Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA072156Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR NOCA09507Slide · activatedL1 SLIDE INOP, FOUND L1 DOOR 1/4 OPENED. THE EVAC SLIDE HALF OUT OF CONTAINER CASE WITH THE GIRT BAR STILL ATTACHED TO THE DOOR FRAME. THE EVACUATION SLIDE HANDLE WAS IN THE ARMED POSITION AND THE DOOR ASSIST BOTTLE HAD FIRED. REMOVED AND REPLACED L-1 DOOR SDR UPS07M49726Cover · unsecureLEFT SLIDE PACK COVER (EMERG EGRESS NOT SEATED PROPERLY). RESECURED COVER.SDR ZZDA070430153Slide · unserviceableDURING RII INSPECTION THE PINS WERE FOUND PULLED. R&R L1 SLIDE ASSY( FOUND PIN PULLED ) IAW REF MM 25-61-01.SDR 2007UALA01331Slide · unsecureTHE 2L SLIDE OFF MOUNTING. [SUP 05-16-07] REINSTALLED SLIDE.SDR 2007UALA01330Slide · unknownSTRINGS HANGING OUT OF DOOR 2L ESCAPE SLIDE. [SUP 05-16-07] REPLACED SLIDE.SDR 2007UALA01319Cable · disengagedLT AFT MED SLIDE RELEASE CABLE DISENGAGED. [SUP 05-18-07] RE-ENGAGED SLIDE RELEASE CABLE PER MM 25-66-00. READY FOR SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT CABLE DISENGAGED BY CONTACT WITH CABIN SERVICE EQUIPMENT DURING LOADING/UNLOADING.SDR NWAA071623205Cable · brokenLEFT OVERWING EMERGENCY EXIT ESCAPE SLIDE RESERVOIR ACTUATING CABLE FOUND BROKEN. REPLACED LT OVERWING SLIDE RESERVOIR, INSPECTION OK.SDR SWAA072078Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01307Slide · out of positionAFT ENTRY DOOR (2L) SLIDE PRESSURE INDICATOR MIGRATING AWAY FROM WINDOW VIEW. [SUP 05-16-07] REPLACED SLIDE ASSEMBLY.SDR USAA070327Attach Fitting · corrodedFOUND CORROSION AFT GIRT BAR ATTACH FITTING, BS 344, S17L. FAB'D NEW ATTACH FITTING PER DWG 65C16121; CORROSION TASK C53-107-01; LEVEL 2, DEFECT SIZE: 1/2".SDR F3LA200700099Latch · missingDURING C-3 CHECK, INSPECTION REPORTED AFT OTBD NUTPLATE FOR THE AFT FILLER PLATE AROUND THE L2 DOOR GIRT BAR LATCH MISSING. REPLACED L2 DOOR SILL IAW SRM 51-42-11, FIG 6 AND 7.SDR 2007UALA01310Gauge · damagedLOW PRESSURE READING ON GAUGE. LEAK AROUND PRESSURE GAUGE THREADS. REMOVED PRESSURE GAUGE AND FOUND STRIPPED THREADS ON GAUGE AND GAUGE ADAPTOR. REPLACED GAUGE AND ADAPTOR, RECHECKED FOR LEAKS. CHECKS OK. TECHNICIAN LEFT AND NEW TECHNICIAN HAS BEEN GIVEN SDR SWAA072011Slide · dislodgedFOUND R1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR AALA20070736Slide · inoperativeGRU - LEFT NUMBER TWO DOOR ESCAPE SLIDE DETACHED FROM THE DOOR AND FELL DOWN TO THE TRUCK STAIR. SLIDE HANDLE NOT DISARMED WHEN THE DOOR WAS OPEN. REPLACED LEFT NUMBER TWO DOOR ESCAPE SLIDE AND DOOR ASSIST BOTTLE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 2007UALA01281Cable · frozenRT OVERWING SLIDE, MANUAL BACKUP CABLE IS FROZEN. [SUP 06-06-07] REPLACED CABLE, AND THE NON-FUNCTIONAL CABLE HAS BEEN THE ROOT CAUSE OF THE PROBLEM.SDR 2007UALA01272Slide · out of limitsDOOR 1L SLIDE IS OUT OF LIMITS. [SUP 05-18-07] SLIDE SHOULD READ NO LESS THAN 2975 AT 70 DFG, IT IS CURRENTLY READING 2500. REPLACED SLIDE. A/C RETURNED TO SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT SEAL DETERIORATION AT FILL VALVE PRESSURE HOSE CONNECTIOSDR SWAA072004Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01251Cover · looseDOOR 1R SLIDE PACK COVER APPEARS LOOSE. [SUP 05-18-07] SLIDE REMOVED FROM ACFT. REINSTALLED REPLACEMENT SLIDE. SLIDE BUSTLE REINSTALLED. A/C RETURNED TO SERVICE. SLIDE PROBLEM ROOT CAUSE: SUSPECT IMPACT BY CLEANING & FOOD SERVICE EQUIPMENT LOOSENED PACK COSDR 2007UALA01250Slide · out of positionDOOR 2R SLIDE PACK COMING OUT OF CONTAINER. [SUP 05-16-07] REPLACED SLIDE ASSEMBLY.SDR 2007UALA01249Slide · dislodgedSLIDE AT DOOR 2L DISLODGED. [SUP 05-16-07] REMOVED SLIDE PACK AND REPACKED SLIDE.SDR UPS07849665Slide · out of positionINSPECTION TYPE:N/A CREW DOOR ESCAPE SLIDE PRESSURE INDICATOR IS BELOW VIEWING WINDOW. REPOSITIONED SLIDE SO THAT PRESSURE INDICATOR IS BETTER VISIBLE.SDR 2007UALA01258Slide · activatedRAMP PERSONNEL FOUND DOOR 1L SLIDE OFF DOOR AND ON FLOOR. [06-14-07] REASSEMBLED AND REATTACHED SLIDE TO DOOR 1L PER UA ENGINEERING SPECIFICATIONS.SDR AWXA200700513Slide · failedMX REPORTED L-1 SLIDE WILL NOT STAY ARMED. MX REPLACED THE L-1 SLIDE. OPERATIONAL CHECK WAS GOOD.SDR SWAA071959Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01231Slide · wrong partDOOR 1R SLIDE IS THE WRONG PART. [SUP 05-18-07] REPLACED DOOR 1R SLIDE ASSY PER AMM 25-66-01 WITH THE CORRECT SLIDE P/N. NEW SLIDE INSTALLED IS MR25708 (649-9059).SDR 2007UALA01223Bottle · reads lowRIGHT EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE BULB WILL NOT TEST. [06-14-07] CONFIRMED BOTTLE PRESSURE SWITCH S10464 IS READING OPEN BETWEEN PINS A-C DUE TO INSUFFICIENT BOTTLE PRESSURE NOTED AT 2600 PSI. SWITCH IS DESIGNED TO OPEN WHEN BOTTLE PRESS REASDR 2007UALA01217O-Ring · unserviceableLOW BOTTLE PRESSURE. [SUP 05-16-07] GAUGE PORT O-RING LEAKING AND LEAKING AROUND PRESSURE GAUGE THREADS. REPLACED BOTTLE AND VALVE.SDR SWAA071898Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071896Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA071902Slide · unwanted deployR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR DL76S070400Slide · unserviceableRT FWD DOOR SLIDE RELEASE CABLE FOUND DETACHED DURING DOOR INSPECTION, THE R-1 DOOR SLIDE HAS BEEN REPLACED, S/N OFF PA0828.SDR SWAA071880Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01199Flange · crackedLEFT OVERWING SLIDE CONTAINER FLANGE CRACKED 12 INCHES ON AFT VERTICAL FLANGE AND 4 INCHES IN UPPER AFT CORNER. [06-22-07] REPLACED LT OVERWING SLIDE PACK.SDR SWAA071873Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071872Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071862Lanyard · brokenR1 DOOR EMERGENCY EVAC SLIDE LANYARD BROKEN. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA01160Strap · misroutedMED 2R SLIDE ARMING LEVER CAME OUT OF THE ARM POSITION IN FLIGHT (ALSO ECAM SHOWED NOT ARMED). PER SAMC CYCLED ARMING LEVER AND HANDLE WILL NOT ARM AND SLIGHT NOISE IN DOOR AREA. [06-12-07] FOUND GIRT BAR YELLOW STRAP WEDGED IN GIRT BAR MOUNT SLOT. RSDR 2007UALA01151Slide · faultyCABIN EMERGENCY LIGHTS CHECK SHOWS -ATA 33 -51-38 EXT LOADS FWD L- RE-SET CIDS, MESSAGE RE-APPEARED. REPLACED DOOR 1L ESCAPE SLIDE.SDR SWAA071839Window · looseL1 DOOR EMERGENCY EVAC SLIDE VIEWING WINDOW LOOSE. SECURED WINDOW PER MM.SDR DL76S070337Slide · unserviceableUPON REMOVAL OF THE R1 DOOR SLIDE BUSTLE IT WAS DISCOVERED THAT THE DOOR SLIDE HAD BECOME PARTIALLY UNLACED. IT APPEARS THAT ONE OF THE CABLES THAT ACTUATE THE CAM BAR WHICH RELEASES THE TENSION ON THE LACING CORDS WAS SOME HOW RELEASED. THE SLIDE WAS REPLASDR SWAA071858Slide · malfunctionedDURING SCHEDULED MV2 CHECK, UNSUCCESSFUL DEPLOYMENT OF R1 DOOR EMERGENCY EVAC SLIDE. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA01143Slide · faultyRIGHT OVERWING ESCAPE SLIDE CONTAINER AFT VERTICAL FRAME HAS APPROX 9 INCH CRACK FROM AFT LWR FASTENER UP TO CTR FASTENER. [SUP 06-06-07] REPLACED RT OVERWING ESCAPE SLIDE.SDR UPS07849616Slide · out of positionINSPECTION TYPE:N/A DOOR SLIDE FELL OUT OF CONTAINER WHEN DOOR WAS OPENED AT SDF. GIRT BAR WAS CORRECTLY STOWED. REINSTALLED SLIDE PER AMM 25-60-01-2.SDR SWAA071835Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071841Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071836Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA01139Slide · reads lowFWD GALLEY DOOR HAS LOW BOTTLE PRESS AND TORN GIRT. [SUP 5-1-07] REPLACED BOTTLE, TORN GIRT, AND SLIDE. CAUSE OF DISCREPANCY UNKNOWN.SDR 2007UALA01124Gauge · leakingLOW BOTTLE. *S/D* LEAKING THROUGH GAUGE FACE. CHANGED BOTTLE OUT WITH ANOTHER ONE. FIXED BOTTLE WITH BAD GAUGE AND PUT IT IN STOCK.SDR 2007UALA01125Disk · leakingLOW BOTTLE PRESSURE. *S/D* FOUND THERMAL DISK LEAKING. REPLACED THERMAL DISK.
Back to JASC 2565