SDR SWIA2019110546668Pump · damagedL/H BOOST PUMP 4 EA. FLAW INDICATIONS EMITTING FROM SATELLITE HOLES. (C-CHECK) RO: 11/04/2019 COMPLIED WITH CARD 51-900-1003-SKY AND FORM M-337SDR AALA201911059002Pump · unreliableAIRCRAFT WAS GROUNDED: PILOT REPORTS FUEL FED FROM RT WING DURING TAKEOFF INSTEAD OF CTR TANK. ALL BOOST PUMPS ON-WINGS BOTH AT 8.44/8.42/CTR 11.7-ON CLIMB OUT, RT WING WENT 500LBS LOW AND FUEL TOTALS WERE FINE- AT 7000 IN CLIMB, FUELS READ LEFT 8.44/CTR 10.SDR UIEA2019110403840Warning Message · false activationEICAS MESSAGE FOR LT FWD FUEL PUMP. CYCLED LT FWD FUEL PUMP CIRCUIT BREAKER IAW AMM 28-22-01, OPS CHECKED OK. MESSAGE CLEARED IAW AMM 28-22-01.SDR UIEA2019102965794Warning Message · false activationON APPROACH, LEFT FORWARD FUEL PUMP EICAS MESSAGE. (<P>PERFORMED OPS TEST IAW AMM 28-22-00, OPS CHECK GOOD. </P>)SDR UIEA2019102535785Relay · inoperativeR CENTER TANK PUMP INOP(<P>TRANSFERRED TO MDDR 119560 PER MEL 28-22-02B, CAT C, PLACARD INSTALLED.</P><P>LP 1097265 - M8: PER MCC REQUEST, REMOVED AND REPLACED RIGHT CENTER PUMP GFI RELAY IAW AMM 28-22-18. R CTR BOOST PUMP OPERATIONAL CHECK NORMAL AT THIS TIMESDR UIEA2019102105768Warning Message · false activationL FWD FUEL PUMP PRESS, QRH COMPLETED.(<P>PERFORMED OPS TEST IAW AMM 28-22-00, OPS CHECK GOOD.</P>)SDR UIEA2019102105762Warning Light · no indicationAFTER SHUTTING DOWN BOTH ENGINES, WITH APU RUNNING AND TURNING ALL FUEL PUMPS OFF, THE LEFT AFT FUEL PUMP LOW PRESSURE LIGHT NOT ILLUMINATED.(<P>PERFORMED OPERATIONAL TEST OF THE LEFT AFT FUEL PUMP PER AMM 28-22-03, OPS CHECK NORMAL.</P>)SDR AALA2019101879004Pump · unreliableAIRCRAFT WAS GROUNDED: PILOT REPORTS SHORTLY AFTER TAKE OFF, RECEIVED RIGHT TANK ENGINE PUMP 2 LOW PRESSURE WARNING. MAINTENANCE REMOVED AND REPLACED RT WING FUEL PUMP IAW AMM 28-21-51. ACCOMPLISHED LEAK AND OPERATIONAL TEST, FOUND OK IAW AMM 28-21-51-710.SDR ASAA2019102153033Motor · failedAFT #1 MAIN FUEL PUMP "LOW PRESSURE" LIGHT ILLUMINATED ON CLIMB AND REMAINED AT CRUISE. THE TANK HAD 8500 LBS IN IT. GROUNDED - YES. REPLACE #1 AFT MOTOR IMPELLER BOOST PUMP. CLOSED 1 EA CIRCUIT BREAKER. GROUND VERIFICATION TEST SUCCESSFUL.SDR 2019FA0000334Bearing · wornFUEL CONTROL UNIT PROBLEMS ASSOCIATED WITH CONTROL ROD END BEARING WEAR.SDR CALA2019100701710Relief Valve · malfunctionedFUEL IMBALANCE 4700LBS TOT NOW 30.2/CALC 31.2 HOLDING STEADY MPERFORMED REFUEL / JETTISON AND MANIFOLD LEAK CHECK PER AMM 28-21-00-12A-364A-A , NO DEFECTS NOTED . FURTHER T/S PER FIM 28-00-F0-05A-421A-A UP TO STEP 2 (A) 1 . WILL REQUIER CONTIUATION OF FAULT ISSDR UIEA2019100755650Warning Message · false activation"L FWD FUEL PUMP" EICAS MSG DURING CLIMB UNTIL CRUISE. RAN QRH, MSG DISAPPEARED PRIOR TO QRH COMPLETION. COMPLIED WITH FIM 28-22 F/T 819, COULD NOT DUPLICATE FAULT. THE FUEL PUMP OPS NORMAL . ACFT OK FOR SERVICE.SDR ASAA2019100743931Warning Light · false activationLEFT CENTER FUEL PUMP CAME ON WITH 1080 LBS. GROUNDED - YES. FUELED CENTER TANK TO 14000 LBS. BOTH L/CENTER AND R/CENTER LOW PRESS LIGHTS CAME ON THEN OFF IMMEDIATELY. CLASSED AS INTERMITTENT FAULT. OK FOR SERVICE, REF B737-800 FIM 28-22 TASK 801.SDR UIEA2019100745644Warning Message · false activation"LEFT FWD FUEL PUMP" EICAS MESSAGE CAME ON TWICE, FOR 1 - 2 MINUTES, JUST PRIOR TO REACHING CRUISE ALT. COMPLIED WITH FIM 28-22 FT 819, COULD NOT DUPLICATE. FUEL PUMP OPS CHECKED NORMAL. ACFT OK FOR SERVICE.SDR UIEA2019100305633Relay · malfunctionedLEFT CENTER FUEL PUMP INOPERATIVE. RESET GFI RELAY K10697. RAN ENGINES, OPS CHECK NORMAL IAW FIM 28-22 FT 805 AND AMM 71-00-00.SDR ASAA2019100723932Pump · inoperativeNR MAIN FUEL TANK, FWD ELECT FUEL PUMP INOPERATIVE. GROUNDED - YES. REPLACED THE NR FWD BOOST PUMP IAW AMM 28-22-41. LK AND OPS CK GOOD. ETOPS GROUND VERIFICATION SUCCESSFUL.SDR CALA2019100501699Pump · failedSUSP FUEL LEAK, RT ENG 700 LB LOSS BY 20 MIN AFTER T/O. VIS WHISP FROM F/A SEEN. PERFORMED FQIS BITE TEST PER FIM 28-41-00-810-801. TEST PASSED. NO FAULT FOUND AT THIS TIME. PER TOMC REQUEST, REMOVED AND REPLACED RH CTR FUEL BOOST PUMP IN REF TO AMM 28-22-41. SDR UIEA2019100215620Warning Message · false activationCENTER RIGHT FUEL PUMP EICAS MESSAGE, AFTER START. INSPECTED WIRING AT THE PUMP PER SWPM 20-10-06, NO DEFECTS NOTED. RT CENTER FUEL PUMP OPS CHECK GOOD IAW AMM 28-22-00. TRANSFERRED 10,000 LBS INTO CENTER TANK AND BACK IAW AMM 28-26-00, OPS CHECKED GOOD.SDR UIEA2019100135613Circuit Breaker · trippedL FWD FUEL BOOST PUMP CIRCUIT BREAKER POPPED AFTER TURNING FUEL PUMPS ON (<P>RESET CIRCUIT BREAKER AND OPS CHECKED FUEL PUMP I.A.W AMM 28-21-00 NO FAULTS AT THIS TIME </P>)SDR UIEA201910015594Pump · malfunctionedDURING TAXI OUT CENTER LEFT FUEL PUMP EICAS MESSAGE DISPLAYED WITH APPROX 33.1 LBS OF FUEL IN CENTER TANK. REMOVED AND REPLACED LEFT OVERRIDE PUMP IAW AMM 28-22-05. OPS AND LEAK CHECK GOOD AT THIS TIME.SDR UIEA2019092405562Pump · faultyFUEL CONFIG EICAS MSG AS A RESULT OF WRITE UP #1. AFTER ROTATION, APPROX 1, 800 LBS IMBALANCE. FUEL BALANCED WHEN PUMP TURNED BACK ON. DUE TO HISTORY, REMOVED AND REPLACED R FWD BOOST PUMP IAW AMM 28-22-03. OPS CHECK NORMAL AT THIS TIME, NO LEAKS NOTED.SDR AALA201909239019Impeller · defectiveAIRCRAFT WAS GROUNDED: FLIGHT AIR RETURNED TO MIA ON ACCOUNT OF POSSIBLE FUEL LEAK. EMERGENCY DECLARED. MAINTENANCE REMOVED AND REPLACED RH WING PROBES AND COMPENSATOR IAW AMM 28-41-21, ALSO WIRE HARNESS IAW AMM 28-41-44, NO LEAK FOUND. MAINTENANCE FOUND RT CTSDR UIEA2019092105553Unknown · malfunctionedLEFT AFT FUEL PUMP WILL NOT TURNOFF WHEN DE-SELECTED, NO PRESSURE LIGHT OR ASSOCIATED EICAS MESSAGE. PERFORMED OPS TEST LEFT AFT FUEL PUMP IAW AMM 28-22-00-1. OPS CHECKED GOOD, PRESSURE LIGHT AND EICAS MESSAGE WHEN PUMP OFF.SDR ASAA2019091830726Relay · failed#2 FWD FUEL PUMP LOW PRESSURE LIGHT ILLUMINATED WITH PUMP ON. GROUNDED - YES. REF TSR 703841, REMOVED #2 FWD BOOST PUMP GFI RELAY R21 PER AMM 28-22-18-000-801. INSTALLED NEW RELAY R21 PER AMM 28-22-18-400-801. PERFORMED (GFI) RELAY OPERATIONAL TEST PER AMM 28-SDR UIEA2019091905539Warning System · false activationAT TOP OF DESCENT, EICAS MSG "R FWD FUEL PUMP" FOR ABOUT 10 SEC. PERFORMED OPERATIONAL TEST OF R FWD FUEL PUMP IAW AMM 28-22-00. NO MESSAGES SHOWN OR FAULTS NOTED. OPS CHECK NORMAL AT THIS TIME.SDR UIEA2019091705517Warning System · false activationCTR R FUEL PUMP EICAS MESSAGE, BEFORE T/O. OPS CHECK CTR R FUEL PUMP IAW AMM 28-22-00, OPS CHECK GOOD.SDR CALA2019091701555Actuator · inoperativeFUEL SPAR VALVE L STAT MESSAGE REPLACED LT FUEL SPAR ACTUATOR REF AMM 28-22-02-400-802. OPERATIONAL CHECKS GOOD. NO MESSAGES PRESENT. ROTABLE PARTS CHANGE WAS INDICATED - TT # 1378424 SN OFF 1462 ACTUATOR, VALVE OFF 29-2822-9-9014 1462 ON 29-2822-9-9014 56SDR ASAA2019091530717Pump · inoperative#2 TANK FWD BOOST PUMP SHOWED LOW PRESSURE. GROUNDED - YES. REMOVED AND REPLACED #2 FWD FUEL PUMP IAW AMM 28-42-22/401. GROUND VERIFICATION AND LEAK CHECK SUCCESSFUL PER AMM 28-22-41-710-801.SDR UIEA2019091605514Relay · failedL FWD FUEL PUMP EICAS IN FLIGHT. REFERENCE LP 1049220 - ITEM 1: FOUND TERMINALS A-1, A-3, AND C1 LOOSE INSIDE K102 GROUND SERVICE TRANSFER RELAY. REMOVED AND REPLACED K102 IAW AMM 24-51-03. PERFORMED INSTALLATION TEST IAW AMM 24-51-03, NO DEFECTS NOTED. ITEM 2SDR ASAA2019082863519Warning Light · inoperativeLF AFT MAIN FUEL BOOST PUMP DID NOT ILLUMINATE AFTER ENGINE SHUT DOWN WITH SW POSITIONED TO OFF. GROUNDED - YES. UNABLE TO CONFIRM FAULT. PERFORMED LEFT AFT FUEL BOOST PUMP OPERATIONAL TEST REF B737-800 AMM 28-22-41-710-801. OPERATED BOOST PUMP MULTIPLE TIMES SDR UIEA2019082655281Pressure Switch · malfunctionedCTR R FUEL PUMP EICAS MESSAGE WITH 2,300 LBS IN CTR TANK. PERFORMED POWER WIRE CHECK, NO POWER A1, B1, C1 K330 RELAY. REMOVED AND REPLACED K330 RELAY PER WDM 28-22-13, NO HELP. REMOVED AND REPLACED RIGHT CENTER OVERRIDE PRESSURE SWITCH IAW AMM 28-42-01. OPSSDR UIEA2019082505279Pressure Switch · malfunctionedCTR LEFT FUEL PUMP INOP. PERFORMED FIM TASK 28-22 FT 805 UP TO AND INCLUDING SHEET 3 BLOCK 49/50. SYSTEM (PUMP) WORKED AS REQUIRED, PER FIM RECOMMEND PRESSURE SWITCH PN # 60B92400-7 (LOC:S423) REF WDM 28-22-12. REMOVED AND REPLACED CENTER (OVERRIDE) LT FUELSDR SWAA2019082736264Pump · low pressureLEFT CENTER FUEL PUMP LOW PRESSURE LIGHT ON W/2800 LBS. FUEL IN TANK. R&R LT CENTER BOOST PUMP PER AMM.SDR UIEA2019082095224Warning Message · false activationAFTER DEPARTURE, RECEIVED R FWD FUEL PUMP & FUEL IMBALANCE EICAS MSG. LEFT WING HAD 3,000 LBS LESS THEN RIGHT TANK, WE WERE GOING TO RUN QRH PROCEDURES THEN FUEL BALANCED OUT AND EICAS MESSAGES WENT AWAY. MONITORED FUEL IN BOTH MAIN TANKS FOR 4 HRS, NO UNWANSDR AALA2019081439014Circuit Breaker · failedAIRCRAFT WAS GROUNDED: PILOT REPORTS ON CLIMBOUT RIGHT CENTER TANK LOW PRESSURE LIGHT ILLUMINATED WITH PUMP SWITCH ON UNABLE TO USE CENTER TANK FUEL. MAINTENANCE REMOVED AND REPLACED CTR TANK RT BOOST PUMP CIRCUT BREAKER IAW AMM 20-30-00. OPS CHECK GOOD.SDR AALA2019081429028Pressure Switch · failedAIRCRAFT WAS GROUNDED: PILOT REPORTS AFTER TAKEOFF, ECAM RIGHT CENTER TANK FUEL PUMP 2 INOP. MAINTENANCE REMOVED & REPLACED CTR TANK 2 FUEL PRESSURE SWITCH (40QA) IAW AMM 28-21-15. OPS CHECK & LEAK CHECK GOOD.SDR UIEA2019081205009Relay · unknownLEFT CENTER PUMP LOW PRESSURE LIGHT ILLUMINATED. TROUBLESHOT THE LEFT CENTER BOOST PUMP IAW FIM 28-22 FT 805, NO FAULTS NOTED. THE LEFT CENTER LIGHT STARTS FLASHING AROUND 1500 POUNDS, THIS IS NORMAL. RT CTR WILL PUMP TO .4 POUNDS. REOPENED ORIGINAL MDDR SDR AALA2019081209015Fault Light · false activationAIRCRAFT NOT GROUNDED: PILOT REPORTS LEFT CENTER TANK PUMP FAULT. MAINTENANCE PERFORMED TSM 28-21-00-810-813-A. FOUND NO C/B OR GFI TRIPPED. FUNCTIONAL TEST NORMAL. NO FAULTS NOTED.SDR 2020FA0000036Pump · failedFUEL BOOST PUMP FAILED ON ENGINE RUN UP. UPON INSPECTION, FOUND FUEL BOOST PUMP IMPELLERS NO LONGER INTACT. ATTENTION TO THE ISSUE WAS INITIATED BY A LOW FUEL PRESSURE WARNING. A LOUD GRINDING NOISE COULD BE HEARD WHENEVER THE FUEL BOOST SWITCH WAS MOVED TO SDR AALA201908099021Warning Light · false activationAIRCRAFT NOT GROUNDED: MAINTENANCE REPORTS RT CTR FUEL PUMP LIGHT ILLUMINATED WITH CTR TANK SELET PUMP ILLUMINATED. MAINTENANCE INSPECTED R/H PUMP CANISTER & PICK UP LINE INSIDE TANK NO DEFECTS NOTED.SDR 2WAA201908080006Pump · malfunctionedDURING CRUISE FWD CENTER PUMP STOPPED WORKING. DIVERSION TO MMUN. PERFORMED AIRCRAFT FUEL SUMP IAW MD-80 AMM 12-11-08. FUEL NORMAL. PERFORMED OPS CHK OF FUEL BOOST PUMP IAW MD-80 AMM 28-20-07 OPS CHK NORMAL. COULD NOT DUPLICATE ON GROUND. THIS ACTION CLEARS DMSDR UIEA2019080404943Warning Message · false activationLEFT CENTER FUEL PUMP INOP ON TAXI OUT.(<P>TRANSFERRED TO MDDR 115786 IAW DDG 28-22-02A, CAT C. TROUBLESHOT L CTR FUEL PUMP IAW FIM 28-22 FAULT TREE 805. NO DEFECTS NOTED, OPS CHECK GOOD.SDR AALA2019080529010Impeller · damagedAIRCRAFT WAS GROUNDED: PILOT REPORTS NR 2 FORWARD LOW PRESSURE LIGHT ILLUMINATED WITH PUMP TURNED ON. MAINTENANCE ACCOMPLISHED FIM TASK 28-22-810-806 STEP G- NO FAULTS NOTED. ACCOMPLISHED STEP H - REPLACED TANK 2 FWD BOOST PUMP LOW PRESSURE SWITCH-S153- NO HELSDR UIEA2019080204930Warning Message · no indicationRT SPAR VALVE DID NOT ILLUMINATE. TEST LIGHT OK BEFORE SHUT DOWN. PERFORMED FUNCTIONAL CHECK OF BOTH LEFT AND RIGHT SPAR VALVES IAW AMM 28-22-00, FUNCTIONAL TEST NORMAL. ALSO, PERFORMED RT ENGINE IDLE RUN AND OPS CHECK OF SPAR VALVE IS NORMAL.</P>)SDR AALA2019080139019Pump · defectiveAIRCRAFT WAS GROUNDED: PILOT REPORTS FUEL IN NR 2 MAIN SEEMS TO BE BURNING DURING CENTER TANK OPERATION. BOTH MAIN TANKS FULL AT DEPARTURE, 8.2. WHEN CENTER TANK EMPTY NR 1 MAIN 8.1 AND NR 2 MAIN 7.3. MAINTENANCE REPORTS PREVIOUS PUMP INSTALLED RECENTLY BAD FRSDR AALA201907300045Warning Message · false activationAIRCRAFT WAS GROUNDED: PILOT REPORTS RT CENTER FUEL PUMP LIGHT ILLUMINATED WITH 3.4 IN CTR TANK . MAINTENANCE INSPECTED R/H PUMP CANISTER & PICK UP LINE INSIDE TANK, NO DEFECTS NOTED AT THIS TIME. LEAK CHECK IAW AMM 28-11-11, NO LEAKS NOTED.SDR AALA201907269013Pump · failedAIRCRAFT WAS GROUNDED: FLIGHT DIVERTED TO MIA ON ACCOUNT OF CENTER TANK FUEL PUMP INOPERATIVE. AFTER TAKEOFF FUEL STARTED DRAINING FROM WINGS WITH 16,000 LBS IN CENTER, COULD NOT STOP EVEN WITH PUMPS OFF. L-WING WENT TO 8.08, RT 7.86 W/10,000 IN CENTER. AN EMESDR HALA2019072400367Actuator Valve · faultyETOPS / APU AUTO SHUTDOWN ECAM MSG "FUEL TRIM LINE FAULT". REPLACED RECEPTACLE 5201VC. REPLACED FUEL TRIM TK INLET VALVE ACTUATOR PER AMM 28-27-52.SDR CALA2019072401228Pump · inoperativeON CLB OUT CENTER TANK AND RIGHT MAIN TANK WERE DEPLETING FUEL A T THE SAME RATE. PER CREW BRIEFING "RT WING TANK WAS DROPPING AT THE SAME RATE AS THE LEFT AND CENTER COMBINED." REF LP 3794838 REMOVED AND REPLACED CTR TANK RT PUMP. ACCOMPLISHED TS FOR POSSIBLESDR UIEA2019071404749Pump · malfunctionedCENTER RT FUEL PUMP EICAS.(<P>TRANSFERRED TO MDDR 114716 PER MEL 28-22-02A, CAT C, DUE DATE 24-JUL-19.</P><P>LP 1099299 - M2: REMOVED AND REPLACED RIGHT AUX TANK FUEL OVRD PUMP PRESSURE SWITCH IAW AMM 28-42-01, NO HELP. OFF PART (PN: 21C1-3-21, S/N W033388)</P
Back to JASC 2822