Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR 2005FA0000574Light · failedTHE ESCAPE SLIDE LIGHTS DID NOT WORK DUE TO THE CONNECTOR NOT FULLY HOME. THE ELECTRICAL LOOM AND THE CONNECTOR WERE NOT STOWED PROPERLY. (EA33200501197) (K)SDR SWAA050970Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050962Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00281Flapper Valve · damagedDAMAGED ASPIRATOR FLAPPER VALVE. SLIDE/RAFT WAS REMOVED FROM AIRCRAFT AT NORMAL MAINTENANCE INTERVAL. DAMAGED ASPIRATOR FLAPPER VALVE WAS OBSERVED DURING SLIDE/RAFT MAINTENANCE. THE EXACT CAUSE OF THE DAMAGE COULD NOT BE DETERMINED.SDR SWAA050950Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR SWAA050953Hook · looseL1 DOOR EMERGENCY EVAC SLIDE GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR SA05035Strap · looseMSP - FLT 910 EN ROUTE CLT TO MSP, AFTER TAKEOFF, THE AFT RIGHT DOOR SLIDE DISARM INDICATION CAME ON ECAM. THE CABIN CREW FOUND THAT THE SLIDE ARM HANDLE HAD COME OUT OF DETENT, AND WOULD NOT STAY DOWN. FLIGHT CONTINUED AND LANDED WITHOUT FURTHER INCIDENT. SDR UPS05144199Light · inoperativeSLIDE TEST LIGHT ON MAIN ENTRY DOOR INOP. REMOVED AND REPLACED ASPSU BATTERY PACKS IAW MM 52-73-18-4, CKS GOOD IAW MM 52-73-00-1 501.SDR SWAA050905Hook · looseR1 DOOR EMERGENCY EVAC SLIDE GIRT BAR STOW HOOK LOOSE. SECURED HOOK PER MM.SDR AWXA200500422Slide · will not testDURING SCHEDULED DEPLOYMENT OF THE R-3 DOOR SLIDE, THE SLIDE EXCEEDED INFLATION TIME FAILING THE TEST, SLIDE TOOK 13 SECONDS TO BECOME FULLY INFLATED. MAINTENANCE REMOVED AND REPLACED THE R-3 DOOR SLIDE ASSEMBLY. FOUND NO OBVIOUS REASON WHY SLIDE EXCEEDED DESDR SWAA050882Cable · misroutedDURING SCHEDULED RON CHECK, FOUND L2 DOOR EMERGENCY EVAC SLIDE LATCH CABLE MISROUTED. REROUTED CABLE PER MM.SDR AALA20050213Girt Bar · inoperativeDFW - THE GIRT BAR AT AFT GALLEY DOOR BECAME DISLODGED AND PIN CAME PARTIALLY OUT PREVENTING RESETTING SLIDE LANYARD. REPLACED SLIDE ASSEMBLY FOR AFT GALLEY DOOR. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR YENA200524Bottle · dischargedDURING DAILY CHECK FOUND R-2 DOOR SLIDE BOTTLE PRESSURE TO BE LOW AND IN RED. REMOVED AND REPLACED R-2 SLIDE.SDR BB05021Light · inoperativeBFM DURING ANNUAL SLIDE INFLATION CHECK, THE EMERGENCY LIGHTS DID NOT ILLUMINATE. MAINTENANCE REPLACED THE SLIDE. FURTHER INFORMATION PENDING.SDR SWAA050866Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050865Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR SWAA050872Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050864Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-INSTALLED SLIDE PER MM.SDR SWAA050852Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA050842Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. RE-INSTALLED SLIDE PER MM.SDR SWAA050861Slide · out of limitsDURING SCHEDULED MV2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING OUT OF LIMITS. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA050860Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR 2005UALA00282Aspirator · leakingTHE ASPIRATOR LEAKING BY BARREL. REPLACED ASPIRATOR.SDR SWAA050843Slide · dislodgedR2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED SLIDE PER MM.SDR SWAA050841Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050826Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR UPS05144133Warning Light · will not testSLIDE SYSTEM WARNING LIGHT WILL NOT PRESS TO TEST. LIGHT OP. PERFORMED TEST OF EVACUATION WARNING SYS ON MAIN ENTRY DOOR, OPS CK GOOD. ITEM CLEARED M299091SDR SWAA050825Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050818Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED SLIDE PER MM.SDR SWAA050817Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 & L1 DOOR EMERGENCY EVAC SLIDES OUT OF ADJUST. ADJUSTED SLIDES PER MM.SDR SWAA050815Slide · dischargedDURING SCHEDULED MV2 CHECK, L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATED LOW. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA050812Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF HOUSING. SLIDE DID NOT DEPLOY. REINSTALLED SLIDE PER MM.SDR 2005UALA00284O-Ring · leakingLOW BOTTLE PRESSURE. RESERVOIR/VALVE ASSEMBLY PRESSURE GAGE O-RING LEAKING. REPLACED O-RING.SDR SWAA050799Indicator · out of positionL2 DOOR EMERGENCY EVAC SLIDE INDICATOR OUT OF VIEW. REPOSITIONED SLIDE PER MM.SDR SWAA050772Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON L1 DOOR EVAC SLIDE GIRT BAR FLOOR FITTINGS. REMOVED AND REPLACED FITTINGS PER SRM.SDR SWAA050770Slide · reads lowL1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED SLIDE PER MM.SDR SWAA050788Bracket · looseDURING SCHEDULED 1/4D CHECK, FOUND R2 DOOR EVAC SLIDE GIRT BAR FLOOR AFT BRACKET LOOSE.SDR AMTA200500257Slide · failedWHILE COMPLYING WITH WORK CARD 382F2501 L1 SLIDE, SN NG4084, FAILED TO DEPLOY WITH EITHER NORMAL OR MANUAL DEPLOY PROCEDURES. SLIDE WAS REPLACED AND OPS CHECK NORMAL. (K)SDR 2005UALA00241Warning Light · malfunctionedDOOR 3L SLIDE LIGHT WOULD NOT GO OFF WITH DOOR DISARMED. ALTHOUGH UNABLE TO DUPLICATE INCIDENT, IT IS SPECULATED CONDITION WAS CAUSED BY DIRT OR DEBRIS ON PROXIMITY SENSORS WHICH AFFECTS THE INDUCTANCE NECESSARY FOR SYSTEM OPERATION.SDR SWAA050761Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-INSTALLED SLIDE PER MM.SDR SWAA050760Slide · out of adjustL1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. RE-INSTALLED SLIDE PER MM.SDR P9RA20050071Girt Bar · stickingAIRCRAFT AT GATE; CANCUN, L4 DOOR SLIDE GIRT WOULD WOULD NOT ENGAGE. CLEANED AND LUBRICATED GIRT BAR. GIRT BAR ENGAGED PROPERLY.SDR 2005UALA00283O-Ring · leakingLOW BOTTLE PRESSURE. RESERVOIR/VALVE ASSEMBLY SHAFT O-RING LEAKING. REPLACED SHAFT O-RING AND BACK-UP O-RING.SDR SWAA050762Slide · dischargedL2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED SLIDE PER MM.SDR BB05014Girt Bar · obstructedTHE L4 DOOR WOULD NOT ARM PROPERLY. MAINTENANCE RESTOWED THE SLIDE PACK WHICH WAS OBSTRUCTING THE GIRT LINKAGE.SDR SWAA050739Slide · out of adjustR2 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. REINSTALLED SLIDE PER MM.SDR SWAA050732Hook · looseDURING SCHEDULED 1/4D CHECK, FOUND BOTH R1 & L1 DOOR EMERGENCY EVAC SLIDE GIRT BAR HOOKS LOOSE. SECURED HOOKS PER MM.SDR SWAA050723Girt Bar · corrodedDURING SCHEDULED D-CHECK, FOUND CORROSION ON L1 DOOR EVAC SLIDE, FWD & AFT GIRT BAR FLOOR FITTINGS. REMOVED AND REPLACED GIRT BAR FITTINGS PER SRM.SDR UPS05144034Indicator · inoperativeNO ENTRY DOOR SLIDE ECAM IND WHEN DOOR ARMED. DEFERRED PER MEL 52-30-04. PLACARD INSTALLED M298435. R&R SWITCH 13WN OPS CK. NORMAL REF MM 52-73-13-4 THIS CLEARS M298435SDR SWAA050715Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. SLIDE DID NOT DEPLOY. REINSTALLED L1 DOOR SLIDE PER MM.
Back to JASC 2565