JASC 3320

Service difficulty reports · 2,972

Reports filed under 3320 · Passenger Compartment Lighting, newest first.

Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy
  FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet'
  WHERE jasc_code = '3320'
  ORDER BY difficulty_date DESC"

Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.

SDR ASOA2018060105144Control Module · odorBURNING ODOR REPORTED IN THE FORWARD CABIN. MX INSPECTED THE FORWARD CABIN PSU'S AND LIGHT COVERS FOR EVIDENCE OF BURNED AREAS, NONE NOTED. REPLACED THE CABIN LIGHT CONTROL MODULE, RAN LIGHTING, APU, AND AIR CONDITIONING WITH NO ODORS NOTED. ACFT WAS APPRMay 30, 2018 · N10575 · Emb EMB145LRSDR GTIA2018051742654Light · inoperativeSTRONG ELECTRICAL ODOR IN THE COCKPIT AND FWD CABIN. CONTINUED LG PG 2371999-01, ACCOMPLISHED TSM 24-00-00-810-823-A, PFM WAS CLEAN. NO BURNING ODOR NOTED IN THE E&E BAYS IAW AMM 52-41-00. ACCOMPLISHED AVEC TEST IAW AMM 21-26-00, TESTED OK. PERFORM TEMay 14, 2018 · N516NK · Airbus A319132SDR DALA2018051103234Light · odorREADING LIGHT AT 38B FLICKERED THEN BURNED OUT. GAVE AN ELECTRICAL ODOR. INITIALLY A LITTLE SMOKE THEN DISSIPATED QUICKLY. ODOR LINGERED BUT DID NOT INTENSIFY. FOUND PAX SEAT 37C READING LIGHT AT FAULT. REPLACED LIGHT ASSY AND BOARD PER CMM 25-23. ALSO READINGMay 10, 2018 · N709TW · Boeing 7572Q8SDR DALA2018042002663Lamp · inoperativeTHRESHOLD LIGHT INOPERATIVE. ENTRY LIGHT BLEW WITH SPARKS. REPLACED THE LAMPS. CHECKED OK.Apr 19, 2018 · N932DL · Doug MD88SDR ASOA201804124022Control Module · malfunctionedGRK - THE CREW REPORTED A BURNING SMELL ABOVE SEAT 1A. MAINTENANCE REMOVED AND REPLACED A LIGHT CONTROL MODULE, OPERATIONALLY TESTED WITH NO DEFECTS OR SMELL NOTED AND THE AIRCRAFT WAS APPROVED FOR RETURN TO SERVICE.Apr 12, 2018 · N11539 · Emb EMB145LRSDR AALA201804089003Lens · missingL2 DOOR AREA READING LIGHT LENS MISSING. REPLACED THE LENS IAW MM 33-25-00.Apr 5, 2018 · N184US · Airbus A321211SDR SIMA20180322003Light · inoperativeAFT COURTESY CEILING LIGHT INOPERATIVE. REMOVED AND REPLACED THE LIGHT IAW IAW AMM 33-26-00. OPS CHECKED GOOD.Mar 22, 2018 · N820AE · Emb EMB135KLSDR ASOA201803197034Socket · burnedSTRONG ELECTRICAL BURNING ODOR IN THE CABIN. FOUND A SOCKET FOR A LIGHT AT A4 BURNED. REMOVED AND REPLACED THE CEILING LIGHT ASSY. OPS CHECKED GOOD. RETURNED TO SERVICE.Mar 18, 2018 · N14562 · Emb EMB145LRSDR WX0A2018031973314Ballast · failedBURNING ODOR AROUND ROW 37 DEF, DURING DESCENT. FOUND A BAD CONNECTOR P1-6149 AT BALLAST. R & R THE BALLAST.Mar 16, 2018 · N418NV · Doug DC983SDR AALA201803129010Switch · out of adjustAIRCRAFT WAS NOT GROUNDED, ENTRY DOOR ARMED LIGHT INTERMITTENT ON GROUND AND WOULDN'T GO BRIGHT IN FLIGHT. MAINTENANCE ADJUSTED DOOR LIGHT SWITCH PER MM 33-21-12 AND PERFORMED SATISFACTORY OPERATIONAL CHECK.Mar 9, 2018 · N127AA · Airbus A321231SDR IPXA2018031227342Lamp · inoperativeLAVATORY MIRROR LIGHTS INOPERATIVE. REPLACED THE LAMPS IAW AMM 33-51-0401. OPS CHECKED GOOD.Mar 9, 2018 · N156UP · Airbus A300F4622RSDR S9BA20180309001Socket · shortedWINDOW LIGHTS AT ROWS 6 AND 7 SMELL LIKE BURNING PLASTIC.Mar 9, 2018 · N350CJ · Saab 340BSDR ASOA201802283009Inverter · faultyTHE CREW REPORTED SMOKE FROM ABOVE EICAS APPEARED TO COME FROM FLOOD LIGHT OVER EICAS. SMOKE STOPPED WHEN THE FLOOD LIGHT WAS TURNED OFF. MAINTENANCE INSPECTED AND REPLACED THE FLOOD LIGHT ABOVE EICAS AND REPLACED POWER INVERTER. OPERATIONAL CHECKS WERE GOOD. Feb 28, 2018 · N14991 · Emb EMB145LRSDR WX0A2018041073311Light · smokeFA NOTICED SMOKE SMELL IN GALLEY AND ISOLATED SMOKE TO THE LIGHT ABOVE OVEN. LIGHT WAS TURNED OFF AND SMOKE DISSIPATED/PERFORMED CABIN SMOKE T/S IAW WORK CARD. DETERMINED THAT IT WAS FROM GALLEY LIGHT OVER OVEN. RELAMPED LIGHT.Feb 27, 2018 · N404NV · Doug MD88SDR WX0A201803073311Light · defectiveFA NOTICED SMOKE SMELL IN GALLEY AND ISOLATED SMOKE TO THE LIGHT ABOVE OVEN. LIGHT WAS TURNED OFF AND SMOKE DISSIPATED/PERFORMED CABIN SMOKE T/S IAW WORK CARD. DETERMINED THAT IT WAS FROM GALLEY LIGHT OVER OVEN. PLACED LIGHT ON MEL.Feb 27, 2018 · N404NV · Doug MD88SDR SCNA20180212062Light · inoperativeON LANDING IN MIA AFT F/A REPORTED STONG ELECTRIC FUMES IN AFT PORTION. FUMES DISSAPATED RELATAVLEY QUICKLY. ACCOMPLISHED FIM TASK. NO EVIDENCE OF BURNING SMELL. OK FOR SERVICE. SUSPECT AFT RIGHT LAV BULB BURNED OUT SOURCE OF SMELL. AFT RIGHT LAV MIRROR LIGHTFeb 12, 2018 · Boeing 7378K2SDR CALA2018020900538Lamp · failedREADING LIGHT AT SEAT 22D PRODUCED A LITTLE SMOKE, BECAME INOPERATIVE AND STOPPED SMOKING. REPLACED THE LAMP. OPS CHECKED OK.Feb 9, 2018 · N33714 · Boeing 737724SDR ASOA201802077006Printed Ckt Board · burnedTYS A/C WAS IN A A-CHECK CONDITION WHEN INSPECTION FOUND THE LAV RETURN TO SEAT LIGHT PC BOARD BURNT. MAINTENANCE REMOVED AND REPLACED THE PC BOARD ASSEMBLY IAW AMM 33-23-05. OPS CHECK WAS GOOD AND WAS RELEASED.Feb 8, 2018 · N27200 · Emb EMB145XRSDR IPXA2018020826356Lamp · inoperativeLAVATORY MIRROR LIGHT INOPERATIVE REPLACED THE LAMPS IAW 33-51-21-04-01.Feb 7, 2018 · N164UP · Airbus A300F4622RSDR SWAA2018020819615Light · odorACRID ODOR RT SIDE IN MID-CABIN ROW 14. R&R SIDEWALL LIGHT BULB PER AMM.Feb 6, 2018 · N717SA · Boeing 7377H4SDR CALA2018012900390Light · odorUPON ARRIVAL CREW REPORTED AC BURNING SMELL COMING FROM EMERGENCY EXIT MIDDLE AREA OF THE MAIN CABIN, REMOVED 6 CEILING PANELS TO FIND SOURCE OF SMELL. NIGHT LIGHT ON TOP OF OVERHEAD BIN AT ROW 23 LEFT IS NOT SECURED DUE TO BROKEN BRACKET/LAMP HOLDER. BULB IS Jan 29, 2018 · N33289 · Boeing 737824SDR CALA2018012700354Light · odorSMELL OF SOMETHING SIMILAR TO ELECTRICAL BURNING FROM DOOR 2 GALLEY FWD FOUND CEILING LIGHTS AT SEAT 25A AND 27A INOP. BALLAST ON LIGHT ASSY AT 25A HAS BURNT ELECTRICAL SMELL. REPLACED BOTH LIGHT ASSY. CHECKS GOOD. PERFORMED ELECTRICAL TASK IN MM05-51-58-800-8Jan 27, 2018 · N773UA · Boeing 777222SDR RAIA201801250001Unknown · odorINTERIOR LIGHTS FLICKERING WITH ASSOCIATED BURNING ODOR. PERFORMED INSPECTION AND OPS CHECK OF CABIN LIGHTS. VERIFIED ALL CABIN LIGHTS OPERATIONAL. NO BURNING ODOR NOTED.Jan 25, 2018 · N621AE · Emb EMB145LRSDR SIMA20180125003Ballast · failedFAINT ELECTRICAL BURNING ODOR COMING FROM GALLEY AND FIRST CLASS AREA. FOUND BALLAST BURNED OUT AT 1CD, REMOVED AND REPLACED SIDEWALL BALLAST AND CEILING BALLAST IAW AMM 33-21-03 AND 33-21-09, OPS CHECKED GOOD. ALSO CHANGED SIDEWALL LIGHT BULBS IAW AMM 33-2Jan 25, 2018 · N506AE · Cndair CL6002C10SDR AALA201801199039Relay · burnedNR 1 FA REPORTED A BURNING ELECTRICAL ODOR AT THE SAME TIME THE AFT CABIN LIGHTS WOULD NOT COME ON. AFTER LANDING AND AT THE GATE, THE LIGHT CAME ON WITH NO ELECTRICAL ODOR. THE AIRCRAFT WAS GROUNDED. INSTALLED A NEW RELAY FOR THE AFT UPPER LIGHTING IAW WDMJan 14, 2018 · N979TW · Doug MD83SDR Q2SA20180114387Wire · damagedNO SIDEWALL LIGHTS ON LEFT AND RIGHT SIDE OF MAIN CARGO DECK DO NOT ILLUMINATE. AIRCRAFT GROUNDED. SIGN OF BURN WITH CONNECTED WIRES DISCOLORED AND BURNED AS WELL ON RELAY K24051. RELAY K24051, TERMINAL MODULES TB400(5) &(6), AND ASSOCIATED WIRING REPLACEDJan 14, 2018 · N714SA · Boeing 777FZBSDR QXEA2018011200014Circuit Card · malfunctionedREADING LIGHT ABOVE ROW 15 AB OVERHEATING. REMOVED FROM SERVICE. REPLACED THE CIRCUIT CARD, OPS CHECKED GOOD. RETURNED TO SERVICE.Jan 12, 2018 · N410QX · Bombdr DHC8402SDR BUEA20180108002Control Module · failedPILOT REPORTED AFTER LANDING, A BURNING ODOR COMING FROM ROW 1, THIS IS THE FOURTH DISCREPANCY OF THIS NATURE. MAINTENANCE REMOVED AND REPLACED A LIGHTS CONTROL MODULE. NO FURTHER ODOR WAS DETECTED AND THE ACFT WAS RETURNED TO SERVICE. IT IS NOTED AT NO TIME Jan 6, 2018 · N359AD · Emb EMB145EPSDR BUEA20180108001Ballast · odorPILOT REPORTED AFTER LANDING, A BURNING ODOR WAS COMING FROM ROW1. THIS THIS THE THIRD REPORT OF A DISCREPANCY OF THIS NATURE. MAINTENANCE REMOVED AND REPLACED THE LIGHT BALLAST ASSY. NO ODOR DETECTED AND ACFT RETURNED TO SERVICE.Jan 5, 2018 · N359AD · Emb EMB145EPSDR DALA2018010400060Light · shortedCALL SYSTEM CIRCUIT BREAKER POPPED, WILL NOT RESET. T/S PER WDM 33-21. FOUND DEBRIS SHORTING PSU AT ROW 28ABC. REMOVED DEBRIS. RESET C/B, SYSTEM OPS NRML.Jan 3, 2018 · N979DL · Doug MD88SDR CA180103004Light · overheated(CAN) DURING BOARDING, A PASSENGER IN SEAT 1F NOTICED AN UNUSUAL ODOR. THE PASSENGER BROUGHT THIS TO THE CREW`S ATTENTION. THE CREW DECIDED TO DE-PLANE THE PASSENGERS VIA THE MAIN CABIN DOOR. SUBSEQUENT INVESTIGATION FOUND THE SIDEWALL LIGHT ASSEMBLY IN THEJan 2, 2018 · Cndair CL6002B19SDR AALA201801039011Ballast · failedFLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR ASSOCIATED WITH LIGHTING IN AFT GALLEY. ODOR WENT AWAY WHEN LIGHTS TURNED OFF. MAINTENCE FOUND THE RIGHT GALLEY CEILING LIGHT BLINKING, REPLACED THE BALLAST IAW AMM 33-20-00 AND PERFORMED SUCCESSFUL OPS CHECK, NO Dec 31, 2017 · N679AW · Airbus A320232SDR CALA2017121704495Light · unknownWHITE EMERGENCY LIGHTS IN CEILING ROWS 7-10 TURN ON REPEATEDLY IN FLIGHT. TESTED THE CABIN INTERIOR LIGHTS AND EMERGENCY EXIT LIGHTS. ALL LIGHTS CONTROL AND TEST OK.Dec 17, 2017 · N38467 · Boeing 737924ERSDR SCNA20171216311Ballast · shortedFLIGHT ATTENDANT REPORTED AN ELECTRICAL ODOR 2L AFT LAV, RAN QRH AND DIVERTED. SHORT FOUND IN MIRROR LIGHT IN THE L2 LAVATORY, COLLARED THE CIRCUIT BREAKER. REMOVED AND REPLACED THE BALLAST. CHECKED GOOD. OK FOR SERVICE.Dec 16, 2017 · N715SY · Boeing 737752SDR WX0A201712153299Ballast · odorFA REPORTED BURNING ODOR NEAR THE OVERWING AREA OF THE CABIN/ R&R LOWER SIDEWALL LIGHT BALLAST AND BULB"Dec 13, 2017 · N878GA · Doug DC983SDR AALA201712139007Lens · missingAIRCRAFT NOT GROUNDED. LIGHT CLEAR LENS COVER MISSING AT DOOR 4L AREA. REPLACED LIGHT LENS COVER AT DOOR 4L PER AMM 33-26-01.Dec 12, 2017 · N805NN · Boeing 737823SDR DALA2017120608480Socket · shortedAFT INBOARD LAV LIGHTING HAD A SHORT IN A BULB, CAUSING SPARKING AND SOME SMOKE - NO LAV SMOKE ALERT, FOUND WATER MAKING CONTACT WITH BOTTOM LIGHT STRIP IN AFT LAV DRIED AREA. FWD TO NEF 33-26-01.Dec 4, 2017 · N363NW · Airbus A320212SDR DALA2017112908379Light · fodTHE CAPTAIN REPORTED A FIRE IN THE CABIN AT THE L1 DOOR AND TAXIED THE AIRCRAFT BACK TO THE GATE. THE FLIGHT ATTENDANT USED THE FIRE EXTINGUISHER ON A BURNING NAPKIN IN THE OVERHEAD LIGHT FIXTURE. THE NAPKIN REMAINS WERE REMOVED BY THE FLIGHT ATTENDANT. MAINNov 26, 2017 · N947AT · Boeing 717200SDR AALA201711269002Ballast · inoperativeAIRCRAFT NOT GROUNDED. SMELL IN AFT CABIN, DESCRIBED AS EPOXY OR BURNING ORDER. FOUND COVE LIGHT BALLAST AT ROW 21 LEFT INOPERABLE. REPLACED COVE LIGHT BALLAST PER 33-21-11-04.Nov 23, 2017 · N659AW · Airbus A320232SDR CALA2017112304192Bulb · inoperativeRIGHT FWD OVERWING FLOURESCENT TUBE INOPERATIVE. R & R THE THE BULB AND FUSE IAW AMM 33-21-00-960-801 AND 33-21-00-960-803. OPS CHECKED GOOD.Nov 23, 2017 · N87513 · Boeing 737824SDR CALA2017111003986Light · smokeREADING LIGHT AT SEAT 34F WOULD NOT TURN OFF. STARTED TO SMOKE. TURNED UTILITY BUSS OFF. LIGHT STOPPED SMOKING. REPLACED THE SEAT 34F READING LIGHT ASSY AND TURN ON THE LIGHT FOR AN HOUR . OPS CHECKED OK IAW MM 33-23-00.Nov 10, 2017 · N77865 · Boeing 757324SDR N6WA2017111300001Ballast · overtempELECTRICAL ODOR FROM BEHIND THE MIRROR IN THE LAVATORY. MIRROR TO HOT TO TOUCH. DEACTIVATED THE LAVATORY VANITY BALLAST IAW EO 33-005-0.Nov 9, 2017 · N156GJ · Cndair CL6002C10SDR SIMA20171106004Lamp · inoperativePAX CEILING LIGHT AT SEAT 3A INOPERATIVE. REMOVED AND REPLACED THE LAMP IAW AMM 33-21-06, OP CHECKED GOOD.Nov 6, 2017 · N670AE · Emb EMB145LRSDR CALA2017110603933Socket · burnedTRANSIENT SMOKE LAVATORY ADVISORY MESSAGE DURING DESCENT WITH AN ELECTRICAL ODOR. FOUND FLUORESCENT LIGHT BULB SOCKET BURNED IN THE LAVATORY BY THE L2 DOOR. REPLACED THE SOCKET. ALSO CHANGED THE LIGHT BALLAST AS PRECAUTION IAW AMM 33-26-00-960-806 AND THE LANov 6, 2017 · N78004 · Boeing 777224SDR SWIA2017101643922Ballast · failedSMOKE ODOR IN THE CABIN. EMERGENCY DECLARED. REMOVED AND REPLACED LIGHT BALLAST AT ROW 4CD.Oct 25, 2017 · N809CA · Cndair CL6002B19SDR CALA2017102003692Ballast · burnedAUDIBLE WHIRRING NOISE WITH STRONG ODOR COMING FROM ABOVE LAVATORY B. UNABLE TO VERIFY THE REPORTED NOISE OR SOURCE OF THE ODOR. ODOR WENT AWAY AFTER REMOVED AND REPLACED BURNED MIRROR LIGHT BALLAST.Oct 20, 2017 · N56859 · Boeing 757324SDR CALA2017102003655Ballast · failedSMOKE ODOR REPORTED IN THE AFT LAVATORY B. EMERGENCY DECLARED. FOUND THE LAV BALLAST FAILED AND EMITTING ODOR. REPLACED THE MIRROR LIGHT BALLAST. ALL AFT LAVATORY ELECTRICAL FUNCTIONAL OPS TESTED OK. INCLUDING FASTEN SEAT BELT SIGN, ATT CALL ,MIRROR AND DOct 20, 2017 · N56859 · Boeing 757324SDR SIMA20171018001Ballast · failedCLIMBING THROUGHT 8000 FT, AFTER TAKE OFF, RECEIVED A LAVATORY SMOKE EICAS WARNING. F/A DID NOT SEE SMOKE BUT SMELLED UNUSUAL FUMES. RETURNED TO DEPARTURE. SMELLED FUMES IN COCKPIT ON FINAL. REMOVED AND REPLACED THE LT LAVATORY BALLAST IAW AMM 33-28-02.Oct 18, 2017 · N856AE · Emb EMB135KLSDR FDEA201710032848Light · inoperativeRIGHT DOOR SLIDE ARM LIGHT NOT ILLUMINATED WHEN FIRST OFFICER WENT TO DISARM THE DOOR. RT DOOR SLIDE ARM LIGHT FILLARMENTS REPLACED IAW AMM 33-20-00. OPS TESTED GOOD.Oct 3, 2017 · N915FD · Boeing 757236SDR AALA201710049008Socket · defectiveFLIGHT ATTENDANT REPORTS ELECTRICAL SMELL ON FINAL, STRONGER AFT OF FIRST CLASS TO EMERGENCY EXIT DOOR. REPLACED F/O'S DOME LT SOCKETS IAW AMM.Oct 3, 2017 · N540UW · Airbus A321231
Back to JASC 3320