JASC 2700
Service difficulty reports · 1,745
Reports filed under 2700 · Flight Control System, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2700' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '2700' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR GTIA2021101836053None · noneF/CTL SPOILER FAULT AND SPOILER 5 RIGHT SIDE PARTIALLY DEPLOYED IN FLIGHT-INSP FOUND RH SPOILER 5 IMPROPERLY DEACTIVATED PER MEL 27-64-01-7. CANNON PLUG NOT DISCONNECTED & SPOILER KEY STILL INSTALLED AND IN THE "MX" POSITION. RECOMPLIED WITH MEL PROCEDURE PER SDR DALA2021101106210None · noneSHIP 3137 - ABORTED TAKEOFF GREATER THAN 10 KNOTS DUE TO ELAC 2 PITCH FAULT. CORRECTIVE ACTION: PERFORMED GROUND SCAN OF ELAC 2 PER A319 TSM 27-96-00. NO FAULT FOUND. A/C RETURNED TO SERVICE. (7973612)SDR CALA2021100601801Screw · missingPDA 3 ONE SCREW MISSING FROM CANON. REF LP 7173244. REPLACED MISSING SCREW.SDR JJBA20211004003None · noneSUPPLEMENTAL INFORMATION: IN PREPARATION FOR OCF, PILOT FELT RATCHETING IN AILERON CONTROL. FLIGHT NEVER OCCURRED. DURING TROUBLESHOOTING, MECHANIC CYCLED THE SYSTEM AND HEARD A POP. INVESTIGATED AND FOUND CABLE HAD COME APART. MISROUTING AROUND CABLE GUARD SUSDR AALA202110051902Computer · false indicationAIRCRAFT WAS NOT GROUNDED: ON TAKEOFF ROLL BELOW 40 KNOTS, ECAM FLIGHT CONTROL, ELEVATOR AILERON COMPUTER 2, PITCH FAULT MESSAGE. ABORTED TAKEOFF, RETURNED TO GATE. MAINTENANCE ACCOMPLISHED BITE TEST OF THE ELECTRONIC FLIGHT CONTROL SYSTEM PER AMM 27-96-00. NOSDR UIEA2021092302088Elevator · delaminatedL/H I/B ELEVATOR T/E FOUND DELAMINATION(<P>CARRIED OUT REPAIR AS PER SRM 51-70-07 PAR. 5G</P>)SDR UIEA2021092302089Flap · delaminatedRHW I/B AFT FLAP FOUND DELAMINATION. CARRIED OUT REPAIR AS PER SRM 51-70-07 PAR.5ASDR YENA2021100400643Computer · failedFLT # 316, TPA-LGA (DIVERTED TO JFK). SEC 1 FAULT ; R&R SEC 1 PER AMM 27-94-34 OPS CHECK GOOD A/C RETURNED TO SVC MCC NOTIFIEDSDR SWIA202162851None · seizedSYSTEM #1 RUDDER PCU BRAKET BOLT IS SEIZED. (C-CHECK RO 11-24-21) REMOVED SYSTEM #1 RUDDER PCU BRACKET BOLT REF CRJ-700 SRM 51-41-02-001-001-A01SDR AALA202110048242Transducer · noneAIRCRAFT WAS GROUNDED: NUMEROUS MASTER WARNINGS WITH NO ECAM MESSAGE. REPLACED TRANSDUCER SPEED BRAKE CONTROL AND ACCOMPLISHED A SATISFACTORY OPERATIONAL CHECK PER AMM 27-92-14-000-01A AND TSM 27-94-00-810-811A.SDR CALA2021100101748None · noneREGARDING AIR RETURN TO TLV, AHM SHOWING SLATS DRIVE EICAS CAUTION MAINT MESSAGE 27-22452 INBOARD SIDE OF SLAT 6 HAS A SLAT SKEW CONDITION.SDR ABXA2021929096Power Supply · faultySPEED BRAKES EXT EICAS MESSAGE DISPLAYED WITH SPEED BRAKES STOWED SPEED BRAKES LIGHT ILLUMINATED. AIRCRAFT BACK TO BLOCK AND GROUNDED BY MAINTENANCE. MAINTENANCE REMOVED AND REPLACED 2L CSEU P/S B767 AMM 27-09-00. AIRCRAFT RETURNED TO SERVICE.SDR SWIA202162161None · corrodedRH AILERON FLUTTER DAMPER LINK ASSY CORRODED/SIEZED. (C-CHECK RO 10/30/2021) REMOVED OLD AND INSTALLED NEW RH AILERON FLUTTER SHEAR LINK WITH NEW HARDWARE - REF CRJ700 AMM 27-15-05-400-802 A01.SDR SWIA202162306None · failedFUNCTIONAL TEST OF THE RIGHT ELEVATOR POWER-CONTROL UNIT (PCU#2 ) COMPENSATORS FAILED (C-CHECK RO 11/04/2021) REMOVED AND REPLACED THE RH ELEVATOR #2 POWER CONTROL UNIT REF CRJ-900 AMM 27-33-01-000-801-A01 & 27-33-01-400-801-A01,OPERATIONAL TEST GOOD. COMSDR SWIA202162305None · failedFUNCTIONAL TEST OF THE LEFT ELEVATOR POWER-CONTROL UNIT (PCU#2 ) COMPENSATORS FAILED (C-CHECK RO 11/04/2021) REMOVED AND REPLACED THE LH ELEVATOR #2 POWER CONTROL UNIT REF CRJ-900 AMM 27-33-01-000-801-A01 & 27-33-01-400-801-A01,OPERATIONAL TEST GOOD. COMSDR SWIA202162540None · failedREMOVE AND INSTALL NEW SERVICEABLE LH AND RH AILERON FLUTTER DAMPERS (C-CHECK RO 11/10/2021) REMOVED LH AND RH AILERON FLUTTER DAMPER PER CRJ700 AMM 27-15-05-000-801-A01 AND INSTALLED NEW SERVICEABLE LH AND RH AILERON FLUTTER DAMPER PER CRJ700 AMM 27-15-0SDR SWIA202162128None · failed# 2 RUDDER PCU FAILED BACKLASH (C-CHECK RO 10/30/2021) REMOVED FAILING AND INSTALLED NEW / SERVICEABLE PCU AT RUDDER NO. 2 POSITION WITH NEW ATTACHING HARDWARE. OPS CHECK GOOD - REF CRJ700 AMM 27-23-01-400-801 A01. COMPLIED WITH TASK CARD 27-320-1001-SKY.SDR 2LCF202109130007Unknown · unknownON SEPTEMBER 7TH, DURING THE DESCENT AND LANDING OF THE AIRCRAFT N418LA THAT WAS CARRYING OUT MIA-BOG ROUTE (L7-1806), THE CREW FELT A STRONG RESPONSE FROM THE AIRCRAFT TO PITCH UP AND LATER A BOUNCE LANDING, A CIRCUMSTANCE UNDER WHICH THE CREW TOOK THE DECISISDR SWIA202162538None · failedHYDRAULIC SYSTEM #3 RUDDER PCU FAILED BACKLASH TEST (C-CHECK RO 11/10/2021) REMOVED AND REPLACED HYDRAULIC SYSTEM #3 RUDDER PCU IAW CRJ700 AMM CHAPTER 27-23-01-000-801-A01/27-23-01-400-801-A01, TORQUE WRENCH TUC 4978, CAL DUE: 32-JUL-22. PERFORMED BACKLASSDR SWIA202162537None · failedHYDRAULIC SYSTEM #1 RUDDER PCU FAILED BACKLASH TEST (C-CHECK RO 11/10/2021) REMOVED AND REPLACED HYDRAULIC SYSTEM #1 RUDDER PCU IAW CRJ700 AMM CHAPTER 27-23-01-000-801-A01/27-23-01-400-801-A01. T/W:TUC8615 CAL DUE 31OCT21. RE-ACCOMPLISHED RUDDER CONTROL SSDR SWIA202162536None · failedBACKLASH CHECK FAILED ON RH ELEVATOR #3 PCU (C-CHECK RO 11/10/2021) REMOVED R/H ELEVATOR PCU #3 AND INSTALLED SERVICEABLE PCU #3 IAW CRJ700 AMM CHAPTER 27-33-01-000-801-A01 AND CRJ700 AMM CHAPTER 27-33-01-400-801-A01. PERFORMED RIGGING OF THE ELEVATOR POSDR UIEA2021090101932Director · faultedINSTR SOURCE SELECTOR FLT DIR CAPT "C" FD "C" FOR BOTH FLT DIR PITCH UP. PERFORMED OPERATIONAL TEST OK PER AMM 22-10-00/715 REV 101/133. PERFORMED MCDP GND TEST L/O AUTO LAND OK PER AMM 72-03 F/T 820.SDR DALA2021083005096Computer · faultedSHIP 3271 ABORTED T/O DUE TO F/CTL ELAC 2 PITCH FAULT MESSAGE AT 40 KNOTS. RESET PER MCC INSTRUCTIONS. CORRECTIVE ACTION: R/R ELEVATOR SERVO CONTROL ACTUATOR SERVO VALVE PER A320 AMM 27-51. OPS TEST WAS GOOD. THERE WERE MULTIPLE LOG PAGES WRITTEN FOR THIS INCISDR SWIA202162342None · failedR/H ELEVATOR PCU #1 FAILED BACKLASH (C-CHECK RO 11-05-2021) REPLACED #1 RH ELEVATOR REF. CRJ 700 AMM 27-33-01-000-801-A03, AMM 27-33-01-400-801-A03. T.W.: TUC8608 DUE: 31-DEC-21. PERFORMED ELEVATOR POWER CONTROL UNIT RIGGING REF CRJ 700 AMM 27-33-01-820-80SDR SWIA202162341None · failedR/H ELEVATOR #2 PCU FAILED BACKLASH (C-CHECK RO 11-05-2021) REMOVED AND REPLACED RH #2 ELEVATOR PCU REF CRJ 700 AMM 27-33-01-400-801-A03. OPS CHECK GOOD, RIG CHECK GOOD. COMPLIED WITH TASK CARD 27-320-1003-SKYSDR SWIA202162340None · failedR/H ELEVATOR #3 PCU FAILED BACKLASH (C-CHECK RO 11-05-2021) REPLACED #3 RH ELEVATOR REF. CRJ 700 AMM 27-33-01-000-801-A03, AMM 27-33-01-400-801-A03T.W.: TUC8608 DUE: 31-DEC-21. PERFORMED ELEVATOR POWER CONTROL UNIT RIGGING REF CRJ 700 AMM 27-33-01-820-801-SDR AC2A2021082313901Actuator · faulted1 R AP FAIL CAS LIGHT ILLUMINATED DURING CHECK. REPLACED NO 1 ROLL ACTUATOR AND PERFORMED FUNCTIONAL CHECK.SDR SWIA202162346None · failedRUDDER PCU #1 BACKLASH FAILED (C-CHECK RO 11-05-2021) REMOVED AND REPLACED #1 RUDDER PCU REF CRJ700 AMM 27-23-01-400-801-A01. LEAK CHECK GOOD. OPERATIONAL CHECK GOOD. PCU RIGGED REF CRJ700 AMM 27-21-00-820-802-A01. BACKLASH CHECK GOOD REF CRJ700 AMM 27SDR SWIA202162344None · failedRUDDER PCU #2 BACKLASH FAILED (C-CHECK RO 11-05-2021) REMOVED AND REPLACED #2 RUDDER PCU REF CRJ700 AMM 27-23-01-400-801-A01. LEAKAGE TEST GOOD. OPERATIONAL CHECKOUT GOOD. BACKLASH TEST GOOD REF CRJ700 AMM27-21-00-720-803-A01. SKYWEST TASKCARDS 27-320-10SDR SWIA202162343None · failedRUDDER PCU #3 BACKLASH FAILED (C-CHECK RO 11-05-2021) REMOVED AND REPLACED #3 RUDDER PCU REF CRJ700 AMM 27-23-01-400-801-A01. LEAKAGE TEST GOOD. OPERATIONAL CHECKOUT GOOD. BACKLASH TEST GOOD REF CRJ700 AMM27-21-00-720-803-A01. SKYWEST TASKCARDS 27-320-10SDR SWIA202162650None · corrodedBOTH INBD. AND OUTBD. L/H ELEV. FLUTTER DAMPERS , ROD END HARDWARE (2 EA. NUTS AND WASHERS RUSTED) (C-CHECK- RO 11/11/21) REMOVED AND REPLACED LH IB OB FLUTTER DAMPER AFT HARDWARE IAW CRJ200 AMM 27-34-05-400-801 REFERENCE MX TRANS FOR INSTALL AND OPS TESTSDR SWIA202161947None · failedR/H ELEVATOR HYDRAULIC SYSTEM #1 PCU FAILED BACKLASH AT 0.440" AND FAILED LEAK CHECK. (C-CHECK RO 10-22-21) REMOVED AND INSTALLED SERVICEABLE, P/N 51000-9, R/H ELEVATOR HYDRAULIC SYSTEM #1 PCU. REF. CRJ900 AMM 27-33-01-000-801 (A01) AND AMM 27-33-01-400-80SDR SWIA202161946None · failedR/H ELEVATOR HYDRAULIC SYSTEM #2 PCU FAILED BACKLASH AT 0.350" AND FAILED LEAK CHECK. (C-CHECK RO 10-22-21) REMOVED AND REPLACED THE RH ELEVATOR #2 PCU WITH SERVICEABLE UNIT, REF CRJ 900 AMM 27-33-01-000-801-A01 AND CRJ 900 AMM 27-33-01-400-801-A01. OPESDR SWIA202161945None · failedR/H ELEVATOR HYDRAULIC SYSTEM #3 PCU FAILED BACKLASH AT 0.330" AND FAILED LEAK CHECK. (C-CHECK RO 10-22-21) REMOVED AND INSTALLED SERVICEABLE, P/N 51000-9, R/H ELEVATOR HYDRAULIC SYSTEM #3 PCU. REF. CRJ900 AMM 27-33-01-000-801 (A01) AND AMM 27-33-01-400-80SDR SWIA202161745None · corrodedRH WING INB GROUND SPOILER ACTUATOR HAS CORRODED HARDWARE AT ATTACH POINTS. (C-CHECK RO 10/8/2021) REMOVED AND INSTALLED NEW RH WING INB GROUND SPOILER ACTUATOR HARDWARE AT ATTACH POINTS REF CRJ200 AMM 27-65-01-400-801. OPS CHECK GOODSDR SWIA202161744None · corrodedRH WING OUTB GROUND SPOILER ACTUATOR HAS CORRODED HARDWARE AT ATTACH POINTS. (C-CHECK RO 10/8/2021) REMOVED AND REPLACED HARDWARE WITH NEW ON RH OTBD GROUND SPOILER IAW CRJ200 AMM 27-63-01-400-801 STEPS 2.B.(3)&(4) OPS CHECK GOODSDR SWIA202161743None · corrodedRH WING INB GROUND SPOILER HAS CORRODED HARDWARE AT MIDDLE HINGE CONNECTION TO ACTUATOR. (C-CHECK RO 10/8/2021) .REMOVED AND INSTALLED NEW HARDWARE TO THE RH WING INBOARD GROUND SPOILER HINGE. REF CRJ200 AMM 27-65-01-400-801. OPS CHECK GOODSDR SWIA202161742None · corrodedRH WING OUTB GROUND SPOILER HAS CORRODED HARDWARE AT MIDDLE HINGE CONNECTION TO ACTUATOR. (C-CHECK RO 10/8/2021) REPLACED CORRODED HARDWARE AT R/H WING O/B GROUND SPOILER MIDDLE HINGE TOPSIDE CONNECTION AREA TO ACTUATOR WITH NEW WASHER (P/N: NAS1149C05SDR SWIA202161741None · corrodedLH WING INB GROUND SPOILER ACTUATOR HAS CORRODED HARDWARE AT ATTACH POINTS. (C-CHECK RO 10/8/2021) REMOVED AND INSTALLED NEW LH WING INB GROUND SPOILER ACTUATOR HARDWARE AT ATTACH POINTS. REF CRJ200 AMM 27-65-01-400-801. OPS CHECK GOODSDR SWIA202161740None · corrodedLH WING OUTB GROUND SPOILER ACTUATOR HAS CORRODED HARDWARE AT ATTACH POINTS. (C-CHECK RO 10/8/2021) INSTALLED NEW BOLT (P/N:NAS6205-12D), 2 WASHERS (P/N:NAS1149D0516K/NAS1149D0563K), 1 NUT (P/N:MS17826-5), 1 COTTER PIN (P/N:MS24665-134) TO REPLACE CORROSDR SWIA202161739None · corrodedLH WING OUTB GROUND SPOILER HAS CORRODED HARDWARE AT MIDDLE HINGE FITTING CONNECTION TO ACTUATOR. (C-CHECK RO 10/8/2021) INSTALLED NEW WASHER (P/N: NAS1149C0563B), NUT (P/N: MS17826-5) AND COTTER PIN (P/N: MS24665-134) TO REPLACE CORRODED HARDWARE AT L/SDR SWIA202161738None · corrodedLH WING, INB FLIGHT SPOILER, INB PCU HAS CORRODED HARDWARE AT LOWER ATTACHMENT POINT. (C-CHECK RO 10/8/2021) REMOVED AND REPLACED L/H WING I/B FLIGHT SPOILER I/B PCU LOWER ATTACHMENT POINT HARDWARE REF CRJ 200 AMM 27-62-01-000-801 STEP 3. D. (4-5) AND RSDR SWIA202161737None · corrodedLH WING, INB FLIGHT SPOILER, OUTB PCU HAS CORRODED HARDWARE AT LOWER ATTACHMENT POINT. (C-CHECK RO 10/8/2021) REMOVED AND REPLACED L/H WING I/B FLIGHT SPOILER O/B PCU LOWER ATTACHMENT POINT HARDWARE REF CRJ 200 AMM 27-62-01-000-801 STEP 3.D. (4-5) AND CSDR SWIA202161603None · corrodedFOUND CORROSION ON THE RH AILERON OTBD PCU AT LINK ATTACHMENT POINT (C-CHECK RO 10/4/2021) REMOVED AND REPLACED WITH A NEW PART. RH AILERON OUTBOARD PCU. REF. CRJ200 AMM 27-14-01-000-801 AND CRJ200 AMM 27-14-01-400-801 SEE CONTINUE CARD FOR FURTHER DESDR SWIA202161602None · corrodedFOUND CORROSION ON THE RH AILERON INBD PCU AT LINK ATTACHMENT POINT (C-CHECK RO 10/4/2021) REMOVED AND REPLACED RH AIL/INBD PCU W/NEW PARTS IAW CRJ200 AMM 27-14-01-400-801. COMPLIED WITH TASK CARD 27-900-1002-SKY.SDR SWIA202161601None · corrodedFOUND CORROSION ON THE LH AILERON OTBD PCU AT LINK ATTACHMENT POINT (C-CHECK RO 10/4/2021) REMOVED AND REPLACED LH OUTBOARD AILERON PCU WITH SERVICABLE PART AS PER CRJ 200 AMM 27-14-01-000-801 AND CRJ 200 AMM 27-14-01-400-801 CALIBRATED TOOL USED TUC48SDR SWIA202161600None · corrodedFOUND CORROSION ON THE LH AILERON INBD PCU AT LINK ATTACHMENT POINT (C-CHECK RO 10/4/2021) REMOVED AND REPLACED WITH A NEW PART THE LH INBOARD PCU ASSEMBLY. IAW CRJ200 AMM 27-14-01-000-801 AND THE CRJ200 AMM 27-14-01-400-801 SEE CONTINUE CARD FOR FURTHSDR SWIA202161676None · corrodedRH WING SPOILERON PCU LOWER MOUNT BOLT NUTS AND WASHERS ARE CORRODED (C-CHECK RO 10/07/2021) REMOVED AND REPLACED RH WING SPOILERON PCU LOWER MOUNT BOLT NUTS AND WASHERS IAW CRJ 200 AMM 27-62-01-000/400-801 OPS CHECK GOOD REF ATTACHED CONTINUATION CARD FSDR SWIA202161675None · corrodedRH WING FLIGHT SPOILER PCU LOWER MOUNT BOLTS NUTS AND WASHERS ARE CORRODED (C-CHECK RO 10/07/2021) REMOVED UNSERVICEABLE RH WING FLIGHT SPOILER PCU LOWER MOUNT NUTS/WASHERS & REPLACED WITH SERVICEABLE NUTS/WASHER IAW CRJ 200 AMM 20-21-00-910-801SDR SWIA202161674None · corrodedRH WING SPOILERON IB & OB MOUNT BOLTS NUTS AND IB AND OB KEEPER BOLTS ARE CORRODED (C-CHECK RO 10/07/2021) REMOVED AND REPLACED RH WING SPOILERON IB AND OB MOUNT BOLTS NUTS AND IB AND OB KEEPER BOLTS IAW CRJ 200 AMM 27-64-05-000/400-801 OPS CHECK GOOD RE
Back to JASC 2700