Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3300' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR CALA2014090501209Light · inoperativeLEFT ROW 20 EMER AREA LIGHT IS INOPERATIVE. LAMPED ROW 20 LT EMER AREA LIGHT IAW SWPM 20-6 4-17. OPERATIONS CHECKED OK IAW AMM 33-51-00.SDR FDEA201408062101Light · inoperative1L DOOR LIGHT DOES NOT TEST. CHANGED BATTERIES IN L1 DOOR IAW SMP.SDR CALA2014080401078Battery Pack · failedFIRST CLASS BULLNOSE EMER LIGHTS BATTERY PACK FAILS CAPACITY CHECK. R & R BATTERY PACK ON M1674 POWER SUPPLY IAW AMM 35-51-06-960-805. OPERATIONS CHECKED GOOD IAW AMM 33-5 1-06-960-805.SDR SWIA201438607Cover · missingMID CABIN EXIT ROW SIGN FOUR FACING ANNUNCIATOR LIGHTS MISSING COLORED COVERS. REPLACED MID CABIN EXIT ROW REAR FACING ANNUNCIATOR LIGHT IAW AMM.SDR SWIA201438028Light · crackedPAX DOOR PULL IN LEVER EMERGENCY EXIT BETAS LIGHT IS CRACKED. C-CHECK, R & R EMERGENCY EXIT BETA LIGHT, IAW SRM.SDR ASOA2014042410388Light · inoperativeTRACK LIGHTING FADED, HAS NO PROPERTIES, FROM LT BS 357-409. R & R TRACK LIGHTING IAW AMM 33-51-01-400-801.SDR ASAA2013121812166Light · inoperativeVNAV BUTTON LIGHT ON MCP INOPERATIVE. ACFT GROUNDED. REPLACED THE A/P MCP IAW MM 22-11-34-400-801. OPS CK GOOD IAW MM 22-11-34-740. PERFORMED THE DFGS LRU INTERFACE TEST FOR MCP IAW MM22-11-34/501, TEST GROUP 32, PASSED. PERFORMED LAND VERIFY TEST IAW MM 2SDR DALA13054143218Relay · malfunctionedDOOR LIGHTS ON AFTER GEAR UP. CABIN LIGHT UNCONTROLLABLE FROM F/A PANEL. R & R RELAY 8WL IAW ASM 33-51. OPS TESTED GOOD, OK FOR CONTINUED SERVICE.SDR CALA2013093000707Battery Pack · dischargedEMERGENCY LIGHTS UNDER OVERHEAD BIN 31 & 34 DEF WILL NOT ILLUMINATE. REPLACED POWER SUPPLY BATTERY PACK LOCATED ABOVE CEILING AT R2 DOOR IAW MM. 33-51-06. OPERATIONS CHECKED OKAY.SDR SWIA201334440Light · inoperativeEMERGENCY LIGHT POD IS BURNED OUT. FLT#5221 RELAMPED.SDR N6WA2013071803Light · looseLUMINESCENT STRIP LOOSE AT ROW 11, RESECURED LUMINESCENT STRIP IAW AMM 51-22-00. OK FOR SERVICE AT THIS TIME.SDR SWAA2013060316718Ballast · faultyDECLARED EMERGENCY, F/A AND PASSENGERS REPORT ACRID SMELL (ELECTRICAL) AND SMOKE IN CABIN. R & R LT EMERGENCY EXIT DOOR BALLAST IAW MM.SDR SWIA201333354Ballast · faultyELECTRIC SMOKE IN CABIN. (FLT 5584) REMOVED AND REPLACED BURNED CEILING LIGHT BALLAST ON AFT RIGHT SIDE.SDR AALA20130319017Lens · missingROW 20C ESCAPE PATH LIGHT MISSING LENS. REPLACED LENS FOR ROW 20C ESCAPE PATH LIGHT. OPS CHECK NORMAL.SDR VNAA2013030100002Light · smokeCREW REPORTED A SMOKE TOILET MESSAGE WITH SMOKE IN CABIN. MAINTENANCE TROUBLESHOT, DETERMINED THE LIGHT UNIT CAUSED SMOKE, SECURED, AND DEFERED THE LAVATORY LIGHT UNIT. PARTS ARE ON ORDER. SUPPLEMENTAL SDR WILL BE SUBMITTED WHEN REPAIRED. AIRCRAFT WAS RELESDR SWAA2013030113197Ballast · overheatedPUT RIGHT PACK ON FOR AIR AND IMMEDIATELY SMELLED AN ODOR SIMILAR TO A BLOWN OUT MATCH. GASPER FAN AND RECIRC FAN SWITCHES WERE BOTH IN THE OFF POSITION. REMOVED AND REPLACED CEILING LIGHT ASSY BALLAST AT ROW 14 TO 16 RIGHT SIDE DUE TO EXCESS / BALLAST HEAT SDR HNAA2013020400032Bulb · failedAFTER F/A'S PA ANNOUNCEMENT DURING TAXI OUT, EMERGENCY SWITCH BACK LIGHT AND PA SWITCH BACK LIGHT WERE FOUND TO BE INOP WITH ELECTRICAL SMELL FROM PANEL AREA. ALL SWITCH FUNCTION NORMAL. RELAMP BACK LIGHT BULBS AND INSPECTED F/A'S CONTROL PANEL. NO SIGNS OF SDR WX0A071456Ballast · burnedSMOKE IN THE CABIN REPORTED. DISCOVERED SIDEWALL LIGHT HAD BURNT BALLAST. DISCONNECTED BALLAST.SDR SWIA201232405Light · smokeRIGHT AFTER DEPARTURE, SMOKE WAS PRESENT IN THE CABIN ALONG WITH AN ELECTRICAL SMELL. (FLT 6532) REPLACED THE CEILING LIGHT ASSEMBLY AT ROW 8 CD.SDR SWIA201232351Light · inoperativeSECOND TO LAST CEILING OVERHEAD LIGHT IS BURNED OUT. (FLT#4645) RELAMPED OVERHEAD LIGHT.SDR SWIA201232364Light · inoperativeONE RED FORWARD FLOOR LIGHT INOPERATIVE. (FLT 5473) REPLACED RED FLOOR EMERGENCY LIGHT AT FORWARD END NEAR MAIN CABIN DOOR.SDR SWIA201232324Light · failedSMELLED ELECTRICAL SMOKE COURTESY LIGHT CIRCUIT BREAKER OPEN. (FLT 7799) REPLACED BULB.SDR UALA2012112606753Light · unsecureEXIT LIGHT FWD LAV WALL 1R FALLING OFF. SECURED LIGHT FITTING.SDR SWIA201232220Light · inoperativeONE WHITE LIGHT ON THE EMERGENCY FLOOR ILLUMINATION LIGHTING IS BURNED OUT. (FLT 5312) RELAMPED EMERGENCY LIGHTING.SDR UALA2012110706397Light · brokenEXIT LIGHTING AT 1R BROKEN. REPAIRED AND SECURED LIGHTT IN PLACE, OPS CHECKED OK FOR FUNCTION.SDR UALA2012110506356Light · improper partPER FCD#3330-01031 FOUND INCORRECT HALOGEN BULBS P/N 9203 INSTALLED AT ALL 4 POSITIONS AND MAINT TEXT: MANDATORY PLACARDS MISSING ABOVE LLAR STA1466 AND STA 1522. ACP FCD 330-01031 PER EG 7521. RELAMPED BULBS AND ADDED PLACARDS.SDR UALA2012101905982Lens · activatedFOUND 10 SMALL LIGHT LENS COVERS STAINED YELLOW THRU OUT CABIN. INSTALLED LIGHT LENS COVERS.SDR UALA2012101905981Lens · defectiveFOUND 40 LENS COVERS THRU OUT CABIN STAINED YELLOW AND REQUIRE REPLACEMENT PCN 564-1007. INSTALLED LENS COVERS THRU OUT COACH. REQUIRES RETAINERS ON LEN COVERS.SDR SWIA201231627Light · burnedELECTRICAL SMELL IN THE COCKPIT. (FLT 5614) FOUND DOME LIGHT BETWEEN GALLEY AND FLIGHT DECK TO BE BURNED. REPLACED DOME LIGHT ASSEMBLY IN REFERENCE TO AMM.SDR SWIA201231448Ballast · malfunctionedSTRONG BURNING SMELL NOTICED IN FRONT SECTION OF PAX CABIN. (FLT 6424) REPLACED BALLAST AT STORAGE BIN 4AB.SDR GZFR201208030001Control Module · burnedAIRLINE SENT CONTROL MODULE TO REPAIR STATION FOR REPAIR. PANEL IS BADLY BURNED AND EITHER WAS THE CAUSE OF A FIRE OR WAS BURNED WHEN AN ADJACENT PANEL CAUGHT ON FIRE.SDR SWIA201230918Light · inoperativeOVERHEAD EMERGENCY LIGHT AT ROW 9 IS OUT. (FLT 6752) RELAMPED EMERGENCY LIGHT.SDR SWIA201230510Light · defectiveOVERHEAD STRIP LIGHTING ABOVE SEAT 5A BEGAN EMITTING SMOKE. (FLT 5388) REPLACED LIGHTING ASSEMBLY AT SEAT 5A.SDR 2012FA0000191Control Panel · unserviceableON OTBD FLIGHT 30 ALPHA PANEL PRODUCED AN ELECTRICAL CHEMICAL SMELL, PERFORMED INSP ON PANEL, SN PO29433 AND FOUND ANTI-COLLISION CIRCUIT INOPERTIVE. REPLACED 30 ALPHA PANEL WITH SN PO15420.SDR SWIA201230103Light · inoperativeNR 2 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4786) RELAMPED EMERGENCY LIGHT.SDR SWIA201229790Light · shortedSMOKE REPORTED IN CABIN ABOVE ROW 4AB. (FLT 6466) REPLACED SIDEWALL LIGHT ASSEMBLIES AT ROW 4AB FOR A SHORT CIRCUIT.SDR SWIA201229754Fixture · defectiveDETECTED ODOR OF ELECTRICAL BURNING BETWEEN ROW 6 AND 9. (FLT 5479) REPLACED LOWER ASSEMBLY LIGHT FIXTURE AT 7A.SDR SWIA201229551Light · inoperativeNR 3 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 5363) RELAMPED EMERGENCY LIGHT.SDR SWIA201229534Light · inoperativeEMERGENCY LIGHT OVER ROW 6 IS OUT. (FLT 4536) RELAMPED EMERGENCY LIGHT.SDR PNSA111001Ballast · unserviceableLAV SMOKE LIGHT ILLUMINATED. FLIGHT ATTENDANT VERIFIED SMOKE SMELL. RETURNED TO BASE.SDR SWIA201127075Light · inoperativeNR 4 OVERHEAD EMERGENCY LIGHT IS OUT. (FLT 4453) RELAMPED EMERGENCY LIGHT.SDR UALA2011060802823Control Panel · faultyBURNING SMELL EMANATING FROM THROTTLE QUADRANT AND LEFT SIDE RADIOHEAD. SAMC TEXT: CHECK 105VU AND 106VU PANELS FOR EVIDENCE OF SMOKE ODOR BEFORE CLEARING THIS ITEM. ALSO, PERFORM GENERAL VISUAL INSPECTION OF 95VU RACK AREA FOR ANY SOURCE OF SMOKE SMELL. CASDR C2XA11RI062Contactor · burnedFLIGHT 3081 - EWR - FLIGHT CREW REPORTED STRONG SMELL BURNING RUBBER IN FRONT OF ACFT AFTER LANDING. EWR MX REMOVED AND REPLACED CONTACTOR K0236 AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE. (SUPPLEMENTAL CHANGED DIFF SDR CALA2011041500290Light · inoperativeR4 EMERGENCY EXT LIGHT INOP. RELAMPED, CHECKS GOOD.SDR CALA2011041500289Battery Pack · weakTHE 2R EMERGENCY LIGHTS WEAK. REPLACED BATTERY PACK; LTS CHECK NORMAL.SDR ASOA201100529Light · unserviceablePAX DOOR INTERIOR HANDLE "PULL TO EXIT" SIGN WORN. INSTALLED NEW SERVICEABLE PAX DOOR "PULL TO EXIT" BETA LIGHT IAW AMM 33-51-09-400-801. FUNC TEST GOOD IAW AMM 33-51-09-720-801.SDR CALA2010111900586Wire Harness · brokenSUPPORT TASK - EMERGENCY LIGHT WIRE BROKEN AT SEAT ROW 30, O/B LEG. REMOVED AND REPLACED EMERGENCY LIGHT WIRE HARNESS AT SEAT ROW 30 LT IAW CMM 25-25-99. OPS CHECK WILL BE PERFORMED ON EA 4420- 01009 REV E OPS 36 STEP 2A. WORK PERFORMED BY SX992.SDR CALA2010091700436Light · brokenGALLEY NR 2 A/C RIGHT ESCAPE PATH LIGHT BROKEN. REMOVED AND REPLACED GALLEY NR 2 A/C RIGHT ESCAPE PATH LIGHT IAW AMM 33-51-10 / SWP 20-10-13 OPS TEST OK.SDR 2010FA0000824Element · defectiveINSTALLED A NEW LAMP PN Q4581 ON ACFT. ACFT MADE (1) LANDING AFTER THE INSTALLATION AND THE ELEMENT FELL OUT OF ITS SOLDERED LOCATION INSIDE THE GLOBE. PROBABLE CAUSE: SOLDERED JOINT DEFECTIVE.SDR HALA2010071800304Attach Fitting · shearedOPEN - FOUND DURING ETOPS CHECK, IN THE RIGHT GEAR WELL - WIRING HARNESS RACEWAY OUTBOARD ATTACH POINT SHEARED OFF. REMOVED RT WHEEL WELL ELECTRICAL COVER. REPAIRED ELECTICAL COVER IAW HAL M105, R0059, INSTALLED RT WHEELWELL ELECTRICAL COVER AS REQ.
Back to JASC 3300