS REMOVED FROM OVENS. OVENS WERE OPERATED AT THEIR HIGHEST TEMPERATURE SETTING FOR 30 MINUTES AND NApr 15, 1996 · N996Z · Doug DC932SDR 96UAL900249Buffet Module · inoperativeELECTRICAL ODOR THROUGHOUT AIRCRAFT. UPDATE AFT GALLEY BUFFET MODULE HAD AN ELECTRICAL FAULT. POWER REMOVED FROM MODULE AND UNIT REPLACED.Apr 10, 1996 · N7276U · Boeing 727222SDR CA960417516Oven Receptacle · elect. short(CAN)WHEN FRIDGE DOOR SLAMMED DURING DESCENT, A LARGE ELECTRICAL ARC JUMPED FROM TROLLEY, STOWED IN AISLE AND HIT THE FLOOR CLOSE TO THE LAVATORY DOOR. PASSENGERS AND CREW VERIFIED THE OCCURRENCE. MAINTENA NCE CHECK FOUND GALLEY OVER #18 RECEPTACLE DAMAGED. REApr 1, 1996 · Doug DC932SDR COMA9630095Warming Pot · defectiveBURNING ODOR NOTICED AT GALLEY AREA. REPLACED COFFEE WARMING POT.Mar 31, 1996 · N320CA · Saab SF340ASDR CAL960439Connector · failedIAH - FLT 1809 - WHITE SMOKE WITH BURNING ELECTRICAL SMELL ENTERED THE COCKPIT ON APPROACH TO IAH. THE SMOKE AND SMELL DISSIPATED AFTER TURNING OFF THE GALLEY POWER AND PULLING ALL CIRCUIT BREAKERS IN GALLEY. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCMar 30, 1996 · N19504 · Doug DC932SDR 96ZZZM767Oven · smokingONT - DURING CRUISE SMOKE WAS OBSERVED INSIDE REAR GALLEY OVEN. OVEN WAS OPENED AND A SMOKING PIECE OF PAPER/NAPKIN WAS REMOVED FROM THE OVEN. MAINTENANCE CLEANED AND CHECKED OVEN FOR PROPER OPERATION. (M)Mar 29, 1996 · N54354 · Boeing 727231SDR CKSA96030Oven · smokingVIDP - LEFT NR 2 OVEN (FACING FORWARD) AND LEFT NR 2 OVEN FACING AFT IN AFT GALLEY, BOTH EMITTED A LOUD RATTLING NOISE, GOT EXTREMELY HOT AND EMITTED SMOKE WITH NOTHING HAVING BEEN PUT IN OVEN. LUBED NR 2 OVEN FACING FORWARD AND LUBED NR 2 OVEN FACING AFT IN Mar 27, 1996 · N704CK · Boeing 747146SDR CA960417513Oven Receptacle · elect short(CAN)FLIGHT ATTENDANT RECEIVED ELECTRICAL SHOCK OFF GALLEY OVEN AND WAS FOLLOWED BY A BURNING SMELL. MAINTENANCE FOUND PINS ON OVEN BURNT AND OVEN RECEPTACLE DAMAGED. NEW OVEN INSTALLED AND RECEPTACLE CHAN GED.Mar 27, 1996 · Doug DC932SDR DL757960663Oven · failedHOT ELECTRICAL SMELL IN MID GALLEY, SEEMS TO BE COMING FROM AFT FACING OVENS. PULLED C/BS NO SUBSEQUENT PROBLEMS. REPLACED MID GALLEY AFT FACING DOUBLE OVEN OPS OK. ALSO, INSPECTED ELECTRICAL CABLES TO OVEN, ALL OK.Mar 26, 1996 · N643DL · Boeing 757232SDR DL767960638Coffee Maker · failedSMOKE AND HOT SMELL IN AFT GALLEY. HOT WATER COMING OUT OF COLD WATER FAUCET UNDER LT SIDE COFFEE MAKERS. FOUND NR 3 COFFEE MAKER OVERHEATING. PULLED AND COLLARED C/B. FWD TO MCO AND PLAC. REPLACED COFFEE MAKER, OPERATION NORMAL.Mar 22, 1996 · N101DA · Boeing 767232SDR CA960401007Connecting Plug · burnt(CAN)OVEN AT L3 CART #2 MADE SPARKS AT THE CONNECTOR PLUG. REPLACED.Mar 21, 1996 · Lkheed 1011385115SDR CA960417503Receptacle · elect short(CAN)GALLEY OVEN CIRCUIT BREAKER TRIPPING, GALLEY OVEN SMOKING. MAINTENANCE CHANGED OVEN RECEPTACLE.Mar 12, 1996 · Doug DC932SDR MWEA96056Oven · dirtyCREW REPORTS A/C RT OVEN PUTS OUT FOUL ODOR. DEFERRED OVEN UNTIL RETURN TO MKE. MAINTENANCE IN MKE CLEANED OVEN. NO FURTHER ODOR.Mar 7, 1996 · N401ME · Doug DC932SDR 96UAL900159Ovens · dirtyPOSSIBLE SMOKE IN GALLEY ON PUSH BACK, RETURNED TO BLOCKS. OVEN VENT SCREENS WERE PLUGGED WITH DIRT AND GRIM. CLEANED OVEN SCREENS.Mar 4, 1996 · N1811U · Doug DC1010SDR 96ZZZX1199Serving Cart · failedJFK - FLT 148 - DURING CRUISE, SERVING CART, SN 1482, EMITTED AN ELECTRICAL ODOR. DISCONNECTED SERVING CART. FOUND BAD HEATING PADS. REPLACED SERVING CART, MFG PN 958000-119. NEW SERVING CART OPERATION CHECKED NORMAL. CHECK C-11A - 11-29-95 - LAX.Feb 24, 1996 · N31023 · Lkheed 10113851SDR DL72S960364Oven · failedALL 3 FWD FACING OVENS IN AFT GALLEY WERE SMOKING AND EMITTING AN ELECTRICAL/CHEMICAL ODOR. THEY WERE NOT USEABLE.Feb 18, 1996 · N522DA · Boeing 727232SDR 9604095532Oven · dirtyDURING CLIMB WHILE PREPARING MEALS, FLIGHT ATTENDANT REPORTED SMOKE COMING FROM AFT GALLEY LT OVEN. FIRE BOTTLE WAS USED TO EXTINGUISH SMOKE. DECLARED AN EMERGENCY, RETURNED TO DTW, LANDING WAS UNEVENTFUL. UPON AIRCRAFT COMING TO A STOP ON TAXIWAY, CREW INIFeb 18, 1996 · N532US · Boeing 757251SDR 96UAL900105Switch · shortedGALLEY HOT PLATE NR H41 WAS SMOKING, SPARKING AND GAVE A FLIGHT ATTENDANT A SHOCK. CHECKED WIRING UNDER HOT PLATE ELEMENTS BEHIND CONTROL SWITCH AND NO OVERHEATING EVIDENT. REPLACED SWITCH AND HOTPLATE OPERATION CHECKS NORMAL.Feb 12, 1996 · N7293U · Boeing 727222SDR DLM88960314Oven · smokingFIRST CLASS GALLEY OVEN SMOKES, NO EVIDENCE OF FOOD SPILLAGE REPORTED. INSPECTED F/C OVEN, OPN NORMAL.Feb 10, 1996 · N900DE · Doug MD88SDR 96ZZZM664Coffee Maker · overheatedON FLT NR 444 - ATL-ATL - AIR RETURN, STRONG ACRID ODOR IN COCKPIT IN CLIMB-OUT SIMILAR TO ELECTRICAL SMOKE. INSPECTED ELECTRICAL SYSTEM IN AND AROUND FLIGHT DECK AREA AND GALLEY. RAN BOTH ENGINES, FOUND AN OVERHEATED COFFEE MAKER HOT PLATE. REMOVED AND REPFeb 6, 1996 · N966VV · Doug DC932SDR CA960320536Elect Receptacle · shorted(CAN)HOT CUPS AT REAR GALLEY POSITION 527 AND 528 SPARKED AND POPPED CIRCUIT BREAKER. SHORTED RECEPTACLES REPLACED.Jan 31, 1996 · Airbus A320211SDR 96ZZZX1226Serving Cart · smokingJFK - FLT 903 - DURING CRUISE, NR 2 AFT GALLEY SERVING CART EMITTED SMOKE WHEN TURNED ON. REMOVED AND REPLACED SERVING CART. OPERATIONAL CHECK NORMAL. CHECK C-6A - 12-7-95 - LAX.Jan 25, 1996 · N607TW · Boeing 767231SDR 96ZZZM207Serving Cart · smokingJFK - DURING CRUISE, NR 2 AFT GALLEY SERVING CART EMITTED SMOKE WHEN TURNED ON. REMOVED AND REPLACED SERVING CART. OPERATIONAL CHECK NORMAL. (M)Jan 25, 1996 · N607TW · Boeing 767231SDR MWEA96018Oven · malfunctionedCREW REPORTS, CIRCUIT BREAKER FOR LEFT OVEN POPPED. RESET CB, POPPED AGAIN. F/A REPORTS, SMELLING ELECTRICAL SMOKE. REPLACED OVEN AND OPS CHECK GOOD.Jan 19, 1996 · N203ME · Doug DC932SDR AU960076Wire · shorted(AUS) NR 2 GALLEY CONTROL PANEL PLUG PO 6 WIRING SHORT CIRCUITED ACROSS CORNER OF REAR CONTROL PANEL.Jan 16, 1996 · Fokker F28MK1000SDR ASAA9610009Coffee Maker · smokingANC - FLT NR 23 - CREW REPORTED, AFT GALLEY COFFEE MAKER STARTED SMOKING. TURNED OFF GALLEY POWER AND SMOKE SUBSIDED. REPLACED AFT GALLEY COFFEE MAKER AND OPERATED NORMALLY, NO ODORS DETECTED. (M)Jan 15, 1996 · N730AS · Boeing 737290CSDR DL757960085Coffee Maker · smokingELECTRICAL SMOKE CAME OUT OF NR 1 F/C COFFEE MAKER. C/B PULLED TO STOP SMOKE. REPLACED DISPENSER, OPN NML.Jan 14, 1996 · N674DL · Boeing 757232SDR CA960122022Fan · seized(CAN)DURING FLIGHT, SMOKE CAME FROM AROUND OUTER WALL OF OVEN. CIRCUIT BREAKER PULLED, EXTINGUISHER USED, PRECAUTIONARY LANDING, OVEN FAN HAD BURNT AND SEIZED. NO OTHER DAMAGE.Jan 13, 1996 · Boeing 75723ASDR TWRA9602Coffee Maker · failedJFK/LAX - DURING FLIGHT, MID-GALLEY COFFEE MAKER TRIPPED CIRCUIT BREAKER. WHEN CIRCUIT BREAKER WAS RESET, A STRONG ODOR OF ELECTRICAL SMOKE WAS NOTICED FOLLOWED BY VISUAL SMOKE. THE GALLEY WAS ISOLATED BY SHUTTING OFF GALLEY POWER. THE GALLEY WAS PLACARDED,Jan 10, 1996 · N604FF · Boeing 747121SDR ASAA9640002Oven · defectiveANC - FLT 197 - CREW REPORTED, AN ELECTRICAL SMELLING SMOKE WAS EMITTING FROM GRILL LABLELED 'CIRCUIT BREAKER BEHIND' ON AFT NR 2 RIGHT GALLEY OVEN. PULLED CIRCUIT BREAKER AND SMOKE SUBSIDED. RELEASED PER MEL 25-10 AND SUBSEQUENTLY REPLACED OVEN, OPERATED NOJan 10, 1996 · N783AS · Boeing 7374Q8SDR 9600219923Oven · smokingDURING FLIGHT, SMOKE ACCUMULATED IN AIRCRAFT FROM NR 2 OVEN. PILOTS WORE SMOKE GOGGLES AND OXYGEN MASKS UNTIL OVEN COOLED OFF. THE AIRCRAFT CONTINUED TO MSP AND LANDED WITHOUT INCIDENT. REPLACED THE OVEN AND OPERATIONAL CHECK GOOD.Jan 8, 1996 · N927RC · Doug DC932SDR 9600099923Oven · dirtyDURING APPROACH, SMOKE ACCUMULATED IN COCKPIT. DECLARED EMERGENCY WITH ATC AND AIRCRAFT LANDED WITHOUT FURTHER INCIDENT. FIRE DEPARTMENT MET FLIGHT AND VERIFIED SMOKE CAME FROM OVEN. CLEANED, OPERATIONALLY CHECKED OVEN AND OPERATIONAL CHECK GOOD. AIRCRAFT Jan 1, 1996 · N927RC · Doug DC932SDR 9521969304Coffee Maker · malfunctionedEN ROUTE MSP-ATL, SMOKE BEGAN EMANATING FROM THE COFFEE MAKER AREA. GALLEY POWER WAS EXTINGUISHED AND SMOKE DISSIPATED SHORTLY THEREAFTER. FLIGHT CONTINUED TO DESTINATION AND LANDED WITHOUT INCIDENT. FOUND RIGHT COFFEE MAKER WATER TANK HEATER MELTED. REPLADec 30, 1995 · N931MC · Doug DC982SDR AALA952138Oven · defectiveLHR - FLT 0116 - EN ROUTE JFK/LHR DURING CRUISE, ELECTRICAL SMOKE ODOR NOTED EITHER FROM OVENS 1 OR 2 IN FIRST CLASS GALLEY. PULLED CIRCUIT BREAKERS TO OVENS 1 AND 2 AND AIRCRAFT PROCEEDED TO LHR LANDING WITHOUT INCIDENT. CLEANED NR 2 OVEN IN FIRST CLASS GALDec 27, 1995 · N325AA · Boeing 767223SDR AALA952112Oven · dirtyLHR - FLT 156 - DURING CRUISE, THE NR 6 OVEN STARTED TO EMIT SMOKE WHEN IT WAS TURNED ON. TURNED OVEN OFF AND SMOKE DISSIPATED. LANDED WITHOUT INCIDENT. CLEANED DEBRIS FROM BOTTOM OF OVEN, SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Dec 19, 1995 · N329AA · Boeing 767223SDR CA960110506Oven · elect fault(CAN)AISLE TROLLEY (MEAL) POPPED CIRCUIT BREAKER & GAVE AN ELECTRICAL SHOCK TO FLIGHT ATTENDANT. MAINTENANCE ACTION INVOLVED CHECKING THREE PHASE POWER & GROUND RETURN, AIRCRAFT OVEN OUTLET. OVEN REPLACED.Dec 10, 1995 · Doug DC932SDR 96ZZZX646Coffeemaker · failedCID - FLT 64 - DURING CRUISE, FIRST CLASS COFFEEMAKER EMITTED SMOKE. TURNED OFF COFFEEMAKER AND OPENED CIRCUIT BREAKER. FOUND INTERNAL MALFUNCTION IN COFFEEMAKER. REPLACED COFFEEMAKER, MFG PN 50198A, AND OPERATION CHECKED NORMAL. CHECK C - 2-17-95 - MCI.Dec 10, 1995 · N490SA · Doug DC915SDR 95UAL900294Circuit Breaker · failedSMOKE, SPARKS AND FLAMES SEEN FROM COFFEE MAKER AT GALLEY 411. EXTINGUISHER USED AND CIRCUIT BREAKERS WERE PULLED. REPLACED FAILED CIRCUIT BREAKER AND ENTREE CART POWER CORD. CAUSE OF FAILURE NOT DETERMINED. POSSIBLE CAUSE: OVERCYCLING OF CIRCUIT BREAKER Dec 6, 1995 · N4729U · Boeing 747122SDR DL767954607Oven · overheatedUPPER RT SIDE AFT GALLEY OVEN OVERHEATED AND BEGAN TO SMOKE. FOUND THERMOSTAT FAULTY. SET UP FOR OVEN REPLACEDMENT AND FWD TO MCO.Dec 2, 1995 · N111DN · Boeing 767232SDR AALA951989Coffee Maker · defectiveLHR - FLT NR 86 - EN ROUTE ORD/LHR DURING CRUISE, SPARKS NOTED COMING FROM TOP OF NR 4 COFFEE MAKER IN B-C GALLEY. AIRCRAFT PROCEEDED LHR AND LANDED WITHOUT INCIDENT. REPLACED NR 4 COFFEE MAKER IN B-C GALLEY. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)Nov 30, 1995 · N1764B · Doug MD11SDR DL733954594Oven · smokingSMOKE OBSERVED COMING FROM FWD GALLEY INBD OVEN. TURNED OFF AND SMOKE CLEARED. PUT ON MCO C/N 549351002 BY SLC. ITEM CLEARED BY REPLACEMENT OF OVEN.Nov 29, 1995 · N313WA · Boeing 737347SDR HALA95160Connector · shortedHNL - FLT NR 506 - FLIGHT ATTENDANT REPORTED SMOKE (ELECTRICAL SMELL) FROM COFFEE MAKER. FOUND NR 2 COFFEE MAKER CANNON PLUG FROM AIRCRAFT SOURCE SHORTED. REPLACED NR 2 COFFEE MAKER. REPAIRED CANNON PLUGS. OPERATIONAL AND LEAK CHECK GOOD. (M)Nov 23, 1995 · N709HA · Doug DC951SDR CA960103519Receptacle · burnt(CAN)PRIOR TO DEPARTURE, BURNING SMELL DETECTED IN GALLEY AREA. CHECK OF AREA FOUND #18 OVEN RECEPTACLE BURNT. RECEPTACLE REPLACED.Nov 15, 1995 · Doug DC932SDR DLL14954381Oven · dirtyNR 6 OVEN LOWER GALLEY GREASE FIRE. C/B PULLED, HALON DISCHARGED. VENT APPEARS CLOGGED WITH FOIL. CLEANED NR 6 OVEN, OK FOR SERVICE.Nov 14, 1995 · N1739D · Lkheed 1011385115
Back to JASC 2530