JASC 3320
Service difficulty reports · 2,972
Reports filed under 3320 · Passenger Compartment Lighting, newest first.
Query with SQL
duckdb -csv -c "SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC"
Prints the whole list as CSV. It reads the release’s Parquet files over HTTPS, so there’s nothing to download first. Install DuckDB to run it.
SELECT sdr_id, difficulty_date, n_number, aircraft_make, aircraft_model, part_name, part_condition, jasc_code, discrepancy FROM 'https://openairdocs.org/data/latest/faa_service_difficulty_report.parquet' WHERE jasc_code = '3320' ORDER BY difficulty_date DESC
Run it at the DuckDB prompt, or in any tool that reads Parquet over HTTPS. More ways to query the release are on Use the data.
SDR ASOA20140111003Light · failedELECTRICAL BURNING ODOR REPORTED IN CABIN. MX FOUND CEILING LIGHT AT ROW 7 BURNED. REMOVED 7 REPLACED CEILING LIGHT ASSY AND OPS CHECKED SUCCESSFUL. ACFT APPROVED FOR RETURN TO SERVICE.SDR SIMA20140107002Ballast · faultyBURNT RUBBER ODOR IN COCKPIT ON TAXI OUT. R & R CEILING BALLASTS AT SEAT 10A IAW EMB-145 AMM 33-21-05. OPERATIONS CHECKED GOOD, NO DEFECT NOTED.SDR ASOA20140104004Ballast · overheatedTHE CREW REPORTED A BURNING ODOR FROM LIGHT BALLAST APPROXIMATELY ROW 1-3. LANDED WITHOUT INCIDENT. MAINTENANCE R & R LIGHT ASSY, OPS TESTED WITH NO DEFECTS. ACFT APPROVED FOR RETURN TO SERVICE.SDR ASOA20140102001Lamp · arcedDIVERTED, CREW REPORTED SMOKE IN CABIN LAVATORY AREA. LANDED SAFELY. CONTRACT MAINTENANCE FOUND SMOKE/ODOR TO BE COMING FROM LIGHT ASSEMBLY LAVATORY ABOVE TOILET. ISOLATED LIGHT ASSY AND PLACED ON NEF. ON 1/5/14. MX R & R BULB AND RESET BALLAST WITH OPS CHESDR DXTA2013122702610Light · fireFIRE FROM A/C DUCT UNDER LAVATORY SINK. FOUR INCH FLAME AFTER SMOKE APPEARED. ROTTEN ODOR DETECTED, COULD NOT IDENTIFY. REMOVED DAMAGED DROPPED AISLE LIGHT FROM THE AFT LEFT SIDE OF AISLE. INSTALLED A NEW DROPPED AISLE LIGHT. OPS CHECKED GOOD, NO DEFECTS NSDR SWIA201335726Light · faultySMOKE & SMELL ASSOCIATED WITH INTERIOR LIGHTS AT SEAT 6A. FLT 6362 REPLACED SIDEWALL LIGHT FIXTURE AT SEATS 5A & 6A.SDR SWIA201335714Ballast · faultyBURNED ODOR AROUND ROW 2C. OVERHEAD LIGHTS EXTINGUISHED OVER THE SAME ROW. FLT 6226 REPLACED BALLAST FOR OVERHEAD LIGHTS AT ROW 2 SEATS CD.SDR CHQA20131219458Light · odorCREW REPORTED ELECTRICAL SMELL FROM ROW 7. MX TROUBLE SHOT THE ISSUES TO THE CEILING LIGHT AT ROW 7A. THE LIGHT IS CURRENTLY ON DEFERRAL & THE FINAL CORRECTIVE ACTION & PART INFORMATION WILL BE SUBMITTED AS A SUPPLEMENT TO THIS REPORT.SDR MASA2013121828017Light · smokeSMOKE AND FUMES, ROW 18, LT SIDE, READING LIGHT 18A FAILED, REPLACED.SDR ASOA20131216223Socket · shortedTHE CREW REPORTED A STRONG ELECTRICAL BURNING ODOR IN FRONT CABIN. MAINTENANCE INSPECTED AND FOUND THE OVERHEAD LIGHT SOCKET SHORTED AND MELTED. R & R AFFECTED HARNESS, OPS TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR SIMA20131215008Light · defectiveON FLIGHT 3311 FLIGHT ATTENDANT REPORTED SMOKE & BURNING ODOR, COMING FROM 2A, READING LAMP IS MISSING LENS COVER. SHUT OFF LAMP, SMOKE & ODOR WENT AWAY. THE ACFT WAS REMOVED FROM SERVICE. RELAMPED BOTH PAX READING LIGHTS AT SEAT 2A IAW SMP. OPERATIONS CHECSDR CALA2013121393672Cover · missingSEAT BELT SIGN MISSING COVER ON LT COACH BULKHEAD. REPLACED SEAT BELT SIGN COVER COACH FWD BULKHEAD.SDR SWIA201335534Light · inoperativeFLIGHT ATTENDANT CALL LIGHT ON MIDDLE EXIT SIGN IS BURNED OUT. FLT 6192 RELAMPED PN 6839.SDR SWIA201335509Light · malfunctionedSMOKE COMING FROM SIDE WALL LIGHTS AT 7A. FLT 3475 REPLACED LIGHT FIXTURE AT SEAT 7A, IAW AMM. PN BC1-0065-003SDR DXTA2013120205588Light · contaminatedTHE ODOR OF HOT PLASTIC OR HOT VINYL WAS NOTICED BY 4 CREW MEMBERS. THE ODOR IS MUCH STRONGER TOWARDS THE CEILING OF THE CABIN. THE STRONGEST ODOR COMING FROM THE CEILING BETWEEN SEATS 3 & 5. NO SMOKE IS NOTICED. DUCT SUPPLY TEMP IS 46 DEGREES TO THE CABIN SDR CALA2013120393403Module · faultyUNABLE TO CONTROL B & C ZONE CEILING & READING LIGHT. REPLACED ZMU 2 IAW AMM, CHECKED OKAY.SDR SIMA20131126004Light · defectiveFLIGHT ATTENDANT REPORTS READING LIGHT 16 B WAS SMOKING. STOPPED SMOKING WHEN IT WAS TURNED OFF. LIGHT BULB BAD AT SEAT 16 B. R & R SEAT 16B READING LIGHT ASSEMBLY IAW AMM CHAPT 33-22-01, OPERATIONS CHECKED GOOD.SDR REXA2013112602276Light · smokeFLIGHT ATTENDANT REPORTS SMOKE FROM READING LIGHTS OUT 4AB. PERFORMED OPERATIONAL CHECK OF THE READING LIGHTS IAW AMM 33-21-00, OPERATIONS CHECKED GOOD. TURNED ON & WATCHED FOR ABOUT 10 MINS. NO SMOKE OR OTHER DEFECTS NOTED.SDR WX0A071762Socket · meltedFLIGHT ATTENDANT`S & PAX REPORTED FUMES IN AFT CABIN MAINLY LT SIDE. PERFORMED QRH 26.2 PULLED RECIRC BREAKERS WITH NO HELP. SECURING RT PACK CAUSED FUMES TO DISAPPEAR. FUMES WERE DESCRIBED AS MELTING ELECTRICAL. FOUND AIR LEAKING FROM RT ACM. RT PACKED DESDR IPXA2013112200911Lamp · inoperativeLAVATORY AUXILARY MIRROR LIGHT INOPERATIVE. REPLACED LAMP, CHECKED GOOD.SDR UIEA2013112200567Light · looseLIGHT STRIP GALLEY LOOSE. SECURED LIGHT IN AFT GALLEY IAW AMM 25-27-08.SDR IPXA2013111500849Bulb · inoperativeLAVATORY MIRROR LIGHT INOPERATIVE, REPLACED BULB.SDR AALA20131108001Ballast · overheatedLIM INFLIGHT SCL-MIA. CREW REPORTED ELECTRICAL BURNING SMELL IN FIRST CLASS LAVATORY FOLLOWED BY VERY DISTINCT ELECTRICAL SMELL IN AFT GALLEY AREA. IFE POWER PORTS BUSS SWITCHES TURNED OFF & LESSENED BUT DID NOT ELIMINATE THE SMELL. EMERGENCY DECLARED FLIGHSDR SWIA201335194Light · defectiveREADING LIGHT ABOVE SEAT 1D BECAME VERY HOT. FLT#5501 REPLACED 1D READING LIGHT ASSEMBLY & LIGHTING COVER AT 1D IAW AMM.SDR CALA2013103092527Light · burnedPOSSIBLE ELECTRICAL SMOKE SMELL, SOURCE NOT IDENTIFIED. SMELL DISSIPATED NO OBVIOUS IRREGULARITIES NOTED. DID FIND NO SMOKING FASTEN SEAT SIGN LIGHT BULBS BURNT AT ROW 25 DEF. RELAMPED, OPERATIONS CHECKED GOOD. FOUND BURNT PAINT IN READING LIGHTS 26 DEF.SDR CALA2013102392327Ballast · faultyON CM CHECK FOUND SEAT 6K FWD SIDEWALL LIGHT NOT ILLUMINATED. REPLACED BALLAST AT SEAT 6K, OPERATIONS CHECKED OKAY.SDR IPXA201310180628Lamp · inoperativeDURING MX INSPECTION, THE LAVATORY MIRROR LIGHT WAS INOPERATIVE. REPLACED LAMP IAW AMM, OPS CHECKED GOOD.SDR IPXA201310180605Bulb · inoperativeDURING MX INSPECTION, THE LAVATORY MIRROR LIGHT FOUND TO BE INOPERATIVE. REPLACED BULB. OPS CHECKED GOOD.SDR UHLA2013101400531Lens · loosePIECE OF FLUORESCENT FLOOR LIGHTING NEEDS TO BE REATTACHED IN FRONT OF FWD CLOSET. RESECURED FLUORESCENT STRIP AS REQUIRED.SDR CALA2013101592059Light · inoperativeMID GALLEY, RT SMALL INCANDESCENT LAMP INOPERATIVE. REPLACED LIGHT ASSEMBLY. OPERATIONS CHECKED OKAY.SDR IPXA3180530Lamp · inoperativeDURING MX INSPECTION, LAVATORY AUX/MIRROR LIGHT FOUND TO BE INOPERATIVE. REPLACED LAMPS IAW AMM 33-51-21-401. OPS CHECKED GOOD.SDR DALA13050429243Light · failedF/A REPORTED SMOKE COMING FROM PASSENGER SEAT 25C READING LIGHT. R & R READING LIGHT ASSEMBLY IAW AMM. OPS CHECKED NORMAL. NO SMOKE OR ODOR NOTED.SDR SWAA2013100720874Ballast · faultyAFT GALLEY WORK LIGHT & COFFEE MAKER FLICKER ON & OFF, ALSO SLIGHT ELECTRICAL SMELL. R & R BALLAST IAW TC.SDR SIMA20131004001Light · failedDURING MX INSPECTION, OVERHEAD LIGHT HAD ELECTICAL ODOR AND WENT AWAY AFTER TURNING LIGHTS OFF. PERFORMED OPS CHECK OF CABIN LIGHTS AND READING FOR 40 MINUTES, NO ODOR OR SMOKE NOTED. FOUND READING LIGHTS AT 4C AND 4B INOPERATIVE. R & R CIRCUIT BOARD FUSES SDR ASOA20131002183Light · smokeREADING LIGHT AT 11B WAS REPORTED AS SMOKING WHEN IT WAS TURNED ON. MX R & R THE AFFECTED READING LIGHT, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20131002182Light · smokeTHE READING LIGHT AT 11B WAS REPORTED AS SMOKING WHEN IT WAS TURNED ON. MX R & R THE AFFECTED READING LIGHT, OPERATIONALLY TESTED WITH NO DEFECTS, AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR ASOA20130929177Control Module · overheatedCREW REPORTED A BURNING ODOR IN THE FWD CABIN AND GALLEY AREA. MX R & R THE LIGHT CONTROL MODULE AT SEAT 1A, OPS TESTED WITH NO DEFECTS AND THE ACFT WAS APPROVED FOR RETURN TO SERVICE.SDR DALA13048810175Ballast · burnedBURNING ODOR IN THE CABIN, LOCATED AT SEAT 18A. MX FOUND INDIRECT CEILING LIGHT BALLAST WITH BURNED FUSE AND REPLACED SAME. SYSTEM CHECKED NORMAL.SDR CALA2013092691501Light · inoperativeNO SMOKE SIGN INOP ACROSS FROM JUMP SEAT 5L. RELAMPED, OPS CHECKED OKAY.SDR ASOA20130923112Ballast · overheatedCREW REPORTED A BURNING ELECTRICAL ODOR LIKE A SOLDERING IRON OR HAIR CURLER, ABOVE SEAT 1A. DETERMINED THE ODOR TO BE COMING FROM THE SEAT 1A BALLAST. R & R CEILING LIGHT ASSY AT SEAT 1A WITH OPS CHECK GOOD.SDR ASOA20130922071CBallast · failedTHE CREW REPORTED BURNING ODOR IN CABIN BY LT SIDE CEILING LIGHT. MX INSPECTED AND REPLACED THE CEILING LIGHT BALLAST OVER SEAT 2A. OPS CHECKED GOOD.SDR DALA13049090936Ballast · burnedDURING CLIMBOUT, AN ACRID ODOR BEGAN ISSUING FROM AIR CONDITIONING DUCTS. THE ENGINE ANTI-ICE WAS ON AND NORMAL PNEUMATIC CONFIGURATION. SELECTED A COLDER TEMP ON PACKS AND FUMES EVENTUALLY DISSIPATED. FOUND INOPERATIVE LIGHTING BALLAST AT ROW 33ABC. BALLSDR SWIA201334693Light · malfunctionedBURNING TYPE STRONG PUNGENT SMELL EMANATING FROM LAVATORY AREA. FLT#5295 REPLACED LAVATORY VANITY LIGHT ASSEMBLY.SDR HNAA2013092000503Bulb · dimCABIN, CEILING EXIT SIGN AT CENTER ISLE OF ROW 1 IS DIM, R & R DIM LIGHTS OF CEILING EXIT SIGN AT CENTER ISLE OF ROW 1 OPS CHECKED GOOD, REINSTALLED CEILING COVER.SDR REXA2013091501827Light · odorF/A ADVISED MGT STRONG ODOR LIKE BURNING WIRE ABOUT MID CABIN. NO SMOKE NOTED FROM A/C SYSTEM. FOUND SOURCE OF ODOR TO BE COMING FROM PSU READING LIGHTS AT 5B. PERFORMED REQUIRED MX PROCEDURES BY DISCONNECTING LEADS. R & R SEAT 5B READING LIGHT, PN CDEL10SDR VNAA2013090800004Relay · failedCREW REPORTED ODOR OF BURNING RUBBER NEAR EXIT ROW. LIGHTS OUT ABOVE BINS ON ROW 8 D/F. MX INSPECTED, R & R POWER RELAY AT ROW 8 D/F AND PERFORMED CHECKS IAW AMM. ACFT RELEASED FOR SERVICE.SDR CALA2013091091178Light · inoperativeCEILING LIGHT AT SEAT ROW 22RT INOPERATIVE. RELAMPED, OPERATIONS CHECKED GOOD.SDR SWIA201334475Ballast · burnedSMOKE SMELL ASSOCIATED WITH LAVATORY MOTOR RUNNING. FLT#6211 INSPECTED SMOKE SMELL FOUND LIGHT BALLAST BURNED. REPLACED BALLAST.SDR CHQA20130904336Ballast · odorCREW REPORTED AN ELECTRICAL BURNING ODOR COMING FROM CABIN LIGHT BALLAST NEAR ROWS 7 AND 8. MX PERFORMED GENERAL VISUAL INSPECTIONS AND OPS CHECKS OF THE CABIN LIGHTING SYS AND NO SIGNS OF ELECTRIAL BURNING WERE NOTED AND NO ODORS PRESENT. NO FURTHER DISCREPSDR CALA2013090490963Light · damagedWORK WITH DF0855, RT FWD LAVATORY 100 DOME LIGHT FOUND LUG BROKEN ON PLANE SIDE, REPLACED WHITE LUG ON WIRE NR 2. REF SSM 33-26-11 & SWP 20-30-11. FOUND DOME LIGHT ASSEMBLY WIRE LOOSE & BURNT. DOME LIGHT REFLECTOR BROKEN RECEIVED ASSEMBLY PCN 566- 1341 & CA
Back to JASC 3320