SDR DALA2024102810476Bottle · dischargedSHIP 3315 ENG 1 FWD FIRE BOTTLE REQUIRES REPLACEMENT DUE TO ENGINE FAILURE. CORRECTIVE ACTION: ENGINE WAS REPLACED AND FIRE BOTTLES WERE REPLACED. OK FOR SERVICE. (9999624)SDR R61A2024102800100Valve · failedENGINE FIRE EXTINGISHING SYSTEM 2 WAY TEE VALVE AT FIRE BOTTLES FAIILED FUNCTION TEST.SDR AALA202410077356Warning Light · illuminatedAIRCRAFT WAS NOT GROUNDED: APU FIRE EXTINGUISHER DISCHARGE LIGHT COMING ON INTERMITTENTLY IN CRUISE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR YENA2024092501303Fire Bottle · faultedFLT#1189, JFK-SAN. ' AT CRUISE ECAM SMOKE FWD CARGO SMOKE , SMOKE FWD BOTTLE 1 FAULT , SMOKE AFT BOTTLE 1 FAULT . ( FWD/AFT/BULK CARGO COMPT EXT AGENT BOTTLE 1 - BOTH CARGOS EMPTY ); REMOVED AND REPLACED CARGO FIRE BOTTLE (4005WX) IAW AMM 26-23-41. OPS CHECK GSDR CALA2024091700645Extinguisher · missingDURING DETAILED INSPECTION OF LAVATORY "M", OBSERVED MISSING OF FIRE EXTINGUISHER BOTTLE OF WASTE COMPARTMENT. CONDUCTED A DETAIL INSPECTION INSIDE WASTE CHUTE ASSY, REMOVED PAINEL ACCEESS BUT NOT FOUND THE AUTOMATIC EXTINGUISHER FIRE BOTTLE INSIDE THE COMPARSDR QXEA2024081900190Smoke Detector · malfunctionedAFT FIRE BOTTLE ARMED LIGHT ILLUMINATED AND EICAS DISPLAYED"CRG AFT FIREX HI ARM". REMOVED FROM SERVICE AND FERRIED FOR REPAIRS. REPLACED AFT CARGO COMPARTMENT SMOKE(AFT) DETECTOR, PERFORMED OPERATIONAL TEST PER E175 MM TASKS 26-15-01-000-801-A & 26-15-01-400-SDR CALA2024072900297Fire Bottle · expiredCHECK (VISUAL) CARGO COMPARTMENT FIRE BOTTLE DISCHARGE SQUIB EXPIRATION DATE TAG FOR EXPIRATION DATE. {MULT-26-3-0021} - INBORD SQUIB PLACARD INDICATES EXPIRATION 2023 PARTS NEEDED MF PARTS# 446616 CORRECTION IPC 26-23-01-22A ITEM 20 REMOVE THE LINING AT THE ASDR DALA2024071207048Fire Bottle · dischargedSHIP 3273 DISC: ENG 2 FIRE PB SELECTED AGENT 1 BOTTLE DISCHARGED. C/A: REMOVED#2 ENG #1 BOTTLE IAW A320 AMM 26-21. INSTALLED #2 ENG #1 BOTTLE UP UNTIL STEP A320 AMM 26-21-41-400-001-A STEP 4.(H).(N BRIGHT 038228) C/W REMAINING STEPS OF A320 AMM 26-21. OPS CK GSDR AALA202407051973Indicator · false activationAIRCRAFT WAS NOT GROUNDED: FLIGHT CREW REPORTED AN ENGINE # 2, AGENT 1 DISCHARGE LIGHT ILLUMINATED INFLIGHT. MAINTENANCE FOUND NO INDICATION OF FIRE BOTTLE DISCHARGE OR FAULT ON ENGINE AND APU FIRE PANEL. MAINTENANCE ACCOMPLISHED A SATISFACTORY OPERATIONAL CHESDR UIEA2024070300572Fire Bottle · leakingFIRE BOTTLE LEAKED(<P>REMOVED AND REPLACED FIRE BOTTLE IAW EO 6725A252. OK FOR SERVICE</P>)SDR AALA202406241153Pressure Switch · damagedAIRCRAFT WAS GROUNDED: FLIGHT CREW REPORTED THAT AT CRUISE, NOTICED THAT ON THE OVERHEAD PANEL, ENGINE 1 FIRE AGENT 2 INDICATES DISCHARGE. MAINTENANCE FOUND PRESSURE SWITCH THREADS ON THE FIRE BOTTLE DAMAGED PREVENTING THE CANNON PLUG FROM MAKING FULL CONTACT SDR AALA202406050492Warning Light · illuminatedAIRCRAFT WAS NOT GROUNDED: ENROUTE AFTER ABOUT 2 HOURS INTO FIGHT, THE APU AGENT DISCHARGE LIGHT CAME ON THE OVERHEAD WITH NO MANIPULATION ON PILOTS PART FOR A FEW MINUTES THEN WENT OFF. NO OTHER INDICATIONS. MAINTENANCE PERFORMED A SATISFACTORY OPERATIONAL CSDR AALA202406042695Indicator · false activationAIRCRAFT WAS NOT GROUNDED: APU FIRE DISCHARGE LIGHT ILLUMINATED PRIOR TO TOUCHDOWN FOR A SHORT PERIOD AND WENT AWAY. MAINTENANCE REPORTED THAT THE APU FIRE TEST FUNCTIONS NORMALLY AND THE APU FIRE DISCK WAS PRESENT. NO DEFECTS WERE NOTED BY MAINTENANCE.SDR YENA2024041600611Fire Bottle · failed inspDURING HEAVY MAINTENANCE: FWD CARGO FWD FIRE BOTTLE SN# 48673F1 FAILED WEIGHT CHECK; REF STS WO W003329 NR W003329 N0356 REMOVED AND REPLACED FWD CARGO FIRE BOTTLE IAW A321 AMM 26-23-41-400-004-B.SDR AALA202403116764Extinguisher · dischargedAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED DUE TO: FIRE EXTINGUISHER DISCHARGED IN THE FLIGHT DECK. ONLY CLEAR GAS EXPELLED; AIRCRAFT DIVERTED TO AND LANDED SAFELY AT BNA. REMOVED AND REPLACED FLIGHT DECK FIRE EXTINGUISHER. PER AMM 26-26-01.SDR DXTA2024030111053Connector · faultedCOCKPIT FIRE SWITCH: L ENG FIRE SWITCH- LIGHT BEHIND SWITCH WOULD ILLUMINATE INTERMITTENTLY WHILE IN CRUISE FLIGHT. ALL ENGINE INDICATIONS SHOWING NORMAL, NOT ACCOMPANIED BY ANY AURAL WARNING. UPON 1ST BATT POWER UP. PERFORMED ENG FIRE TEST & BOTH ENG SWITCHESDR SWIA2024022800007Bottle · warning messageAT NEXT OVERNIGHT MX BASE VISIT TROUBLESHOOT REPEAT CARGO BOTTLE LO CAUTION MESSAGE INFLIGHTMCI TYPE: TROUBLESHOOTING PRIORITY 1 (FLIGHT 3205 FILED CLOSED)FEB 27, 2024 STATION: YUM--UPON ARRIVAL TO AIRCRAFT INTERROGATED MDC AND FOUND B1 008350. TROUBLESHOT PESDR DALA2024020901762Extinguisher · dischargedSHIP 3263 DISC: FWD CARGO FIRE EXTINGUISHER DISCHARGED. C/A: BEGAN RESTORATION OF FES SYS PER A320 AMM 26-23 (889397) REMOVED AND REPLACED FWD CARGO FIRE BOTTLE PER A319-320 AMM 26-16. RFID PENDING (221599) RFID TAGE INSTALLED. MEL/PLAC RMVD. OK FOR SERVICE. (SDR AALA202402122869Fire Bottle · false indicationAIRCRAFT WAS NOT GROUNDED: APU FIRE BOTTLE DISCHARGED LIGHT ILLUMINATED AFTER TAKEOFF. MAINTENANCE REPLACED THE APU FIRE EXTINGUISHING BOTTLE PER AMM 26-22-01.** (CLOSED)SDR AALA202402052869Warning Light · illuminatedAIRCRAFT WAS NOT GROUNDED: APU FIRE BOTTLE DISCHARGED LIGHT ILLUMINATED AFTER TAKEOFF. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR DXTA2024012210667Fire Bottle · low pressureAT ALTITUDE, GOT A FIRE BOTTLE LOW ANNUNCIATOR. CREW RAN QRH & DECLARED AN EMERGENCY. FIRE DEPART CHECKED ACFT & OBSERVED NO EVIDENCE OF FIRE. THERE ISN'T A WAY TO VERIFY WHICH FIRE BOTTLE WOULD HAVE TRIGGERED ANNUNCIATOR. FOUND NO CASS MESSAGE AT ARRIVAL TOSDR UIEA2023122701033Relay · unknownIN THE OPERATIONAL CHECK OF CARGO FIRE EXTINGUISHING BOTTLE RELAYS, THE RELAY K823 FOUND INOPERATIVE.(<P>THE RELAY K823 WAS REPLACED IAW SWPM 20-81-22 REV.84 DATE:15-OCT-23. NO FURTHER DEFECTS NOTED</P>)SDR AALA202312181170Fire Bottle · warning messageAIRCRAFT WAS GROUNDED: ON INITIAL CLIMB OUT ENGINE 1 AGENT 1 "DISCH" LIGHT ILLUMINATED. REPLACED ENGINE 1 FIRE EXTINGUISHER BOTTLE PER AMM 26-21-41.SDR AALA202311281128Fire Bottle · warning messageAIRCRAFT WAS GROUNDED: AN EMERGENCY WAS DECLARED AND THE AIRCRAFT DIVERTED TO BOS DUE TO A BOTTLE 2 DISCHARGE ENGINE EICAS MESSAGE. MAINTENANCE REPLACED THE #2 ENGINE FIRE EXTINGUISHING BOTTLE AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR MASA2023111400139Unknown · unknownR/H ENG 2 FIRE BTL DISCHARGE- REPLACED FIRE BOTTLE AND C/W INSP OF ENG, NO DAMAGESDR AALA202310309230Fire Warning · false indicationAIRCRAFT WAS NOT GROUNDED: ENGINE 1 AGENT 2 DISCHARGE LIGHT ILLUMINATED IN FLIGHT. MAINTENANCE PERFORMED ENGINE #1 FIRE PROTECTION SYSTEM TEST PER AMM 26-12-00 WITH NO DEFECTS NOTED.SDR UIEA2023102800933Unknown · unknownFIRE EXTINGUISHER UNDER SIDE PANEL CANNOT BE PROPERLY SECURED. CLASP WILL NOT STAY LATCHED(<P>ADJUSTED FIRE EXTINGUISHER CLASP IAW AMM B676 AMM 51-40-02. OPS CHECKS GOOD AT THIS TIME. VERIFIED PROPERLY CLOSED IAW AMM 25-60-00</P>)SDR CALA2023092002834Fire Bottle · unknownFOUND SAFETY RELEASE CAP ATTCHED TO ENGINE FIRE BOTTLES REMOVED SAFETY RELEASE CAP FROM BOTH FIRE BOTTLES REF AMM26-21-01. VERIFIED BOTH FIRE BOTTLES SAFTEY RELEASE CAPS HAVE BEEN REMOVED. INSPECTED BOTH FIRE BOTTLES FOR INSTALLATION , SERVICABILITY AND HYDOSTSDR FDEA202309161609Fire Suppression · activatedWHILE STILL AT GATE, PRIOR TO PUSH, FSS DISCHARGE LIGHT ILLUMD. SMELLED ODOR OF SUPPRESSION FOAM. NO ACTUAL FIRE IND. FSS POSITIONS 1L,R,C ARE MEL D ON ACFT. OPENED WINDOWS & DOORS. STAIRS WERE BROUGHT BACK. MX NOTED FOAM DISCHARGED. RELEASED FOR SERVICE PSDR DALA2023091807653Unknown · unknownSHIP 8105 - DIV - TO MKE DUE TO "CARGO BTL FAIL" CAUTION MESSAGE. CORRECTIVE ACTION: CARGO BOTTLE PLACED ON MEL; R/R HRD FIRE BOTTLE. (LP# 4492632)SDR DALA2023082907020Unknown · unknownSHIP 3321 DURING B1 CHECK FOUND CRG DISCH BTL 1 & BTL 2 ILLUMINATED. CORRECTIVE ACTION: REMOVED BOTH LDCC FIRE EXTINGUISHER BTLS. PERFORMED INSTALLATION OF BOTH LDCC FIRE EXT BOTLS PER AMM 26-23. (4617228)SDR AALA202308296349Unknown · unknownAIRCRAFT WAS GROUNDED: MID FLIGHT THE #2 ENGINE FIRE, AGENT 1 DISCHARGE LIGHT ILLUMINATED WITH NO ASSOCIATED ECAM MESSAGE. **SUPPLEMENTAL REPORT WILL BE SUBMITTED** (OPEN)SDR HNAA2023080900304Unknown · unknownAFTER T/O FIRE DET 2 FAIL INDICATED ON EICAS.FACT 09AUG23 21:33 CLT GROUND RAN A/C FOR 5 MIN AND OHM OUT #2 FIRE DETECTOR P 0914 AND FIRE LOOP. NO DEFECTS NOTED. OPS CHECK GOOD OK FOR SERVICE. E2 FIRE DET FAIL WITH ENG 2 ON AND THRUST LEVER ADVANCED. PESDR DALA2023071705768Unknown · unknownSHIP 3319 DURING CHECK OF APU FIRE EXTINGUISHING SYS. FOUND APU FIRE PB SW WOULD NOT LATCH. CORRECTIVE ACTION: R/R APU FIRE PB SW. (4971901)SDR SWAA2023071879074Extinguisher · dischargedAPU BOTTLE DISCHARGE LIGHT ILLUMINATED<[01] T/S PER FIM 26-20 TASK 802. FOUND APU BOTTLE DISCHARGED. R/R APU FIRE EXTINGUISHING BOTTLE IAW AMM 26-21-01. APU BOTTLE DISCHARGE LIGHT REMAIN ILLUMINATED AND APU FIRE BOTTLE EXTINGUISHED. (REFER TO DISCP TTG8Q00M85XSDR AALA202306133621Control Panel · false activationAIRCRAFT WAS GROUNDED: ENGINE 2 AGENT 1 DISHARGE LIGHT CAME ON DURING FLIGHT. MAINTENANCE REPLACED ENGINE / APU FIRE PANEL PER AMM 26-12-12 AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK.SDR AALA202306121506Warning Light · false activationAIRCRAFT WAS NOT GROUNDED: DURING CRUISE WE NOTICED APU AGENT DISCHARGE LIGHT ILLUMINATED. DURING DESCENT THE LIGHT EXTINGUISHED. MAINTENANCE PERFORMED AN OPERATIONAL TEST OF APU FIRE EXTINGUISHING LOOP/SQUIB PER AMM 26-22-00 WITH NO FAULTS NOTED.SDR AALA202306093053Extinguisher · false indicationAIRCRAFT WAS GROUNDED: SEVERAL TIMES DURING FLIGHT ENGINE ONE FIRE AGENT ONE DISCHARGER LIGHT WOULD COME ON FOR SEVERAL MINUTES, FLICKER AND GO OUT. MAINTENANCE REPLACED THE #1 ENGINE FORWARD FIRE EXTINGUISHER BOTTLE PER AMM 26-21-41 AND ACCOMPLISHED A SATISFASDR A6WA202306018622Fire Bottle · unknownCARGO BOTTLE LOW CAUT MSG RCVD WHEN DESCENDING INTO ORD. CW QRH PROCEDURE LANDED WITHOUT FURTHER INCIDENT ******AIRCRAFT REMOVED FROM SERVICE******* REMOVED AND REPLACED LH CARGO FIRE EXT CONTAINER IAW AWA SUP 10-099B OPS CHECK GOOD SDR DALA2023053004336Unknown · unknownSHIP 3403 ENG FIRE TEST FOUND ENG2 AGENT 2 NO SQUIB LIGHT. CORRECTIVE ACTION: RECONNECTED CONNECTOR(4WE2). (4658228)SDR I5EA2023051500004Control Panel · unserviceable1. FIRE DETECTED IN AFT CARGO COMPARTMENT IN CRUISE FLT AT FL400, AS PER QRH DISCHARGED FIRE SUPPRESSION BOTTLE, DIVERTED TO KELP. REMOVED AND REPLACED #1 CARGO FIRE CONTROL PANEL IAW AMM 26-00-00 OPS CHECK GOOD. 2. FIRE DETECTED IN AFT CARGO COMPARTMENTONSDR GTIA2023051137179Fire Bottle · depletedLAV "F" FIREBOTTLE READS 0 PSI. ( LAVATORY WASTE BIN FIRE EXTINGUISHER SYSTEM SMOKE DETECTION SYSTEM OPERATES NORMALLY A320/A321 )-R/R LAV F FIRE BOTTLE IAW AMM 26-25-41. PLACARD REMOVED MOC NOTIFIED. THIS CLEARS DMI 3117480-2. DMI LOG UPDATED.SDR FDEA202303130509Intercostal · crackedMAIN CABIN, FIRE SUPPRESSION SYSTEM HAS A INTERCOASTAL CRACKED P/N VA-FSS-6040. 0000785585 : RODRIGUEZ, RENE P - 27-MAR-2023 19:46 REMOVED FABERCATED AND INSTALLED NEW VA-FSS-6040-1 INTERCOSTAL IAW VERTURA AEROSPACE DWG VA-FSS-6040, SRM 51-33-01-0G AND SRM SDR QXEA2023033100057Unknown · unknownAFT E-BAY SMOKE TUBE GRILL CLOGGED. CLEANED AFT E-BAY SMOKE TUBE GRILL REF. 12-22-01.SDR FDEA202303090512Strap · crackedMAIN CABIN, SUPPRESION SYSTEM STRAP P/N VAFSS-6070-1 IS CRACKED. 0000785585 : RODRIGUEZ, RENE P - 28-MAR-2023 19:08 REMOVED AND INSTALLED NEW VAFSS-6070-1 STRAP IAW SRM 51-31-01-0GSDR FDEA202303090508Unknown · crackedMAIN CABIN, FIRE SUPPRESION SYSTEM HAS A CLIP CRACKED P/N VAFSS 6045-1 0000785585 : RODRIGUEZ, RENE P - 27-MAR-2023 19:34 REMOVED FABERCATED AND INSTALLED NEW VA-FSS-6045-1 CLIP IAW VERTURA AEROSPACE DWG VA-FSS-6045, SRM 51-33-01-0G AND SRM 51-38-01-0G (SEESDR CALA2023021000377Fire Detector · unknownBOTTLE DISCH CARGO EICAS ADVISORY BOTH RAPID DISCHARGE CARGO FIRE EXTINGUISHER BOTTLE PRESSURES AR E LOW. REMOVED AND REPLACED ALL FIRE BOTTLE SQUIBS ON FIRE BOTTLES 1A,1B, 2A, 2B, AND 2C IAW 26-23-02-400-801 LOWER CARGO FIRE BOTTLE SQUIB. PERFORMED ALL TASKS,SDR DALA2023012600654Extinguisher · out of limitsSHIP 3308 OUT LIMIT FIRE EXTINGUISHER BOTTLE WEIGTH (AFT BOTTLE) IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: REMOVED AND REPLACED FIRE EXTINGUISHER BOTTLE (AFT BOTTLE) IN FWD CARGO COMPARTMENT (1 EA). PERORMED OPERATIONAL CHECK OF FIRE EXTINGUISHING BOSDR DALA2023012600652Extinguisher · out of limitsSHIP 3308 OUT LIMIT FIRE EXTINGUISHER BOTTLE WEIGTH (FWD BOTTLE) IN FWD CARGO COMPARTMENT (1 EA). CORRECTIVE ACTION: REMOVED AND REPLACED FIRE EXTINGUISHER BOTTLE (FWD BOTTLE) IN FWD CARGO COMPARTMENT (1 EA). PERORMED OPERATIONAL CHECK OF FIRE EXTINGUISHING BOSDR AALA202301196376Warning Light · false indicationAIRCRAFT WAS NOT GROUNDED: AGENT 2 DISCHARGE ON #2 ENGINE. MAINTENANCE PERFORMED ENGINE 2 FIRE TEST AND DISCHARGE LIGHT EXTINGUISHED.
Back to JASC 2620