Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA062659Slide · low pressureL2 DOOR EMERGENCY EVAC SLIDE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA062653Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE IAW MM.SDR SWAA062600Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR SWAA062604Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062603Hook · looseL1 DOOR EMERGENCY EVAC SLIDE GIRT BAR HOOKS LOOSE. SECURED GIRT BAR HOOKS PER MM.SDR SWAA062602Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 200605Slide · low pressureL4 DOOR SLIDE LOW PRESSURE ON INFLATION BOTTLE.SDR 2006UALA01456O-Ring · failedFOUND DOOR 2R SLIDE BOTTLE PRESSURE IS LOW. SLIDE REPLACED. A/C OK FOR SERVICE. SLIDE PROBLEM ROOT CAUSE IS SLIDE BOTTLE PRESSURE LOW. O-RINGS ON CONNECTIONS TO BOTTLE HARDEN WITH TIME & LEAKED.SDR SWAA062594Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062588Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062582Hook · looseR1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR SWAA062575Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062574Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062567Hook · looseDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GIRT BAR FWD HOOK LOOSE. SECURED FWD GIRT BAR HOOK PER MM.SDR SWAA062563Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062562Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062554Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR MALA060481Slide · damagedPAX DOOR 2 RIGHT GIRT BAR END CAPS NOT YELLOW IN COLOR (WERE WHITE). REPLACED SLIDE ASSEMBLYSDR SWAA062551Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA062550Fitting · corrodedDURING SCHEDULED 10Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA062527Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062526Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06M47349Light · inoperativeINSPECTION TYPE:N/A DOOR 2L SLIDE INFLATION LOW PRESSURE LIGHT INTERMITTENT; PRESS TO TEST. CLEANED LIGHT ASSY CONTACTS; OPS CHECK GOOD.SDR 2006UALA01433Relief Valve · stuckDURING OPERATIONAL CHECK OF DOOR 4R POWER ACTUATING SYSTEM AND ESCAPE SLIDE, NR 2 PILLAR DID NOT FULLY INFLATE AND PRESSURE RELIEF VALVE ON RT SIDE STUCK OPEN. ACCOMPLISHED QUALITY ASURANCE OPERATIONAL CHECK OF DOOR 4R POWER ACTUATING SYSTEM AND ESCAPE SLIDE.SDR SWAA062519Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062512Slide · out of adjustDURING SCHEDULED MV2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062510Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062493Cable · frayedDURING SCHEDULED 20Y CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE GIRT BAR CABLE FRAYED. REMOVED AND REPLACED GIRT BAR CABLE PER MM.SDR SWAA062491Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE GIRT BAR AFT FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA062490Fitting · corrodedDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE GIRT BAR FWD FITTING CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR SWAA062478Fitting · looseDURING SCHEDULED 20Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED EVAC SLIDE FITTING PER MM.SDR SWAA062477Fitting · looseDURING SCHEDULED 20Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING LOOSE. SECURED EVAC SLIDE FITTING PER MM.SDR SWAA062476Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062475Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUST EVAC SLIDE PER MM.SDR 2006UALA01422Hose · brokenHOSE BROKEN AT SWIVEL. INCORRECT PACKING PROCEDURE. REPLACED HOSE.SDR SWAA062450Slide · out of adjustDURING SCHEDULED RON CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062449Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01395Pin · installedFWD GALLEY DOOR EVAC SLIDE HAS SAFETY PIN INSTALLED, NOT REMOVED AFTER MAINTENANCE. SAFETY PIN NOT REMOVED. REMOVED SAFETY PIN.SDR 2006UALA01394Battery Pack · failedSQUIB TEST ON EMERGENCY ESCAPE SLIDES WILL NOT TEST. REPLACED RIGHT AND LEFT SQUIB BATTERY PACKS PER AMM 25-65-17. SQUIB TESTS GOOD.SDR SWAA062426Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062404Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC PER MM.SDR SWAA062403Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062401Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062409Slide · out of adjustDURING SCHEDULED A1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062408Slide · out of adjustDURING SCHEDULED A1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR ASAA0680759Lanyard · wornINADVERTENTLY DEPLOYED TAIL CONE WHICH SHOULD HAVE ALSO CAUSED AFT EMERGENCY SLIDE TO DEPLOY. LANYARD VELCRO AND SNAP PULLED LOOSE FROM THE SLIDE COVER BUT THE SLIDE DID NOT DEPLOY. RETRIGGER SLIDE ASSEMBLY WITH NEW LANYARD. ENGINEERING INVESTIGATION HAS BESDR MWEA060142Slide · failedAFT GALLEY DOOR EVACUATION SLIDE FAILED TO DROP OUT OF DOOR DURING CHECK OF SLIDE DEPLOYMENT SYSTEM. MOUNTED SLIDE, OPERATIONAL CHECK GOOD.SDR 2006UALA01362Slide · dislodgedDOOR 1R SLIDE FELL OUT OF DOOR.SDR ASMF200607008Slide · incorrectAIRCRAFT RETURNED TO PLATFORM, RT DOOR NR 1 SLIDE WAS NOT ARMED CORRECTLY. SLIDE WAS ARMED IAW MM 25-66-01 AND DOOR WAS VERIFIED BY CONDITION, BEING ALL CORRECT.SDR SA06052Lanyard · tornLAX - DURING INSPECTION, FOUND THE R-1 DOOR EMERGENCY SLIDE/RAFT YELLOW LANYARD TORN. MAINTENANCE RELEASED THE AIRCRAFT ON MEL.
Back to JASC 2565