Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA051204Slide · dislodgedR2 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE ASSY PER MM.SDR SWAA051200Slide · out of limitsDURING SCHEDULED MV2, FOUND R2 DOOR EVACUATION SLIDE PRESS IND OUT OF LIMITS. REMOVED AND REPLACED SLIDE ASSY PER MM.SDR SWAA051194Slide · out of adjustR1 DOOR EVACUATION SLIDE PRESS IND OUT OF VIEW. ADJUSTED SLIDE ASSY PER MM.SDR SWAA051197Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EVACUATION SLIDE PRESS IND OUT OF VIEW. ADJUSTED SLIDE ASSY PER MM.SDR SWAA051192Slide · dislodgedL1 DOOR EVACUATION SLIDE FELL OUT OF CONTAINER (DID NOT DEPLOYED). REINSTALLED SLIDE ASSY PER MM.SDR BB05031Lifter · out of positionCLT - THE EVACUATION SLIDE ARMING LEVER AT DOOR L2 WAS BINDING. MAINTENANCE FOUND THE GIRT BAR LIFTER PRESSING ON THE GIRT BAR AND ADJUSTED IT.SDR AALA20050335Slide · failedTUL - EMERGENCY ESCAPE SLIDE AT STATION 326 HAD TO BE INFLATED MANUALLY. REPLACED EMERGENCY ESCAPE SLIDE AT STATION 326. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWAA051190Slide · out of adjustR1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051186Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00385Reservoir · lowFILL ON LOW SIDE OF GREEN BAND WITHIN MANUAL TOLERANCE. SLIDE WAS REMOVED FROM AIRCRAFT DUE TO LOW INFLATION CYLINDER PRESSURE. WHEN RECEIVED AT COMPONENT SHOP, PRESSURE INDICATOR NEEDLE WAS REPORTED TO STILL BE WITHIN THE GREEN 'GO' BAND. RESERVOIR PRESSURESDR 2005UALA00380Slide · dislodgedEMERGENCY ESCAPE SLIDE AT DOOR 1R CAME UNPACKED AND FELL ON THE FLOOR. WHEN TIGHTLY-PACKED SLIDES ARE OPENED (DURING INSPECTION OR WHILE REMOVING/INSTALLING THE SAFETY PIN) THE SLIDE EXPANDS, CAUSING VALISE LOOP AND HOOK TAPE AND COMPARTMENT/CLAMSHELL LATCH SDR AALA20050325Spring · inoperativeAFW - SPRING ON RIGHT NR 1 DOOR PER AD 2001 26 19 WILL NOT STAY IN COTTER PIN. FORWARD SPRING RIGHT NUMBER ONE DOOR ON GIRT BAR. REPLACED GIRT BAR ON RIGHT NUMBER ONE DOOR.SDR SWAA051166Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SA05040Slide · deflatedTHE AFT LEFT DOOR SLIDE DEPLOYED WITHOUT INFLATING. MAINTENANCE REPLACED THE AFT LEFT EMERGENCY ESCAPE SLIDE.SDR SWAA051144Bottle · dischargedDURING SCHEDULED SERVICE CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA051141Slide · out of limitsL1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA051133Latch · missingR2 DOOR EMERGENCY EVAC SLIDE GIRT BAR FLOOR LATCH SPRING MISSING. REMOVED AND REPLACED LATCH ASSY PER MM.SDR SWAA051118Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051115Latch · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE RELEASE MECHANISM OUT OF ADJUST. ADJUSTED RELEASE MECHANISM PER MM.SDR MWEA050033Slide · failedTAIL CONE SLIDE DID NOT AUTOMATICALLY DEPLOY WHEN THE TAIL CONE TEST WAS PERFORMED. REPLACED SLIDE COVER ASSEMBLY AND SLIDE.SDR 2005UALA00334Girt Bar · damagedGIRT BAR ENGAGEMENT LIGHT EXTINGUISHED WITH EVACUATION SLIDE ARMING LEVER IN ENGAGED POS AT DOOR. DOOR 3R GIRT BAR ENGAGEMENT LIGHT INOP.SDR AALA20050267Slide · out of positionRDU - EMERGENCY ESCAPE SLIDE AT LEFT NUMBER ONE DOOR FELL OFF. INSPECTED AND REPLACED EMERGENCY ESCAPE SLIDE AT LEFT NUMBER ONE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR AALA20050266Pin · migratedRDU - PINS MIGRATED OUT OF EMERGENCY SLIDE AT LEFT NUMBER ONE DOOR. REPLACED LEFT NUMBER ONE EMERGENCY SLIDE DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR SWAA051068Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA051062Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA051052Slide · out of adjustR1 & R2 DOOR EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR SWAA051069Slide · out of positionL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER UPON DOOR OPENING. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR SWAA051045Slide · out of positionR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR 2005UALA00369Aspirator · leakingDAMAGED ASPIRATOR, FLAPPER VALVE. SUPPORT ROD LOOSE. FLAPPERS WERE LEAKING. REPLACED OF THE ASPIRATOR.SDR 2005UALA00327O-Ring · leakingLOW PRESSURE ON CYLINDER. O-RING LEAK AT FILLER VALVE FITTING. REPLACED O-RING.SDR 2005UALA00326Aspirator · leakingASPIRATOR FLAPPER VALVE LEAKS. LEAKAGE OF ASPIRATOR FLAPPER VALVE. ASPIRATOR WAS REPLACED.SDR SWAA051034Slide · unserviceableDURING SCHEDULED A2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA051032Slide · out of adjustL2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UPS05844239Bottle · dischargedESCAPE SLIDE BOTTLE PRESSURE 2000 LBS. REMOVED AND REPLACED ESCAPE SLIDE.SDR SWAA051010Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE, FWD & AFT GIRT BAR FLOOR FITTINGS CORRODED. REMOVED AND REPLACED FLOOR FITTINGS PER SRM.SDR UPS05144240Handle · stuckUNABLE TO DISARM SLIDE. LUBRICATED ARMING HANDLE, ARMED & DISARMED SLIDE SEVERAL TIMES. CHECKED ESCAPE SLIDE IAW MM 25-61-20-6, FOUND SATISFACTORY.SDR DL757050203Slide · deployedRT OVERWING SLIDE DEPLOYMENT OCCURRED WHILE ORF POLICE SWAT TEAM WAS TRAINING ON BOARD A/C. DEPLOYMENT WAS SUCCESSFUL.SDR SWAA051005Hook · out of positionL2 DOOR EMERGENCY EVAC SLIDE GIRT BAR HOOKS OUT OF POSITION. REPOSITIONED HOOKS PER MM.SDR SWAA051002Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. INSTALLED SLIDE PER MM.SDR GTIA050119Slide · failedAFT SERVICE DOOR EVAC SLIDE DID NOT DEPLOY DURING OPS CHECK, FIRING LANYARD FAILED TO PULL OUT OF FIRING MECHANISM. AFT SERVICE DOOR EVAC SLIDE TO BE REPLACED ON WORK CARD 7809-1-01086/05. (M)SDR 2005UALA00293Aspirator · crushedFOUND LOWER TUBE ASPIRATOR CRUSHED. SLIDE WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. DAMAGED ASPIRATOR WAS OBSERVED DURING SHOP MAINTENANCE. THE EXACT CAUSE OF THE DAMAGE TO THE ASPIRATOR COULD NOT BE DETERMINED.SDR CALA0500098Slide · dischargedINSPECTION FOUND THE L-2 DOOR EMERGENCY ESCAPE SLIDE BOTTLE PRESSURE LOW. THE SLIDE ASSEMBLY WAS REPLACED IAW MM 25-61-35.SDR SWAA050995Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. INSTALLED SLIDE PER MM.SDR SWAA050992Slide · dischargedDURING SCHEDULED A1 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED SLIDE PER MM.SDR 2005UALA00373Slide · tornMULTIPLE HOLES AND TEARS IN THE INFLATABLE. CAUSE UNKNOWN, SLIDE REPAIRED PER OEM MAINTENANCE/REPAIR MANUAL.SDR 2005UALA00368Barrel · damagedDAMAGED ASPIRATOR BARREL. THE EXACT CAUSE OF DAMAGE TO THE ASPIRATOR COULD NOT BE DETERMINED, INVESTIGATION HAS ATTRIBUTED THE CAUSE TO ACCIDENTAL DAMAGE DURING THE LAST PACKING PROCESS.SDR SWAA050986Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00367O-Ring · leakingLOW SLIDE PRESSURE. PRESSURE LOSS WAS DUE TO LEAKAGE AT RESERVOIR TO VALVE O-RING. O-RING WAS REPLACED.SDR 2005FA0000577Quick Disconnect · looseDURING A C-CHECK, THE QUICK DISCONNECT WHICH CONNECTS THE SLIDE RELEASE CABLE TO THE RELEASE MECHANISM ON THE PACKBOARD ASSY WAS FOUND LOOSE. THE ELECTRICAL LOOM WAS CONFIGURED FOR A LT DOOR. (K)SDR 2005FA0000576Quick Disconnect · missingWHILE CARRYING OUT A SAMPLE INFLATION ON THE AFT ENTRY DOOR, THE ESCAPE SLIDE FAILE TO RELEASE FROM THE PACK DUE TO THE QUICK DISCONNECT, PN 25C150911, WHICH CONNECTS THE SLIDE RELEASE CABLE TO THE RELEASE MECHANISM ON THE PACKBOARD ASSY BEING MISSING.(K)
Back to JASC 2565