SDR SWAA071522Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2007UALA00871Slide · out of positionDOOR 1L SLIDE PACK FELL OUT OF HOUSING UPON OPENING OF DOOR INTACT. REPLACED SLIDE.SDR SWAA071464Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071463Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR 2007UALA00841Aspirator · leakingBOTH ASPIRATORS LEAKING BETWEEN JET PLATE ASSEMBLY AND SENSING TUBE. REPLACED BOTH ASPIRATORS. SUSPECT SIDE LOAD ON ASPIRATORS DURING PACKING CAUSED LEAKS.SDR SWAA071436Bottle · low pressureL1 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA071440Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071439Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 07FDEA01044Slide · malfunctionedL1 SLIDE DID NOT DEPLOY. SAFETY HAS SLIDE. REMOVED SLIDE ASSY MPN 7A1298-005, S/N WA0377, TURNED SLIDE OVER TO FLT SAFETY.SDR SWAA071426Bottle · low pressureDURING SCHEDULED MV1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00835Slide · low pressureDOOR 1L PRESSURE IS LOW. [SUP 06-01-07] REPLACED SLIDE PACK.SDR SWAA071433Bottle · low pressureDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2007UALA00834Slide · low pressureDOOR 1R SLIDE PRESSURE READS BELOW SERVICEABLE LIMIT. REPLACED R1 DOOR SLIDE PER MM 25-66-01. CAUSED BY SUSPECT SEAL LEAKAGE AT BOTTLE CONNECTION.SDR 2007UALA00832Cover · out of positionTHE 2L SLIDE COVER FELL OFF. [SUP 05-18-07] SECURED SLIDE COVER.SDR 2007UALA00801Slide · out of positionDOOR 1L SLIDE FELL OUT WHEN DOOR WAS OPENED. REPLACED SLIDE.SDR SWAA071420Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071427Bottle · low pressureDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE GAUGE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA071398Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR AALA20071791Slide · failedFLL - RIGHT NUMBER ONE DOOR SLIDE FELL TO RAMP WHEN DOOR OPENED BY CATERING. SLIDE WAS NOT ARMED. FOUND DEFECTIVE CLIPS THAT HOLD CHUTE INSIDE DOOR. SLIDE FELL OFF DOOR AND LANDED INTACT. DID NOT DEPLOY. PRESSURE INDICATOR IS DAMAGED AND UNREADABLE. REPLSDR AALA20071790Slide · failedSCU - LEFT NUMBER ONE DOOR SLIDE WAS LEFT IN ARMED POSITION AND SLIDE FELL ON AIRSTAIRS WHEN DOOR OPENED. SLIDE FAILED TO DEPLOY. REPLACED LEFT NUMBER ONE DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR UPS07849499Indicator · dislodgedDOOR SLIDE PRESS INDICATOR SLIDE OUT OF SIGHT. CANNOT READ. REPACKED/REPOSITIONED SLIDE INDICATOR, NOW IN VIEW.SDR ASAA0781550Slide · malfunctionedAFT ACCY COMPARTMENT EMERGENCY ESCAPE SLIDE FAILED TO DEPLOY DURING DEPLOYMENT TEST. INDICATION WAS THAT THE TAIL CONE STRAP (LANYARD) DETACHED FROM THE SLIDE COVER VELCRO TAB BEFORE THE COVER COULD BE PULLED OPEN. REPLACED COVER VELCRO TAB AND RETESTED SUCCSDR 2007UALA00760Girt Bar · out of adjustAFT GIRT BAR FLOOR FITTING CLEARANCE OUT OF ADJUSTMENT. [SUP 06-01-07] FOUND THAT THE GIRT BAR FLOOR FITTINGS WERE OUT OF ADJUSTMENT AND NOT ALLOWING THE GIRT BAR TO FREELY MOVE FROM THE DOOR FITTINGS TO THE SILL FITTINGS. THE FLOOR STRUCTURE AROUND DOOR 2R SDR 2007UALA00759Girt Bar · out of adjustDOOR 1L WILL NOT ARM. ADJUSTED GIRT BAR FLOOR LOCK, DOOR OPS CHECK OK.SDR 2007UALA00747Bottle · no test2R EMERGENCY ESCAPE SLIDE FAILS TEST. [SUP 05-22-07] REMOVED AND REPLACED BOTTLE ASSY. OPERATIONAL TEST OK.SDR 2007UALA00746Lamp · inoperativeDOOR 3R SLIDE ARMED LIGHT INOPERATIVE. [SUP 05-29-07] RELAMPED. OP CHECKED NORMALLY.SDR 2007UALA00742Torque Tube · damagedL-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. [SUP 05-22-07] L-1 DOOR LOWER GIRT BAR LINKAGE TORQUE TUBE IS GOUGED AND CORRODED. REPLACED TORQUE TUBE DURING DOOR OVERHAULS.SDR SWAA071339Slide · out of positionDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE ASSY PER MM.SDR SWAA071340Slide · out of positionDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EVACUATION SLIDE OUT OF POSITION. REPOSITIONED SLIDE ASSY PER MM.SDR SA07022Girt Bar · out of adjustPHL - THE CABIN CREW STATED THAT THE EMERGENCY ESCAPE SLIDE ARMING LEVER AT DOOR 4L KEEPS POPPING OUT. MAINTENANCE ADJUSTED THE GIRT BAR FITTING. OK FOR SERVICE.SDR 2007UALA00741Girt Bar · malfunctionedUNABLE TO DISARM SLIDE PACK WITH SAFETY PIN DOOR 4R. [SUP 05-18-07] FOUND DOOR 4R GIRT BAR AFT FOOT MISSING AND SLIDE NOT SERVICEABLE WHILE WORKING INBOUND GRIPE. REPLACED SLIDE AND GIRT BAR FOOT. GIRT BAR IS MOVING WHEN TRYING TO ARM. UNABLE TO DISARM SLIDSDR SWAA071338Slide · looseL1 DOOR EVACUATION SLIDE LOOSE. REPOSITIONED SLIDE ASSY PER MM.SDR SWAA071314Slide · out of positionL2 DOOR EVAC SLIDE OUT OF POSITION. REPOSITIONED SLIDE ASSY PER MM.SDR 2007UALA00734Girt Bar · lack of lubeTHE 3L DOOR WILL NOT DISARM. [SUP 05-18-07] LUBED GIRT BAR, OP'S CHECKED NORMAL ON GROUND. FOUND WATER UNDER GIRT BAR AREA INDICATING POSSIBLE ICE BUILD-UP IN THE AREA.SDR 2007UALA00717Aspirator · unserviceableBOTH ASPIRATORS DID NOT CLOSE SHUT WHEN DEPLOYED. SLIDE REPLACED. AIRCRAFT OK FOR SERVICE. REPLACED BOTH ASPIRATORS IN RIGHT O/W SLIDE. SUSPECT ASPIRATORS SUFFERED CRUSHED FLEX-CYLINDER DURING INSTALLATION.SDR 2007UALA00712Bottle · reads lowTWO EACH CABIN LIFE RAFTS, CYLINDER PRESSURE GAUGE NEEDLES ARE IN RED BAND (LOW PRESSURE). [SUP 05-18-07] LOW BOTTLE PRESSURE ATTRIBUTED TO A LEAKING GAUGE O-RING, WHICH APPARENTLY FAILED TO SEAL. FILL VALVE WAS FOUND LOOSE. TIGHTENED VALVE AND RETESTED.SDR 2007UALA00706Slide · unsecureSLIDE PACK 1R FELL OUT OF DOOR PACK BUT DID NOT ACTIVATE. [SUP 05-16-07] REINSTALLED SLIDE PACK.SDR SWAA071271Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA071254Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA071264Cable · misroutedDURING SCHEDULED SPV CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR 2007UALA00683Bottle · low pressureLOW BOTTLE PRESSURE. *S/D* GAUGE LEAKING AT TEFLON TAPE. REMOVED GAUGE & INSTALLED NEW TEFLON TAPE. RETESTED & CHECKS OK.SDR UPS07849334Girt Bar · malfunctionedINSPECTION TYPE:N/A GIRT BAR WILL NOT LATCH IN PLACE TO ARM THE SLIDE CHUTE WHEN DOOR IS CLOSED. REPOSITIONED SLIDE ON DOOR PER MM 25-60-00. OPS CHECK OK.SDR 2007UALA00669Module · intermittentF/A REPORTS UPPER DECK LEFT DOOR SLIDE LIGHT INOP. FOUND DOOR ANNUNCIATOR MODULE WORKING INTERMITTENTLY. NEEDS MODULE M7035. NO PCN ONLY P-N 65B48538-2. SEE IPC 52-23-15-001 ITEM 20. REPLACED MODULE. TESTED & FOUND OK FOR SERVICE.SDR SWAA071225Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SB07021Bottle · low pressurePHL - CREW REPORTED THE RIGHT AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE APPEARS TO BE IN THE RED. MAINTENANCE REMOVED AND REPLACED THE RIGHT AFT SERVICE DOOR EMERGENCY ESCAPE SLIDE PER MM 25-61-35-422-004.SDR 2007UALA00647Slide · brokenRIGHT OVERWING SLIDE PACK UNLACE TRIGGER IS BROKEN OFF. REPLACED SLIDE. A/C RETURNED TO SERVICE. SLIDE PROBLEM ROOT CAUSE: UNLACE TRIGGER FITTING BROKEN BY SIGNIFICANT IMPACT.SDR HALA0700077Relay · unknownDURING SQUIB TEST 1 LEFT EMER ESCAPE SLIDE INDICATOR LGT REMAINED EXTINGUISHED. DEAMRED LT/RT OVERWING SLIDES PER AMM 25-65-60, REPLACED LEFT DOOR SLIDE RELAYS K1 AND K3 ON M1135 MODULE. REPLACED BATTERIES FOR M961 AND M962. SQUIB TEST GOOD PER AMM 25-65-00SDR SWAA071174Slide · out of positionL2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR BB07026Light · failedDURING ACCOMPLISHMENT OF JOB CARD J825-60-10, ESCAPE SLIDE LIGHTS FAILED TO ILLUMINATE. CHECK MAINTENANCE REPLACED THE SLIDE ASSEMBLY.SDR 2007UALA00630Bottle · reads lowSLIDE AT DOOR 1L BOTTLE PRESSURE LOW. [SUP 05-08-07] WATER VALVE TESTED FOR LEAKS. FOUND THE SEAL WAS BROKEN INSIDE THE GAUGE AND BECAME NON-SERVICEABLE. REMOVED AND REPLACED GAUGE.
Back to JASC 2565