SDR ASAA0580091Lanyard · brokenOKC - HV-CHECK, FORWARD PAX (L-1) DOOR EMERGENCY EXIT SLIDE FAILED TO DEPLOY DURING TEST PER TASKCARD 28425002 STEP 2. THE CAUSE WAS DETERMINED TO BE A BROKEN GIRT BAR-TO-SLIDE COVER LATCH LANYARD. IT WAS BROKEN AT THE LATCH END. THE ENTIRE EMERGENCY SLIDE SDR UPS05143870Slide · reads lowEMERGENCY ESCAPE SLIDE PRESSURE SHOWS IN THE RED M296931 ASSIGNED. INSPECTED L1 ESCAPE SLIDE AND FOUND PRESSURE WITHIN LIMITS PER MM 25-61-21-4 OK FOR SVD, PLACARD REMOVED.SDR SWAA050400Hook · corrodedDURING SCHEDULED 1/2D CHECK, FOUND GIRT BAR FLOOR FITTING ASSY AT BS 344, LBL 59, CORRODED. REMOVED AND REPLACED GIRT BAR FITTING ASSY PER SRM.SDR SWAA050395Slide · reads lowDURING SCHEDULED RON, FOUND L2 DOOR EVAC SLIDE LOW PRESSURE IND. REMOVED AND REPLACED L2 DOOR EVAC SLIDE PER MM.SDR SWAA050394Slide · dislodgedDURING SCHEDULED RON, L1 DOOR EVAC SLIDE FELL OUT, DID NOT DEPLOY. RE-INSTALLED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050390Slide · reads lowR1 DOOR EVAC SLIDE LOW PRESSURE IND. REMOVED AND REPLACED R1 DOOR EVAC SLIDE PER MM.SDR UPS05143871Slide · unserviceableESCAPE SLIDE PRESSURE NEEDLE SHOWS IN RED RANGE, DEFERRED M296868. REMOVED AND REPLACED ESCAPE SLIDE PER A300 CH MM 25-61-21-4 M296868 CLEARED, PLACARD REMOVED.SDR SWAA050376Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA050385Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L1 AND R1 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED L1 AND R1 DOOR EVAC SLIDES PER MM.SDR VW3R20050004Girt Bar · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR VW3R20050003Girt Bar · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR SWAA050373Slide · dislodgedR2 DOOR EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED R2 DOOR EVAC SLIDE PER MM.SDR SWAA050339Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050336Slide · dislodgedR1 DOOR EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED R1 DOOR EVAC SLIDE PER MM.SDR AMTA200500151Track · dirtyGIRT BAR LGT EXITING. W/EVAC SLIDE ARMING LEVER IN ARMED POSITION AT SERVICE DOOR R1. FOUND DEBRIS IN GIRT BAR TRACK. REMOVED DEBRIS AND INSPECTED FOR DAMAGE. NO DEFECTS NOTED AND OPS CHECK OK. (K)SDR WRLA2005007Slide · malfunctionedITEM: DURING "C4" CHECK IN TPE R1 SLIDE DEPLOY TEST FAILED, THE SLIDE FELL INSIDE THE GALLEY AREA, AND NOT OUTSIDE THE AIRCRAFT AS IT SUPPOSED TO.SDR AWXA200500221Container · delaminatedSAL - EES - DURING BC-4 CHECK THE EXTERIOR SURFACE OF THE RT OVERWING SLIDE STOWAGE CONTAINER WAS FOUND DELAMINATED AT THE FORWARD LOWER CORNER. MAINTENANCE REMOVED AND REPLACED THE RT OVERWING SLIDE ASSEMBLY IAW T/C C1A25301.SDR SA05015Lanyard · looseCLT - PRIOR TO DEPARTURE, THE CABIN CREW COULD NOT GET ESCAPE SLIDE TO ARM AT DOOR 2R. MAINTENANCE SECURED A LOOSE LANYARD ON SLIDE AT 2R DOOR. SLIDE ARMING OPERATIONALLY CHECKS OK.SDR SB05023Bracket · out of adjustCLT - THE L1 DOOR GIRT BAR WOULD NOT STAY ATTACHED. MAINTENANCE ADJUSTED THE GIRT BAR ATTACH BRACKETS.SDR SWAA050324Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND R1, R2, L1 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED R1, R2, L1 SLIDES PER MM.SDR SWAA050316Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050303Bottle · lowL1 DOOR EVAC SLIDE INDICATION, LOW PRESSURE. REMOVED AND REPLACED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050302Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050279Slide · out of adjustL1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050289Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR SWAA050264Slide · out of adjustL1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050271Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. REMOVED AND REPLACED R1 DOOR EVAC SLIDE PER MM.SDR BB05004Girt Bar · unserviceablePHL - FOUND L2 GIRT BAR IN NEED OF REPLACEMENT. REPLACED L2 DOOR GIRT BAR.SDR UPS05143831Slide · inoperativeFWD ENTRY DOOR SLIDE ARM (ESCAPE SLIDE) WILL NOT TEST PROPERLY. AURAL WARNING BUT NO LIGHT. RESEATED AUTONOMOUS STANDBY PWR SUPPLY UNIT PER A300 AMB 3-52-05-004 AND AMM 52-73-18-4, OPS CK OK.SDR 2005UALA00100Aspirator · leakingLEAKING ASPIRATOR. REPLACED ASPIRATOR.SDR SWAA050253Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050244Slide · out of adjustR2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L2 DOOR EVAC SLIDE PER MM.SDR SWAA050243Slide · out of adjustL2 AND R2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED L2 AND R2 DOOR EVAC SLIDES PER MM.SDR VW3R20050002Gauge · stuckAFTER OVERHAULING THE PRESSURE REGULATOR USED ON THE EVACUATION SLIDE INFLATION SYSTEM, DURING THE CHARGING PROCESS THE GAUGE STAYED AT 3000 PSI AFTER THE PRESSURE WAS RELEASED. THE GAUGE WAS REMOVED FROM SERVICE.SDR VW3R200500001Gauge · stuckAFTER OVERHAULING THE PRESSURE REGULATOR USED ON THE EVACUATION SLIDE INFLATION SYSTEM, DURING THE CHARGING PROCESS THE GAUGE ON THE PUMP WAS SHOWING PRESSURE BUT THE SUSPECT GAUGE WAS NOT RECORDING ANY PRESSURE (THE NEEDLE STAYED AT ZERO). THE GAUGE WAS REMOVSDR UIEA200500004Slide · failedUPPER DECK EMERGENCY ESCAPE SLIDE DID NOT PROPERLY DEPLOY WHEN ACTIVATED. (EA15200503933)SDR SWAA050211Slide · deployedL1 DOOR EVAC SLIDE INADVERTENTLY DEPLOYED. REMOVED AND REPLACED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050191Slide · out of adjustL1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR EVAC SLIDE PER MM.SDR MWEA050017Slide · hung upGIRT BAR FLAP HANGING UP AT FORWARD GALLEY SERVICE DOOR. REMOVED AND REPLACED FORWARD SERVICE DOOR EVACUATION ASSEMBLY.SDR SWAA050173Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050172Slide · out of limitsDURING SCHEDULED SERVICE CHECK, FOUND L2 DOOR EVAC SLIDE IND OUT OF LIMITS. REMOVED AND REPLACED L2 DOOR EVAC SLIDE PER MM.SDR SWAA050166Slide · dislodgedR2 DOOR EVAC SLIDE FELL, OUT DID NOT DEPLOY. REINSTALLED R2 DOOR EVAC SLIDE PER MM.SDR 2005UALA00091Slide · failedSLIDE SUFFERED DAMAGE DURING DEPLOYMENT TO INFLATABLE, ABRASIONS ON EXPOSED HOSES AND 3 HOSES FAILED HYDRO TESTING. LEAKING AT THE WELDED AREA ON TUBING. SLIDE DAMAGED DUE TO IMPROPER HANDING AFTER DEPLOYMENT. REPAIRED INFLATABLE HOLES AND REPLACED HOSES.SDR 2005UALA00086O-Ring · leakingDOOR 1 RIGHT SLIDE LOW BOTTLE PRESSURE. SUPPLEMENTAL DATA UPDATE FILLER VALVE O-RING LEAKING. REPLACED O-RING.SDR 2005UALA00085Plate · distortedBOTTLE WOULD NOT FIRE WHEN THE FIRING CABLE WAS PULLED, THEREFORE THE SLIDE WOULD NOT INFLATE. SUPPLEMENTAL DATA UPDATE RESERVOIR VALVE ASSEMBLY COVER PLATE WAS PUSHED IN CAUSING PULLEY TO NOT ROTATE. REPLACED COVER PLATE AND PULLEY ASSEMBLY.SDR SWAA050163Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.SDR YENA200513Cable · shearedON C2 CHECK, ON ACCOMPLISHING JOB CARD 522100-02-1 FOUND CABLE FOR RT OVERWING SLIDE BOTTLE BROKEN AT THE BOTTLE CONNECTION, ON THE BOTTLE SIDE NOT ON THE AIRCRAFT SIDE. REMOVED AND REPLACED RT BOTTLE ASSEMBLY.SDR SWAA050150Slide · out of adjustDURING SCHEDULED C3 CHECK, FOUND L2 AND R2 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED BOTH L2 AND R2 DOOR EVAC SLIDES PER MM.SDR SWAA050149Slide · out of adjustDURING SCHEDULED C4 CHECK, FOUND R1 AND L1 DOOR EVAC SLIDES OUT OF ADJUST. ADJUSTED BOTH R1 AND L1 DOOR EVAC SLIDES PER MM.SDR SWAA050146Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE PER MM.
Back to JASC 2565