Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR AALA201809109023Ballast · inoperativeCABIN ODOR. THE AIRCRAFT WAS GROUNDED. ACCOMPLISHED JC26L00021001. REPLACED ROW 17R SIDEWALL LIGHT BALLAST. NO ELECTRIC ODOR NOTED. OK FOR SERVICE.SDR QXEA2018081300287Lamp · inoperativeEMERGENCY LIGHT SWITCH INSIDE THE MAIN CABIN DOOR DOES NOT ILLUMINATE. REMOVED FROM SERVICE. REPLACED THE LAMPS IN THE SWITCH. SWITCH ILLUMINATES NORMALLY. RETURNED TO SERVICE.SDR ALGA2018053145747Cover · missingRIGHT POSITION LIGHT COVER WAS DISCOVERED MISSING, DURING POST FLIGHT WALK AROUND.SDR 7C7A2018052400444Relay · hotELECTRICAL SMELL COMING FROM CLOSET IN CABIN.SDR 201805220000160Inverter · failedFLIGHT ATTENDANT REPORTED ELECTRICAL BURNING ODOR IN CABIN. FLIGHT CREW CONFIRMED NO SMOKE WAS PRESENT IN CABIN. LANDED AND WAS INSPECTED ON GROUND BY THE FIRE DEPARTMENT FOR EVIDENCE OF SMOKE OR BURNING. NONE DETECTED, MAINTENANCE SURVEYED AIRCRAFT AT BASE, SDR ALGA2018053145639Cover · missingPOSITION LIGHT COVER WAS DISCOVERED MISSING DURING POST FLIGHT WALK AROUND.SDR YENA201802260110Bulb · brokenDURING APPROACH, A STRONG ODOR IN THE COCKPIT AND CABIN, OF ELECTRICAL ODOR, LIKE A BALLAST IN A FLUORESCENT LIGHT BURNING OUT. TURNED OFF THE COMMERCIAL BUTTON ON OVHD ELEC PANEL AND THE AFT AVIONICS COMP. SWITCH. THE ODOR SUBSIDED BUT CHANGED TO THE ODORSDR HNAA2018022600042Light · inoperativeIN CRUISE FLT AT ABOUT 8K, FUMES IN CABIN AROUND ROW 6, FLT ATTENDENT TURNED CABIN LIGHTS OFF, NO CHANGE. SELECTED NR 2 BLEED AND NR 1 PACK OFF SMELL DISAPATED WHILE AIRCRAFT WAS DEPRESSURIZING. FOUND O/H LIGHT AT ROW 8A/C BURNT OUT. INSP LIGHT FIXTURE, NO DEFSDR CALA2018021600661Lens · missingEMERGENCY LIGHT LENS MISSING AT SEAT 20C. REPLACED THE LENS.SDR CALA2018021200612Lens · missingMISSING EMERGENCY LIGHT LENS AFT SIDE WALL OF FIRST CLASS CLOSET. INSTALLED THE LENSSDR A6WA201845599None · noneRIGHT SIDE EMERG EXIT ROW 8 BOTTOM EMERG LIGHT INOP. OPERATED EMERGENCY LIGHTS MANY TIMES OP CK OK AT THIS TIME.SDR CALA2017122104565Fuse · inoperativeEMERGENCY LIGHT ON SEAT 21C MISSING. TROUBLESHOT IAW WDM 33-51-21. EMERGENCY POWER SUPPLY M1694 NOT OUTPUTING POWER ON OUTPUT 11. IAW SSM 33-51-13 PAGE 101, REPLACED THE 5 AMP FUSE FOR PIN 13,14 ON POWER SUPPLY OPS CHECKED OK , IAW AMM 33-51-13SDR CALA2017120304301Director · malfunctionedEMERG EXIT LIGHTS ON. RESEAT CIDS DIRECTOR SYST OP OKSDR CALA2017120104241Socket · brokenELECTRICAL ODOR WAS REPORTED BY THE FA''S STATIONED IN THE FWD & MID GALLEY''S DURING T/O. THE FA IN THE FWD GALLEY WAS REPORTED SOME OVERHEAD & SIDEWALL LIGHTING FLICKERING 30 SECS AFTER POWER TRANSFER IN THE FWD GALLEY. THE ODOR WAS THE ODOR WAS SMELT AS FASDR RAIA201711290001Bulb · inoperativeRT AFT WING/FUSELAGE FAIRING EXTERIOR LIGHT (#6) INOP. R & R RT AFT WING/FUSELAGE FAIRING EXTERIOR LIGHT BULB (#6), OPS CHECK GOOD.SDR CALA2017111204047Battery · dischargedEMERGENCY LIGHTING POWER SUPPLY BATT FAIL. R&R BATT. OP-CHECK GOOD. AMM 33-51-000-002-A, AMM 33-51-38-400-002-A.SDR CALA2017103003843Module · defective36A SLIDE ROW LIGHT BLINKS. REPLACED LED MODULE AT WINDOW/SIDEWALL 36A, OPS CKS GOOD. REF AM M33-21-00.SDR CALA2017102003726Battery · dischargedFOUND BATTERY A T POSITION M1668 JUST FWD OF LT EMERGENCY EXIT BEHIND DADO PANEL TO BE BAD. REPLACED BATTERY OP CKS OK REF AMM33-00-00.SDR CALA2017102003697Ballast · odorSIGN OF ELECTRICAL SMOKE ODOR IN AFT GALLEY AREA REPORTED BY FLIGHT ATT...CREW TURNED OFF GALLEY POWER AND NOTICED SMOKE HAS DISSIPATED...ACCOMPLISH SMOKE- FUMES CONDITION INSPECTION PER AMM05-5 1-50-201...FOUND BAD BALLAST AND REPLACED. PERFORMED SMOKE ODOR SDR 29GA2017101600001Bulb · inoperativeFA PUSH BUTTON LIGHT BULB NOT ILLUMINATING. REPLACED THE BULB, OPS CHECKED SATISFACTORY.SDR ASAA2017100122094Light · intermittentPRESSURIZATION CONTROL PANEL BACKLIGHTING INOPERATIVE. PRESSURIZATION OPERATES NORMALLY. ACFT GROUNDED. PERFORMED FIM 21-31, TASK 803, STEP G. LIGHTING ON PANEL RETURNED TO NORMAL. INTERMITTENT FAULT AND SYSTEM IS SERVICEABLE IAW FIM.SDR HNAA2017100200341Unknown · unknownWITH THE NR 2 ENGINE RUNNING, AND GPU DISCONNECTED, ALL ACFT LIGHTS EXTINGUISH. NR 2 DC GENERATOR DOES SHOW LOAD. STARTED THE NR 1 ENGINE, FLT DECK LIGHTS ILLUMINATED AND CABIN EXIT LIGHTS WOULD NOT TURN ON AND FA UNABLE TO TURN ON EMERGENCY LIGHTS. EMERGENCSDR A6WA201745303None · none4214 EMERGENCY TRACK LIGHTS OUT FROM ROW 2 TO 5. INSPECTED FLOOR TRACK LIGHTING IAW AMM 33-51-01, NO
DEFECTS NOTED AND
OPS CHECK GOOD AT THIS TIMESDR A6WA201745292None · none
4921 EMERGENCY FLOOR LIGHTS AT TOW 7 AND 8 NOT ILLUMINATING OPS CHECK GOOD IAW AMM 33-51-00
SDR A6WA201745274None · none4261 FLOOR PATH EMERGENCY LIGHTS WILL NOT ILLUMINATE FROM ROW 8 TO 13 CW OP TEST OF EMERG LIGHTS IAW AMM
SUPP 16-374A
AND VISUAL INSP IAW AMM 33-51-01 ACFT GOOD FOR SERVICESDR 2DYA20170811001Light · inoperativeDURING SERVICE CHECK, FOUND THE RT LAVATORY CROSS AISLE LIGHT L310 INOPERATIVE.SDR CALA2017071002178Power Supply · malfunctionedEPSU LEFT FAULTS DURING EMERGENCY LIGHT TEST AT CIDS PANEL RESET EPSU CIDS SYSTEM PER TSM33-51-38. GROUND BIT TEST NORMAL REF AMM33-51-00. OPS CHECK OKSDR CALA2017060501699Lens · brokenDURING WALKAROUND FOUND EMERGENCY EXIT LIGHT LENS AT LEFT EMERGENCY EXIT BROKEN. REPLACED EMERGENCY EXIT LIGHT LENS IAW AMM 33-51-06. OK TO CONTINUE.SDR CALA2017060201657Switch · failedFUMES IN COCKPIT DURING DESCENT. SMELLED LIKE ELECTRICAL FIRE. TRACED FUMES TO A FAULTY LEFT TURNOFF LIGHT SWITCH. REMOVED AND REPLACED PANEL ASSEMBLY AND TESTED IAW AMM 33-42-00-715-030. ALL OPS NOW NORMAL. R & R OF LIGHT ASSEMBLY PANEL.SDR CALA2017051501436Socket · damagedCREW REPORTS ELECTRICAL ODOR IN FLIGHT ATTENDANT REST AREA. NO VISIBLE SMOKE SEEN JUST THE ODOR. FOUND LAMP SOCKET DAMAGED AT AFT GALLEY 422 WORK LIGHT. REPLACED LIGHT ASSEMBLY, OPS CHK OK.SDR CALA2017050501230Battery · dischargedEMER LT M33094 FOUND BATTERY LOW. R1 DOOR EMERGENCY LIGHT BATTERY PACK M33094 REPLACED AND OPERATIONAL TESTED NORMAL AS PER AMM 33-51-06.SDR CALA2017020300256Light · malfunctionedDOOR 2L EMERGENCY LIGHT DID NOT COME ON DURING OPERATIONAL CHECK . FOUND DOOR 2L EMERGENCY LIGHT TO OPS NORMAL.SDR CALA2017013000212Light · inoperativeEMER EXIT LIGHTS NOT ARMED LIGHT DOES NOT ILLUMINATE. RELAMPED OPS CHECK GOODSDR CALA2017012300167Light · intermittentL1 DOOR EMERGENCY EXIT LIGHT INTERMITTENT. LIGHT OPS CHECKS OK AND NORMALSDR CALA2016112500970Battery Pack · faultedFWD EPSU FAULT LIGHT DURING TEST REPLACED EMERGENCY BATTERY PER AMM 33-51-38. NOW OKSDR SIMA20161118002Bulb · inoperativeRIGHT WING INSPECTION LIGHT INOPERATIVE. REPLACED THE BULB IAW AMM 33-50-10-04, OPS CHECKED GOOD.SDR CALA2016111400888Battery Pack · unserviceableEMERGENCY EXIT LIGHT BATTERY PACK AT STA 952 LT IS BAD AND NEEDS TO BE REPLACED. REMOVED OLD AND INSTALLED SERVICEABLE BATTERY PACK AT STA 952 LT IAW AMM 33-51-06. OP CHK GOOD.SDR CALA2016070195492Light · shortedBURNING ODOR BETWEEN DOORS 3 AND 4R WHEN WALKING THRU THE CABIN. PERFORMED A WALK THROUGH ENTIRE CABIN, ODOR IS STRONGEST AT 51JH ALONG SIDEWALL AREA ACP CABIN TEST, FOUND OEU 3-3-7 HAD A SHORT CIRCUIT. MESSAGE 23-03485. M23411 LOCATION RIGHT PSU PANEL ROSDR UIEA2016060200394Battery Pack · inoperativeLEFT A ZONE EMERGENCY LIGHTS INOPERATIVE FROM BULLNOSE AFT. R & R M735 BATTERY ASSEMBLY IAW AMM TASK 33-51-07-422-010 STEPS 5A TO 5D.SDR R61A201604250287Handset · intermittentCREW REPORTED THAT THE AFT F/T RAINBOW LIGHT WAS FLICKERING.SDR CALA2016032100181Battery Pack · dischargedRIGHT DOOR 1 EMER LIGHT FOUND DIM. RT DOOR 1 BATTERY PACK M33094 REPLACED & TESTED NORMAL IAW AMM 33-51-06.SDR 5SWS2015FA0000643Light · inoperativeBOTH OUT, LED STRIPS INOPERATIVE.SDR CALA2015101400846Battery Pack · dischargedSEAT ROW 26 - 32, EMER PATH LIGHTING INOPERATIVE. R & R BATTERY PACK AT SEAT ROW 27L IAW AMM 33-51-06-960-805, SUB TASKS 960-005, 960-006 & 710-004. OPERATIONS CHECKED GOOD.SDR CA151013006Panel · burned(CAN) AFTER STARTUP, THE CREW NOTICED WHAT SEEMED TO BE ELECTRICAL BURNING ODOR COMING FROM OVERHEAD AIR GASPER. THE CREW AGREED ON CALLING FOR TAXI TO SEE IF THE ODOR WOULD DISAPPEAR. PRIOR TO LEAVING THE GATE, AS AN EXTENDED PRECAUTION THE CREW REVIEWED THSDR AALA20150817009Light · damagedL4 DOOR AFT VERTICAL EMER EXIT LIGHT FOUND DAMAGED. L4 DOOR AFT VERTICAL EMER EXIT LIGHT REPLACED. OPERATIONS CHECK WAS FOUND NORMAL IAW AMM 33-51-01.SDR CALA2015070900556Ballast · malfunctionedSHORTLY AFTER TAKEOFF & JUST PRIOR TO DESCENT, NOTICED A BURNING RUBBER SMELL ON ACFT LT ROWS 32 - 36. FOUND BALLAST AT 43 JKL SIDE WALL BURNT OUT. R & R BALLAST & BULB. OPERATIONS CHECKED GOOD, NO OTHER FAULT NOTED.SDR XGN2015F00000Switch · inoperativeSWITCH FAILED.SDR CA150612004Light · shorted(CAN) THE AIRSTAIR LIGHT, 3RD FROM THE TOP WAS REPORTED AS NOT WORKING. MAINTENANCE INVESTIGATION FOUND THE LIGHT ASSEMBLY SHORTED & BURNT. THE LIGHT ASSEMBLY WAS REPLACED & THE AIRCRAFT RETURNED TO SERVICE. AIRSTAIR LIGHT PN ELCS-1001-001.SDR CALA2015010900021Fuse · failedRIGHT SIDE OVERWING ESCAPE GND ILLUMINATION LIGHT INOPERATIVE. REPLACED EMER EXIT LIGHT BATTERY PACK M1670 FUSE & OPERATIONS CHECKS GOOD IAW AMM 33-51-06-960-804.SDR CALA2014100901334Light · inoperativeSUPPORT TASK RT OVERWING EXIT LIGHTS WILL NOT ILLUMINATE. INTERIOR AFT R & R RT INTERIOR EMER OVERWING EXIT AFT LIGHT BULB IAW AMM 33-51-00. OPERATIONS CHECKED GOOD.
Back to JASC 3300