SDR C2XA10RI077Light · defectiveFLIGHT 2076 - EWR - FLIGHT CREW REPORTED BURN SMELL AT ROW 12A. EWR MX REMOVED AND REPLACED LIGHT ASSY AT ROW 12A AND PERFORMED OPERATIONAL CHECK SUCCESSFULLY. ACFT WAS APPROVED TO RETURN TO SERVICE.SDR SIMA201015202Ballast · malfunctionedON FLIGHT 4340 DURING TAXI THE CREW REPORTED NOTICING ELECTRICAL FUME ODORS IN GALLEY ROW AREA. THE AIRCRAFT WAS REMOVED FROM SERVICE. REMOVED AND REPLACED BALLASTS (BOTH) IN GALLEY IAW EMB-140 CMM 25-28-24. THE OPERATIONAL CHECK WAS GOOD. THE AIRCRAFT WASSDR C2XA10IA122Ballast · overheatedIAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED A BURNING SMELL AT ROW 4. MAINTENANCE INSPECTED THE AIRCRAFT AND REMOVED AND REPLACED CEILING LIGHT BALLAST, OPERATIONALLY TESTED WITH NO DEFECTS. THE AIRCRAFT WAS APPROVED OF RETURN TO SERVICE.SDR C2XA10IA120Ballast · overheatedIAH - DURING PREFLIGHT INSPECTION THE CREW REPORTED A HOT ELECTRICAL SMELL IN THE AREA OF SEAT 1A. MAINTENANCE REMOVED AND REPLACED THE BALLAST 2A, OPERATIONALLY TESTED WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR C2XA10IA105Ballast · overheatedIAH - DURING MAINTENANCE INSPECTION A BURNING SMELL WAS NOTICED AT SEAT 1A. MAINTENANCE REMOVED AND REPLACED THE LIGHTING BALLAST ABOVE SEAT 1A, OPERATIONALLY CHECKED THE LIGHTING WITH NO DEFECTS NOTED, AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.SDR FDKA2009092900181Module · malfunctionedFRL FLT 6210 CVG-HTS. ELECTRICAL FUMES AT GALLEY AREA WITH GROUND POWER UNIT HOOKED UP. MX REMOVED AND REPLACED LIGHT MODULE ASSY.SDR RMXA3144060309Light · burnedPILOT DEPARTED AND WAS ENROUTE WHEN A BURNING ODOR BECAME EVIDENT IN THE COCKPIT AND THEN FOLLOWED BY VISIBLE SMOKE COMING FROM THE LT SIDE OF THE INSTRUMENT CENTER CONSOLE. PILOT INITIATED EMERGENCY PROCEDURES AND LANDED AT A SUITABLE LZ WITHOUT INCIDENT. UPOSDR 2009FA0000694Holder · failedWHILE TROUBLESHOOTING A PULSE LIGHT SYS PROBLEM ON OUR ACFT, FOUND AN ISSUE INVOLVING 2 IN-LINE FUSE HOLDERS WHICH WERE INSTALLED IN COMPLIANCE WITH MANDATORY SB 33-3682 (RE-ACTIVATION OF PULSE LIGHT SYS). THESE 2 FUSE HOLDERS (PN 155020A) ARE IN-LINE WITH THSDR CALA0800322Fuse · blownPATH WAY AISLE LIGHT INOP 3D AND ROWS 29 THROUGH 37 AND 20/21/22 D FOUND FUSES AT BATTERY POWER SUPPLY BURNED AND CONNECTIONS PLUGS LOOSE AT SEATS 29 TO 37.SDR M7K2008F00097Potentiometer · intermittentAT FULL BRIGHTNESS ADJUSTMENT ALL CONTROLLED LIGHTING FLICKERS ON AND OFF INTERMITTENTLY. REPLACEMENT WITH NEW PART CORRECTED THE DEFECT. (K)SDR SSHA118378Light · smokePOWERED UP AND BOX STARTED TO SMOKE.SDR 0700567Battery Pack · malfunctionedEMERGENCY BATTERY PACK BAD ROW 26L AND 21R. REPLACED BATTERY PACK PER CARD 29-3350-1-9100.SDR 1212Battery Pack · damagedEMERGENCY LIGHTING BATTERY PACK UNIT FOUND DAMAGED DURING CAP CHECK. BATTERY AND TRAY NEED TO BE REPLACED. BATTERY PACK (P/N 301-1180) AND TRAY (301-1066) WERE REMOVED AND REPLACED IN ACCORDANCE WITH CMM 33-51-21.
SDR 1217Battery Pack · defectiveEMERGENCY LIGHTING BATTERY PACK UNIT FOUND DEFECTIVE DURING CAP CHECK. BATTERY PACK UNIT REMOVED AND REPLACED PER CMM 33-51-21.SDR M7K2008F00096Light · unknownTHIS LIGHT ASSY HAS BEEN FAIRLY RELIABLE BUT IS A LITTLE DIFFICULT TO WORK ON REQUIRING PIN EXTRACTION TOOLING TO TROUBLESHOOT OR REPLACE. THE TYPICAL FAILURE IS INSIDE THE SEALED UNIT. THE QUALITY OF CONSTRUCTION IS EXCELLENT. (K)SDR DL777070672Switch · defectiveUNUSUALLY STRONG ODOR NOTED IN MAIN E/E COMPARTMENT. COULD NOT POSITIVELY IDENTIFY NATURE OF ODOR. PERFORMED INSP OF E/E ELECTRICAL COMPONENTS AND WIRING. NO TROUBLE FOUND. ALL C/B-S IN. INSPECT FWD CARGO BIN. ALL OKAY. ODOR DISSIPATED AFTER 2 HOURS. MSDR 2007FA0000239Light · failedPULSELIGHT UNIT FAILED. EVALUATION OF FAILED UNIT REVEALED HIGH HEAT GENERATED WITHIN UNIT AND SIGNIFICANT BURNING.SDR PIDA06030Socket · failedAUTO THROTTLE WILL NOT ENGAGE. THRUST MANAGEMENT COMPUTER FAILS INTERFACE TEST; FAULTS OF NO INFORMATION AUTO THROTTLE WARNING-1 NORMAL & WARNING-1 BATTERY DUE TO LIGHT SOCKET BROKEN. REPLACED LIGHT SOCKET. THE LIGHT INDICATING CONTINUITY OF THE CIRCUIT DIDSDR KBM2006F00036Light · stickingUNIT STICKING, BODY LIGHT. (K)SDR EIA2005161Battery · dischargedM/D RIGHT STA 2180 1EA EMERGENCY LIGHT INOP. RECHARGED LIGHT BATTERY AND OPS CHECKED GOOD PER B747 MM 33-51-00.SDR EIA2005164Battery · dischargedR5 DOOR EMERGENCY LIGHT INOP. RECHARGED BATTERY AND OPS CHECKED PER B747 MM 33-51-50.SDR DL76S050465Battery Pack · failedWHILE TS 2R DOOR EXT EMERG LIGHT FOUND RT WING OVERWING EGRESS LIGHTS INOP AND LT SLIDE LIGHTS INOP ALSO FOUND 2L EXT EMERG LIGHT INOP. RELAMPED 2L EXT EMERG LIGHT OPS CKS OK REPLACED M731 AND M738 PWR SUPPLIES AND BATTERIES RT O WING EGRESS LIGHTS AND LT WINSDR TXER100211Switch · inoperativeLIGHT SWITCH INOPERATIVESDR VNAA0403005Light · failedTHE CREW REPORTED THAT THE ROW 8 EMERGENCY FLOOR LIGHTING WAS NOT WORKING. MAINTENANCE INSPECTED AND REPLACED THE AMBER LIGHT STRIP IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SESDR CA040114001Module · corroded(CAN) WATER INGRESS AND HUMIDITY FROM AIR VENTS AND DOOR SEAL LEAK. LEADS TO CORROSION AND SUBSEQUENT FAILURE OF THE WARNING LIGHTS, DIMMING MODULE LOCATED BEHIND THE INSTRUMENT PANEL.SDR BAQA088852Light · mismanufacturedPOST LIGHTS HAVE FACTORY DEFECT. WILL SHORT OUT IF CHANGING LIGHT BULB. WE HAD TALKED TO NICK FISCHER.SDR I05R088840Light · inoperativeANTI COLLISION LIGHT INOPERATIVE REPLACED ANTICOLLISION LIGHT WITH S/N 553 OUT OF AIRFLITE STOCK ORDERED NEW PART FOR AIRFLITE STOCK UNDER WARRANTY.SDR VNAA0306015Light · failedTHE CREW REPORTED THAT THE EMERGENCY FLOOR LIGHTING WAS NOT WORKING AT SEAT 9A. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY FLOOR PATH LIGHT STRIP IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFTSDR VNAA0302015Power Supply · failedTHE CREW REPORTED THE EMERGENCY AND BACK UP BATTERIES FAIL TO TEST. MAINTENANCE INSPECTED AND REPLACED BOTH EMERGENCY POWER SUPPLIES IN ACCORDANCE WITH DONIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SESDR VNAA0302009Socket · failedTHE CREW REPORTED THE AFT EMERGENCY LIGHTING WAS NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY TRACK LIGHTING LIGHT STRIP SOCKET IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WSDR EIA2003005Card · burnedDURING CLIMB OUT WE SMELLED STRONG ELECTRICAL FUMES FROM COCKPIT SOMEWHERE AROUND FE's PANEL.fOUND PC CARD A16 AND TYPE II LAMP DIMMER CARD A14 BURNT. REPLACED CARD IAW MM 33-11-01. FOR PRECAUTIONARY REPLACED DIMMER AND TRANSFORMER FE LIGHT CONTROL PANEL IAW MSDR VNAA0211013Power Supply · failedTHE CREW REPORTED THAT THE EMERGENCY LIGHTING WAS NOT WORKING AT ROWS 6 TO 9. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY POWER SUPPLY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASESDR C2XA02BT061Light · faultyEWR---CO3489, CREW REPORTED THAT THERE WAS AN ELECTRICAL SMELL IN THE AFT CABIN (AT SEATS 17A AND 18A) AIRCRAFT PLACED ON MEL #33-20-00 CATEGORY "C" CONTROL NUMBER 031926. ....MAINTENANCE REMOVED AND REPLACED CEILING LIGHT ASSEMBLY AT SEAT 17A AREA. OPS.CHECKSDR VNAA0208034Power Supply · failedTHE CREW REPORTED THAT THE EMERGENCY POWER SUPPLY WOULD NOT TEST. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY POWER SUPPLY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SERVICSDR DL757020875Bulb · burned outON LAYOVER FOUND DOOR L1 EXTERIOR EMERGENCY LIGHT BURNED OUTREPLACED BULB. LIGHT OPERATES NORMALSDR VNAA0207008Power Supply · failedTHE CREW REPORTED THAT THE FORWARD EMERGENCY POWER SUPPLY WOULD NOT TEST. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY POWER SUPPLY IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL TESTS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FORSDR MAS2002F00003Light · inoperativeFORWARD EMERGENCY EGRESS LIGHT ON LEFT AT PAX DOOR, INOPERATIVE MECHANIC REPLACED BULB. OPS CHECKS GOOD.SDR HEEA079045Switch · brokenLIGHTING SYSTEM SWITCH BROKEN. REPLACED WITH SERVICEABLE PART.SDR VNAA0204019Power Supply · failedTHE AIRCRAFT HAD THE EMERGENCY BATTERY CHANGED PRIOR TO FLIGHT 4189. HOWEVER, ON THE TAXI FROM THE GATE THE EMERGENCY LIGHTING AT ROWS 3 AND 4 DIDN'T ILLUMINATE. THE FLIGHT RETURNED TO THE GATE WHERE MAINTENANCE CHANGED THE POWER SUPPLY IN ACCORDANCE WITH MASDR VNAA0203009Wire · failedTHE CREW REPORTED THAT THE EXIT SIGN AT ROW 9A WAS NOT WORKING. MAINTENANCE INSPECTED AND REPLACED THE EXIT SIGN DUE TO A BROKEN WIRE IN ACCORDANCE WITH DORNIER MAINTENANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WAS RELEASED FOR SDR DL757020214Bulb · burned out4L AND 4R DOOR EXTERIOR EMERG LITES OUT C/A RELAMPEDSDR DL767020053Battery · dischargedMID LEFT AND RIGHT OVERHEAD EMERGENCY LIGHTS INOP REPLACED_BATTERY PACKSSDR VNAA0112018Power Supply · failedTHE CREW REPORTED THATTHE EMERGENCY LIGHTING STRIP AT ROWS 3-6 WERE NOT ILLUMINATING. MAINTENANCE INSPECTED AND REPLACED THE EMERGENCY POWER SUPPLY IN ACCORDANCE WITH DORNIER MAINTE NANCE MANUAL 33-00-00. OPERATIONAL CHECKS WERE PERFORMED AND THE AIRCRAFT WASDR HEEA077214Power Supply · dischargedPOWER SUPPLY DEAD.SDR HEEA077210Power Supply · inoperativePOWER SUPPLY INOPERATIVE.SDR M01111Lamp · inoperativeDURING A MAINTENANCE PERFORMANCE CHECK, THE CREW FOUND A EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE LIGHT AND OPS CHECKED GOOD.SDR M01110Bulb · failedDURING SCHEDULED MAINTENANCE, THE CREW FOUND THE LEFT HAND WING EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE BULB, OPS CHECKED GOOD AND THE AIRCRAFT RETURNED TO SERVICE.SDR USAASB01255Ballast · failedBWI-MDW - FLT 2735 - DURING CRUISE, SMOKE WAS REPORTED IN THE AFT GALLEY. THE AFT GALLEY CIRCUIT BREAKER WAS PULLED AND THE SMOKE SUBSIDED. THE FLIGHT CREW DECIDED TO DIVERT TO PIT AND THE AIRCRAFT LANDED WITHOUT INCIDENT. THE AFT GALLEY WORK LIGHT WAS PLACSDR M01097Fabric · inoperativeDURING A PREFLIGHT INSPECTION, THE CREW FOUND THE RIGHT AFT FUSELAGE EXTERNAL EMERGENCY FLOOD LIGHT INOPERATIVE. THIS ITEM WAS DEFERRED PER MEL. LATER MAINTENANCE REMOVED AND REPLACED THE EMERGENCY FLOOD LIGHT.SDR M01092Bulb · failedDURING ROUTINE MAINTENANCE, THE CREW FOUND THE RIGHT HAND FORWARD NR 2 OVERWING EMERGENCY LIGHT INOPERATIVE. MAINTENANCE REPLACED THE LIGHT BULB AND OPS CHECKED GOOD.