Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR NWAA071295502Slide · dislodgedDURING OVERNIGHT CHECK, RAMP PERSONNEL OPENED DOOR 4 RIGHT AND ESCAPE SLIDE FELL OUT OF HOLDER ONTO THE RAMP. SLIDE WAS REMOVED AND AIRCRAFT WAS MAINTENANCE FERRIED TO DTW TO HAVE A NEW SLIDE INSTALLED. MAINTENANCE INSTALLED A NEW SLIDE AND GIRT BAR OPERATIONSDR SWAA071825Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01123Disk · rupturedLOW BOTTLE PRESSURE. *S/D* RUPTURE DISK FAILURE. CAUSE UNKNOWN. REPLACED RUPTURE DISK.SDR 07FDEA01416Light · inoperativeL1 DOOR RAFT BOTTLE PRESS TO TEST LIGHT INOP. REMOVED L1 DOOR LWR SLIDE RAFT COVER, REPLACED BATTERIES, L1 DOOR LOW PRESS BOTTLE LIGHT PRESS TO TEST GOOD. REINSTALLED L1 DOOR LWR SLIDE RAFT COVER IAW FX DC10 MM 25-61-01-2 TIMCO MECH 97827,7389. REMOVED L1SDR SWAA071791Slide · low pressureDURING SCHEDULED C3 CHECK, R2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA01075Bottle · reads lowDOOR 2R ASSIST BOTTLE LOW. [SUP 06-01-07] SERVICED ASSIST BOTTLE TO PROPER PRESSURE.SDR SWAA071774Hook · looseR1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED HOOK PER SRM.SDR 2007UALA01094Structure · bentMETAL PIECE ON SLIDE PACK BENT. [SUP 05-08-07] STRAIGHTENED UPPER FWD SLIDE PACK LATCH ON DOOR 1L. LATCH FUNCTION FULLY RESTORED AND SERVICEABLE. APPEARS METAL PIECE OF LATCH ON SLIDE PACK SNAGGED ON JET-BRIDGE OR OTHER AIRCRAFT SERVICE EQUIPMENT AND WAS DEFSDR 2007UALA01065Slide · dislodgedDOOR 2R SLIDE FELL OFF THE DOOR. *S/D* REINSTALLED SLIDE PACK.SDR SWAA071768Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01091Girt Bar · faultySLIDE PACK NOT ATTACHED. DOOR 4L GIRT BAR SLIDER FELL OFF. [06-14-07] INSTALLED 2EA GIRT BAR SLIDERS ON DOOR 4L. OPS CHECK GOOD. TESTED AND CHECKED ADJUSTMENTSDR SWAA071766Slide · out of adjustDURING SCHEDULED A2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071739Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR AALA20070803Slide · looseMEX - EMERGENCY SLIDE AT AFT GALLEY DOOR LOOSE. REPOSITIONED EMERGENCY SLIDE AT AFT GALLEY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR 07FDEA01345Bracket · corrodedMAIN ENTRY DOOR EMERG ESCAPE SLIDE, BACK PAN LWR LATCH HINGED RETAINER, MOUNT BLOCK HAS EXFOLIATION CORROSION. INSTALLED NEW BRACKET REF SRM 51-30-2 PG 2.SDR 2007UALA01017Cover · unsecureSLIDE PACK COVER 1L FELL OFF. [SUP 05-18-07] SECURED SLIDE COVER.SDR SWAA071707Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071698Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA01038Bottle · lowLOW BOTTLE PRESSURE. [SUP 05-16-07] WATER TESTED FOR LEAKS AND NO LEAK WAS FOUND. THE GAUGE STILL SHOWED IN THE GREEN. THE TECHNICIAN TOPPED OFF THE BOTTLE. SLIDE WAS IN AS A PART TIME SPARE.SDR 2007UALA01012Fastener · missingLEFT FWD ENTRY DOOR, FWD GIRT BAR FITTING MISSING FASTENER, FOUND DURING PRELIMINARY INSPECTION. [SUP 5-1-07] INSTALLED LT FWD ENTRY DOOR, FWD GIRT BAR FITTING FASTENER RETAINER. A/C OK FOR SERVICE.SDR SWAA071685Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00976Light · inoperativeDOOR R1 SLIDE ARMED LIGHT ABOVE DOOR INOPERATIVE. [06-14-07] REPLACED PROXIMITY SWITCH S10217.SDR NWAA071203255Terminal · brokenWHILE PERFORMING EMERGENCY OVERWING EXIT HATCH CHECK, THE FLEXIBLE CONTROL CABLE TERMINAL END WAS FOUND BROKEN. REPLACED LEFT OVERWING ESCAPE SLIDE RESERVOIR, INSPECTION OK.SDR MWEA070073Lanyard · misalignedMAIN CABIN DOOR SLIDE COVER CAME OFF AND GIRT BAR CABLE TO TIGHT. INSPECTED DOOR SLIDE COVER. FOUND SLIDE COVER TO BE INSTALLED PROPERLY. INSPECTED LANYARD CABLE, FOUND CABLE INSTALLED OVER SLIDE GIRT. REMOVED CABLE AND INSTALLED IN CORRECT POSITION.SDR SWAA071646Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071647Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA01005Slide · unsecureSLIDE PACK 1L HAS EXCESS FABRIC BELOW GIRT BAR DRAGGING ON FLOOR. [SUP 5-1-07] REPACKED BOTTOM SECTION OF SLIDE.SDR 2007UALA00980O-Ring · leakingLOW BOTTLE PRESSURE. ACTUATOR ASSEMBLY LEAKING. REPLACED WITH NEW VALVE.SDR 2007UALA00975Spring · brokenDOOR 4R SLIDE SPRING FOR CLIPS BROKEN. [06-14-07] REPLACED SLIDE.SDR 2007UALA00974Annunciator · inoperativeDOOR 2L SLIDE ARMED LIGHT INOPERATIVE. [06-14-07] REPLACED L405 GIRT BAR ANNUNCIATOR.SDR 2007UALA00962Slide · out of positionDOOR 1L SLIDE FELL PARTIALLY OUT OF COVER. [SUP 5-1-07] CAUSE IS UNKNOWN, REPLACED SLIDE.SDR 2007UALA00964Aspirator · leakingASPIRATOR LEAKING. CAUSE UNKNOWN DUE TO INTERNAL LEAKING. REPLACED ASPIRATOR.SDR 2007UALA00940Slide · reads lowTHE 1R SLIDE PRESSURE LOW. [SUP 05-16-07] REPLACED SLIDE.SDR 2007UALA00935Proximity Switch · inoperativeDOOR SLIDE LIGHT DOOR 2R DOES NOT ILLUM WHEN ARMED. [06-14-07] CHANGED LIGHT UNIT - NO HELP. REPLACED LIGHT BASE OPS CHECK NORMAL. REPLACED PROX SWITCH S10220 FOR ULTIMATE FIX.SDR SWAA071618Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA00932Spring · weakLEFT AFT MED DEPLOYMENT BAR GAS SPRING IS WEAK. [SUP 4-24-07] AFTER TROUBLESHOOTING FOUND WEAK GAS SPRING. REPLACED GAS SPRING PER MM 25-66-03. DEPLOYMENT BAR HAS PROPER SPRING TENSION. AIRCRAFT OK FOR SERVICE.SDR 2007UALA00925Slide · faultySLIDE LACING BROKEN ON TOP EDGE OF DOOR 5R SLIDE PACK. [SUP 4-24-07] AIR-SERVE REPORTS GIRT BAR AT DOOR 5R IS HANGING OUT OF BUSTLE. LACING APPEARS BROKEN ON TOP EDGE OF DOOR 5R SLIDE. REPLACED DOOR 5 RIGHT DOOR SLIDE PER MM 25-69-01. SUSPECT IMPROPER CINSDR AWXA200700424Slide · failedPHX - EES - R1 DOOR SLIDE EMERGENCY LIGHT TEST FAILED. MX REPLACED THE R1 DOOR SLIDE ASSY. OPERATIONAL CHECK WAS GOOD.SDR SWAA071604Hook · looseR1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED HOOK PER MM.SDR SWAA071605Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00915Bottle · unserviceableLOW BOTTLE PRESSURE. FOUND FUSIBLE PLUG LEAKING. REPLACED BOTTLE ON A/C. REMOVED AND REPLACED FUSIBLE PLUG ON UNIT.SDR 2007UALA00907Girt Bar · faultyDOOR 1L GIRT BAR COULD NOT HOOK IN TOTALLY. [SUP 4-20-07] AFTER TROUBLESHOOTING, TIGHTENED 3 STRAPS ON THE SLIDE PACK RELEASE ASSEMBLY. DOOR ARMING AND DISARMING OPERATED NORMALLY. AIRCRAFT RETURNED TO SERVICE.SDR 2007UALA00903Lanyard · mislocatedDOOR 2L SLIDE PACK LANYARD NOT VISIBLE. [06-14-07] FOUND D-RING STUCK UNDER SLIDE PACK. REPLACED LANYARD.SDR DL76G070269Door Latch · misinstalledRT OFF WING SLIDE COMPARTMENT DOOR LATCH 3RD FROM THE FRONT, FOUND INCORRECTLY INSTALLED. FOUND LATCH INSTALLED UPSIDE DOWN. REORIENTED LATCH.SDR SWAA071571Slide · out of adjustL1 DOOR EVACUATION SLIDE OUT OF ADJUST. ADJUSTED SLIDE ASSY PER MM.SDR 070076Retainer · brokenFLIGHT 9880 FAT/LAS - FLIGHT CREW REPORTED THAT THE MAIN PASSENGER ENTRY DOOR (L1) ESCAPE SLIDE NEEDS TO BE RE-ATTACHED TO THE DOOR. LAS MAINTENANCE REPORT THE REMOVAL AND REPLACEMENT OF A RETAINING CLIP AT L1 DOOR AND THE RE-MOUNTING OF THE ESCAPE SLIDE PER SDR 2007UALA00858Slide · dischargedSLIDE DISCHARGED 1L. [SUP 06-01-07] REPLACED DOOR 1L SLIDE AND ASSIST MECHANISM SEALING DIAPHRAGM. FILLED ASSIST BOTTLE TO PROPER PRESSURE.SDR SWAA071550Slide · unwanted deployL1 DOOR EVACUATION SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED SLIDE ASSY PER MM.SDR AWXA200700404Slide · no testPHX - EES - L-4 DOOR SLIDE DEPLOYMENT FAILED DUE TO THE SLIDE COVER. MX REPOSITIONED THE SLIDE COVER, DEPLOYMENT WAS NORMAL.SDR 2007UALA00857Bottle · underservicedLOW PRESSURE ON CYLINDER. [SUP 05-16-07] BOTTLE WAS UNDERFILLED. FILLED BOTTLE TO SPECIFICATIONS.
Back to JASC 2565