Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2530' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR WWMA9500082Hot Container · defectiveTHE FLIGHT CREW REPORTED, THAT THE NR 2 HOT WATER CONTAINER SMELLS LIKE BURNING PLASTIC WHEN HEATED. ALSO, THAT THE ODOR ORIGINATED FROM THE PLUG IN CONNECTION ON THE BACK OF THE CONTAINER. MAINTENANCE INSPECTED THE AIRFRAME HOT WATER CONTAINER SOCKET, NO DISDR WWMA9500076Connector · contaminatedTHE FLIGHT ATTENDANT REPORTED SMELLING AN ELECTRICAL BURNING SMELL AT THE NR 2 HOT JUG. UPON INVESTIGATION, MAINTENANCE FOUND THE EXTERIOR OF THE WATER JUG SOAKED WITH WATER AND WATER IN THE ELECTRICAL CONNECTION. THE JUG AND THE ELECTRICAL CONNECTION WERE DSDR 97ZZZM85Oven · malfunctionedPDX - DURING CRUISE 'D' GALLEY OVEN, MFG P/N 8203-11-0000 EMITTED SMOKE. OVEN WAS TURNED OFF AND CIRCUIT BREAKER PULLED. TROUBLESHOOTING UNDERWAY TO DETERMINE CAUSE. INVESTIGATION REVEALED OVEN HAD INTERNAL MALFUNTION AND WAS RETURNED TO THE MANUFACTURE. (SDR 95ZZZX6801Oven · smokingPDX - FLT 173 - DURING CRUISE, 'D' GALLEY OVEN, MFG P/N 8203-11-0000, EMITTED SMOKE. OVEN WAS TURNED OFF AND CIRCUIT BREAKER PULLED. TROUBLESHOOTING UNDERWAY TO DETERMINE CAUSE. OP-16 - 8-25-95 - MCI.SDR 95ZZZM675Oven · dirtyJFK - DURING CRUISE A STRONG NON-ELECTRICAL BURNING ODOR WAS DETECTED IN GALLEY 'A'. REMOVED AND REPLACED DIRTY OVEN, OPERATIONAL CHECK NORMAL.SDR 95UAL900216Oven · overtempFORWARD LOWER LOBE GALLEY FIRE WARNING AFTER TAKEOFF. SUSPECTED CAUSE IS EXCESSIVE TEMPERATURE SETTING FOR THE FOOD STUFFS/PACKAGING PLACED IN THE OVEN. CORRECTIVE ACTION HAS BEEN TO ISSUE AN ALERT BULLETIN FOR ALL MAINTENANCE PERSONNEL TO FOLLOW REVISED PROSDR DL76L954049Coffee Maker · failedAPPROX ONE HOUR BEFORE DESCENT, F/A IN AFT GALLEY REPORTED SEEING SMOKE AND SMELLING ELECTRICAL WIRE BURNING. UTILITY BUSSES SWITCHES OFF. REPLACED NR 2 COFFEE MAKER DUE TO C/B POPPED. INSPECTED OVENS AND GALLEY WIRING OPERATION NORMAL.SDR CA951129516Oven · burnt(CAN)PRIOR TO DEPARTURE SMOKE IN #3 GALLEY OVEN CAVITY. CHANGED #3 OVEN AND CONTROLLER.SDR 95UAL900190Circuit Breakers · hotAFTER PUSH-BACK ON ENGINE START, HAD A HOT ELECTRICAL SMELL FROM GALLEY AREA. SMELL CAME FROM AREA OF CIRCUIT BREAKERS ON FORWARD WALL OF AFT GALLEY. WALL WAS WARM PER FLIGHT ATTENDANT. ALL CIRCUIT BREAKERS PULLED AND COLLARED. OPENED CEILING PANELS, LOOKSDR TSAA9525180Coffee Jug · shortedFLT 30 - PIREP 1 - SMOKE IN GALLEY COMING FROM COFFEE/HOT JUG AT L1H. ISOLATED TROUBLE TO NR 6 COFFEE JUG, JUG REMOVED. CIRCUIT BREAKER PULLED AND SWITCHED TO OFF FOR NR 6 COFFEE JUG RECEPTACLE. AIRCRAFT AND LOG BOOK PLACARDED PER MEL 25-10. HNL - REPLACEDSDR CA951129503Receptacle · burnt(CAN)A BURNING ELECTRICAL SMELL WAS DETECTED IN THE GALLEY AREA. INVESTIGATION REVEALED #1 OVEN RECEPTACLE WAS BURNT. DEFECTIVE ELECTRICAL RECEPTACLE REPLACED.SDR CAL950866Coffeemaker · leakingEWR - FLT 0341 - CREW REPORTED SMOKE COMING FROM THE AFT GALLEY WHILE ON APPROACH TO EWR. THE GALLEY CIRCUIT BREAKERS WERE PULLED AND THE SMOKE DISAPPEARED. THE AIRCRAFT LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED THE AFT GALLEY AND FOUND THE UPPER AFT CSDR 95ZZZM627Serving Cart · failedSFO - DURING CRUISE SERVING CART EMITTED SMOKE AND ELECTRICAL ODOR. DISCONNECTED SERVING CART. FOUND DEFECTIVE POWER CORD ON SERVING CART. REPLACED SERVING CART, MFG P/N 611-710345-1. OPERATION CHECKED NORMAL. (M)SDR C2XA95CL117Hot Jug · shortedFLT NR 3400 - EWR - FLIGHT CREW REPORTED BURNING ELECTRICAL SMELL IN GALLEY AREA. AIRCRAFT RETURNED TO EWR. MAINTENANCE INSPECTED AND REMOVED FAULTY HOT JUG FROM AIRCRAFT. PLACED SYSTEM ON MEL. AIRCRAFT RETURNED TO SERVICE. (M)SDR SCNA95196Coffee Maker · failedCOFFEE MAKER BEGAN SMOKING IN GALLEY. THE CIRCUIT BREAKER WAS PULLED FOR THE COFFEE MAKER AND THE SMOKE CEASED. REMOVED AND REPLACED COFFEE MAKER AND NEW UNIT TESTED GOOD.SDR CAL950847Coffeemaker · inoperativeORD - FLT 1616 - THE AFT NR 2 COFFEEMAKER BEGAN TO SMOKE IN-FLIGHT. THE SMOKE CEASED AFTER PULLING THE CIRCUIT BREAKER AND USING THE FIRE EXTINGUISHER. THE NR 2 AFT COFFEEMAKER WAS REMOVED AND REPLACED AND OPERATION CHECKED GOOD. THERE WERE NO OTHER DISCREPSDR ASAA9510086Oven · defectiveANC - ON ARRIVAL OF FLIGHT 58, CREW REPORTED A STRONG ELECTRICAL ODOR EMINATED FROM OVEN IN FORWARD GALLEY WHILE IN USE. ODOR DISSIPATED WHEN GALLEY POWER TURNED OFF. REMOVED AND REPLACED DOUBLE OVEN IN NR 1 GALLEY AND OPERATED NORMALLY WITH NO ODORS NOTED. SDR CAL950792Oven · dirtyFLT NR 0050 - FRA - THE FORWARD GALLEY OVEN NEXT TO LEFT AISLE BEGAN PRODUCING SMOKE IN FLIGHT. THE SMOKE CEASED SHORTLY AFTER OVEN POWER WAS REMOVED. THE FLIGHT WAS CONTINUED WITHOUT FURTHER PROBLEM. MAINTENANCE FOUND FOOD CONTAMINATING THE HEATING ELEMENTSDR 95ZZZM528Serving Cart · failedJFK - DURING CRUISE AFT GALLEY SERVING CART NR 4, EMITTED SMOKE AND ELECTRICAL ODOR. TURNED OFF AND DISCONNECTED CART, MFG P/N 88801-1. FOUND MALFUNCTIONING HEATING PLATES. REPLACED SERVING CART AND OPERATION CHECKED NORMAL.SDR 95ZZZM527Controller · failedJFK - DURING CRUISE SMOKE AND ELECTRICAL ODOR EMITTED FROM AFT GALLEY E-1 SERVING CART CONTROLLER, MFG P/N B00678-1. TURNED OFF CONTROLLER AND OPENED CIRCUIT BREAKERS. REPLACED THE E-1 CART CONTROLLER AND OPERATION CHECKED NORMAL.SDR 95ZZZM449Serving Cart · smokingJFK - FLT NR 740 - DURING CRUISE AFT GALLEY SERVING CART NR 4, EMITTED SMOKE AND ELECTRICAL ODOR. TURNED OFF AND DISCONNECTED CART, MFG P/N 88801-1. FOUND MALFUNCTIONING HEATING PLATES. REPLACED SERVING CART AND OPERATION CHECKED NORMAL.SDR 95ZZZM446Controller · smokingJFK - FLT NR 803 - DURING CRUISE, SMOKE AND ELECTRICAL ODOR EMITTED FROM AFT GALLEY E-1 SERVING CART CONTROLLER, MFG P/N B006781. TURNED OFF CONTROLLER AND OPENED CIRCUIT BREAKERS. REPLACED THE E-1 CART CONTROLLER AND OPERATION CHECKED NORMAL.SDR DLL10953491Wire · burnedNR 2 OVEN 'B' PHASE FEEDER WIRES AND TERMINAL BLOCK BURNED. RETERMINATED WIRES AND REPLACED OVEN. FLT ATTENDANT REPORTED OVEN OVERHEATING.SDR DL76S953386Galley · odorDURING CRUISE, FLIGHT ATTENDANT REPORTED INTERMITTENT BURNING ODOR JUST FWD OF MID GALLEY ON RT SIDE. ODOR AND FREQUENCY WORSENED, DEACTIVATED POWER IN MID GALLEY, SMELL DISSIPATED. CEILING PANELS WERE LOWERED, AREA INSPECTED AND GALLEY EQUIPMENT TURNED ON. SDR QXEA9500242Coffee Jug Latch · loosePDX - LATCH ON COFFEE JUG FALLS DOWN ON ROTATION. COFFEE JUG FELL OUT AND STRUCK PASSENGER. SAFETY CATCH WAS REPLACED AND A ADDITIONAL CATCH WAS INSTALLED. AIRCRAFT RETURNED TO SERVICE.SDR DL72W953353Coffee Maker · odorCOFFEE MAKER AND AFT FACING OVEN IN AFT GALLEY GIVING OFF INTENSE ODOR, HOT PLASTIC SMELL. SHUT OFF COFFEE MAKER AND OVEN, GOT RID OF ODOR. REMOVED PLASTIC BAGS FROM UNDER COFFEE MAKER AND FROM SIDE OF OVEN FOOD RACK. COFFEE MAKER AND OVEN OPN NORMAL WITH NSDR CAL950619Coffeemaker · smokingFLT NR 0538 - EWR - SMOKE WAS OBSERVED COMING FROM THE VICINITY OF THE AFT GALLEY COFFEEMAKER WHILE IN FLIGHT. THE COFFEEMAKER WAS TURNED OFF AND THE SMOKE CEASED. MAINTENANCE FOUND BURNT PAPER AT THE BACK OF THE COFFEEMAKER. THE AREA WAS CLEANED FREE OF THSDR AALA951336Cart · defectiveLHR - FLT NR 0116 - AFTER TAKEOFF AN ACRID ODOR WAS REPORTED IN THE MID GALLEY AREA ACCOMPANIED BY A TRACE OF SMOKE. SECURED GALLEY POWER AND ODOR DISSIPATED ALONG WITH SMOKE. LANDED LHR WITHOUT INCIDENT. REPLACED WARMING CART, NO ODOR OR SMOKE. SYSTEM GROSDR 95ZZZM292Oven · smokingPHX - DURING CRUISE, AFT GALLEY FORWARD OVEN EMITTED SMOKE. SHUT OFF OVEN, SMOKE DISSIPATED. FOUND CHARRED PAPER FROM FOOD CONTAINER. CLEANED OVEN AND OPERATION CHECK NORMAL.SDR CAL950609Oven · inoperativeFLT NR 0762 - EWR - AN OVEN IN FIRST CLASS GALLEY BEGAN TO SMOKE WHILE IN FLIGHT. THE SMOKE WAS ACCOMPANIED BY A CRACKING SOUND AND THE POWER LIGHT FLICKERING. THE SMOKE CEASED AFTER PULLING THE OVEN CIRCUIT BREAKER AND SHUTTING OFF THE GALLEY POWER. THE FLSDR DL757953133Coffee Maker · smokingDURING CRUISE, F/A REPORTED SMOKE COMING OUT OF FORWARD GALLEY COFFEE MAKER. POWER WAS REMOVED AND AS PRECAUTION PORTABLE FIRE EXTINGUISHER WAS USED. COFFEE MAKER WAS REPLACED, OPERATION NORMAL.SDR 95ZZZX4173Coffee Maker · overheatingATL - FLT 166 - SMOKE IN COCKPIT ON APPROACH TO ATL. FOUND TO BE FORWARD GALLEY COFFEE MAKER OVERHEATING. REMOVED COFFEE MAKER AND PLACED ON MEL.SDR 95ZZZM298Food Cart · failedDURING CRUISE, FOOD CART S/N 3212, HAD ELECTRICAL MALFUNCTION AND EMITTED STRONG FUMES. DISCONNECTED FOOD CART. REPLACED FOOD CART, MFG P/N 88801-1, CHECKED GALLEY ELECTRICAL, AND OPERATION WAS NORMAL.SDR DLM11953084Coffee Maker · smokingDURING CRUISE, BUSINESS CLASS GALLEY AFT COFFEE MAKER BEGAN TO SMOKE AND POP, THEN WATER STARTED TO LEAK. SHUT OFF POWER AND WATER TO MAKER. DISPENSER WAS INITIALY DEFERRED, THEN REPLACED AT PDX.SDR DL73E953057Trash Bin · odorON DESCENT, FLT ATTENDANTS REPORTED FUMES IN AFT GALLEY, SMELLED LIKE JET FUEL. EMERGENCY WAS DECLARED, LANDED IN STL WITHOUT INCIDENT. INSPECTION FOUND FUMES TO BE FROM GALLEY TRASH BIN AND CLEANING FLUID RESIDUE. REMOVED TRASH, RETURNED TO SERVICE.SDR CAL950554Oven · dirtyEWR - FLT 0041 - THE FORWARD GALLEY CENTER OVEN EMITTED SMOKE MOMENTARILY WHILE AT CRUISE. MAINTENANCE FOUND HEATING ELEMENTS AND BOTTOM OF OVEN CONTAMINATED WITH GREASE AND OIL. THE OVEN WAS CLEANED. OVEN OPERATION CHECKED GOOD WITH NO SMOKE PRODUCED AND NSDR ASAA9580159Coffee Maker · malfunctionedANC - FLT 107 - FLIGHT ATTENDANT REPORTED ELECTRICAL SMOKE ODOR IN GALLEY NR 3 DURING CRUISE. DEACTIVATED GALLEY POWER AND ODOR DISSIPATED. OPERATED ALL AFT GALLEY APPLIANCES AND UNABLE TO DUPLICATE ODOR. REPLACED NR 3 GALLEY COFFEE MAKER AND NO EVIDENCE OFSDR SCNA95139Oven · faultyAFT OVEN SWITCHED OFF WHILE COOKING MEALS, AFTER REMOVING MEALS, OVEN BEGAN TO SMOKE AND SMELL BURNED. REMOVED AND REPLACED OVEN AND UNIT CHECKED GOOD.SDR DLL15953270Chiller Unit · failedDURING CRUISE, HAD SMOKE ODOR IN F/C GALLEY WITH C/B FOR CHILLER POPPED. CHILLER WAS REPLACED, OPERATION NORMAL.SDR SCNA95132Oven · smokingDURING CLIMB FROM LAS, AFT OVEN STARTED SMOKING. FLIGHT ATTENDANT TURNED OFF OVEN AND SMOKE STOPPED. DURING INSPECTION OF OVEN, FOUND NO EVIDENCE OF FIRE. FOUND CLEANING SOLVENT ON OUTBOARD OVEN HEATING COILS. CLEANED COILS AND TESTED OVENS PER MM 25-20-00SDR TSAA9525124Hot Jug · shortedFLTN RN 220 - DC CONTROL CIRCUIT BREAKER RESET, AND SMOKE BEGAN TO COME OUT OF UPPER GALLEY AREA. DC CONTROL CIRCUIT BREAKER PULLED AND SMOKE STOPPED. REPLACED CONNECTOR PLUG FOR HOT JUG DUE TO SHORTED. OPERATIONAL CHECK OK. AIRCRAFT RETURNED TO SERVICE. SDR AALA951007Cart · defectiveBHX - FLT NR 0024 - BUSINESS CLASS GALLEY WARMING CARTS OVERHEATS SEVERELY WITH ELECTRICAL SMELL. REPLACED BUSINESS CLASS GALLEY WARMING CART. SYSTEM GROUND CHECKED NORMAL OPERATION. (M)SDR CAL950428Ovens · failedSFO - FLT 0151 - THE GALLEY POWER NR 2 PHASE 'A' 50 AMP CIRCUIT BREAKER ON AFT COCKPIT BULKHEAD TRIPPED DURING FLIGHT AND WAS ACCOMPANIED BY THE COPILOT'S INSTRUMENTS SHOWING FLAGS MOMENTARILY. THE FLIGHT ATTENDANT ALSO REPORTED SPARKS COMING FROM BEHIND OVENSDR 95ZZZW751Oven · failedSTL - DURING CRUISE E GALLEY OVEN, MFG P/N 50381, BEGAN SMOKING WHEN TURNED ON. TURNED OFF OVEN. REPLACED OVEN AND OPERATION CHECKED NORMAL.SDR DL76P951837Coffee Maker · failedDURING CRUISE, FORWARD GALLEY COFFEE MAKER STARTED TO POP AND EMIT SMOKE AND ELECTRICAL BURNING ODOR. SHUTOFF POWER, ODOR QUICKLY STOPPED. FOUND BURNED WIRES ON NR 2 COFFEE MAKER. REPLACED UNIT, OPERATION NORMAL.SDR DL72W952126Oven · smokingDURING CRUISE, FLT ATTENDANT REPORTED FWD GALLEY OVEN EMITTED SMOKE AS SOON AS IT WAS TURNED ON. OVEN WAS INSPECTED, PROBLEM COULD NOT BE DUPLICATED, RETURNED TO SERVICE.SDR MWEA95181Oven · inopCREW REPORTS, 3 OVEN CIRCUIT BREAKER POPPED IN FLIGHT AND F/A SMELLED BURNING ODOR IN CABIN. MAINTENANCE REMOVED AND REPLACED OVEN. OPS CHECK GOOD, RETURNED AIRCRAFT TO SERVICE.SDR 9506502707Oven · dirtyDURING CLIMB, FLIGHT ATTENDANT REPORTED SMOKE FROM FIRST CLASS OVEN 2-7B. PULLED CIRCUIT BREAKERS AND SMOKE DISSIPATED. NO FLAMES WERE NOTICED. FLIGHT CONTINUED WITHOUT FURTHER INCIDENT. MAINTENANCE CLEANED DEBRIS AND GREASE FROM OVEN. OPERATIONAL CHECK NSDR DLL10951558Drain · pluggedDRAIN ON CAPTS SIDE IN MID GALLEY STOPPED UP AND WATER SEEPED INTO SERVICE OUTLET. OUTLET BEGAN TO SMOKE, SHUT OFF ALL GALLEY POWER AND PULLED C/B. CLEARED DRAIN LINE AND REPLACED OUTLET RECEPTACLE.SDR AALA950598Oven · dirtyLHR - FLT 108 - EN ROUTE BOS-LHR - DURING CRUISE, FIRST CLASS GALLEY OVEN EMITTED SMOKE FROM INSIDE OVEN COMPARTMENT DURING USE. NO OTHER ABNORMAL INDICATIONS. AIRCRAFT PROCEEDED LHR AND LANDED WITHOUT INCIDENT. CLEANED INTERIOR OF FIRST CLASS GALLEY OVEN.
Back to JASC 2530