Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2006UALA01380Insert · missingLT OVERWING SLIDE DOOR ACTUATOR SQUIB SHUNT CAP MISSING INSERT. REPLACED 3SF5951-501 SHORTING CAP. OK FOR RETURN TO SERVICE.SDR AALA20060448Slide · inoperativeJFK - EMERGENCY SLIDE AT R2 DOOR DID NOT DEPLOY AUTOMATICALLY. DOOR FAILED TO OPEN FULLY WHEN MANUALLY DEPLOYED SLIDE. SLIDE PARTIALLY INFLATED IN DOORWAY. SLIDE RIPPED ON DOOR STOP. REPLACED EMERGENCY SLIDE AT RIGHT NUMBER TWO DOOR. SYSTEM GROUND CHECKEDSDR SWAA062359Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062350Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FITTING CORRODED. REMOVED AND REPLACED EVAC SLIDE AFT GIRT BAR FITTING PER SRM.SDR SWAA062349Fitting · corrodedDURING SCHEDULED 18Y CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR FITTING CORRODED. REMOVED AND REPLACED EVAC SLIDE FWD GIRT BAR FITTING PER SRM.SDR SWAA062393Slide · unwanted deployL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR 2006UALA01331Slide · faultyCABIN EMERGENCY LTS FAILED TEST IND EPSU EXT LOAD AFT L. TROUBLE SHOT SYSTEM. 2L SLIDE REPLACED PER MM 25-23-45.SDR SWAA062289Cable · frayedDURING SCHEDULED 20Y CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE FRAYED. REMOVED AND REPLACED EVAC SLIDE CABLE PER MM.SDR SWAA062322Window · missingR1 DOOR EMERGENCY EVAC SLIDE PLEXIGLASS WINDOW MISSING. INSTALLED PLEXIGLASS WINDOW PER MM.SDR SWAA062287Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA062286Slide · unwanted deployL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY DEPLOYED AT GATE. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA062275Slide · low pressureR1 DOOR EMERGENCY EVAC SLIDE INDICATED LOW PRESSURE. REMOVED AND REPLACED SLIDE PER MM.SDR UPS06M47286Light · brokenINSPECTION TYPE:N/A, RIGHT DOOR SLIDE TEST LIGHT BROKEN. DFRD ITEM PER MEL 25-61-2 M328551. REPLACED RIGHT ENTRY DOOR PRESS TO TEST LIGHT ASSY. OPS CHECK GOOD. M328551 CLOSED.SDR UPS06M47281Slide · unwanted deployL1 EVACUATION SLIDE/RAFT INFLATED; ENTRY DOOR SLIDE BLOWN. REMOVED AND REPLACED L1 DOOR SLIDE AS PER MD11 AMM 25-61-15-4 & SERVICED AS PER 52-11-04-5. OPS & LEAK CK'D GOOD. A/C OK FOR SERVICE. S/N ON 0278.SDR 2006UALA01294Handle · failedDOOR 2R ARMING HANDLE RAISED UP APPROX ONE QUARTER OF TRAVEL IN FLIGHT AND SLIDE DISARMED INDICATION APPEARED MOMENTARILY. ADJUSTED DOOR 2R PROXIMITY SWITCH FIN NUMBER 7WN2 ARM DISARM AMM-52-71-00-820-002-01.SDR 2006UALA01292Girt Bar · misinstalledDOOR 2 RT WILL NOT ARM. FOUND GIRT BAR FWD FLOOR MOUNT PLATE INSTALLED WITH TO MUCH SEALANT AFFECTING THE NORMAL HEIGHT OF GIRT BAR FLOOR MOUNT. REPOSITIONED FLOOR PLATE AND SEALED. OPS CHECKED GOOD.SDR NOCA9906Bulb · inoperativeL1 SLIDE DOOR ARMED LIGHT WILL NOT ILLUMINATE WHEN DOOR WAS ARMED. REPLACED LIGHT BULB, OPERATION CHECK NORMAL.SDR SWAA062260Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA062258Slide · low pressureR2 DOOR EMERGENCY EVAC SLIDE INDICATED LOW PRESSURE. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA062257Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR 2006UALA01278Slide · failedDOOR 1R SLIDE FAILS EXT LOADS TEST IN EMERGENCY LIGHTS TEST. REPLACED SLIDE 1R PER AMM 25-62-44.SDR SWAA062245Slide · low pressureDURING SCHEDULED MV1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATED OUT OF LIMITS. REMOVED AND REPLACED EVAC SLIDE PER MM.SDR SWAA062242Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062241Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062240Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR UPS06147269Warning Light · inoperativeWARNING LIGHT ON MAIN ENTRY DOOR EVAC SLIDE ARM HANDLE INOP. DFRD EVAC SLIDE ARM HANDLE LIGHT M328260 PER MEL 52-73-01-1 PLACARD INSTALLED. REPLACED AUTONOMOUS STANDBY POWER SUPPLY PER MM 52-73-18-04. REPLACED BATTERIES. CK'D OK PER MM 52-73-00-5. P/N ON:SDR SWAA062235Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA062234Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR SWAA062228Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR DL76S060701Linkage · misinstalledDURING INSPECTION OF THE LT OFF WING ESCAPE SLIDE PER JIC 6075 THE TECHNICIAN FOUND THAT THE INTEGRATOR LOCK HANDLE HAD TO BE FORCED INTO THE SAFETY POSITION. UPON FURTHER INVESTIGATION IT WAS DETERMINED THAT SLIDE DOOR OPENING ACTUATOR LINKAGE LEVER WAS INSTSDR WRNA200600025Slide · will not armR1 EVACUATION SLIDE ARMING LEVER DOES NOT ENGAGE EVACUATION SLIDE. LEVER IS STUCK IN DISENGAGED POSITION. PLACED ON MEL 52-61-01-2 CAT-C. LUBRICATED R1 EVACUATION SLICE ARMING LEVER MECHANISM. OPS CHECKED OK IAW A300 AMM 52-22-22. CLEARED MEL AND RELEASESDR AWXA200601054Slide · unserviceablePHX - EES - NR - 4100775 - DURING POST "C" CHECK, RETURN TO SERVICE CHECK, IT WAS DISCOVERED THAT THE R2 DOOR SLIDE PRESSURE WAS LOW. MAINTENANCE REMOVED AND REPLACED THE R2 DOOR SLIDE IAW T/C R1C25602.SDR SWAA062221Cable · misroutedDURING SCHEDULED C3 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR CNMA20060016Slide · damagedR-3 EVAC SLIDE DAMAGED (PARTIALLY DEPLOYED FOUND BY MAINTENANCE DURING CHECK). REMOVED AND REPLACED R-3 EVACUATION SLIDE IAW MM 25-61. REPAIR SHOP EVALUATION IS THAT THE ACTIVATION BOTTLE DISCHARGE FOR AN UNKNOWN REASON HOWEVER THE MAIN BOTTLE DID NOT DISCHARGSDR UPS06M47268Door · looseL1 SLIDE DOOR WOULD NOT STAY SECURED; L1 SLIDE DOOR FOUND SPEED TAPED SHUT. T/S FOUND L1 DOOR SLIDE LOWER FAIRING CAME OUT, REINSTALL L1 DOOR SLIDE LOWER FAIRING PER MM 25-61-15-4; FOUND SMALL ACCESS DOOR STAY SECURE. THIS CLEAR M328035. PLACARD INSTALLED.SDR SWAA062211Bracket · corrodedDURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR BRACKET CORRODED. REMOVED AND REPLACED AFT GIRT BAR BRACKET PER SRM.SDR SWAA062210Bracket · corrodedDURING SCHEDULED 1/2D CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR BRACKET CORRODED. REMOVED AND REPLACED FWD GIRT BAR BRACKET PER SRM.SDR SWAA062199Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR UPS06847256Gauge · unserviceableINSPECTION TYPE:N/A MAIN ENTRY DOOR EMERGENCY ESCAPE SLIDE PRESSURE GAUGE IS UNREADABLE. VERIFY IF SLIDE PRESSURE IS SERVICEABLE PER TC 0231, STEP 1D SLIDE PRESSURE IS SERVICEABLE PER TC 231, 1D.SDR SWAA062170Slide · out of positionR1 DOOR EMERGENCY EVAC SLIDE FELL OUT, DID NOT DEPLOY. INSTALLED EVAC SLIDE PER MM.SDR DL75K060702Slide · damagedPERFORMING A GENERAL VISUAL INSPECTION FOUND LT OVERWING SLIDE CARRIER HINGE PANEL LOOSE AND NOT SECURED. FURTHER INVESTIGATION FOUND SLIDE LACING UNSECURED AND SLIDE LOOSE IN CARRIER CONTACTING OVERWING SLIDE DOOR. REPLACED LEFT OVERWING EMERGENCY EXIT SLIDSDR 0601433239Slide · no testLEFT OVERWING SLIDE FAILED THE DEPLOYMENT TEST. SLIDE DEPLOYMENT CAUSED PROTECTIVE PLASTIC SHEETING TO BE SUCKED INTO THE SLIDE ASPIRATOR, RESULTING IN AN INCORRECT INFLATION OF THE SLIDE. A SECOND SLIDE DEPLOYMENT WILL BE SCHEDULED. SDR SB06064Bottle · low pressurePILOT REPORTED THE AFT LEFT ENTRY DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE IS LOW. MAINTENANCE REMOVED AND REPLACED THE AFT LEFT ENTRY DOOR EMERGENCY ESCAPE SLIDE ASSEMBLY. AIRCRAFT OK FOR SERVICE.SDR 2006UALA01224Adapter · leakingLOW BOTTLE PRESSURE, GAUGE THREADS AND GAUGE ADAPTER THREADS WERE DAMAGED. REPLACED VALVE ALONG WITH GAUGE AND GAUGE ADAPTER.SDR 2006UALA01225O-Ring · leakingLOW BOTTLE PRESSURE. O-RING ON FILL VALVE WAS LEAKING AND FOUND DAMAGED. REPLACED O-RING ON FILL VALVE.SDR 2006UALA01230Clamp · strippedRT OVERWING SLIDE CYLINDER CLAMPS ARE STRIPPED. REMOVED AND REPLACED SLIDE CYLINDER CLAMPS. OK FOR RETURN TO SERVICE. ROOT CAUSE WAS SUSPECTED TO BE OVER TORQUING OF SLIDE CYLINDER CLAMPS DUE TO IMPROPER MAINTENANCE TRAINING.SDR SWAA062157Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED EVAC SLIDE PER MM.SDR SWAA062154Cable · misroutedDURING SCHEDULED C2 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE GIRT BAR CABLE MISROUTED. REROUTED EVAC SLIDE CABLE PER MM.SDR WRNA200600026Slide · will not armR2 DOOR SLIDE WILL NOT ARM. REPLACED DOOR SLIDE IAW A300 25-61-11. RETURNED TO SERVICE.SDR 2006UALA01213Support · brokenCABIN - FWD RT PAX DR, EMERGENCY SLIDE FWD SUPPORT LUG BROKEN. FWD FLANGE BROKEN THROUGH PIN SUPPORT HOLE. AFT FLANGE BROKEN OFF AT BASE OF FLANGE. THIS OCCURRENCE ATTRIBUTED TO FAILURE OF ONE OF THE COMPONENTS SUPPORTING THE SLIDE, CAUSING A CHAIN OF ATTAC
Back to JASC 2565