Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA051470Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR ASMF200505023Slide · deployedDURING TRANSIT CHECK THE GROUND HANDLING SERVICES COMPANY PERSONNEL OPERATED THE AFTER EXIT DOOR IN THE EMERGENCY FORM, WHICH RESULTED IN THE TAILCONE SEPARATION AND DEPLOYMENT OF THE EVACUATION SLIDE. THE TAIL CONE HIT THE GROUND AND HAD A 6 X 2 INCH CRACK, SDR ABXA050122Slide · deployedLIFE RAFT SLIDE DEPLOYED WITHOUT BEING ARMED. THE LOWER FORWARD ENTRY DOOR HUNG WHILE TRYING TO CLOSE IT. WHEN THE DOOR WAS RAISED FOR RE-CLOSURE, THE SLIDE DEPLOYED. INSPECTED DOOR AND GIRT BAR ATTACHMENTS. NO DEFECTS NOTED. REMOVED AND REPLACED SLIDE ASSDR SA05054Servo Valve · failedDURING TAKE-OFF ROLL, THE BRAKES BEGAN TO SURGE, CAUSING THE AIRCRAFT TO VEER ON THE RUNWAY. AT THE SAME TIME, A BRAKE SYSTEM 1 FAULT ECAM MESSAGE GENERATED. THE TAKE-OFF WAS REJECTED AT 40 KNOTS. THE FLIGHT RETURNED TO THE GATE WITHOUT FURTHER INCIDENT. MSDR SWAA051467Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA051459Hook · looseDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE FWD GIRT BAR HOOK LOOSE. SECURED HOOK PER SRM.SDR SA05053Line · misroutedPIT - MAINTENANCE FOUND THE FORWARD, RIGHT SIDE, DOOR EMERGENCY ESCAPE SLIDE ASSEMBLY MOORING LINE INCORRECTLY ROUTED. MAINTENANCE CORRECTLY ROUTED THE MOORING LINE. OK FOR SERVICE.SDR 2005UALA00459Aspirator · fodPLASTIC BLOCK FOUND IN ASPIRATOR. THE PLASTIC BLOCK FOUND STUCK IN THE ASPIRATOR IS A FOREIGN OBJECT THAT IS NOT PART OF THE SLIDE ASSY. THIS TEFLON BLOCK WITH BEVELED CORNERS AND WITH A RED STRAP LOOKS LIKE IT HAD BEEN SPECIALLY FABRICATED FOR SOME UNKNOWN SDR BB05040Slide · detachedPHL - L1 DOOR SLIDE LIGHT INOPERATIVE. MAINTENANCE REATTACHED THE GIRT BAR CHUTE TO THE SLIDE ASSEMBLY.SDR ABXA050120Girt Bar · contaminatedCREW REPORTED MAIN ENTRY DOOR SLIDE WOULD NOT ARM. CHECKED FOR DEBRIS IN GIRT BAR AREA. CLEARED AREA AND CYCLED DOOR. DOOR CHECKED GOOD. SLIDE ARMS AND DISARMS.SDR SWAA051450Latch · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE GIRT BAR LATCH ASSY OUT OF ADJUST. ADJUSTED LATCH ASSY PER MM.SDR UPS05144492Cylinder · dischargedMAIN CABIN DOOR SLIDE INOPERATIVE. SERVICED FWD DOOR EMERGENCY ACTUATOR CYLINDER PER MM 52-10-14-3. THIS CLEARS M302648.SDR SWAA051444Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR SWAA051430Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. INSTALLED SLIDE PER MM.SDR SWAA051417Slide · out of adjustL2 & R2 EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR AWXA200500561Slide · faultyLAS - EEL - DURING 8-DAY CHECK THE EMERGENCY LIGHT SYSTEM TEST FAILED FOR EPSU EXT LOAD FWD L. MAINTENANCE ISOLATED PROBLEM TO THE L-1 DOOR SLIDE, REMOVED AND REPLACED L-1 DOOR SLIDE ASSEMBLY, OPERATIONAL CHECK WAS GOOD.SDR 2005UALA00449Slide · fodWHEN SLIDE OPENED THERE WAS A SANDBAG AND SCREWDRIVER PACKING INSIDE SLIDE. COMPONENT SHOP MAINTENANCE QUALITY ISSUE. SHOP MECHANIC TRAINING COULD BE THE PROBABLE CAUSE. SHOP THAT PERFORMED THIS DISCREPANT PACKING NO LONGER EXISTS. SLIDE IS NOW MAINTAINED SDR SWAA051412Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR P9RA20050079Girt Bar · dirtySFB GATE ITEM P1, L2 DOOR WILL NOT DISARM. CLEANED AND LUBRICATED GIRT BAR IAW MM. OPERATIONAL CHECKED NORMAL.SDR 2005UALA00448Slide · damagedSLIDE HAD BEEN DEPLOYED CAUSING HOLES IN INFLATION TUBE AND HEAVY SEAM DEGRADATION. PROBABLE CAUSE OF HOLES IN THE INFLATABLE IS FOREIGN OBJECT DAMAGE (FOD) DURING DEPLOYMENT OR PERHAPS DUE TO HANDLING DURING TRANSPORTATION. SINCE THE DAMAGE WAS BEYOND THE CSDR SWAA051390Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051379Hook · out of adjustR2 DOOR EMERGENCY EVAC SLIDE GIRT BAR STOW HOOKS OUT OF ADJUST. ADJUSTED HOOKS PER MM.SDR 2005UALA00447Slide · tornTORN INFLATABLE SEAM IN DOG LEG. BEYOND SCOPE OF CMM. SEAM AT DOGLEG DISBONDED DURING AIR RETENTION TEST. DISBOND WAS BEYOND CMM REPAIR LIMITS. UNIT WAS RETURNED TO OEM FOR REPAIR AND INFLATABLE WAS REPLACED.SDR SWAA051377Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051370Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR SWAA051365Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UPS05144435Slide · malfunctionedSLIDE HARD TO ARM HAD TO RECYCLE ARMING HANDLE SEVERAL TIMES IN ORDER TO GET A SLIDE ON ECAM. CYCLED EMERGENCY ESCAPE SLIDE RELEASE HANDLE SEVERAL TIMES WITH SLIDE APPEARING ON ECAM HANDLE WAS SMOOTH IN OPERATION IN REF TO MM 52-73-00-0.SDR 2005UALA00433Fitting · damagedINFLATION HOSE WAS SNAPPED AT THE ASPIRATOR. HOSE ASSEMBLY FITTING BROKEN DURING PREVIOUS PACKING OF THE SLIDE ASSEMBLY. REMOVED BROKEN HOSE AND REPLACED WITH ONE FROM UAL INVENTORY.SDR SWAA051359Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SB05058Cable · inoperativePIT - THE R2 DOOR SLIDE LANYARD WOULD NOT RELEASE. MAINTENANCE REPLACED THE SLIDE.SDR AU510001571Slide · faultyDOOR L1 ESCAPE SLIDE PRESSURE OUTSIDE OF OPERATING RANGE.SDR SWAA051352Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1 & R2 DOOR EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR SWAA051340Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR BB05034Module · faultyPHL - DURING SQUIB TEST, THE NR 2 EMERGENCY ESCAPE SPOILER INDICATION REMAINED EXTINGUISHED. MAINTENANCE REPLACED THE M1136 MODULE AND RELAYS K839 AND K838.SDR SWAA051333Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00404Bottle · lowLOW BOTTLE PRESSURE.SDR SWAA051304Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR DL76L050247Slide · unserviceableINADVERTENT SLIDE DEPLOYMENT AT R1 DOOR BY MTC PERSONNEL. DEPLOYMENT SUCCESSFUL.SDR SWAA051277Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051251Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 & R1 DOOR EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR SWAA051248Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00391Gauge · defectiveDOOR 2R LOW SLIDE PRESSURE. PRESSURE GAUGE WAS FALLING APART. NO FAULT FOUND. INSPECTION OF PRESSURE VESSEL/VALVE ASSEMBLY REVEALED NO DISCREPANCIES. UNIT WAS OVERHAULED AND RETURNED TO SERVICE.SDR SWAA051245Hook · looseDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR HOOK LOOSE. SECURED HOOK PER MM.SDR SWAA051243Slide · out of adjustDURING SCHEDULED SERVICE CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051217Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051213Girt Bar · crackedDURING SCHEDULED C1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE AFT GIRT BAR FLOOR FITTING CRACKED. REMOVED AND REPLACED FLOOR FITTING PER MM.SDR SWAA051211Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051222Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA051210Girt Bar · out of adjustR2 DOOR EMERGENCY EVAC SLIDE GIRT BAR DIFFICULT TO REMOVE FROM FLOOR FITTINGS. ADJUSTED SLIDE & REMOVED DEBRIS FROM GIRT BAR FITTINGS PER MM.SDR SWAA051205Slide · dislodgedL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE ASSY PER MM.
Back to JASC 2565