Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2565' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR SWAA050698Slide · dislodgedR1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF HOUSING. SLIDE DID NOT DEPLOY. REINSTALLED R1 DOOR SLIDE PER MM.SDR SWAA050711Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE INADVERTENTLY FELL OUT OF HOUSING. SLIDE DID NOT DEPLOY. REINSTALLED L1 DOOR SLIDE PER MM.SDR SWAA050682Slide · unserviceableDURING SCHEDULED SERVICE CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED L1 DOOR SLIDE PER MM.SDR SWAA050673Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR SLIDE PER MM.SDR SWAA050674Slide · out of adjustDURING SCHEDULED C2 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED L1 DOOR SLIDE PER MM.SDR SWAA050665Slide · dislodgedL1 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED L1 DOOR SLIDE PER MM.SDR SWAA050664Slide · dislodgedL2 DOOR EMERGENCY EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED L2 DOOR SLIDE PER MM.SDR SWAA050663Bottle · dischargedR2 DOOR EMERGENCY EVAC SLIDE PRESSURE INDICATING LOW. REMOVED AND REPLACED R2 DOOR SLIDE PER MM.SDR 2005UALA00208O-Ring · leakingESCAPE SLIDE BOTTLE HAS LOW PRESSURE. FILLER VALVE O-RING WAS LEAKING. FILLER VALVE O-RING WAS REPLACED.SDR UPS05144023Connector · inoperativeMAIN CABIN ENTRY DOOR, SLIDE ARMED WARNING LIGHT FAILS TO ILLUMINATE WHEN TEST SWITCH DEPRESSED. WARNING HORN OK. DEFERRED PER MEL 52-73-01-1 CNTL M298193. PLACARD INSTALLED. *S/D* RESEATED CONNECTOR ON ASPSU. OPS CHECKS NORMAL PER MM 52-73-00-5. THIS CLSDR SWAA050651Latch · out of adjustDURING SCHEDULED C3 CHECK, FOUND L1 DOOR EMERGENCY EVAC SLIDE, CABLE LATCH ASSY OUT OF ADJUST. ADJUSTED L1 DOOR EMERGENCY EVAC SLIDE LATCH ASSY PER MM.SDR 0500303243Cable · brokenDURING LIGHT CHECK, FOUND RIGHT OVERWING SLIDE RELEASE CABLE BROKEN BETWEEN COUPLING AND SLIDE INFLATION BOTTLE. REPLACED SLIDE INFLATION BOTTLE ASSEMBLY WITH CABLE PER AMM.SDR SWAA050645Slide · out of adjustDURING SCHEDULED C1 CHECK, FOUND R1 DOOR EMERGENCY EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR SLIDE PER MM.SDR SWAA050633Bracket · looseL1 DOOR EMERGENCY EVAC SLIDE GIRT BAR BRACKET LOOSE. SECURED BRACKET PER MM.SDR SWAA050611Hook · looseDURING SCHEDULED RON CHECK, FOUND L1 DOOR EMERGENGY EVAC SLIDE GIRT BAR HOOK LOOSE. SECURED GIRT BAR HOOK PER MM.SDR CALA0500065Bottle · dischargedTHE L-4 DOOR ASSIST BOTTLE WAS FOUND TO HAVE ZERO PRESSURE. THE BOTTLE WAS REMOVED AND REPLACED IAW MM 52-11-30.SDR 2005UALA00196Girt Bar · malfunctionedDOOR 2 RIGHT GIRT BAR WILL NOT ENGAGE WITH THE ARM SWITCH, WILL ENGAGE BY MAINTENANCE ONLY. CAUSE IS NOT FULLY KNOWN AT THIS TIME. MAY BE CAUSED BY IMPROPER HANDLING OF SLIDE DURING INSTALLATION WHICH RESULTED IN SLIDE PACK BECOMING UNRAVELED AND INTERFERRSDR SWAA050583Latch · out of adjustR1 DOOR EVAC SLIDE GIRT BAR LATCH OUT OF ADJUST. ADJUSTED R1 DOOR EVAC SLIDE GIRT BAR LATCH PER MM.SDR SWAA050582Slide · out of adjustDURING SCHEDULED RON CHECK, FOUND L1 DOOR EVAC SLIDE OUT OF ADJUST. REINSTALLED L1 DOOR EVAC SLIDE PER MM.SDR BB05012Attach Bracket · looseTPA - IN-FLIGHT, THE GIRT BAR ENGAGEMENT LIGHT EXTINGUISHED AT THE R1 DOOR. MAINTENANCE SECURED A LOOSE GIRT BAR ATTACH BRACKET.SDR 2005UALA00194O-Ring · defectiveLOW BOTTLE PRESSURE IN ONE CYLINDER. REPLACED DEFECTIVE O-RING IN REGULATOR.SDR SWAA050577Slide · out of adjustDURING SCHEDULED HC1 CHECK, FOUND R1 DOOR EVAC SLIDE OUT OF ADJUST. REINSTALLED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050566Slide · dischargedL2 DOOR EVAC SLIDE PRESSURE INDICATION LOW. REMOVED AND REPLACED L2 DOOR EVAC SLIDE PER MM.SDR DLM88050130Slide · deployedTAIL CONE WAS ACCIDENTALLY DEPLOYED AT THE GATE, SLIDE DID NOT DEPLOY. REPLACED DEPLOYMENT LANYARD AND REINSTALLED TAIL CONE.SDR 2005UALA00176Disc · rupturedLOW BOTTLE PRESSURE. RUPTURE DISC LEAKING. REPLACED RUPTURE DISC.SDR SWAA050563Fitting · crackedDURING SCHEDULED SPECIAL VISIT, FOUND R1 DOOR ESCAPE SLIDE GIRT BAR, AFT FLOOR FITTING CRACKED. REMOVED AND REPLACED R1 DOOR ESCAPE SLIDE FLOOR FITTING PER MM.SDR SWAA050561Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND L2 DOOR EVAC SLIDE OUT OF ADJUST. REINSTALLED L2 DOOR SLIDE PER MM.SDR SWAA050557Slide · dislodgedL1 DOOR EVAC SLIDE FELL OUT OF CONTAINER. REINSTALLED L1 DOOR EVAC SLIDE PER MM.SDR SWAA050553Fitting · corrodedDURING SCHEDULED 1/2D CHECK, FOUND CORROSION ON L1 DOOR EVAC SLIDE, AFT GIRT BAR FITTING AT BS 344. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR 05019Slide · failedDURING D-CHECK, TASK CARD 7DT2004 UPPER DECK EMERGENCY EVACUATION SLIDE FAILED ON DEPLOYMENT. REMOVED AND REPLACED UPPER DECK EMERGENCY EVACUATION SLIDE IAW B747 MM 25-68-02. REMOVED AND REPLACED BOTTLE IAW B747 MM 25-68-01.SDR UPS05144003Slide · inoperativeINSPECTION TYPE:N/A SLIDE ON MAIN ENTRY DOOR WILL NOT ARM. OPERATED DOOR ARM NORMALLY. OK FOR SERVICE, COULD NOT DUPLICATE PROBLEM.SDR SWAA050519Slide · out of adjustR1 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R1 DOOR SLIDE PER MM.SDR SWAA050506Slide · dislodgedR1 DOOR EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED R1 DOOR EVAC SLIDE PER MM.SDR SWAA050501Slide · unserviceableDURING SCHEDULED PM CHECK, FOUND L1 DOOR EVAC SLIDE PRESSURE IND OUT OF LIMITS. REMOVED AND REPLACED L1 DOOR EVAC SLIDE PER MM.SDR UPS05143915Slide · inoperativeCREW ENTRY DOOR DOES NOT INDICATE "SLIDE ARMED" ON ECAM DOOR PAGE AFTER ARMING DOOR LEVER. DEFERRED PER MEL 52-30-04. PERFORMED TEST OF ENTRY DOOR LIMIT SW. IAW 52-73-13-5. SYSTEM OPS CK GOOD SEVERAL TIMES. NO HISTORY NOTED A/C OK TO CONTINUE THIS CLEARS M29SDR AALA20050127Bottle · dischargedLAS - NR 3 RIGHT DOOR SLIDE BOTTLE PRESSURE BELOW GREEN BAND AND OUT OF LIMITS. EXPIRATION ON SLIDE IS 09/01/2005. SLIDE DID NOT DEPLOY ON TEST. REPLACED SLIDE ON NUMBER THREE RIGHT HAND DOOR SLIDE. SYSTEM GROUND CHECKED NORMAL OPERATION.SDR ABXA050029Girt Bar · failedLT FORWARD ENTRY DOOR GIRT BAR FAILED TO LOCK. PLACED MED EMERGENCY ESCAPE SLIDE ON DEFERRAL AND MAINTENANCE PROCEDURES COMPLIED WITH. CLEARED DEFERRAL. FOUND SEAL ON LOWER FORWARD BUSTLE BINDING. TRIMMED SEAL ON BUSTLE AND EMERGENCY SLIDE ARMS NORMAL IAW BSDR SWAA050464Fitting · corrodedDURING SCHEDULED D-CHECK, FOUND GIRT BAR FITTING AT BS 344, LBL 59, CORRODED. REMOVED AND REPLACED GIRT BAR FITTING PER SRM.SDR 2005UALA00304Cell · separatedAFTER INFLATION AND PRESSURIZING TO 2.5 PSI FOR AR, CHAMBERS SEPARATED. ADHESIVE FAILURE, RESULTED IN AIR CHAMBERS TO SEPARATE DURING PRESSURIZATION OF ASSEMBLY. UNIT WAS SENT TO OEM FOR REPAIR/DISPOSITION.SDR ASAA04801AALanyard · disconnectedSEA - PREFLIGHT CHECK, FORWARD PAX L1 DOOR EMERGENCY SLIDE LANYARD WAS FOUND DISCONNECTED. RECONNECTED LANYARD. (M)SDR SWAA050439Slide · out of adjustDURING SCHEDULED HC2 CHECK, FOUND R2 DOOR EVAC SLIDE OUT OF ADJUST. ADJUSTED R2 DOOR EVAC SLIDE PER MM.SDR SWAA050418Slide · dislodgedR2 DOOR EVAC SLIDE FELL OUT, DID NOT DEPLOY. REINSTALLED R2 DOOR EVAC SLIDE PER MM.SDR AWXA200500208Bar · bindingPHX - EES - DURING 4-DAY CHECK THE L-2 EMERGENCY SLIDE GIRT BAR FAILED RETRACTION TEST. MAINTENANCE REMOVED AND REPLACED L-2 EMERGENCY SLIDE GIRT BAR IAW T/C R1C25304, FUNCTIONAL TEST WAS GOOD.SDR SWAA050410Hook · damagedR1 DOOR EVAC SLIDE GIRT BAR FWD HOOK HAS SHEARED RIVET. REMOVED AND REPLACED RIVET PER MM.SDR P9RA20050068Proximity Sensor · dirtyCANCUN - AFTER LANDING, FLIGHT ATTENDANT NOTICED R1 DOOR SLIDE LIGHT WAS NOT ILLUMINATED. ITEM DEFERRED PER MEL 25-66-5. INSPECTED, CLEANED GIRT BAR PROXIMITY SWITCHES. OPS CHECKED GOOD. CLEARED MEL 25-66-5.SDR VW3R20050010Girt Bar · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR VW3R20050009Extension · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR VW3R20050008Extension · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR VW3R20050007Extension · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.SDR VW3R20050006Girt Bar · defectiveGIRT EXTENSION DOES NOT FIT PROPERLY ON GIRT BAR. GIRT EXTENSION PADS RIDE UP ON CAVITY RIDGE OF GIRT BAR. PLEASE NOTE THIS EVACUATION SLIDE IS ALSO USED ON A310 AIRCRAFT.
Back to JASC 2565