JASC 2621
Service difficulty reports · 623
Reports filed under 2621 · Fire Bottle, Fixed, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2621' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR F3LA2017061200179Fire Bottle · defectiveAPU FIRE EXTINGUSHER LIGHT ILLUMINATED. REMOVED AND REPLACED THE APU FIRE BOTTLE & SQUIB IAW AMM 26-22-41 PB 401 & 26-22-42 PB 401. OPS CHECKED GOOD. APU RUN TESTED GOOD IAW AMM 49-00-00-710-010A.SDR AALA201705189017Fire Bottle · leakingDURING CRUISE ALTITUDE. AGENT 2 LOW LIGHT ILLUMINATED. NO INDICATION OF ABNORMAL ENGINE OPERATION NOTED. NO OTHER ASSOCIATED LIGHTS. THE FLIGHT CONTINUED AND LANDED WITHOUT FURTHER INCIDENT. TROUBLESHOOTING FOUND ALL THE SQUIBS UNFIRED. BUT THE BOTTLE WASSDR EBVR20161219001Fire Bottle · dischargedNOTICED ISSUE DURING A DELIVERY INSPECTION AFTER MAINTENANCE WAS COMPLETED. FOUND APU BOTTLE DISCHARGED BY LOOKING AT THE PRESSURE GAUGE IN THE TAILCONE. NO INDICATION IN THE COCKPIT THAT THE BOTTLE WAS DISCHARGED. FIRE BOTTLE SQUIB WAS DISCHARGED. REPLACED FSDR EBVR20161206001Fire Bottle · emptyNOTICED DURING DELIVERY INSPECTION (BEFORE RELEASE FOR FLIGHT AFTER MAINTENANCE) THAT THE APU FIRE BOTTLE WAS EMPTY. NO INDICATION IN THE COCKPIT THAT THE BOTTLE WAS EMPTY. FIRE BOTTLE SQUIB WAS NOT DISCHARGED. REPLACED BOTTLE AND SQUIB. AIRCRAFT RELEASE FSDR VNAA2016071500015Fire Bottle · low pressureCARGO BOTTLE LOW CAUTION MESSAGE. MAINTENANCE INSPECTED, REMOVED AND REPLACE THE RIGHT HAND A3HL CARGO FIRE BOTTLE AND PERFORMED CHECKS IAW THE AMM. THE AIRCRAFT WAS RELEASED FOR SERVICE.SDR UIEA2016032800221Fire Bottle · scratchedFOUND LAVATORY FIRE EXTINGUISHER SCRATCHED AT B545A, DC2, B546A, FC4, 4 EACH. REPLACE LAVATORY FIRE EXTINGUISHER AT B545A, DC2, B546A, FC4, 4 EACH IAW AMM 26-27-01-004-001-002 REV 85 & AMM 26-27-01-404-006-002 REV 85.SDR CALA2016022495132Fire Bottle · dischargedAFT CARGO DET FAULT DISPLAYED ON UPPER ECAM SCREEN, SHOWING AFT CARGO SMOKE DISCHARGE AGENT 2 DISPLAYED. INSPECTION FOUND SECURE. REPLACED FWD CARGO FWD BOTTLE IAW AMM 26-23-00-200-005-A SEE PTT 5002010.SDR SIMA20160125002Fire Bottle · dischargedCARGO EXTINGUISHER BOTTLE DISCHARGED. PERFORMED OPERATIONS CHECK OF BAGGAGE SMOKE DETECTION SYS IAW AMM 26-15-00. OPERATIONS CHECKED GOOD. DEFERRED BAGGAGE FIREX SYS MEL 26-9. R & R CARGO HIGH RATE & METERING BOTTLES IAW AMM 26-23-01. MEL ITEM RESTORED. SDR FDEA201601160167Fire Bottle · faultedCARGO FIRE EXTINGUISHER AGENT LOW LIGHTS ON FOR BOTTLE 1. REASON CODE, REMOVAL FROM ACFT ONLY, NO INSTALLATION. REMOVED LOWER CARGO COMPARTMENT FIRE EXTINGUISHER CONTAINER IAW AMM 26-22-01-4, ALL HARDWARE IS ATTACHED TO THE RACK. REASON CODE, INSTALLATION OSDR 2020FA0000196Fire Bottle · emptyDATA BASE ISSUE RELATING TO FLIGHT PLAN DISPLAY ON MFD MAP AND PFD CDI ALSO "APU FIRE BOTTLE LOW" CAS. APU WOULD NOT START. FOUND APU BOTTLE EMPTY AND NEEDING REPLACEMENT. TEXTRON TECHS REPLACED BOTTLE. CONTINUED TRIP FOLLOWING DAY.SDR CA160211004Extinguisher · unwanted deploy(CAN) CARGO FIRE EXTINGUISHER BOTTLE AUTO DEPLOYED, NOT ENTIRELY SURE OF CAUSE- SUSPECT ACFT BATTERY WAS LT ON THUS POWER DRAINED DOWN TO AN ALMOST DEAD CAPACITY AND FIRE EXTINGUISHER CONTROL BOX SENSED THIS AND AUTO DEPLOYED THE FIRE EXTINGUISHER INTO ACFT CASDR CA150806001Connector · misinstalled(CAN) WHEN THE FIRE BOTTLE WAS REMOVED FOR REPLACEMENT, IT WAS FOUND THAT THE SHORTING SPRING WAS LEFT INSERTED IN THE CONNECTOR WHEN THE BOTTLE WAS INSTALLED. THIS SPRING COULD HAVE PREVENTED THE PROPER FIRING OF THE BOTTLE HAD THE NEED AROSE FOR IT. INSPECTSDR FDEA201507172256Pressure Switch · failedUPON TAXI IN, RECEIVED ENGINE FIRE AGNT LO LEVEL ONE ALERT, ACCOMPANIED BY AN OVERHEAD AGENT 1 LOW LIGHT NR 3 ENGINE. FOUND LOW PRESSURE SWITCH BAD. R & R FIRE EXTINGUISHING CONTAINER IAW & ALL OPERATIONS NORMAL IAW MM 26-21-01,
SDR FDEA201504091180Fire Bottle · unknownNUMBER 3 ENG AGENT 2 LOW LIGHT ON. R & R THE NR 3 ENG NR 2 FIRE BOTTLE.SDR DATA2015040101Fire Bottle · depletedAFTER TAKEOFF, UPON CLIMB OUT THROUGH 4200 FT IT WAS NOTICED THAT LT FIRE FAULT LIGHT ON CWP ILLUMINATED. CREW CONSULTED QRH & RESET CB WHICH HAD POPPED. IT WAS THEN NOTICED THAT BOTH LT ENG FIRE EXTINGUISHER INDICATORS INDICATED DISCHARGED CONDITION, WHITE.SDR FDEA201412104091Fire Bottle · inoperative50MIN INTO FLIGHT GOT NR 2 LOWER AFT FLASHING DISCHARGE. DEPLOYED NR 2 BOTTLE, NR1 DEFERRED, FOLLOWED BY SMOKE RED INDICATION WHICH WENT OUT AFTER SEVERAL MINUTES. FIRE EXTINGUISHER CYLINDER NR 2 INOPERATIVE. ALL LOWER CARGO COMPARTMENTS MUST REMAIN EMPTY.SDR USAA2014112400009Fire Bottle · inoperativeLAVATORY A TRASH BIN FIRE EXTINGUISHER BOTTLE INOPERATIVE. REPLACED FIRE EXTINGUISHER BOTTLE IAW AMM 26-13-10.SDR SWIA201439916Bottle · failedCARGO BOTTLE LOW CAUTION EICAS MESSAGE IN FLIGHT. R & R DISCHARGE BOTTLE. OPS CHECKED GOOD AT THIS TIME IAW AMM.SDR FDEA201410213317Fire Bottle · faultyMULTI-FUNCTION DISPLAY STATUS PAGE SHOWED MSG CGO BOTTLE 2A, 2B & 2C. DURING ACFT POWER UP WIRING CONTINUITY CHECK CARRIED OUT ON CGO FIRE EXTINGUISHING BOTTLE 2A, 2B & 2C SQUIB CIRCUIT & WIRING BETWEEN SIU 2 & MONITOR CARD IAW WDM 26-23-11 & 26-23-51. CGO FSDR FDEA201409052470Warning System · false activationTHE FSS DISCHARGE LIGHT ILLUMINATED WITH NO OTHER INDICATIONS IN THE COCKPIT. THE FSS CONTROL PANEL SHOWED SUPPRESSING FIRE WITH A FAULT ILLUMINATED IN POS 2R. THE FAULT ALSO SHOWED BURST DISK. TEMP WINDOW ALSO SHOWED MANY TEMP VARIATIONS BETWEEN -4 TO 500 SDR SIMA20140903008Tube · chafedLEFT ENG FIRE EXTINGUISHING DISCHARGE TUBE IS CHAFED AT AFT OTBD END OF ENG. REPAIRED THE LT ENG FIRE EXTINGUISHING DISCHARGE TUBE, AT AFT OTBD END OF ENG IAW AMM 20-10-03.SDR UIEA201408072406Warning System · activatedAPU BOTTLE LOW PRESS MSG 26043. APU BOTTLE DISCHARGE LIGHT ON & APU SQUIB WON'T TEST. ITEM DEFERRED IAW DDG 26-22-01.SDR REXA2014072200730Fire Bottle · low pressureLAVATORY FIRE EXTINGUISHER BOTTLE READS IN THE RED. DEFERRED R & R LAVATORY FIRE EXTINGUISHER IAW AMM-26-26-01. THIS CLEARS DM 007206.SDR SWIA201438522Fire Bottle · dischargedCARGO BOTTLE LOW CAUTION MESSAGE DURING FLIGHT. INSPECTED THE CARGO COMPARTMENT FOR SIGNS OF FIRE-SMOKE DAMAGE. NONE FOUND. REPLACED LT CARGO FIRE BOTTLE. OPS CHECKED GOOD.SDR SWIA201438520Fire Bottle · dischargedIN FLIGHT GOT CARGO BOTTLE LOW MESSAGE. RETURNED TO DEPARTURE. R & R LT CARGO BOTTLE.SDR C77A20140701001Fire Bottle · failedINTERMITTENT FIRE BOTTLE ENG 1 & 2 FIRE BOTTLE A FAIL. R & R ENG 1 & 2 FIRE BOTTLE A IAW AMM, OPERATIONS CHECKED GOOD.SDR SWIA201438299Fire Bottle · failedCARGO BOTTLE LOW MESSAGE. REPLACED THE SMALL CARGO FIRE BOTTLE.SDR USAA2014052900012Fire Bottle · failedAPU FIRE EXTINGUISHER BOTTLE FAILED HYDROSTATIC CHECK. REPLACED APU FIRE EXTINGUISHER IAW ROUTINE JOB CARD 26C31026002 & OPERATIONAL CHECK IAW JOB CARD 26C31026003.SDR VNAA2014040300002Fire Bottle · dischargedCREW REPORTED CARGO BOTTLE LOW AMBER MESSAGE. CREW COMPLETED QRH, DIVERTED AND LANDED WITHOUT INCIDENT. MAINTENANCE INSPECTED, R & R RT CARGO FIRE BOTTLE A3HL AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR UIEA2014022800090Fire Bottle · dischargedLOWER DECK NR 2 FIRE EXTINGUISHER BOTTLE SHOWS DISCHARGE. TRANSFERRED TO DMI 46541 MEL 26-23-01-01.SDR A6WA201441163Fire Bottle · faultedCARGO BOTTLE LOW MESSAGE INFLIGHT. APPROXIMATELY LANDING WEIGHT 42,000 LBS, AIR RETURN CLT. R & R LT CARGO BOTTLE IAW SUP 10-099A, A2HL, OPERATIONS GOOD. FOUND LEAK AT 10TH STAGE ISO VLV CLAMP, SECURED IAW AMM 36-11-07. PERFORMED LEAK CHECK IAW SUP 99-015,SDR CALA2014010990111Indication Sys · malfunctionedRT FIRE BOTTLE ON RT ENG SHOWS DISCHARGED ON OVERHEAD PANEL. ACP FIRE TEST NR 2 ENG & LIGHT CLEARED TESTED GOOD. ACP FDU2 TEST IN MCDU & TESTED OK NO MESSAGES.SDR CALA2014010990092Control Panel · faultyENG 4 SQUIB 2 LIGHT DID NOT ILLUMINATE DURING TEST. REPLACED P461 PANEL IAW WDM 26-21-12, OPERATIONS TESTED GOOD.SDR CALA2013122693911Quick Disconnect · wornNR 2 ENG, 1 FIRE EXTINGUISHER BOTTLE QUICK DISCONNECT PIPE HAS WORN GROOVE FROM NUT, NOT BEEN CONNECTED & SAFETIED. ACCOMPLISHED ON C-CHECK WU M0057H.SDR DALA13063786714Fire Bottle · dischargedNR 2 ENGINE FIRE BOTTLE DISCHARGE LIGHT ON P-8 PANEL & NR 2 ENGINE BOTTLE MESSAGE ON EICAS DISPLAY. REMOVED ENGINE FIRE BOTTLE, INSTALLED ENGINE FIRE BOTTLE IAW AMM 26-21-01.SDR SIMA20131017002Extinguisher · malfunctionedDURING START OF DESCENT, RECEIVED A BAGGAGE EXTINGUISHER WARNING. FOLLOWED APPROPRIATE PROCEDURES AND LANDED. R & R BAGGAGE COMPARTMENT FIRE EXTINGUISHER BOTTLES IAW AMM-26-23-01. OPS CHECKED GOOD. R & R THE CARGO AREA SMOKE DETECTOR. PERFORMED ELECTRICALSDR CALA2013101592058Conduit · wornNR 2 ENG PYLON FWD FIRE BOTTLE 2 EA CONDUITS WORN AT CLAMP LOCATIONS ON OTBD SIDE OF PYLON ACCESS HOLE. REPLACE CONDUIT OF FWD BOTTLE CONNECTOR 5WE2 REF WDM 26-21-03-001.SDR CALA2013100791781Circuit Breaker · damagedCIRCUIT BREAKER AT HOT BATTERY BUS DC BATTERY BUS LOC H1 MISSING HALF OF CIRCUIT BREAKER. REPLACED LT ENG BTL1 CIRCUIT BREAKER IAW WDM 26-21-11 & SQUIB TESTED GOOD.SDR USAA2013072300008Fire Bottle · emptyAFT LT LAVATORY TRASH BIN FIRE EXTINGUISHER GAUGE READS EMPTY. R & R EXTINGUISHER IAW AMM 26-25-41.SDR UALA2013071104826Extinguisher · low pressureFWD AFT LAVATORY FIRE EXTINGUISHER BOTTLE LOW IN THE RED BAND.SDR UALA2013070904777Warning Light · false activationNR 1 ENGINE FIRE DISCHARGE LIGHT ON. NO OTHER INDICATIONS. . VERIFIED BOTTLE PROPERLY CHARGED AND BOTTLE 2 DISCHARGE LIGHT IS WORKING PROPERLY.SDR SWIA201333828Bottle · low pressureRECEIVED A CARGO BOTTLE LOW CAUTION MESSAGE. FLT#2976 REPLACED SMALL CARGO BOTTLE IAW AMM. PN: 36500018-3, SN: 51708D1, SN OFF: 46535D, PN: 30903870, SN: 07303, SN OFF: 05972, PN: 30903870, SN: 07388, SN OFF: 05978SDR UALA2013062604454Extinguisher · dischargedENGINE FIRE EXTINGUISHER DISCHARGED LIGHT OF "AGENT 1" ILLUMINATED WITHOUT FIRING BOTTLE 1. R & R NR 1 ENGINE FIRE EXTINGUISHING BOTTLE IAW MM.SDR REXA2013061701190Warning Message · illuminatedPERFORMED AN AIR RETURN DUE TO CARGO BOTTLE LOW MESSAGE. EMERGENCY WAS NOT DECLARED. OPENSDR CA130708007Fire Bottle · discharged(CAN) AFTER TAKEOFF, CREW RECEIVED A CARGO BOTTLE, LOW CAUTION MESSAGE. ACFT RETURNED TO THE FIELD. CREW REPORTS THAT THEY DID NOT DISCHARGE THE BOTTLE AND RECEIVED NO OTHER COCKPIT INDICATIONS. F/A AND PASSENGERS REPORTED THEY DID NOT SMELL SMOKE OR NOTICSDR UIEA2013061100324Fire Bottle · inoperativeCARGO FIRE BOTTLE ONE LIGHT ILLUMINATED DURING CRUISE, EICAS DISPLAYED. R & R NR 1 CARGO FIRE BOTTLE IAW AMM 26-33-02-40-131, TESTED IAW 26-23-00 ALL PASSED OK FOR SERVICE.SDR REXA2013052901031Fire Bottle · no testNR 2 CARGO FIRE BOTTLE WILL NOT TEST WARNING.SDR QXEA2013050600915Fire Bottle · low pressureMASTER CAUTION. CHECKED FIRE DETECTOR, APU BOTTLE LOW. EXTINGUISHED MASTER WARNING AND COMPLETED CHECKLIST. BECAME INTERMITTENT WITH MASTER WARNING AND CHIMES SOUNDING UNTIL TOUCHDOWN. ON TOUCHDOWN MASTER WARNING, CHIMES, AND APU BOTTLE LOW LIGHTS EXTINGUISDR UIEA2013041400215Fire Bottle · dischargedENGINE DISCHARGE FAULT LIGHTS ARE ON. R & R ENGINES NR 1 AND NR 2 FIRE BOTTLES. OPS CHECKED NORMAL.SDR UALA2013032801999Fire Bottle · low pressureFORWARD AFT LAV FIRE EXTINGUISHER PRESSURE IS LOW. REPLACED FIRE EXT BOTTLE REF AMM 26-25-400-001-A.
Back to JASC 2621