What it covers
The manually actuated pump for emergency system pressure. Typical parts are handle, lever, seal, etc.
Service difficulty reports · 22
Reports filed under 2914, newest first.
| 1998 | 1 |
|---|---|
| 2000 | 3 |
| 2003 | 1 |
| 2004 | 7 |
| 2005 | 4 |
| 2011 | 1 |
| 2013 | 1 |
| 2018 | 1 |
| 2021 | 1 |
| 2022 | 1 |
| 2023 | 1 |
SDR ASAA2023123147115Pump · failedCREW REPORTS SYS A HYD PRESSURE SHOWS 370 PSI WITH PUMP SWITCH ON. GROUNDED - YES. REMOVED AND REPLACED SYSTEM A MODULAR ASSY PER AMM 29-11-71. VERIFIED NO PRESSURE DROPPED WITH HYDRAULIC LOAD. PERFORMED LEAK CHECK. NO DEFECTS NOTED. LEAK CHECK GOOD. FINAL SYSSDR CALA2022082902216None · noneHYD Y RSVR LO LVL INFLIGHT. FLASHED SEVERAL TIMES AT CRUISE. MSG RETURNED AND INITIAL T/S FOUND HYD RES LEVEL WITHIN LIMITS, POST FLIGHT STAYED ON. REPLACED YELLOW RESERVOIR LOW LIMIT SWITCH. OPS CK NORMAL. NO LEAKS.SDR CALA2021112902196Pressure Switch · contaminatedG ENG 1 PUMP LO PR DISPLAYED ON UPPER ECAM SCREEN. - HYD SMITH CONTACT TOMC 847-700-9980 OK TO UNLOCK TOMC SMITH CAPTAIN REPORTED THAT AT FL10 RECEIVED A E1 GREEN SYSTEM LO PR PLEASE PERFORM TSM 29-11-00-810-805-A....CONTACT TOMC MESSAGE FOLLOWED BY THE PTU EN
See all 22 reports