Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA090480Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR UALA2009012200244Latch · wornRIGHT OVERWING SLIDE COMPARTMENT DOOR LATCH NR 2 WORN AND HARD TO OPERATE. REPLACED THE DOOR LATCH.SDR WRLA2009013Slide · inoperativeDURING C1 CHECK INSPECTION, TEST DEPLOYED L2 DOOR SLIDE, WHEN HANDLE WAS PULLED AND DOOR RAISED SLIDE DETACHED AND FELL STRAIGHT ONTO THE CABIN FLOOR AND DID NOT INFLATE. REF C1 TASK CARD 1095. REMOVED AND REPLACED L2 DOOR SLIDE/RAFT IAW WOA TASK CARD 1095.SDR SWAA090465Slide · out of positionDURING SCHEDULED 22Y CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR AALA2009012000003Bottle · defectiveDFW - RIGHT NUMBER ONE DOOR SLIDE CAME OUT OF HOUSING AND DID NOT INFLATE. REPLACED POWER ASSIST BOTTLE FOR RIGHT NUMBER ONE DOOR SLIDE.SDR AALA2009012000002Slide · defectiveMIA - GIRT BAR AT RIGHT NUMBER ONE DOOR DOES NOT SIT CORRECTLY AND SAFELY. REPLACED RIGHT NUMBER ONE DOOR SLIDE.SDR AALA2009012000001Slide · out of positionDFW - RIGHT NUMBER ONE DOOR SLIDE CAME OUT OF HOUSING AND DID NOT INFLATE. REPLACED SLIDE FOR RIGHT NUMBER ONE DOOR.SDR UALA2009012100226Latch · gougedRT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH GOUGED. REPLACED RT OVERWING SLIDE COMPARTMENT DOOR NR 2 LATCH.SDR UALA2009012100225Latch · damagedLEFT WING OVERWING SLIDE DOOR, NR 3 LATCH HAS GROOVE IN SLIDER. REPLACED LT OVERWING SLIDE DOOR NR 3 LATCH. OPS CHECKS GOOD.SDR SWAA090442Slide · out of positionDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA090403Slide · out of positionDURING SCHEDULED MV2 CHECK, FOUND R1 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR UALA2009012000223Container · delaminatedLT OVERWING SLIDE CONTAINER BOX IS DELAMINATED. REMOVED AND REPLACED LEFT OVERWING SLIDE.SDR 7A7B20091192Slide · unwanted deployUNCOMANDED DEPLOYMENT OF OFF WING EVACUATION SLIDE.SDR SWAA090415Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. ADJUSTED SLIDE PER MM.SDR SWAA090408Slide · out of positionR1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR UALA2009011900202Slide · unserviceableDOOR 4 RIGHT SLIDE NEEDS REPLACEMENT DUE TO SLIDE BECOMING UNPACKED. SLIDE ON SITE AND RESERVED. REPLACED SLIDE.SDR SWAA090394Slide · out of adjustR2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR CALA2009011900042Cable Assy · frayedR-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE HAS BROKEN STRANDS. REMOVED AND REPLACED R-2 DOOR SLIDE LATCH CABLE PER 25-61-35.SDR UALA2009031000179Fitting · faultyDOOR 2 LT ESCAPE SLIDE BUSTLE STRAP RETAINING CLIP BROKEN. REPLACED SLIDE ASSY.SDR SWAA090421Slide · out of positionR1 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA090414Slide · out of positionDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MM.SDR SWAA090410Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR CALA2009011900041Cable Assy · frayedL-2 DOOR EMERGENCY ESCAPE SLIDE LATCH CABLE HAS BROKEN STRANDS. REMOVED AND REPLACED L-2 DOOR SLIDE LATCH CABLE PER 25-61-35.SDR SWAA090360Slide · out of adjustDURING SCHEDULED CV CHECK, FOUND L1 DOOR EMERGENCY EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MT.SDR SWAA090355Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA090354Slide · out of positionL1 DOOR EMERGENCY EVACUATION SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MT.SDR SWAA090353Slide · looseL1 DOOR EMERGENCY EVACUATION SLIDE LOOSE. SECURED SLIDE PER MT.SDR SWAA090335Slide · out of adjustDURING SCHEDULED SPV CHECK, FOUND L1 EMERGENCY EVACUATION DOOR SLIDE OUT OF ADJUST. REMOVED AND REPLACED SLIDE PER MT.SDR USAASB09012Bottle · low pressureCLT MX REPORTED THE R1 DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE WAS LOW. MX R&R THE R1 DOOR EMERGENCY ESCAPE SLIDE PER JOB CARD 03T10025002.SDR UPS09M54500Slide · out of positionINSPECTION TYPE:C R1 DOOR - UNABLE TO STOW LWR DOOR LINING FLAP PNL DUE TO OBSTRUCTION BY DOOR SLIDE RAFT. R1 DOOR LWR LINING REMOVED PER AMM 25-23-07-400-802 REV 63. R1 DOOR SLIDE/RAFT REMOVED PER AMM 25-61-15-4 REV 63. R1 DOOR SLIDE/RAFT INSTALLED PER AMMSDR UPS09454498Slide · out of positionINSPECTION TYPE:C R1 DOOR - UNABLE TO STOW LWR DOOR LINING FLAP PNL DUE TO OBSTRUCTION BY DOOR SLIDE RAFT. R1 DOOR LWR LINING REMOVED PER AMM 25-23-07-400-802 REV 63. R1 DOOR SLIDE/RAFT REMOVED PER AMM 25-61-15-4 REV63. R1 DOOR SLIDE/RAFT INSTALLED PER AMM SDR UALA2009011400155Slide · out of positionUPON 1L DOOR OPENING SLIDE PACK DROPPED OUT, DID NOT DEPLOY. SLIDE INSPECTION PERFORMED IAW AMM 25-66-01-6, NO DAMAGE FOUND. INSTALLED SLIDE. ALL SYSTEMS CHECKED, OPS NORMAL. ALL WORK HAS BEEN PERFORMED.SDR SWAA090310Cable · brokenDURING SCHEDULED 24Y CHECK, FOUND R2 DOOR EMERGENCY EVACUATION SLIDE SHROUD CABLE BROKEN. REMOVED AND REPLACED CABLE PER SRM.SDR UALA2009011300147Slide · unserviceableDURING INTERIOR INSP, FOUND L1 DOOR SLIDE TO BE OUT OF LIMITS. REMOVED 1L SLIDE AND PINED PLACED IN SHOP. PUT ATTACHING HARDWARE BACK INTO ATTACHING HOLES IN ORDER NOT TO LOOSE THE BOLTS. GIRT BAR IS STILL ATTACHED TO SLIDE. INSTALLED LAST BOLT INTO THE SLIDESDR UALA2009011300150Disc · damagedLOW BOTTLE. DAMAGE TO BURST DISC CAUSING A SLOW LEAK. R&R BURST DISC.SDR UPS09M54496Slide · out of positionINSPECTION TYPE:C L1 DOOR - UNABLE TO STOW DOOR LWR LINING FLAP PNL DUE TO SLIDE RAFT OBSTRUCTION. L1 DOOR LWR LINING REMOVED PER AMM 25-23-07-400-802 REV 63. L1 DOOR SLIDE/RAFT REMOVED PER AMM 25-61-15-4 REV 63. L1 DOOR SLIDE/RAFT INSTALLED PER AMM 25-61-1SDR SWAA090230Slide · unwanted deployL1 EMERGENCY EXIT DOOR SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA090206Slide · out of positionDURING SCHEDULED SPV CHECK, FOUND R1 DOOR EMERGENCY EXIT SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR SWAA090196Cable · frayedDURING SCHEDULED 18Y CHECK, FOUND R2 DOOR EMERGENCY EXIT SLIDE CABLE FRAYED. REMOVED AND REPLACED CABLE PER MM.SDR CALA2009011300033Cable · frayedL-2 DOOR EMERGENCY ESCAPE SLIDE CABLE HAS BROKEN STRANDS. REMOVED AND REPLACED THE L-2 DOOR EMERGENCY ESCAPE SLIDE CABLE IAW AMM 25-61-35.SDR CALA2009011300032Cable · frayedR-2 DOOR EMERGENCY ESCAPE SLIDE CABLE HAS BROKEN STRANDS. REMOVED AND REPLACED R2 DOOR EMERGENCY ESCAPE SLIDE CABLE IAW AMM 25-61-35.SDR ZZDA2009012Slide · deployedESCAPE SLIDE DISLODGED AT FORWARD SERVICE DOOR (DEPLOYED). REMOVED AND REPLACED SERVICE DOOR SLIDE ASSEMBLY IAW AMM 25-66-01.SDR USAABB09004Slide · low pressureTHE L1 DOOR EMERGENCY ESCAPE SLIDE PRESSURE WAS FOUND OUT OF THE GREEN BAND. MX REPLACED THE L1 DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE.SDR SWAA090189Slide · out of positionR2 DOOR EMERGENCY EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE PER MT.SDR AALA2009010900001Slide · inoperativeDFW - CABLE PROTRUDING FROM BEHIND SLIDE PACK AT AFT GALLEY DOOR. REMOVED AND REPLACED SLIDE AT AFT GALLEY DOOR.SDR USAABB09018Light · inoperativePHL - THE SLIDE ARMED LIGHT ABOVE THE R1 DOOR WAS FOUND INOPERATIVE. MAINTENANCE REPLACED THE BULBS AS REQUIRED. OPERATIONALLY CHECKS GOOD.SDR UALA2009011200132Aspirator · leakingASPIRATOR LEAKING. MFG DEFECT. REPLACED BARREL.SDR UALA2009011200131Slide · low pressurePRESSURE LOW. UNKNOWN. GAUGE READS WITHIN LIMITS. NO ACTION TAKEN.SDR UALA2009011200130Gauge · leakingSLIDE PRESSURE LOW. LEAKING AROUND GAUGE FACE. REMOVED AND REPLACED GAUGE.SDR USAABB003Slide · defectiveTHE EVACUATION SLIDE ARMING LEVER WAS BINDING AT SERVICE DOOR 1R. MX REPLACED THE 1R DOOR EMERGENCY ESCAPE SLIDE. OK FOR SERVICE.
Back to JASC 2565