SDR UALA2009062901823Packing · defectiveLEFT HYD LEAK IN FLIGHT. FLIGHT DIVERTED. REPLACED LT ENG DRIVEN HYD PUMP BLEEDER PLUG PACKING. SERVICED LT HYD SYSTEM TO FULL. EDP TESTS GOOD. NO LEAKS, NO MSG ON ECS, EPCS EICAS.SDR CA090630003Pump · failed(CAN) WHILE IN APPROACH TO BASE, CREW NOTE THAT HYD QUANTITY WAS DROPPING. PROCEED WITH A NORMAL GEAR EXTENSION. CREW REQUEST ERS ON STANDBY. CAUTION LIGHT`S: NR 2 ENG HYD AND NR 2 HYD ISO VALVE. NR 2 EDP REPLACED.SDR NSVA2009032Pump · inoperativeNR 2 HYD PUMP LIGHT ILLUMINATED AND ISO VALVE LIGHT ILLUMINATED. REMOVED AND REPLACED THE EDP AND PERFORMED FULL SYS FLUSHING AS REQUIRED.SDR AALA2009062400007Pump · shearedDFW - AFTER TAKEOFF RIGHT ENGINE DRIVEN HYDRAULIC PUMP FAILED AND THE NUMBER 2 AUTOPILOT FAILED. EMERGENCY DECLARED, RETURNED DFW WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. FOUND NUMBER 2 ENGINE DRIVEN PUMP SHAFT SHEARED. REPLACED NUMBER 2 ENGINE DRISDR CA090709007Pump · leaking(CAN) NR 2 ENG EDP LEAKING AT CASING WHERE PRESSURE LINE CONNECTED. PUMP REPLACED.SDR AALA200906200003Pump · inoperativeJFK - AIRCRAFT LOST GREEN HYDRAULIC SYSTEM QUANTITY AND PRESSURE. REPLACED LEFT ENGINE GREEN HYDRAULIC PUMPS AND CASE DRAIN FILTER. SYSTEM GROUND CHECK NORMAL OPERATION.SDR 2009FA0000581Pump · failedLT HYD PUMP FAILED IN FLIGHT. (K)SDR HALA2009060900233Pump · failedETOPS SIGNIFICANT SYSTEM, FRM 2911XD00 C HYD ADP DEMAND PUMP DOES NOT PROVIDE FULL PRESS IN AUTO MODE. PRESS NORMAL W/SW IN ON POSITION. EICAS MSG "C HYD DEM PUMP' ILLUM W/CENTER SYSTEM DEMAND. PERFORMED FIM 29-11-00 REPLACED MODULATING VALVE FOR THE AIR DRSDR CVGA0915801Pump · failedDURING PART 91 REPOSITIONING LEG FROM PDK TO FXE, CREW HEARD A LOUD NOISE FROM LEFT SIDE OF AIRCRAFT WHILE IN CRUISE. NOISE QUIT AFTER 10 MINUTES AND LOW HYD PRESS LIGHT ILLUMINATED. CREW DIVERTED TO PBI AS IT HAD A LONGER AVAILABLE RUNWAY THAN FXE. INSPECTIONSDR N6WA20090607Pump · malfunctionedLT HYD LOW. REMOVED AND REPLACED NR 1 ENGINE HYD PUMP IAW AMM 29-11-01. OPS AND LEAK CHECK GOOD AT THIS TIME.SDR AALA2009060300002Module · inoperativeLAX - AIRCRAFT EXPERIENCED A LEFT HYDRAULIC SYSTEM FAILURE AFTER TAKEOFF. EMERGENCY DECLARED RETURNED LAX WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED LEFT PYLON ENGINE DRIVEN PUMP HYDRAULIC MODULE. SYSTEM GROUND CHECK NORMAL OPERATION.SDR AALA2009060100007Pump · malfunctionedIAD - DURING FLIGHT THE NUMBER 1 AND 2 HYDRAULIC LOW PRESSURE ANNUNCIATOR ILLUMINATED. REPLACED B-SYSTEM HYDRAULIC PUMP AND INSTALLED RETURN AND PRESSURE FILTERS. SYSTEM GROUND CHECK NORMAL OPERATION.SDR HALA2009052900206Pump · making metalETOPS SIGNIFICANT SYSTEM - BTB - ON TAXI OUT L PRIM HYD OVHT EICAS ILLUMINATED. PERF FIM 29-11-00 FIG 117. FOUND CASE DRAIN EDP FILTER CLOGGED W/METAL PARTICLES. REPLACED NR 1 EDP PER AMM 29-11-05 OPS AND LK CK PEND. FLUSH L HYD SYS PER AMM 29-11-00-172-11SDR UALA2009052701527Pump · faultyTHE C-HYD PRIM 1 EICAS AND C-HYD SYS MAINT STATUS ACTION PUMP TURNED OFF. FOUND FILTER DELTA P PIN POPPED. REPLACED CENTER SYSTEM AC MOTOR DRIVEN HYD PUMP.SDR UALA2009052601508Pump · failedENGINE HYDRAULIC PUMP FAILURE. RTFL. REPLACED NR 1 ENG HYD PUMP. ALSO REPLACED ENG PUMP CASE DRAIN FILTER AND HP FILTER. BOTH FILTERS CHECK NORMAL.SDR AALA2009052400001Pump · inoperativeDFW - RIGHT HYDRAULIC PRESS DECLINED TO ZERO FOLLOWED BY RIGHT HYDRAULIC PRESS LOW LIGHT AND RUDDER MANUAL LIGHT CAME ON. RETURNED DFW WITHOUT INCIDENT. REPLACED RIGHT ENGINE HYDRAULIC PUMP. SYSTEM GROUND CHECK NORMAL OPERATION.SDR UALA2009052601495Pump · faultyGREEN SYSTEM LOW PRESSURE MESSAGE FOLLOWED BY LOSS OF GREEN HYD QUANTITY. FLIGHT DIVERTED, REPLACED NR 1 ENG DRIVEN PUMP. REPLACED ENGINE CASE DRAIN FILTER AND GREEN SYSTEM LOW PRESSURE FILTER. CASE DRAIN LINE NR 1 ENG HAD A SMALL HOLE. REPLACED LINE.SDR UALA2009051801406Pump · faultyCREW REPORTS, LEFT EDP LIGHT AND EICAS ILLUMINATED SEVERAL TIMES. FIRST OCCURRENCE INCLUDED AURAL WARNING AND MAINTENANCE PAGE AUTO RECORDED LEFT SYS PRESSURE OF 470 PSI. REPLACED LEFT ENG DRIVEN HYD PUMP. ALSO REPLACED K131 L PRESS SENSE RLY AND HYD SYS LSDR Y2PA2009051400002Pump · inoperativeDURING CLIMBOUT, RT ENGINE DRIVEN HYD PUMP PRESSURE DROPPED (INDICATED) "0" PRESSURE. (LT SYS NORMAL) PERFORMED COM PROCEDURE - RESTORED RT SYS PRESSURE WITH "AUX" PUMP. AT 18,000 FT APPROACH CHECKLIST ALTITUDE, DECLARED AN EMERGENCY WITH APPROACH AS A PRECSDR A6WA200940258Pump · inoperativeHYD SYS NR1 QUANTITY DROPPED TO 25 PERCENT IN FLIGHT. REMOVED AND REPLACED ENG DRIVEN HYD PUMP NR 1 IAW AMM 29-11-01. OPS AND LEAK CHECKS GOOD. (K)SDR HALA2009051300174Pump · leakingETOPS SIGNIFICANT SYSTEM, DURING WALK AROUND FOUND NR 1 ENGINE DRIVEN HYD PUMP LEAKING. REPLACED EDP PER AMM 29-11-05. PERFORMED OPERATIONAL AND LEAK CHECK. CHECKS OK. OK FOR SERVICE.SDR UALA2009051101345Pump · malfunctionedADP LOW PRESS LIGHT AND EICAS MSG ON TAKEOFF DURING GEAR RETRACTION & FLAPS 5 TO 1. REPORTED BY CREW. REMOVED AND REPLACED ADP. NO HELP. STILL NEED TO LEAK CHECK, NEEDS FURTHER TROUBLESHOOTING. REPLACED MOD. AIR DRIVEN PUMP AND ADP REG AND SHUTOFF VALVES (3SDR SWIA200921535Pump · failedFLT 2719 - GEAR DISAGREE WARNING ON APPROACH. REPLACED HYDRAULIC PUMP 3A.SDR NWAA 091496623Pump · leakingDURING FLIGHT THERE WAS A SUDDEN LOSS OF NR 4 HYDRAULIC QUANTITY WHICH RESULTED IN A LOSS OF PRESSURE AND QUANTITY WENT TO ZERO. FLIGHT CONTINUED ON AND LANDING WAS UNEVENTFUL. ALTERNATE GEAR AND FLAP SYSTEMS WERE USED. MAINTENANCE FOUND NR 4 ENGINE DRIVEN SDR UALA2009043001267Pump · faultyRIGHT CENTER HYDRAULIC PUMP WILL NOT PRESSURIZE. REPLACED NR 2 CTR ACMP. NR 2 CTR ACMP PRESSURE LINE AND OR UNION LEAKING, LINE DISCONNECTED AND UNION REMOVED. REPLACED UNION, CONNECTED LINE. OPS CK'D PUMP, LEAK CK'D GOOD.SDR CALA2009043000230Pump · defectiveAIR RETURN, LOSS OF "A" HYDRAULIC FLUID. ENG 1 HYD PUMP OFF PRESSURE WOULD INTERMITTENTLY RETURN ON AND OFF WITH GROWL NOISES. REPLACED NR 1 ENG "A" PUMP PER AMM 29-11-11-400-802-0022. REPLACED RETURN FILTER PER AMM 29-15-61 AND EDP FILTER PER 29-15-91. RASDR DXTA2009043003624Pump · leakingRIGHT AFTER TOUCHDOWN, LT "LO HYD FLOW" LIGHT ILLUMINATED. ALSO RT "LO HYD FLOW" LIGHT ILLUMINATED, FOLLOWED BY "LO HYD LEVEL" & "STAB MISCOMPARE" LIGHT. ON POST FLT, FOUND HYD FLUID ON LT BACK THIRD OF ACFT. R&R LT HYD PUMP, FILTER & PRESS LINE. FLUSHED LISDR CA090507003Spline · worn(CAN) PUMP INSTALLED AS PART OF HYDR LANDING GEAR SYS. THE WORN SPLINE WAS NOTED DURING A SCHEDULED LANDING GEAR ELECTRIC MOTOR REPLACEMENT. THE COUPLER SPLINES BETWEEN THE HYDR PUMP AND ELECTRIC MOTOR WERE ALSO WORN OUT.SDR USAA2009050191061Pump · defectiveFLT 933 - ORD-CLT - EMERGENCY LANDING - GREEN HYDRAULIC OVERHEAT ON APPROACH. REMOVED AND REPLACED LEFT ENGINE HYDRAULIC PUMP PER MAINTENANCE MANUAL 29-11-51. ALSO REPLACED CASE DRAIN FILTER ASSEMBLY PER MAINTENANCE MANUAL 29-11-43. LEAKED CHECKED, NO LEAKSSDR Z8GA042809Powerpack · malfunctionedLANDING GEAR FAILED TO LOWER NORMALLY ON APPROACH TO KODO. LANDING GEAR LOWERED VIA EMERGENCY GEAR EXTENSION PROCEDURE ACCORDING TO POH. REPLACED LANDING GEAR POWER PACK.SDR CA090430006Drive Shaft · broken(CAN) PUMP FAILED AT RUN-UP, MECHANICS REPLACED THE PUMP AND FOUND THE DRIVE SHAFT BROKEN.SDR AALA2009042000002Pump · inoperativeJFK - THE CREW REPORTED THAT THE AIRCRAFT HAD LOST THE YELLOW HYDRAULIC SYSTEM. EMERGENCY DECLARED LANDED JFK WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED YELLOW HYDRAULIC SYSTEM ENGINE DRIVEN PUMP ON NUMBER TWO ENGINE. SYSTEM GROUND CHECK NORSDR 2009FA0000313Pump · failedLOSS OF HYDR POWER WHILE IN FLIGHT. ALSO ROTOR TACH WENT TO ZERO. LOW ROTOR CAUTION LIGHT CAME ON AND HORN SOUNDED.SDR UALA2009041301062Pump · faultyCREW REPORT: CENTER ELECT 2 PUMP PRESS LIGHT ILLUMINATED. REPLACED PUMP ASSY AND PRESSURE AND CASE DRAIN FILTERS. LEAK AND OPS CHECK OKAY.SDR C2XA09CL040Pump · leakingCLE - FLIGHT 2690 THE CREW REPORTED, LOST ALL NR 2 HYDRAULIC SYSTEM FLUID IN FLIGHT. THE AIRCRAFT LANDED IN CLE WITHOUT FURTHER INCIDENT. MAINTENANCE INSPECTED AND REPLACED THE NR 2 ENGINE DRIVEN HYDRAULIC PUMP. OPERATIONAL CHECKS WERE GOOD.SDR DXTA2009041303600Pump · malfunctionedFL 400, PUMP 2 HYD NR 1 AMBER LIGHT ILLUMINATES. SYS PRESSURE/QTY 2990/80 PERCENT. LATER NOTICED QTY DROPPING & DIVERTED. UPON LANDING, SLOW GEAR OPS, MINIMAL NOSE WHEEL STEERING & AMBER "BRAKE" LIGHT ON. NR 1 SYS PRESSURE/QTY 1320/20 PERCENT. INSP FOUND LT BRSDR HALA2009040800133Pump · leakingETOPS SIGNIFICANT SYSTEM, AT GATE FOUND HYD LEAKING FROM LEFT ENGINE ISOLATED TO LEFT ENGINE DRIVEN PUMP. REMOVED AND REPLACED LEFT ENGINE DRIVEN PUMP PER MM TASK 29-11-05-404-024, OPS CHECK CARRIED OUT NORMAL. NO LEAKS OBSERVED.SDR U5QA06016Pump · failedPILOT REPORTED LT HYDRAULIC PRESSURE LIGHT CAME ON IN CRUISE. PRESSURE SLOWLY STARTED TO DROP. PILOT DECLARED EMERGENCY AND STARTED DESCENDING. LOWERED FLAPS AND GEAR VIA NORMAL EXTENSION. LANDED AT ATL WITHOUT INCIDENT.SDR UALA2009040600973Pump · failedB-ELEC PUMP OVHT DISPLAYED ON UPPER ECAM SCREEN. RTFL. REPLACED BLUE HYD PUMP AND CASE DRAIN FILTERS. LEAK CHECK OK.SDR DL75E090625Pressure Switch · inoperativeBOTH CTR HYD PRESSURE IND LIGHTS IN OVHD PANEL ILLUMINATED WITH PRESSURE APPLIED. CTR HYD PRESS READING ON EICAS NORMAL. WHEN CREW TOOK THE ACTIVE RUNWAY FOR T/O CTR PRESSURE WENT TO ZERO. REPLACED CENTER HYD PUMP C-1 PRESSURE SWITCH S10003 PER M/M. OPS CHSDR FDEA200904021179Pump · damagedYELLOW HYD SYSTEM RES OVHT. FOLLOWED ECAM & QRH PROCEDURES. YELLOW RES OVHT LIGHT EXTINGUISHED AFTER 45 MIN. EMERGENCY DECLARED FOR LANDING. EARLY ALERT MOCC-EWR MX. REMOVED YELLOW CASE DRAIN FILTER. FOUND FLUID DISCOLORED AND FILTER BADLY CONTAMINATED WISDR AALA2009033100004Pump · inoperativeCREW REPORTED LOSS OF RT HYDRAULIC SYSTEM. EMERGENCY DECLARED LANDED DFW WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED RT ENGINE DRIVEN PUMP ADN FILTERS. SECURED LOOSE B-NUT. SYSTEM GROUND CHECK NORMAL OPERATION. (CLOSED)SDR CA090407006O-Ring · split(CAN) BOTH HYDR LIGHTS CAME ON IN FLIGHT AND ACFT RETURNED TO BASE. MX FOUND THE LT HYDR PUMP PRESSURE FITTING LEAKING. THE FITTING WAS REMOVED AND AND THE O-RING WAS FOUND DAMAGED. O-RING REPLACED - SYS SERVICED AND RETURNED TO SERVICE.SDR NWAA09826623Pump · leakingENROUTE, THE NR 4 HYDRAULIC SYS LOST BOTH PRESSURE AND FLUID QUANTITY. THE FLIGHT CREW DECLARED AN EMERGENCY TO ALLOW FOR ALTERNATE GEAR EXTENSION OF THE WING GEAR. THE LANDING WAS UNEVENTFUL. MX FOUND THE NR 4 ENGINE DRIVEN HYD PUMP LEAKING FROM THE CASE DRSDR CA090413003Pump · unserviceable(CAN) HYD FEED BACK ON HYD TEST PRIOR TO FLIGHT . CHECK ALL SYS AND FLUID. FOUND METAL INSIDE FILTER. REPLACED HYDR PUMP WITH SERVICEABLE PUMP. HOLD PUMP AS BEEN INSPECTED AND GEAR FOUND TO BE WORN INSIDE THE PUMP. CHIP DETECTOR AS NOT COLLECTED ANY METAL.SDR AALA2009032000004Motor · inoperativeBOS - LEADING EDGE SLAT DISAGREE INDICATION. EMERGENCY DECLARED ON APPROACH, LANDED BOS WITHOUT INCIDENT. AIRCRAFT REMOVED FROM SERVICE. REPLACED HYDRAULIC MOTOR AND LINES. SYSTEM GROUND CHECK NORMAL OPERATION.SDR UALA2009032000852Pump · faultyEDP (ENGINE DRIVEN PUMP) HYD PWR POS 1O1=L,O2=R) EDP HYD LOW PRESS LGT ILLUM. EICAS MSG DISPLAYED (L,R) HYD PRIM PUMP. EICAS MSG (L,R) HYD SYS MAINT (WAS, WAS NOT) DISPLAYED. REPLACED NR 1 ENGINE HYDRAULIC PUMP.SDR DL75E090447Pump · leakingDURING FLT LEFT HYD QTY AT .24 WITH LEFT QTY AND LEFT ENG DRIVEN PUMP EICAS MSGS. FOUND LT EDP LEAKING ON CASE PUMP BODY. WHEN PUMP REMOVED FO DRIVE SHAFT SHEARED. REPLACED LT EDP IAW AMM 29-11-05-404. REPLACED LT CASE DRAIN AND PRESSURE FILTERS ALL OK EDPSDR DL76L090446Pump · leakingCENTER HYDRAULIC SYSTEM QTY LOW, SYS QTY AT .21. FOUND C2 ELEC PUMP TO BE LEAKING. REPLACED C2 ELECTRIC PUMP. SERVICED CENTER HYD LEAK AND OPN CHECK GOOD.SDR FDEA200903170939Pump · leakingATB - TOTAL LOSS OF GREEN HYD FLUID DURING CLIMB-OUT, MANUAL GEAR EXTRACTION GREEN SYSTEM HYD. R & R HOSE AND NR 1 AND 2 ENG DRIVEN HYD PUMPS AND FILTERS PER MM 29-11-32-4. SERVICED GREEN SYSTEM, OPERATED FLIGHT CONTROLS THROUGH SEVERAL CYCLES, LEAK CHECK
Back to JASC 2913